• Title/Summary/Keyword: Dental Engineering

Search Result 1,047, Processing Time 0.034 seconds

Ochratoxin A Contamination of Red Chili Peppers from Chile, Bolivia and Peru, Countries with a High Incidence of Gallbladder Cancer

  • Ikoma, Toshikazu;Tsuchiya, Yasuo;Asai, Takao;Okano, Kiyoshi;Ito, Naoko;Endoh, Kazuo;Yamamoto, Masaharu;Nakamura, Kazutoshi
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.14
    • /
    • pp.5987-5991
    • /
    • 2015
  • Our previous study detected aflatoxins in red chili peppers from Chile, Bolivia, and Peru, each of which have a high incidence of gallbladder cancer (GBC). Since the aflatoxin B1 concentration was not so high in these peppers, it is important to clarify the presence of other mycotoxins. Here we attempted to determine any associations between the concentrations of aflatoxins and ochratoxin A (OTA) in red chili peppers, and the corresponding GBC incidences. We collected red chili peppers from three areas in Peru: Trujillo (a high GBC incidence area), Cusco (an intermediate GBC incidence area), and Lima (a low GBC incidence rate), and from Chile and Bolivia. Aflatoxins and OTA were extracted with organic solvents. The concentrations of aflatoxins B1, B2, G1, and G2, and OTA were measured by high-performance liquid chromatography. The values obtained were compared with the incidence of GBC in each area or country. All of the red chili peppers from the three areas showed contamination with aflatoxins below the Commission of the European Communities (EC) recommended limits ($5{\mu}g/kg$), but the OTA contamination of two samples was above the EC recommended limit ($15{\mu}g/kg$). The mean concentrations of OTA in the peppers from Chile (mean $355{\mu}g/kg$, range < $5-1,059{\mu}g/kg$) and Bolivia (mean $207{\mu}g/kg$, range $0.8-628{\mu}g/kg$), which has a high incidence of GBC, were higher than that in Peru ($14{\mu}g/kg$, range < $5-47{\mu}g/kg$), which has an intermediate GBC incidence. The OTA contamination in the red chili peppers from Chile, Bolivia, and Peru was stronger than that of aflatoxins. Our data suggest that OTA in red chili peppers may be associated with the development of GBC.

Lack of an Apparent Association between Mycotoxin Concentrations in Red Chili Peppers and Incidence of Gallbladder Cancer in India : an Ecological Study

  • Ikoma, Toshikazu;Kapoor, Vinay Kumar;Behari, Anu;Mishra, Kumudesh;Tsuchiya, Yasuo;Asai, Takao;Endoh, Kazuo;Okano, Kiyoshi;Nakamura, Kazutoshi
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.7
    • /
    • pp.3499-3503
    • /
    • 2016
  • Our recent studies conducted in South America have shown that mycotoxin contamination of red chili peppers (RCPs) may be associated with an increased risk of gallbladder cancer (GBC). Whether this relationship exists in India, a country with a high incidence of GBC and high consumption of RCPs, is unclear. We therefore measured concentrations of aflatoxins (AFs) and ochratoxin A (OTA) in RCPs from areas of low, medium, and high incidence of GBC in India, and compared these concentrations with GBC incidence in each area. Twenty-one RCP samples were collected from nine cities (eight from a low-incidence area, five from a medium-incidence area, and eight from a high-incidence area). Concentrations of AFs and OTA were measured using high-performance liquid chromatography. No significant differences in mean concentrations of AFs and OTA were found in the three areas. AFB1 levels in the low-incidence area ($10.81{\mu}g/kg$) and high-incidence area ($12.00{\mu}g/kg$) were more than 2.2 and 2.4 times higher compared with the maximum permitted level of AFB1 in spices ($5.0{\mu}g/kg$) set by the Commission of the European Communities, or that ($4.4{\mu}g/kg$) obtained in our previous study in Chile. Our results show that the mean concentrations of mycotoxins in RCPs are similar among the three areas in India with different incidences of GBC. Further studies with human subjects are needed to evaluate any association between AFB1 and GBC.

CHANGES OF ABUTMENT SCREW AFTER REPEATED CLOSING AND OPENING

  • Kim Hee-Jung;Chung Chae-Heon;Oh Sang-Ho;Choi Han-Cheol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.6
    • /
    • pp.628-640
    • /
    • 2004
  • Statement of problem. Wear as a result of repeated closing/opening cycles may decrease the friction coefficient of screw head, threads, and other mating components and, consequently, resistance to opening gradually decreases. It may cause screw loosening, which is one of the most common failures in implant prosthesis. Purpose. The purpose of this study is to evaluate the changes on the head and thread surface of the abutment screws after repeated closing and opening through the examination of tested screws in SEM(scanning electron microscope). Materials and methods. Five species of abutments were selected (3i-three, Avana-two) respectively by two pieces. The implant fixtures were perpendicularly mounted in liquid unsaturated polyesther(Epovia, Cray Valley Inc.) with dental surveyor. Each abutment was secured to the implant fixture by each abutment screw with recommended torque value using a digital torque controller. The abutment screws were repeatedly tightened and removed 20 times with a digital controller. FESEM (field emission scanning electron microscope, Netherland, Phillips co., model:XL 30 SFEG) was used to observe changes of each part caused by repeatedly closing/opening expeiment. First, the Photomicrographs of pre-test screws provided by each manufacturer were taken. The changes of each screw were investigated after every fifth closing and opening experiment with FESEM. Scaning electron microscope photomicrographs of each screw were taken four times. Results. As the number of closing and opening was increased, the wear or distortion of hexed or squared slot that contacted with the driver tip was more severely progressed. Wear or distortion of hexed slot was more severe than that of squared slot and it was more remarkable in the titanium screw than in the gold screw. All the tested screws showed that the width in the crest of their screw thread decreased gradually as the test was proceeded. Conclusions. Conclusively, we recommend the clinical use of gold screw, a periodic exchanges of abutment screws and avoiding repeated closing/opening unnecessarily. We also suggest a more careful manipulation of the abutment screw and screw-driver and using of abutment screw with an acute-angled slot design rather than an obtuse-angled one. Finally, it is suggested that the new slot design and the surface treatment for enduring wear or distortion should be devised.

The effect of the strength and wetting characteristics of Bis-GMA/TEGDMA-based adhesives on the bond strength to dentin (2,2-Bis[4-(2-methoxy-3-methacryloyloxy propoxy) phenyl] propane을 함유한 상아질 접착레진의 물성이 접착강도에 미치는 영향)

  • Park, Eun-Sook;Kim, Chang-Keun;Bae, Ji-Hyun;Cho, Byeong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.2
    • /
    • pp.139-148
    • /
    • 2011
  • Objectives: This study investigated the effect of the strength and wetting characteristics of adhesives on the bond strength to dentin. The experimental adhesives containing various ratios of hydrophobic, low-viscosity Bis-M-GMA, with Bis-GMA and TEGDMA, were made and evaluated on the mechanical properties and bond strength to dentin. Materials and Methods: Five experimental adhesives formulated with various Bis-GMA/Bis-MGMA/TEGDMA ratios were evaluated on their viscosity, degree of conversion (DC), flexural strength (FS), and microtensile bond strength (MTBS). The bonded interfaces were evaluated with SEM and the solubility parameter was calculated to understand the wetting characteristics of the adhesives. Results: Although there were no significant differences in the DC between the experimental adhesives at 48 hr after curing (p > 0.05), the experimental adhesives that did not contain Bis-GMA exhibited a lower FS than did those containing Bis-GMA (p < 0.05). The experimental adhesives that had very little to no TEGDMA showed significantly lower MTBS than did those containing a higher content of TEGDMA (p < 0.05). The formers exhibited gaps at the interface between the adhesive layer and the hybrid layer. The solubility parameter of TEGDMA approximated those of the components of the primed dentin, rather than Bis-GMA and Bis-M-GMA. Conclusions: To achieve a good dentin bond, a strong base monomer, such as Bis-GMA, cannot be completely replaced by Bis-M-GMA for maintaining mechanical strength. For compatible copolymerization between the adhesive and the primed dentin as well as dense cross-linking of the adhesive layer, at least 30% fraction of TEGDMA is also needed.

A Study on the Awareness and Preparation of the Forth Industrial Revolution of Some Health Department College Students (일부 보건계열학과 대학생의 4차 산업혁명 인식 및 준비도 연구)

  • Cho, Hye-Eun
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.12
    • /
    • pp.291-299
    • /
    • 2020
  • The purpose of this study was to be used as basic data for the development of future-type curriculum in health. The awareness and preparation of the forth industrial revolution were surveyed on 280 college students in health departments preparing medical technicians. A self-written structured questionnaire was used for data collection, and the recognition of the forth industry revolution was 2.74, 3D printing (3.59) was high, and neural network machine learning(2.33) was the lowest. Students majoring in Physiotherapy (3.00) had the highest perception, and those majored in Dental engineering(2.37) had the lowest perception, and there was a difference in the degree of perception of IoT by major (p=0.024). For the forth industrial revolution, 54.5% of students are preparing, and lack of interest (42.9%) is the most difficult reason to prepare, and 50.6% of educational experience and 60.9% of VR&AR game experience have experience. In the era of the forth industrial revolution, job loss (38.7%) was high, and the required competency was creative capacity (50.6%). Therefore, it is necessary to develop a curriculum related to the fourth industrial revolution and apply teaching methods that can increase the awareness and preparation of health college students in the era of the fourth industrial revolution.

ISOLATION OF PORCINE MULTIPOTENTIAL SKIN-DERIVED PRECURSOR CELLS AND ITS MULTILINEAGE DIFFERENTIATION (미니돼지에서 다능성 피부유래 전구세포의 추출과 이의 다배엽 세포로의 분화유도에 대한 연구)

  • Choi, Moon-Jeong;Byun, June-Ho;Kang, Eun-Ju;Rho, Gyu-Jin;Kim, Uk-Kyu;Kim, Jong-Ryoul;Park, Bong-Wook
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.34 no.6
    • /
    • pp.588-593
    • /
    • 2008
  • There are increasing reports regarding regeneration of the defected tissues using tissue engineering technique. In this technique, multipotential stem cells are essential. There are many potential sources of adult stem cells, such as bone marrow, umbilical cord blood, fat, muscle, dental tissues and skin. Among them, skin is highly accessible and easily obtained with a minimum of donor site complications. Moreover, skin is an abundant adult stem cell sources and has the potential for self-replication and immune privilege. In this study, we isolated skin-derived precursor cells (SKPs) from the ear of adult miniature pigs. In these SKPs, the expression of transcriptional factors, Oct-4, Sox-2, and Nanog were detected by RT-PCR. In vitro osteogenesis and adipogenesis were observed at 3 weeks after transdifferentiations as assayed by positive von Kossa and Oil-red O staining, respectively. In addition, expression of osteocalcin and osteonectin in the osteogenic differentiation medium and $PPAR{\gamma}2$ and aP2 in the adipogenic differentiation medium were detected by RT-PCR. In vitro neurogenesis of porcine SKPs was observed during 24 and 72 hours after treatment of neurogenic differentiation medium. The results of this study suggest that SKPs demonstrate the properties of pluripotence or multipotence and multi-lineage differentiation. This indicates that autogenous SKPs are a reliable and useful source of adult stem cells for regenerative medicine.

Adaptive Optimal Thresholding for the Segmentation of Individual Tooth from CT Images (CT영상에서 개별 치아 분리를 위한 적응 최적 임계화 방안)

  • Heo, Hoon;Chae, Ok-Sam
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.41 no.3
    • /
    • pp.163-174
    • /
    • 2004
  • The 3D tooth model in which each tooth can be manipulated individualy is essential component for the orthodontic simulation and implant simulation in dental field. For the reconstruction of such a tooth model, we need an image segmentation algorithm capable of separating individual tooth from neighboring teeth and alveolar bone. In this paper we propose a CT image normalization method and adaptive optimal thresholding algorithm for the segmenation of tooth region in CT image slices. The proposed segmentation algorithm is based on the fact that the shape and intensity of tooth change gradually among CT image slices. It generates temporary boundary of a tooth by using the threshold value estimated in the previous imge slice, and compute histograms for the inner region and the outer region seperated by the temporary boundary. The optimal threshold value generating the finnal tooth region is computed based on these two histogram.

Investigations on the effects of mouthrinses on the colour stability and surface roughness of different dental bioceramics

  • Soygun, Koray;Varol, Osman;Ozer, Ali;Bolayir, Giray
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.3
    • /
    • pp.200-207
    • /
    • 2017
  • PURPOSE. In this study, three bioceramic materials, [IPS Empress CAD (Ivoclar), IPS e.max CAD (Ivoclar), and Lava Ultimate CAD (3M ESPE)] were treated with three commercial mouthrinses [Listerine, Tantum Verde, and Klorhex]; and changes in colour reflectance and surface roughness values were then quantitatively assessed. MATERIALS AND METHODS. One hundred and twenty ceramic samples, with dimensions of $2{\times}12{\times}14mm$, were prepared and divided into nine sample groups, except three control samples. The samples were immersed in the mouthrinse solutions for 120 hrs, and changes in colour reflectance and surface roughness values were measured by UV light spectrophotometry (Vita Easyshade; VITA Zahnfabrik) and by profilometer device (MitutoyoSurftest SJ-301), respectively. The change of surface roughness was inspected by Scanning Electron Microscopy (SEM) and Atomic Force Microscopy (AFM). RESULTS. There was a positive correlation between the ${\Delta}E$ and increase in the surface roughness. Two of the ceramic materials, IPS Empress and Lava Ultimate, were affected significantly by the treatment of the mouthrinse solutions (P<.05). The most affecting solution was Tantum Verde and the most affected material was Lava Ultimate. As expected, the most resistant material to ${\Delta}E$ and chemical corrosion was IPS e max CAD among the materials used. CONCLUSION. This work implied that mouthrinse with lower alcohol content had less deteriorating effect on colour and on the surface morphology of the bioceramic materials.

Biometrics Based on Multi-View Features of Teeth Using Principal Component Analysis (주성분분석을 이용한 치아의 다면 특징 기반 생체식별)

  • Chang, Chan-Wuk;Kim, Myung-Su;Shin, Young-Suk
    • Korean Journal of Cognitive Science
    • /
    • v.18 no.4
    • /
    • pp.445-455
    • /
    • 2007
  • We present a new biometric identification system based on multi-view features of teeth using principal components analysis(PCA). The multi-view features of teeth consist of the frontal view, the left side view and the right side view. In this paper, we try to stan the foundations of a dental biometrics for secure access in real life environment. We took the pictures of the three views teeth in the experimental environment designed specially and 42 principal components as the features for individual identification were developed. The classification for individual identification based on the nearest neighbor(NN) algorithm is created with the distance between the multi-view teeth and the multi-view teeth rotated. The identification performance after rotating two degree of test data is 95.2% on the left side view teeth and 91.3% on the right side view teeth as the average values.

  • PDF

Verification of a computer-aided replica technique for evaluating prosthesis adaptation using statistical agreement analysis

  • Mai, Hang-Nga;Lee, Kyeong Eun;Lee, Kyu-Bok;Jeong, Seung-Mi;Lee, Seok-Jae;Lee, Cheong-Hee;An, Seo-Young;Lee, Du-Hyeong
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.5
    • /
    • pp.358-363
    • /
    • 2017
  • PURPOSE. The purpose of this study was to evaluate the reliability of computer-aided replica technique (CART) by calculating its agreement with the replica technique (RT), using statistical agreement analysis. MATERIALS AND METHODS. A prepared metal die and a metal crown were fabricated. The gap between the restoration and abutment was replicated using silicone indicator paste (n = 25). Gap measurements differed in the control (RT) and experimental (CART) groups. In the RT group, the silicone replica was manually sectioned, and the marginal and occlusal gaps were measured using a microscope. In the CART group, the gap was digitized using optical scanning and image superimposition, and the gaps were measured using a software program. The agreement between the measurement techniques was evaluated by using the 95% Bland-Altman limits of agreement and concordance correlation coefficients (CCC). The least acceptable CCC was 0.90. RESULTS. The RT and CART groups showed linear association, with a strong positive correlation in gap measurements, but without significant differences. The 95% limits of agreement between the paired gap measurements were 3.84% and 7.08% of the mean. The lower 95% confidence limits of CCC were 0.9676 and 0.9188 for the marginal and occlusal gap measurements, respectively, and the values were greater than the allowed limit. CONCLUSION. The CART is a reliable digital approach for evaluating the fit accuracy of fixed dental prostheses.