• 제목/요약/키워드: Density monitoring system

검색결과 203건 처리시간 0.026초

Field monitoring of wind effects on a super-tall building during typhoons

  • Zhi, Lunhai;Li, Q.S.;Wu, J.R.;Li, Z.N.
    • Wind and Structures
    • /
    • 제14권3호
    • /
    • pp.253-283
    • /
    • 2011
  • This paper presents the field measurement results of wind effects on a super-tall building (CITIC Plaza, 391 m high) located in Guangzhou. The field data such as wind speed, wind direction and acceleration responses were simultaneously and continuously recorded from the tall building by a wind and vibration monitoring system during two typhoons. The typhoon-generated wind characteristics including turbulence intensity, gust factor, peak factor, turbulence integral length scale and power spectral density of fluctuating wind speed were presented and discussed. The dynamic characteristics of the tall building were determined based on the field measurements and compared with those calculated from a 3D finite element model of the building. The measured natural frequencies of the two fundamental sway modes of the building were found to be larger than those calculated. The damping ratios of the building were evaluated by the random decrement technique, which demonstrated amplitude-dependent characteristics. The field measured acceleration responses were compared with wind tunnel test results, which were found to be consistent with the model test data. Finally, the serviceability performance of the super-tall building was assessed based on the field measurement results.

Stationary and nonstationary analysis on the wind characteristics of a tropical storm

  • Tao, Tianyou;Wang, Hao;Li, Aiqun
    • Smart Structures and Systems
    • /
    • 제17권6호
    • /
    • pp.1067-1085
    • /
    • 2016
  • Nonstationary features existing in tropical storms have been frequently captured in recent field measurements, and the applicability of the stationary theory to the analysis of wind characteristics needs to be discussed. In this study, a tropical storm called Nakri measured at Taizhou Bridge site based on structural health monitoring (SHM) system in 2014 is analyzed to give a comparison of the stationary and nonstationary characteristics. The stationarity of the wind records in the view of mean and variance is first evaluated with the run test method. Then the wind data are respectively analyzed with the traditional stationary model and the wavelet-based nonstationary model. The obtained wind characteristics such as the mean wind velocity, turbulence intensity, turbulence integral scale and power spectral density (PSD) are compared accordingly. Also, the stationary and nonstationary PSDs are fitted to present the turbulence energy distribution in frequency domain, among which a modulating function is included in the nonstationary PSD to revise the non-monotonicity. The modulated nonstationary PSD can be utilized to unconditionally simulate the turbulence presented by the nonstationary wind model. The results of this study recommend a transition from stationarity to nonstationarity in the analysis of wind characteristics, and further in the accurate prediction of wind-induced vibrations for engineering structures.

Thermomechanical and electrical resistance characteristics of superfine NiTi shape memory alloy wires

  • Qian, Hui;Yang, Boheng;Ren, Yonglin;Wang, Rende
    • Smart Structures and Systems
    • /
    • 제30권2호
    • /
    • pp.183-193
    • /
    • 2022
  • Structural health monitoring and structural vibration control are multidisciplinary and frontier research directions of civil engineering. As intelligent materials that integrate sensing and actuation capabilities, shape memory alloys (SMAs) exhibit multiple excellent characteristics, such as shape memory effect, superelasticity, corrosion resistance, fatigue resistance, and high energy density. Moreover, SMAs possess excellent resistance sensing properties and large deformation ability. Superfine NiTi SMA wires have potential applications in structural health monitoring and micro-drive system. In this study, the mechanical properties and electrical resistance sensing characteristics of superfine NiTi SMA wires were experimentally investigated. The mechanical parameters such as residual strain, hysteretic energy, secant stiffness, and equivalent damping ratio were analyzed at different training strain amplitudes and numbers of loading-unloading cycles. The results demonstrate that the detwinning process shortened with increasing training amplitude, while austenitic mechanical properties were not affected. In addition, superfine SMA wires showed good strain-resistance linear correlation, and the loading rate had little effect on their mechanical properties and electrical resistance sensing characteristics. This study aims to provide an experimental basis for the application of superfine SMA wires in engineering.

Alternative Alert System for Cyanobacterial Bloom, Using Phycocyanin as a Level Determinant

  • Ahn, Chi-Yong;Joung, Seung-Hyun;Yoon, Sook-Kyoung;Oh, Hee-Mock
    • Journal of Microbiology
    • /
    • 제45권2호
    • /
    • pp.98-104
    • /
    • 2007
  • Chlorophyll ${\alpha}$ concentration and cyanobacterial cell density are regularly employed as dual criteria for determinations of the alert level for cyanobacterial bloom. However, chlorophyll ${\alpha}$ is not confined only to the cyanobacteria, but is found universally in eukaryotic algae. Furthermore, the determination of cyanobacterial cell counts is notoriously difficult, and is unduly dependent on individual variation and trained skill. A cyanobacteria-specific parameter other than the cell count or chlorophyll ${\alpha}$ concentration is, accordingly, required in order to improve the present cyanobacterial bloom alert system. Phycocyanin has been shown to exhibit a strong correlation with a variety of bloom-related factors. This may allow for the current alert system criteria to be replaced by a three-stage alert system based on phycocyanin concentrations of 0.1, 30, and $700\;{\mu}g/L$. This would also be advantageous in that it would become far more simple to conduct measurements without the need for expensive equipment, thereby enabling the monitoring of entire lakes more precisely and frequently. Thus, an alert system with superior predictive ability based on highthroughput phycocyanin measurements appears feasible.

Broadband energy harvester for varied tram vibration frequency using 2-DOF mass-spring-damper system

  • Hamza Umar;Christopher Mullen;Soobum Lee;Jaeyun Lee;Jaehoon Kim
    • Smart Structures and Systems
    • /
    • 제32권6호
    • /
    • pp.383-391
    • /
    • 2023
  • Energy harvesting in trams may become a prevalent source of passive energy generation due to the high density of vibrational energy, and this may help power structural health monitoring systems for the trams. This paper presents a broadband vibrational energy harvesting device design that utilizes a varied frequency from a tram vehicle using a 2 DOF vibrational system combined with electromagnetic energy conversion. This paper will demonstrate stepwise optimization processes to determine mechanical parameters for frequency tuning to adjust to the trams' operational conditions, and electromagnetic parameters for the whole system design to maximize power output. The initial optimization will determine 5 important design parameters in a 2 DOF vibrational system, namely the masses (m1, m2 (and spring constants (k1, k2, k3). The second step will use these parameters as initial guesses for the second optimization which will maintain the ratios of these parameters and present electrical parameters to maximize the power output from this system. The obtained values indicated a successful demonstration of design optimization as the average power generated increased from 1.475 mW to 17.44 mW (around 12 times).

Effects of Windbreak Planting on Crop Productivity for Agroforestry Practices in a Semi-Arid Region

  • Jo, Hyun-Kil;Park, Hye-Mi
    • Journal of Forest and Environmental Science
    • /
    • 제33권4호
    • /
    • pp.348-354
    • /
    • 2017
  • Agroforestry has been practiced in arid and semi-arid regions for the purposes of preventing desertification and to increase income for locals. However, the intended effects of such practices have been limited due to strong winds and aridity. This study undertook multi-year monitoring of the productivity of income crops associated with windbreak planting in a semi-arid region of Mongolia, and explored strategies of windbreak planning to enhance the multi-purpose effects of agroforestry practices. The tree crown density of windbreak planting was on average 40% in one year after planting and 65% 2-3 years after, and thereby windspeeds were reduced by about 30% and 54%, respectively. Average windspeed reductions at leeward distances from the windbreak planting were approximately 60% within 3H (H=tree height), 50% at 5H, and 42% at 7-9H, presenting a pattern in which the farther the distance the less the reduction in windspeeds. The windbreak planting increased crop productivity by up to 6.8 times, compared to the productivity absent of windbreaks. Increases in the crown density as stated above resulted in increases of crop productivity by up to 3.6 times. Based on such results, this study proposed a model of windbreak planning as a typical land-use system of border windbreak planting or alternate windbreak planting of combining trees and income crops. The model also included tree planting with a crown density of 60% and allocation of income crops within a leeward distance of 5 times the height of the trees to reduce windspeeds by about 50%. The results from this study are applicable to practicing agroforestry not only at the study site but also in other regions worldwide where strong winds and aridity are problematic.

영상기반 축사 내 육계 검출 및 밀집도 평가 연구 (Study on image-based flock density evaluation of broiler chicks)

  • 이대현;김애경;최창현;김용주
    • 한국정보전자통신기술학회논문지
    • /
    • 제12권4호
    • /
    • pp.373-379
    • /
    • 2019
  • 본 연구에서는 실시간 육계 복지관리를 위해 영상 기반의 육계 군집 모니터링을 수행하였으며, 촬영된 영상 내육계 영역을 검출하고 좌표변환을 이용한 지면 투영과 밀집도를 평가하였다. 평사 구조의 육계사에서 광역 범위의 육계 군집을 촬영하였으며 육계 영역은 카메라로부터 수집된 RGB 영상을 HSV 모델로 변환한 후 임계치 처리 및 군집화를 통해 검출하였다. 영상처리를 통해 검출된 육계 영역은 카메라-월드 좌표계 변환을 이용하여 지면에 투영한 후 실제 면적을 계산하였으며, 계산된 면적을 이용하여 밀집도를 평가하였다. 영역 검출 결과 상대오차 및 IoU가 평균 5%, 0.81로 각각 계산되었으며, 좌표변환을 통한 실제 면적은 약 7%의 오차 수준으로 평가되었다. 실제 면적 내 육계영역의 비율을 이용하여 밀집도를 계산하였으며 평균 80% 수준으로 나타났다. 영역 검출의 경우 작거나 멀리 존재하는 면적에 대해서는 검출 성능이 다소 떨어졌으며, 실제 면적 평가는 축사 내 구조물 등에 따른 오차가 관찰되었다. 따라서 본 기술을 축사에 적용하기 위해서는 다양한 데이터 기반의 알고리즘의 검출 성능 향상 및 마커 등을 이용한 기준정보 추가 설치가 필요할 것으로 판단된다.

실시간 네트워크 침입탐지 시스템을 위한 아웃라이어 클러스터 검출 기법 (An Outlier Cluster Detection Technique for Real-time Network Intrusion Detection Systems)

  • 장재영;박종명;김한준
    • 인터넷정보학회논문지
    • /
    • 제8권6호
    • /
    • pp.43-53
    • /
    • 2007
  • 최근의 네트워크 침입탐지 시스템은 기존의 시그너처(또는 패턴) 기반 탐지 기법에 비정상행위 탐지 기법이 새롭게 결합되면서 더욱 발전되고 있다. 일반적으로 시그너처 기반 침입 탐지 시스템들은 기계학습 알고리즘을 활용함에도 불구하고 사전에 이미 알려진 침입 패턴만을 탐지할 수 있었다. 이상적인 네트워크 침입탐지 시스템을 구축하기 위해서는 침입 패턴이 저장된 시그너처 데이터베이스를 항상 최신의 정보로 유지해야 한다. 따라서 시스템은 유입되는 네트워크 데이터를 모니터링하고 분석하는 과정에서 새로운 공격에 대한 시그너처를 생성할 수 있는 기능이 필요하다. 본 논문에서는 이를 위해 밀도(또는 영향력) 함수를 이용한 새로운 아웃라이어 클러스터 검출 알고리즘을 제안한다. 제안된 알고리즘에서는 네트워크 침입 패턴을 하나의 객체가 아닌 유사 인스턴스들의 집합 형태인 아웃라이어 클러스터로 가정하였다. 본 논문에서는 KDD 1999 Cup 침입탐지 데이터 집합을 이용한 실험을 수행하여, 침입이 자주 발생하는 상황에서 본 논문의 방법이 유클리디언 거리를 이용한 기존의 아웃라이어 탐지 기법에 비해서 좋은 성능을 보임을 증명하였다.

  • PDF

Testing a Small Scale Aseptic System for Milk in Plastic Bottles

  • Petrus, Rodrigo Rodrigues;Faria, Jose de Assis Fonseca
    • Food Science and Biotechnology
    • /
    • 제16권1호
    • /
    • pp.18-22
    • /
    • 2007
  • The objective of this study was to develop and assess the performance of an aseptic system for liquid milk contained in plastic bottles, from a small-scale production standpoint. Commercial sterility tests conducted on the bottled milk were utilized in our assessments of the system, via the identification and monitoring of the principal points of the process. Four 150 L batches of milk with pH values of approximately 6.7 were heat-processed at between 137 and $143^{\circ}C$ for 10 see in a plate heat exchanger, and then aseptically transferred to 500 mL high-density polyethylene (HOPE) bottles, in an ISO class 7 clean room. The aseptic condition of the bottles was achieved via 10 see of rinsing with a mixture containing 0.5% peracetic acid and 0.8% hydrogen peroxide at $30^{\circ}C$, followed by another rinse with sterile water. Of the 4 batches processed, 2 were determined to exhibit commercial sterility, on the basis of the physical-chemical and microbiological criteria adopted. It was concluded that some adjustment of the processing line was required in order to achieve full commercial sterility for all processes. The aseptic system developed and assessed in this study was demonstrated to have great potential for the processing and transferring of milk into plastic bottles, from a small-scale production standpoint.

지상 고밀도 관측 시스템을 이용한 대구의 여름철 고온현상 조사 (Investigation of Urban High Temperature Phenomenon in Summer using the High Density Ground Monitoring System in Daegu Metropolitan Area)

  • 김상헌;조창범;김해동
    • 한국환경과학회지
    • /
    • 제23권9호
    • /
    • pp.1619-1626
    • /
    • 2014
  • We analyzed diurnal variations in the surface air temperature using the high density urban climate observation network in Daegu metropolitan city, the representative basin-type city in Korea, in summer, 2013. We used a total of 28 air temperature observation points data(16 thermometers and 12 AWSs). From the distribution of monthly average air temperature, air temperature at the center of Daegu was higher than the suburbs. Also, the days of daily minimum air temperature more than or equal to $25^{\circ}C$ and daily maximum air temperature more than or equal to $35^{\circ}C$ at the schools near the center of Daegu was more than those at other schools. This tendency appeared more clearly on the days of daily minimum air temperature more than or equal to $25^{\circ}C$. Also, the air temperature near the center of the city was higher than that of the suburbs in the early morning. Thus it was indicated that the air temperature was hard to decrease as the bottom of the basin. From these results, the influence of urbanization to the formation of the daily minimum temperature in Daegu was indicated.