• Title/Summary/Keyword: Dental CT

Search Result 513, Processing Time 0.026 seconds

CLINICAL STUDY ON THE ETIOLOGY, DIFFERENTIAL DIAGNOSIS AND TREATMENT OF TRISMUS (개구장애 환자의 병인, 감별진단 및 치료방식에 대한 임상연구)

  • Kang, Hee-Jea;Hwang, Dae-Seok;Kim, Yong-Deok;Shin, Sang-Hun;Kim, Uk-Kyu;Kim, Jong-Ryoul;Chung, In-Kyo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.32 no.6
    • /
    • pp.544-558
    • /
    • 2006
  • Trismus is a common problem to most people experiencing at once in his or her life and to most dental practitioners experiencing frequently. It has a number of potential causes which are single factor or complex factors. Its treatment will depend on the cause. The purpose of this study was to discuss the causes of trismus condition and the various treatments available. This study was made by reviewing of collected data from 86 patients complained of trismus among patients who were diagnosed by TMD, tumor, infection including tetanus, soft tissue anomalies, bony fracture and ankylosis from Jan 2002 to Dec 2004 on department of oral and maxillofacial surgery at Pusan National University Hospital, South Korea. The clinical reviews regarding chief complaints, clinical characteristics, diagnostic examination, treatments and the results on the patients were given as follows. 1. The etiology of trismus commonly were derived from temporomandibular joint(TMJ) disorder, TMJ ankylosis, TMJ tumor, odontogenic maxillofacial infection, mandibular condylar fracture, tetanus. 2. The chief complaints of trismus patients were progressive mouth opening limitation, TMJ pain, malocclusion, facial asymmetry, retrognathic state. 3. Especially, for the differential diagnosis between the fibrous ankylosis and true bony ankylosis, computed tomogram (CT) was useful. Surgical gap arthroplasty on bony ankylosis patients was applied and the gain of mouth opening after operation was average 35.8 mm during 19 months. 4. The tetanus, rarely, also induced the trismus with the range of mouth opening less than 10 mm. The average serum level of tetanus anti-toxin was 0.02-0.04 IU/mL. The limitation of mouth opening was improved into average 38 mm on 4 weeks after injection of 10,000 units of tetanus immune globulin. 5. In the treatment of osteochondroma, TMD, odontogenic infection and fracture, and the others inducing trismus, to obtian the maximum result and decreased inadequate time and effort, it is important to finding the causes from the exact clinical examination and diagnosis.

Comparison of cone beam computed tomography and conventional panoramic radiography in assessing the topographic relationship between the mandibular canal and impacted third molars (하악 제3대구치와 하악관과의 위치관계에 대한 파노라마 방사선사진과 cone beam형 전산화단층촬영상의 비교)

  • Choi, Hyung-Soo;Kim, Gyu-Tae;Choi, Yong-Suk;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • v.38 no.3
    • /
    • pp.169-176
    • /
    • 2008
  • Purpose : To assess the diagnostic accuracy and value in an imaging technique field through the comparison of cone beam computed tomography and conventional panoramic radiography in assessing the topographic relationship between the mandibular canal and impacted third molars. Materials and Methods : Participants consisted of 100 patients offered the images through cone beam computed tomography and panoramic radiography. PSR-$9000^{TM}$ Dental CT system (Asahi Roentgen Ind. Co., Ltd, Japan) was used as the unit of cone beam computed tomography. CE-II (Asahi Roentgen Ind. Co., Ltd, Japan) and Pro Max (Planmeca Oy, Finland) were used as the unit of panoramic radiography. The images obtained through panoramic radiography were classified into 3 types according to the distance between mandibular canal and root of mandibular third molar. And they were classified into 4 types according to the proximity of radiographic feature. The images obtained through cone beam computed tomography based on the classification above were classified into 4 types according to the location between the mandibular canal and the root and were analyzed. And they were classified into buccal, inferior, lingual, and between roots, according to the location between mandibular canal and root. The data were statistically analyzed and estimated by $X^2$-test. Results : 1. There was no statistical significance according to 3 types (type I, type II, type III) through CBCT. 2. The results of 4 types (type A, type B, type C, type D) through CBCT were as high prevalence of CBCT 1 in type A, CBCT 2 in type B, CBCT 3 in type C, and CBCT1 in type D and those of which showed statistical significance (P value=0.03). 3. The results according to location between mandibular canal and root through CBCT recorded each 49, 25, 17, 9 as buccal, inferior, lingual, between roots. Conclusion : When estimating the mandibular canal and the roots through the panoramic radiography, it could be difficult to drive the views of which this estimation was considerable. Thus it is required to have an accurate diagnostic approaching through CBCT that could estimate the location between mandibular canal and roots.

  • PDF

MORPHOLOGIC AND POSITIONAL CHANGE OF THE PROXIMAL SEGMENTS AFTER INTRAORALVERTICAL RAMUS OSTEOTOMY OF THE MANDIBULAR PROGNATHISM ON SUBMENTOVERTEX CEPHALOGRAM (하악골 전돌증환자의 구내 하악골상행지 수직골절단술후 이하두정 계측방사선사진상에서의 근심골편의 형태 및 위치 변화)

  • Chung, Jae-Hyung;Park, Hyung-Sik;Hwang, Chung-Ju
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.29 no.1
    • /
    • pp.26-34
    • /
    • 2003
  • Intraoral Vertical Ramus Osteotomy,along with Sagittal Split Ramus Osteotomy,is an popular surgical technique performed on mandibular prognathism. However Intraoral Vertical Ramus Osteotomy has been suspected for an initial mobilization at the healing phase of segment because it does not employ the rigid fixation between segments. To execute a study on the healing phase of segment after Intraoral Vertical Ramus Osteotomy on the horizontal plane, 102 patients (204 parts) who were diagnosed mandibular prognathism and took Intraoral Vertical Ramus Osteotomy at the Yonsei University dental hospital were observed during the period of before operation, immediately postoperation, 1 month, 3 months, 6 months, and 12 months. The change in the width of segment and horizontal angle of proximal segment and condylar head on the Submentovertex Cephalogram taken from those patients represented following results. 1. The width of proximal and distal segment decreased with the lapse of time. It decreased into 84.5% between immediate postoperative and 6M and even continued to decrease till 12M. 2. The horizontal angle of the proximal segment did medial rotation according as the lapse of time and rigorously continued till 3M. The rotation angle of condylar head indicated its tendency of recurrence to the original position but the entire recurrence was not allowed. The bigger an initial angle was, the higher was the tendency of recurrence after the operation while the rotation angle remained still bigger. 3. After grouping into group 1, group 2,and group 3 based on the extent of the variation of rotation angle of condylar head at immediate postoperative, the variation of rotation angle was measures in each group. The result presented that the initial rotation angle of condylar head had correlation with that of proximal segment but had no relation with the extent of setback of the mandible. However a quantitative analysis alone is not a sufficient method for analyzing the healing phase of segment on the horizontal plane.Therefore a multilateral analysis using 3 dimensional data such as CT is recommendable for the future study.

Volumetric accuracy of cone-beam computed tomography

  • Park, Cheol-Woo;Kim, Jin-ho;Seo, Yu-Kyeong;Lee, Sae-Rom;Kang, Ju-Hee;Oh, Song-Hee;Kim, Gyu-Tae;Choi, Yong-Suk;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • v.47 no.3
    • /
    • pp.165-174
    • /
    • 2017
  • Purpose: This study was performed to investigate the influence of object shape and distance from the center of the image on the volumetric accuracy of cone-beam computed tomography (CBCT) scans, according to different parameters of tube voltage and current. Materials and Methods: Four geometric objects(cylinder, cube, pyramid, and hexagon) with predefined dimensions were fabricated. The objects consisted of Teflon-perfluoroalkoxy embedded in a hydrocolloid matrix (Dupli-Coe-Loid TM; GC America Inc., Alsip, IL, USA), encased in an acrylic resin cylinder assembly. An Alphard Vega Dental CT system (Asahi Roentgen Ind. Co., Ltd, Kyoto, Japan) was used to acquire CBCT images. OnDemand 3D (CyberMed Inc., Seoul, Korea) software was used for object segmentation and image analysis. The accuracy was expressed by the volume error (VE). The VE was calculated under 3 different exposure settings. The measured volumes of the objects were compared to the true volumes for statistical analysis. Results: The mean VE ranged from -4.47% to 2.35%. There was no significant relationship between an object's shape and the VE. A significant correlation was found between the distance of the object to the center of the image and the VE. Tube voltage affected the volume measurements and the VE, but tube current did not. Conclusion: The evaluated CBCT device provided satisfactory volume measurements. To assess volume measurements, it might be sufficient to use serial scans with a high resolution, but a low dose. This information may provide useful guidance for assessing volume measurements.

Implant Supported Fixed Restoration for Maxillary Edentulism using CAD/CAM Guided Implant Surgery (NobelGuide$^{TM}$) and Immediate Loading (상악 완전 무치악 환자의 CAD/CAM 을 이용한 임플란트 식립(NobelGuide$^{TM}$) 및 즉시하중 후 고정성 보철수복 증례)

  • Huh, Yoon-Hyuk;Yi, Yang-Jin;Kim, Dae-Gon;Cho, Lee-Ra;Park, Chan-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.4
    • /
    • pp.423-439
    • /
    • 2012
  • This case report described a technique utilizing a computer-aided design (CAD)/computer-aided machining (CAM) - guided surgical implant placement and prefabricated temporary fixed prosthesis for an immediately loaded restoration. The advantages of CAD/CAM guided implant procedures are flapless, minimally invasive surgery and shorter surgery time. With this technique, less postoperative morbidity and delivery of prosthesis for immediate function would be possible. A patient with an edentulous maxilla received 8 implants in maxilla using CAD/CAM surgical templates. Prefabricated provisional maxillary implant supported fixed prosthesis were connected immediately after implant installation. Provisional prosthesis was evaluated for aesthetics, function during 6 months. Definitive implant supported fixed porcelain fused metal bridges were fabricated.

Restoration of an Edentulous Patient with CAD/CAM Guided Implant Surgery ($NobelGuide^{TM}$) and Immediate Loading: Case Report (무치악 환자에서 CAD/CAM을 이용한 임플란트 식립($NobelGuide^{TM}$) 및 즉시하중 증례)

  • Ko, Kyoung-Ho;Lim, Kwang-Gil;Kim, Dae-Gon;Park, Chan-Jin;Cho, Lee-Ra
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.2
    • /
    • pp.233-245
    • /
    • 2011
  • With the use of computed tomography (CT), computer-aided design/computer-assisted machining (CAD/CAM) technology and internet, the implant dentistry has been evolved. The surgical templates made by CAD/CAM technology and precise installation of implants, permit restorations to be inserted immediately after implants have been placed. The advantages of CAD/CAM guided implant procedures are flapless, minimally invasive surgery and shorter surgery time. With this technique, less postoperative morbidity and delivery of prosthesis for immediate function would be possible. A patient with an edentulous maxilla and mandible received 7 implants in mandible using CAD/CAM surgical templates. Prefabricated provisional fixed prostheses were connected immediately after implant installation. Provisional prostheses were evaluated for aesthetics and function during 6 months. Definitive prostheses were fabricated. At 6 months recall appointment, patient's occlusion was slightly changed. To prevent additional adverse effect, regular check-up and occlusal adjustment would be needed.

Implementation of Man-made Tongue Immobilization Devices in Treating Head and Neck Cancer Patients (두 경부 암 환자의 방사선치료 시 자체 제작한 고정 기구 유용성의 고찰)

  • Baek, Jong-Geal;Kim, Joo-Ho;Lee, Sang-Kyu;Lee, Won-Joo;Yoon, Jong-Won;Cho, Jeong-Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.1
    • /
    • pp.1-9
    • /
    • 2008
  • Purpose: For head and neck cancer patients treated with radiation therapy, proper immobilization of intra-oral structures is crucial in reproducing treatment positions and optimizing dose distribution. We produced a man-made tongue immobilization device for each patient subjected to this study. Reproducibility of treatment positions and dose distributions at air-and-tissue interface were compared using man-made tongue immobilization devices and conventional tongue-bites. Materials and Methods: Dental alginate and putty were used in producing man-made tongue immobilization devices. In order to evaluate reproducibility of treatment positions, all patients were CT-simulated, and linac-gram was repeated 5 times with each patient in the treatment position. An acrylic phantom was devised in order to evaluate safety of man-made tongue immobilization devices. Air, water, alginate and putty were placed in the phantom and dose distributions at air-and-tissue interface were calculated using Pinnacle (version 7.6c, Phillips, USA) and measured with EBT film. Two different field sizes (3$\times$3 cm and 5$\times$5 cm) were used for comparison. Results: Evaluation of linac grams showed reproducibility of a treatment position was 4 times more accurate with man-made tongue immobilization devices compared with conventional tongue bites. Patients felt more comfortable using customized tongue immobilization devices during radiation treatment. Air-and-tissue interface dose distributions calculated using Pinnacle were 7.78% and 0.56% for 3$\times$3 cm field and 5$\times$5 cm field respectively. Dose distributions measured with EBT (international specialty products, USA) film were 36.5% and 11.8% for 3$\times$3 cm field and 5$\times$5 cm field respectively. Values from EBT film were higher. Conclusion: Using man-made tongue immobilization devices made of dental alginate and putty in treatment of head and neck cancer patients showed higher reproducibility of treatment position compared with using conventional mouth pieces. Man-made immobilization devices can help optimizing air-and-tissue interface dose distributions and compensating limited accuracy of radiotherapy planning systems in calculating air-tissue interface dose distributions.

  • PDF

A clinical study of deep neck abscess in children (소아 심경부 농양의 임상적 고찰)

  • Lee, Soo Jung;Shin, Mee Yong;Kim, Chang Hwi;Koh, Yoon Woo
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.4
    • /
    • pp.363-368
    • /
    • 2007
  • Purpose : It has been reported that deep neck abscesses are recently increasing again. We analyzed pediatric cases with deep neck abscesses during the last several years to contribute to the treatment of the disease. Methods : The clinical data of 30 children under 16 years of age with deep neck abscess from February 2001 to July 2006 were analysed retrospectively. Results : The mean age was 9 years (2-16 years), and the male/female ratio was 19/11. Abscesses in the peritonsillar space were most common (57%), followed by the retropharyngeal (30%) and parapharyngeal (13%) spaces. Upper respiratory infection in 10 cases (33%), dental infection in four case (14%), cervical lymphadenitis in three case (10%) and sinusitis in two case (6%) contributed to the development of deep neck infections. The frequent symptoms were fever in 16 case (53%), sore throat in 15 case (50%), poor oral intake in 10 (33%), odynophagia in eight (27%), and neck pain in eight (27%). Unilateral tonsillar hypertrophy and displacement in 15 case (50%) were most common. Neck mass in 13 patients (43%), neck stiffness in three (10%) and trismus in three (10%) were also found. Bacteria were isolated in 8 among 10 pus cultures; Streptococcus species 7 and Micrococcus luteus 1. All of those bacteria except Micrococcus luteus were sensitive to penicillin G. Surgical intervention was applied to 12 cases (40%), and the remaining 18 patients (60%) were treated with antibiotics only. There were no differences between the two groups in the duration of admission and antibiotic treatment. No complicated cases were observed. Conclusion : Peritonsillar abscesses were most frequent. Upper respiratory infection was the most common predisposing factor, followed by dental infection and sinusitis. Symptoms of respiratory tract obstruction were not found. The most common pathogens were Streptococcus species. Deep neck abscesses in children, if diagnosed at the early stage, possibly can be treated by antibiotics only, without surgical intervention.

Interstitial Vaginal Needle Implantation in Gynecological Tumors : Design and Construction of Applicator (부인과암에서 조직내 삽입 방사선치료 - Applicator의 고안 및 제작-)

  • Kang, Seung-Hee;Chun, Mi-Son;Kang, Hae-Jin;Jung, Chil;Son, Jeong-Hyae
    • Radiation Oncology Journal
    • /
    • v.16 no.2
    • /
    • pp.167-175
    • /
    • 1998
  • Purpose : It is not a simple task to achieve the ideal isodose curve with a standard vaginal applicator or sing1e plane needle impant in the paravaginal tissue when primary or recurrent gynecological neoplasms(cervical cancers, vaginal cancers and vulvar cancers) are treated as a boost following external beam radiotherapy. The authors introduce the development and construction of a simple, inexpensive, customized applicator for volume implant to maximize the radiation dose to the tumor while minimizing the dose to the rectum and the bladder. Materials and Methods : Nine patients underwent Ir-192 transperineal interstitial implantation for either recurrent(5 cases) or primary(3 cases) cervical cancers or primary vaginal cancer(1 case) between August 1994 and February 1998 at Ajou university hospital. First 3 cases were performed with a sing1e plane implant guided by digital palpation. Because of inadequate isodose coverage in the tumor volume in first 3 cases, we designed and constructed interstitial vaginal applicator for volume implant to improve tumor dose distribution and homogeneity while sparing the surrounding normal tissue. Our applicators consist of vaginal obturator and perineal template that made of the clear acrylamide and dental mold material$(Provil^{(R)})$. The applicators were customized individually according to the tumor size and its location Both HDR and LDR irradiation were given with these applicators accomodating 6 Fr needles(Microselectron Nucletron). The pretreatment planning prior to actual implant was performed whenever possible. Results : Needles can be inserted easily and evenly into the tumor volume through the holes of templates, requiring less efforts and time for the implant procedure. Our applicators made of materials available from commercial vendors. These have an advantage that require easy procedure, and spend relatively short time to construct. Also it was possible to fabricate applicators to individualize according to the tumor size and its location and to achieve the ideal isodose coverage. We found an accurate needle arrangement and ideal dose distribution through the CT scan that was obtained in 3 cases after needle implant. Three patients with primary cervical and vaginal cancers were controlled locally at final follow up. But all recurrent cases failed to do so. Conclusion : The authors introduce inexpensive, simple interstitial vaginal templates which were self-designed and constructed using materials available from commercial vendors such as acrylanide and dental mold material $(Provil^{(R)})$.

  • PDF

Effect of the Number and Location of Implants on the Stress Distribution in Three-unit Fixed Partial Denture: A Three-Dimensional Finite Element Analysis (임플란트 고정성 보철물에서 수와 식립위치 변화에 따른 골과 임플란트에서의 응력분포에 관한 3차원 유한요소법적 연구)

  • Lee, Woo-Hyun;Lim, Jong-Hwa;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.3
    • /
    • pp.221-239
    • /
    • 2010
  • Bone loss may occur depending on the loading conditions. careful treatment planning and prosthetic procedures are very important factors for the proper distribution of stress. Evaluate the stress distributions according to numbers and location of implants in three-unit fixed partial dentures. A mandible missing the right second premolar, first molar and second molar was modeled. Using the CT data. we modeled a mandible with a width of 15mm, a height of 20mm and a length of 30mm, 2mm-thickness cortical bone covering cancellous bone mallow. An internal type implant and A solid type abutment was used. A model with 3 implants placed in a straight line, offset 1.5 mm buccally, offset 1.5 mm lingually and another model with 3 implants offset in the opposite way were prepared. And models with 2 implants were both end support models, a mesial cantilever model and a distal cantilever model. Three types of loading was applied; a case where 155 N was applied solely on the second premolar, a case where 206 N was applied solely on the second molar and a case where 155 N was applied on the first premolar and 206 N was applied on the first and second molar. For all the cases, inclined loads of 30 degrees were applied on the buccal cusps and vertical loads were applied on the central fossas of the teeth. Finite element analysis was carried out for each case to find out the stress distribution on bones and implants. This study has shown that prostheses with more implants caused lower stress on bones and implants, no matter what kind of load was applied. Furthermore, it was found out that inclined loads applied on implants had worse effects than vertical loads. Therefore, it is believed that these results should be considered when placing implants in the future.