• Title/Summary/Keyword: Dental Engineering

Search Result 1,047, Processing Time 0.028 seconds

Evaluation of the marginal and internal gaps of three different dental prostheses: comparison of the silicone replica technique and three-dimensional superimposition analysis

  • Park, Jin-Young;Bae, So-Yeon;Lee, Jae-Jun;Kim, Ji-Hwan;Kim, Hae-Young;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권3호
    • /
    • pp.159-169
    • /
    • 2017
  • PURPOSE. The purposes of this study were to evaluate the marginal and internal gaps, and the potential clinical applications of three different methods of dental prostheses fabrication, and to compare the prostheses prepared using the silicone replica technique (SRT) and those prepared using the three-dimensional superimposition analysis (3DSA). MATERIALS AND METHODS. Five Pekkton, lithium disilicate, and zirconia crowns were each manufactured and tested using both the SRT and the two-dimensional section of the 3DSA. The data were analyzed with the nonparametric version of a two-way analysis of variance using rank-transformed values and the Tukey's post-hoc test (${\alpha}=.05$). RESULTS. Significant differences were observed between the fabrication methods in the marginal gap (P < .010), deep chamfer (P < .001), axial wall (P < .001), and occlusal area (P < .001). A significant difference in the occlusal area was found between the two measurement methods (P < .030), whereas no significant differences were found in the marginal gap (P > .350), deep chamfer (P > .719), and axial wall (P > .150). As the 3DSA method is three-dimensional, it allows for the measurement of arbitrary points. CONCLUSION. All of the three fabrication methods are valid for measuring clinical objectives because they produced prostheses within the clinically acceptable range. Furthermore, a three-dimensional superimposition analysis verification method such as the silicone replica technique is also applicable in clinical settings.

치과용 지르코니아 코어에서 착색농도에 따른 색조측정 (Measure of shade differences according to the concentration of dental zirconia coloring liquid)

  • 배은정;이희정;김혜영;김웅철;김지환
    • 대한치과기공학회지
    • /
    • 제35권3호
    • /
    • pp.193-200
    • /
    • 2013
  • Purpose: In this study, in order to provide objective standard of the mixed concentration of the zirconia coloring-liquids, compare the shade differences after colored zirconia blocks from different concentrations. Methods: After immersion for 2 minutes zirconia specimen ($1.5{\times}1.5{\times}0.6{\pm}0.01mm$) in coloring-liquids that produced different concentrations, were sintered in furnace dedicated. Then, it was measured in spectrophotometer and Shadepilot. It has been determined mean and standard deviation of the color difference for each group, and verified by one-way ANOVA using the (version12.0) SPSS WIN Program the difference in shade according to the concentration at the significance level of 95% confidence, it conducted a Tukey's multiple range test to post-test. Results: The mean of $L^*$ was decreased toward LN35 group, however the mean of $a^*$ and $b^*$ was increased(p<.05). There is a statistically significant difference in the results of $L^*$ post hoc test of each group was LN15-LN30/LN35, LN20-LN30/LN35, LN25-LN30/LN35, and LN30-LN35 group. The $a^*$ group, it was found that there is a statistically significant difference in all groups for each(p<.05). The $b^*$ group, it was found that there is a statistically significant difference in all groups except the LN25-LN30(p<.05). Conclusion: In order to make effective use of the coloring-liquids of zirconia, the device objective, accurate concentration measurement is required, from the present study, we presented evidence basic to this.

구강 내 스캐너를 사용하여 CAD/CAM으로 제작된 왁스 코핑의 적합도 평가 (Evaluation of marginal and internal gap of wax coping fabricated by CAD/CAM system using intraoral scanner)

  • 김동연;정일도;이재준;김지환;김명배;김웅철
    • 대한치과기공학회지
    • /
    • 제37권1호
    • /
    • pp.1-7
    • /
    • 2015
  • Purpose: The aim of this study was to evaluate the marginal and internal gap of wax copings fabricated from extraoral scanning with intraoral scanning. Methods: Fifteen study models(abutment of teeth 16) were made by PMMA. STL files of thirty abutment were prepared by intraoral scanning with extraoral scanning. Wax copings of thirty fabricated using CAD/CAM system. Marginal and internal gap of wax copings of thirty were measured by silicone replica technique and digital microscope(${\times}140$). Date were analyzed by using independent samples t-test. Results: Mean (SD) of two group were measured $55.61(27.42){\mu}m$ for totally gap of ES group and $60.67(33.14){\mu}m$ for totally gap of IS group. But marginal and internal gap of two group were not differences statistically significant(p>0.05). Conclusion: Evaluation of marginal and internal gap of two group showed that no differences statistically significant and clinically acceptable results.

열 가압 방식을 사용하여 제작된 인레이 세라믹 수복물의 적합도 평가 (Assessment of inlay ceramic restorations manufactured using the hot-pressing method)

  • 이범일;유승규;유승민;박동인;김지환
    • 대한치과기공학회지
    • /
    • 제42권1호
    • /
    • pp.9-16
    • /
    • 2020
  • Purpose: The purpose of this study was to compare the marginal and internal fit of lithium disilicate ceramic inlay produced by heat pressing that inlay pattern made by subtractive manufacturing and additive manufacturing method. Methods: A mandibular lower first molar that mesial occlusal cavity (MO cavity) die was prepared. After fabricating an epoxy resin model using a silicone impression material, epoxy resin die was scanned with a dental model scanner to design an MO cavity inlay. The designed STL pile was used to fabricate wax patterns and resin patterns, and then lithium disilicate ceramic inlays were fabricated using hot-press method. For the measurement of the marginal and internal gap of the lithium disilicate, silicone replica method was applied, and gap was measured through an optical microscope (x 80). Data were tested for significant differences using the Mann-Whitney Utest. Results: The marginal fit was 103.56±9.92㎛ in the MIL-IN group and 81.57±9.33㎛ in the SLA-IN group, with a significant difference found between the two groups (p<0.05). The internal fit was 120.99±17.52㎛ in the MIL-IN group and 99.18±6.65㎛ in the SLA-IN group, with a significant difference found between the two groups (p<0.05). Conclusion: It is clinically more appropriate to apply the additive manufacturing than subtractive manufacturing method in producing lithium disilicate inlay using CAD/CAM system.

Anxiety before dental surgery under local anesthesia: reducing the items on state anxiety in the State-Trait Anxiety Inventory-form X

  • Koga, Sayo;Seto, Mika;Moriyama, Shigeaki;Kikuta, Toshihiro
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제17권3호
    • /
    • pp.183-190
    • /
    • 2017
  • Background: It is important to evaluate preoperative anxiety and prepare sedation when performing dental surgery under local anesthesia. Spielberger's State-Trait Anxiety Inventory (STAI) is useful for predicting preoperative anxiety. State anxiety is defined as a subjective feeling of nervousness. Reduction in the number of the state anxiety items (questions) will be clinically important in allowing us to predict anxiety more easily. Method: We analyzed the STAI responses from 1,252 patients who visited our institution to undergo dental surgery under local anesthesia. Multiple linear regression analysis was conducted for 9 groups comprising anxiety level determinations using the STAI; we then developed a coefficient of determination and a regression formula. We searched for a group satisfying the largest number of requirements for regression expression while setting any necessary conditions for accurately predicting anxiety before dental surgery under local anesthesia. Results: The regression expression from the group determined as normal for preoperative state anxiety was deemed the most suitable for predicting preoperative anxiety. Conclusion: It was possible to reduce the number of items in the STAI by focusing on "Preoperative anxiety before dental surgery."

치과 CAD/CAM 시스템 보유 현황 및 사용 만족도 조사 연구 (A study on the possession state of dental CAD/CAM system and usage satisfaction)

  • 배은정
    • 대한치과기공학회지
    • /
    • 제42권1호
    • /
    • pp.45-53
    • /
    • 2020
  • Purpose: The purpose of this study was to investigate the current status and satisfaction of dental CAD/CAM system. Methods: A survey of dental technicians was conducted and a total of 353 responses were used for analysis. The satisfaction difference according to career was analyzed by ANOVA and tukey HSD (α = .05). Results: Satisfaction with the design program was 3.64 ± .86, the highest among all items. On the other hand, the satisfaction with price was 2.75 ± 1.02, which was the lowest. The difference according to career was statistically significant in the following items. Frequent breakdown, single crown margin, bridge crown margin, retentivity, price, A/S, equipment training (p<.05). Conclusion: As the materials applied to dental CAD/CAM are expanding and the types of prostheses are diversified, the use rate of CAD/CAM is continuously increasing. The dental CAD/CAM system will need to be improved in a way that will satisfy all patients, dentists and dental technicians.

치과 캐드캠 시스템의 가공 방식에 따른 금속 코핑의 적합도 비교 (Comparison of the Marginal and Internal Gap of Metal Coping according to Processing Method of Dental CAD/CAM System)

  • 김동연;전진훈;박진영;김지환;김혜영;김웅철
    • 치위생과학회지
    • /
    • 제15권1호
    • /
    • pp.12-17
    • /
    • 2015
  • 본 연구에서는 치과 CAD/CAM 시스템을 이용하여 SM 가공 방식으로 코핑을 제작 후 주조한 금속 코핑과, AM 가공 방식으로 코핑을 제작 후 주조한 금속 코핑과의 변연 및 내면 적합도를 비교 평가하여 다음과 같은 결과를 얻었다. SM 가공 방식과 AM 가공 방식의 변연 적합도 부분에서는 $120{\mu}m$ 임상적 허용 범위에 존재하였다. SM 가공 방식과 AM 가공 방식의 변연 적합도 및 내면 적합도는 통계적으로 유의한 차이가 있는 것으로 나타났다(p<0.05). SM 가공 방식과 AM 가공 방식으로 제작된 두 그룹의 전체 적합도와 4부분 부위별 적합도 측정은 SM 가공 방식보다 AM 가공 방식이 우수하였다. 결론적으로 금속 코핑의 변연 및 내면 적합도는 SM 가공 방식보다 AM 가공 방식이 우수하였고, 그 결과 값들은 임상적 허용범위 안에 존재하였다. 앞으로 치과분야에서 AM 가공 방식에 관한 연구는 계속되어야 하며, 보다 완성도 높은 금속 코핑 제작이 가능하다고 생각된다.

Finite element analysis in static and dynamic behaviors of dental prosthesis

  • Djebbar, N.;Serier, B.;Bouiadjra, B. Bachir
    • Structural Engineering and Mechanics
    • /
    • 제55권1호
    • /
    • pp.65-78
    • /
    • 2015
  • In recent years, implants have gained growing importance in all areas of medicine. The success of the treatment depends on many factors affecting the bone-implant, implant-abutment and abutment-prosthesis interfaces. In this paper, static and dynamic behaviors of the dental prosthesis are investigated. Three-dimensional finite element models of dental prosthesis were constructed. Dynamic loads in 5 sec applied on occlusal surface. Therefore, FEA was selected for use in this study to examine the effect of the static and dynamic loads on the stress distribution for an implant-supported fixed partial denture and supporting bone tissue.

치기공학과 학생들의 블렌디드 러닝 흥미도와 만족도 간의 연관성 (A Study on the Relationship Between Blended Learning Interesting and Satisfaction on Students majoring in Dental Technology)

  • 강월;박연경;한만소;김웅철;김지환
    • 대한치과기공학회지
    • /
    • 제38권3호
    • /
    • pp.237-245
    • /
    • 2016
  • Purpose: The purpose of this study is to investigate the analysis blended learning interesting and satisfaction on students majoring in dental techniques. Method: The study subject were 181 students from Gimcheon university. Data for this survey was obtain by self-administration method. This questionnaire consist of $lecture^{\circ}$Øs interesting and satisfaction when using an blended learning in the lecture. SPSS 22.0 was used. Analysis of frequency was used and two sammple t-test was used to identify significantly different blended interesting and sataisfaction within the grade. Multiple regression was used to which interestings affect the satisfaction. Results: First, there were significant differences in the grade among the blended interesting and sataisfaction, while on differences in participation satisfaction(p<0.05). Second, The correlation coefficient is 0.714 between blended interesting and staisfaction, Third, Multiple regression showed that the $lecture^{\circ}$Øs interesting applying blended learning affects the satisfaction(p<0.05). Conclusion: Given the findings of the study, lecture applying blended learning seem to be efficient education programs to improve lecture's interesting & satisfaction.

CAD/CAM 밀링 시스템을 활용한 단일 치관과 3본 교의치의 3D 적합도 평가 (Three-dimensional evaluation of the internal adaptation of single and three-unit fixed dental restoration by CAD/CAM milling system)

  • 김소리;김총명;김웅철;김지환
    • 대한치과기공학회지
    • /
    • 제39권1호
    • /
    • pp.35-42
    • /
    • 2017
  • Purpose: The purpose of this paper was to evaluate the occurrence of errors regarding adaptation by conducting a three-dimensional assessment comparing the bridge type dental restoration after the cutting process, which has multiple abutments, with a single type dental restoration. Methods: By using ten identical files obtained by scanning the master model, thirty designs were created consisting of ten maxillary right first premolars and ten maxillary right first molars with single crown abutments, along with ten bridge designs with the identical abutment. A 5-axis milling machine was used to produce the design file. The produced denture prostheses were scanned using a silicone replica for a STL file. An evaluation was conducted using 3D analysis software on the master model and each of the thirty data files. Results: The RMS value of the pre-molar (14) was $38.4{\pm}4{\mu}m$ for single and $54.7{\pm}6{\mu}m$ for bridge abutment; therefore, a statistically significant difference was observed for single and bridge designs although both shared the same abutment form (P<.05). Also, the RMS value of the molar (16) was $47.6{\pm}2{\mu}m$ and $56.6{\pm}5{\mu}m$ for the single and bridge designs, respectively, thereby presenting a statistically significant difference (P<.05). Conclusion: As a result, dental prosthesis fabricated using the single method presented better internal adaptation outcomes.