• Title/Summary/Keyword: Dental CT

Search Result 513, Processing Time 0.029 seconds

Flapless implant placement with digital 3D imaging and planning system in fully edentulous patient: A case report and 5-year follow-up (완전무치악 환자에서 디지털 가이드 수술 방식을 이용한 무피판절개 임플란트 식립증례: 증례보고 및 5년 추적관찰)

  • Shin, Mi-sun;Paek, Janghyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.312-320
    • /
    • 2019
  • One of the fastest growing segments of implant dentistry is the utilization of computed tomography (CT) scan data and treatment planning software in conjunction with guided surgery for implant reconstruction cases. Computer assisted planning systems and associated surgical templates have established a predictable, esthetic, functional technique for placing and restoring implants. Especially, a philosophy of restoratively driven implant placement has been generally adopted. Recently, a variety of commercial dental fields have released their scanning and fabricating protocols and methods for restorations. This process is still being investigated and developed for the most precise and predictable outcome. This case report describes a female patient who wanted dental implants in fully edentulous areas. Restoratively driven implant placements were performed with surgical guide and the patient was fully satisfied with the clinical results, and at 5-year post restorative follow-up assessment, both implant and prosthesis were proved clinical success.

Removal Torque and Histomorphometric Investigation of Surface Modified Commercial Implants: An Experimental Study in the Rabbit Tibia (상용화된 치과용 임플란트의 뒤틀림 제거력 및 조직학적 분석 연구: 가토 경골에서의 연구)

  • Park, Jong-Hyun;Kim, Dae-Gon;Cho, Lee-Ra;Park, Chan-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.1
    • /
    • pp.41-56
    • /
    • 2008
  • The methods of surface modification of commercial implants were various according to the manufacturer. Surface modification of implant may produce diverse physical and chemical surface characteristics resulted from the treatment method and treatment condition. As a result, the bone response might be different. Even though surface modified implants have been used clinically, most researches are focusing on the bone response of surface modified implants comparing to machined implants rather than surface modified commercial implants. This study compare and analyze bone responses of 4 surface modified commercial implants with different shapes and surfaces. Eighty surface modified commercial implants with 4 different surface characteristics were installed in the tibia of white Newzealand rabbits. Biomechanical stability tests and histomorphometric evaluation were done. The results were as follows: 1. Surface modified commercial implants showed stable osseointegration at 6 weeks after installation. 2. Histomorphometric evaluation showed that there was no significant differences in bone to implant contact among 4 different commercial titanium implants. In comparing the implants with different shape the measurement of bone growth in subcortical area would be more reliable than entire bone to implant contact length. 3. Resonance Frequency Analysis showed that there was no significant differences among 4 types of implants, even though they were significantly different in installation. 4. There was significant differences in interfacial shear strength among 4 type of implants. 5. It is difficult to observe accurate bone to implant interface using Micro-CT. However, it is possible to measure the entire contact length of the implant to the bone.

Analyses Using Micro-CT Scans and Tissue Staining on New Bone Formation and Bone Fusion According to the Timing of Cranioplasty via Frozen Autologous Bone Flaps in Rabbits : A Preliminary Report

  • Shin, Hee Sup;Lee, Deok-Won;Lee, Seung Hwan;Koh, Jun Seok
    • Journal of Korean Neurosurgical Society
    • /
    • v.57 no.4
    • /
    • pp.242-249
    • /
    • 2015
  • Objective : The timing of cranioplasty and method of bone flap storage are known risk factors of non-union and resorption of bone flaps. In this animal experimental study, we evaluated the efficacy of cranioplasty using frozen autologous bone flap, and examined whether the timing of cranioplasty after craniectomy affects bone fusion and new bone formation. Methods : Total 8 rabbits (male, older than 16 weeks) were divided into two groups of early cranioplasty group (EG, 4 rabbits) and delayed cranioplasty group (DG, 4 rabbits). The rabbits of each group were performed cranioplasty via frozen autologous bone flaps 4 weeks (EG) and 8 weeks (DG) after craniectomy. In order to obtain control data, the cranioplasty immediate after craniectomy were made on the contralateral cranial bone of the rabbits (control group, CG). The bone fusion and new bone formation were evaluated by micro-CT scan and histological examination 8 weeks after cranioplasty on both groups. Results : In the micro-CT scans, the mean values of the volume and the surface of new bone were $50.13{\pm}7.18mm^3$ and $706.23{\pm}77.26mm^2$ in EG, $53.78{\pm}10.86mm^3$ and $726.60{\pm}170.99mm^2$ in DG, and $31.51{\pm}12.84mm^3$ and $436.65{\pm}132.24mm^2$ in CG. In the statistical results, significant differences were shown between EG and CG and between DG and CG (volume : p=0.028 and surface : p=0.008). The histological results confirmed new bone formation in all rabbits. Conclusion : We observed new bone formation on all the frozen autologous bone flaps that was stored within 8 weeks. The timing of cranioplasty may showed no difference of degree of new bone formation. Not only the healing period after cranioplasty but the time interval from craniectomy to cranioplasty could affect the new bone formation.

Morphological difference of symphysis according to various skeletal types using cone-beam computed tomography (안면골격 유형에 따른 하악 전치 치조골의 형태 차이: Cone-beam CT를 이용한 정량적 평가)

  • Kwon, Hyun-Jin;Chun, Youn-Sic;Kim, Min-Ji
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.3
    • /
    • pp.215-222
    • /
    • 2014
  • Purpose: The aim of this study was to investigate differences between the morphology of the mandibular symphysis and four facial skeletal types. Materials and Methods: 40 cone-beam computed tomographies were selected and classified in to 4 groups according to their vertical and anterior-posterior skeletal patterns. The bone volume ($mm^3$) of the symphysis, the cross sectional area corresponding to the 4 mandibular incisors' axis: the cross sectional area of total bone ($mm^2$), the area of the cancellous bone ($mm^2$) and the thickness (mm) of labial and lingual alveolar bone at 2 mm, 3 mm under the cemento-enamel junction (CEJ) were measured. General linear model (GLM), Kruskal-Wallis test and Tukey honestly significant difference (HSD) test were subsequently used for statistical analysis. Results: The lingual cortical bone thickness of the lateral incisors at 2, 3 mm under CEJ was greater in the Class I low angle group than the other 3 groups (P < 0.05). There were no statistically significant differences in the volume of the mandibular incisor bony support, cross-sectional area of total bone and cancellous bone at the mandibular incisor' axis. Conclusion: Patients in Class I, low angle group have a thicker lingual mandibular symphysis than Class I, high angle patients.

Evaluation of the Accuracy of Distance Measurements on 3D Volume-rendered Image of Human Skull Using Multi-detector CT: Effects of Acquisition Section Thickness and Reconstruction Section Thickness

  • Haijo Jung;Kim, Hee-Joung;Lee, Sang-Ho;Kim, Dong-Wook;Soonil Hong;Kim, Dong-Hyeon;Son, Hye-Kyung;Wonsuk Kang;Kim, Kee-Deog
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.457-460
    • /
    • 2002
  • The image quality of three-dimensional (3D) images has been widely investigated by the qualitative analysis method. A need remains for an objective and quantitative method to assess the image quality of 3D volume-rendered images. The purpose of this study was to evaluate the quantitative accuracy of distance measurements on 3D volume-rendered images of a dry human skull by using multi-detector computed tomography (MDCT). A radiologist measured five times the twenty-one direct measurement line items composed among twelve reference points on the skull surface with a digital vernier caliper. The water filled skull specimen was scanned with a MDCT according to the section thicknesses of 1.25, 2.50, 3.75, and 5.00 mm for helical (high quality; pitch 3:1) scan mode. MDCT data were reconstructed with its acquisition section thickness and with 1.25 mm section thickness for all scans. An observer also measured seven times the corresponding items on 3D volume-rendered images with measuring tools provided by volumetric analysis software. The quantitative accuracy of distance measurements on the 3D volume-rendered images was statistically evaluated (p-value < 0.05) by comparatively analyzing these measurements with the direct distance measurements. The accuracy of distance measurements on the 3D volume-rendered MDCT images acquired with 1.25, 2.50, 3,75 and 5.00 mm section thickness and reconstructed with its section thickness were 48%, 33%, 23%, and 14%, respectively. Meanwhile, there were insignificant statistical differences in accuracy of distance measurements among 3D volume-rendered images reconstructed with 1.25 mm section thickness for the each acquisition section thickness. MDCT images acquired with thick section thickness and reconstructed with thin section thickness in helical scan mode should be effectively used in medical planning of 3D volume-rendered images. The quantitative analysis of distance measurement may be a useful tool for evaluating the quantitative accuracy and the defining optimal parameters of 3D volume-rendered CT images.

  • PDF

Association Analysis of Single Nucleotide Polymorphisms in miR-146a and miR-196a2 on the Prevalence of Cancer in Elderly Japanese: A Case-Control Study

  • Parlayan, Cuneyd;Ikeda, Shinobu;Sato, Noriko;Sawabe, Motoji;Muramatsu, Masaaki;Arai, Tomio
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.5
    • /
    • pp.2101-2107
    • /
    • 2014
  • Background: Single nucleotide polymorphisms (SNPs) affecting microRNA (miR) sequences may influence carcinogenesis. Our current study primarily aimed to confirm previously conducted association studies between rs2910164 found on miR-146a, and rs11614913 located on miR-196a2 polymorphisms and cancer phenotypes in the Japanese elderly population. rs2910164 (G/C) and rs11614913 (T/C) polymorphisms were determined by genotyping on the samples collected from 1,351 consecutive autopsy cases registered in the Japanese SNPs for geriatric research (JG-SNP) data base. Cancer samples were systematically reviewed, pathologically verified and assessed with respect to miR-146a and miR-196a2 genotypic variation. The current study covered 726 males and 625 females with a mean age of $80.3{\pm}8.9$ years. The study included 524 subjects without cancer and 827 subjects with at least one type of cancer, such as gastric (n=160), lung (n=148), colorectal (n=116) or others. Males with cancers (n=467) were more numerous than females (n=360). Both rs11614913 (CT: TT adjusted odds ratio (OR) 95% confidence interval (95%CI)=0.98 (0.75-1.28), p=0.873, CC: TT adjusted OR (95%CI)=1.06 (0.76-1.47), p=0.737, CT+CC: TT, adjusted OR (95%CI)=0.99 (0.77-1.29), p=0.990), and rs2910164 (CG: CC adjusted OR (95%CI)=1.12 (0.87-1.44), p=0.383, GG: CC adjusted OR (95%CI)=1.03 (0.71-1.48), p=0.887, CG+GG: CC adjusted OR (95%CI)=1.10 (0.87-1.39), p=0.446) polymorphisms did not show significant association with overall cancer in all subjects. However, "CC" genotype in rs11614913 polymorphism was significantly associated with increased gastric cancer (n=160) in all subjects (CC: CT+TT, adjusted OR (95%CI)=1.50 (1.02-2.22), p=0.040). We found that rs11614913 and rs2910164 do not pose general cancer risk, but rs11614913 may influence gastric cancer in Japanese elderly population. Confirmation of our study results requires further investigations with larger subject populations.

THE STUDY BY USING THE COMPUTERIZED TOMOGRAPHY IMAGING IN ORDER TO ACCESS TO MANDIBULAR FORAMEN WHILE INFERIOR ALVEOLAR NERVE ANESTHESIA (하치조신경 마취시 하악공으로의 접근을 위한 전산화단층촬영을 통한 방사선적 연구)

  • Kim, Ji-Kwang;Gu, Hong;An, Jin-Suk;Kook, Min-Suk;Park, Hong-Ju;Oh, Hee-Kyun;Cho, Jin-Hyoung
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.32 no.6
    • /
    • pp.566-574
    • /
    • 2006
  • Purpose : This study was performed to provide an anatomical information of the mandibular ramus for the successful inferior alveolar nerve block. Three dimensional images were reconstructed from the computerized tomography (CT) and the anatomical evaluation of the mandibular ramus was done. Materials and methods : Sixty-four patients who had been taken the facial CT scans from 2000, Jan to 2003, June was selected. The patients who had the anterior or posterior teeth misssing, edentulous ridge, and jaw fracture were excepted. In the occulusal plane, the lingual surface angle (LSA) between the mid-sagittal plane and the mandibular molar lingual surface from the 2nd premolar to the 2nd molar, the inner ramal surface angle (IRSA), the maximum inner ramal surface angle (MxIRSA), and the outer ramal surface angle (ORSA) to the-mid sagittal plane were measured. The inner ramal surface angle in the ligular tip level (IRSA-L) and the outer ramal surface angle in the ligular tip level (ORSA-L), the ramal length (RL), and the anterior ramal length (ARL) were also measured in the lingular tip level. Results : In the lingular tip level, the mean IRSA-L and ORSA-L were $28.6{\pm}6.3^{\circ}$ and $17.9{\pm}4.9^{\circ}$ respectively. The larger was the IRSA, the larger was the ORSA. In the lingular tip level, the mean ramal length was 35.8${\pm}$3.4 mm. The larger was the IRSA-L, the shorter was the ramal length. On the lingular tip level, the mean anterior ramal length from anterior ramus to lingular tip was 19.6${\pm}$3.3 mm. when the ramal length was longer, the anterior ramal length was also longer. On the lingular tip level, there was positive correlation vetween the IRSA and the ORSA, negative correlation between the IRSA and the ramal length, and positive correlation between the ramal length and the lingular tip level to the anterior ramus. There was no statistical meaning of data between sex and age. Conclusion : In the clinical view of the results so far achieved, if the direction of needle is closer to posterior it is able to contact bone on lingular tip when the internal surface of ramus is wided outer.

The Influence of Microwave Sintering Process on the Adaptation of CAD/CAM Zirconia Core (마이크로 웨이브 소결 과정이 CAD/CAM 지르코니아 코아의 적합도에 미치는 영향)

  • Kim, Keun Bae;Kim, Jee Hwan;Lee, Keun-Woo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.2
    • /
    • pp.95-107
    • /
    • 2009
  • The purpose of this research was to examine the fitness of zirconia cores that were made by different sintering methods; generic electricity furnace and microwave furnace. Firstly, 12 cores for each group were made by using each different sintering process and attached them to a metal die with silicon. The internal and marginal gap of sintered zirconia was measured by using Skyscan 1076 micro-CT, then it was reorganized by CT-An software. To each samples, we extracted B-L image, M-D image of cutting side, and cross-sectional side of tooth long axis and calculated the mean value of marginal, axial, and occlusal gap each side. Results: 1. The mean marginal gap of sintered zirconia was $36.20{\mu}m$ for EVE, $47.67{\mu}m$ for LAV, $52.47{\mu}m$ for DEN, and $54.63{\mu}m$ for CER. 2. For the axial wall, the research showed the largest value of $63.49{\mu}m$ for EVE, but there were no statistical significance. 3. In related to the occlusal internal measurement, DEN showed the smallest value ($77.06{\mu}m$), EVE and CER showed significantly high value. From this study, it is suggested that CAD/CAM zirconia core which was made in the process of microwave sintering has clinically acceptable values in marginal and internal gap.

Evaluation of marginal leakage of bulk fill flowable composite resin filling with different curing time using micro-computed tomography technology (Bulk fill 유동성 복합레진의 변연 누출에서 다른 중합시간의 영향에 대해 마이크로시티를 이용한 평가)

  • Kim, Eun-Ji;Lee, Kyu-Bok;Jin, Myoung-Uk
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.3
    • /
    • pp.184-193
    • /
    • 2016
  • Purpose: To evaluate marginal leakage of bulk fill flowable composite resin filling with different curing time by using microcomputed tomography technology. Materials and Methods: 30 previously extracted human molars were randomly divided into 6 groups based upon restorative system and different curing time. Class II cavities (vertical slot cavities) were prepared. An individual metallic matrix was used to build up the proximal wall. The SonicFill or SureFil SDR flow was inserted into the preparation by using 1 bulk increment, followed by light polymerization for different curing times. The different exposure times were 20, 40, and 60 seconds. All specimens were submitted to 5,000 thermal cycles for artificial aging. Micro-CT scanning was performed by using SkyScan 1272. One evaluator assessed microleakage of silver nitrated solution at the resin-dentin interface. The 3D image of each leakage around the restoration was reconstructed with CT-Analyser V.1.14.4. The leakage was analyzed with the Mann-Whitney test. Results: Significant differences were observed between the light curing times, but no significant differences were found between the bulk fill composite resins. Increasing in the photoactivation time resulted in greater microleakage in all the experimental groups. Those subjected to 60 seconds of light curing showed higher microleakage means than those exposed for 20 seconds and 40 seconds. Conclusion: Increasing the photoactivation time is factor that may increase marginal microlekage of the bulk fill composite resins. Further, micro-CT can nondestructively detect leakage around the resin composite restoration in three dimensions.

THE STUDY ON COURSE OF THE INFERIOR ALVEOLAR CANAL IN THE MANDIBULAR RAMUS USING CONEBEAM CT (하악지에서의 하치조신경관 주행에 대한 Conebeam CT를 이용한 연구)

  • Kim, Hyong-Woo;Kwon, Kyung-Hwan;Min, Seung-Ki;Oh, Seung-Hwan;Chee, Young-Deok;Koh, Se-Wook;Lee, Jae-Hwan;Ohn, Byung-Hun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.31 no.5
    • /
    • pp.386-393
    • /
    • 2009
  • Objectives: This study was performed to evaluate course of the inferior alveolar canal in the mandibular ramus and to find safety zone when ramal bone is harvested. Patients and Methods: From January, 2009 to February, 2009, the 20 patients who visited in the Department of Oral and Maxillofacial Surgery, Sanbon Dental Hospital. Wonkwang University and the Conebeam CT was taken of various chief complaints, were selected. The patients who had left and right mandibular first molar and incisor missing, jaw fracture and bone pathology were excluded. The R point was defined as the point which occlusal plane was crossed to the mandibular anterior ramus(external oblique ridge). In the cross-sectional coronal and axial views, the inferior alveolar canal position to the R point, buccal bone width(BW), alveolar crest distance(ACD), distance from alveolar crest to occlusal plane(COD) and inferior alveolar canal to sagittal plane(CS) were measured and horizontal distance(HD), vertical distance(VD) and nearest distance(ND) were measured. Results: The inferior alveolar canal is located $6.19{\pm}1.21\;mm$ from the R point. Horizontal distance from the R point were $13.07{\pm}2.45\;mm$, vertical distance from the R point were $14.24{\pm}2.41\;mm$ and nearest distance from the R point were $10.12{\pm}1.76\;mm$. The course of the inferior alveolar canal was positioned within $0.61{\pm}0.68\;mm$. The distance from external buccal bone to the inferior alveolar canal was increased from the R point anteriorly. Conclusions: It is considered that the mandibular ramus from the R point to 10 mm anteriorly can be harvested safely at ramal bone grafting.