• 제목/요약/키워드: Density evaluation

검색결과 1,940건 처리시간 0.027초

고층고밀 아파트단지의 노후도 평가지표 개발 (A Study on the Evaluating Indicators of the Level of Deterioration in High-rise and high-density Apartments)

  • 조성희;이태경
    • 한국주거학회논문집
    • /
    • 제20권4호
    • /
    • pp.131-142
    • /
    • 2009
  • High-rise and high-density apartment complexes have been built and supplied on a large scale in the 1st period of the New Town project in metropolitan areas since the late 1980s. Now It has become necessary to improve those apartment complexes, which have serious deterioration problems for aging more than about 20 years accompanying simultaneity and a large scale. The purpose of this research is to develop the evaluating indicators to measure the level of deterioration of apartments inclusively and practically in order to regenerate apartments as sustainable residential environments. This study is composed of the following four parts; (a) establishing the conceptual model of evaluation of apartment deterioration, (b) selecting evaluation items, (c) constituting evaluation measurement, and(d)weighting evaluation indicators. First, deterioration of apartments was conceptualized by physical. social, and economical aspects in terms of sustainable development and proposed the conceptual model of hierarchy structure of evaluation of apartment deterioration by literature reviews. Second, evaluating items were selected based on literature reviews of existing indicators and preceding studies about apartments of Korea and foreign countries. The evaluating indicators were identified as a total of 77 evaluating items which were composed of three dimensions and 9 attributes on the basis of the conceptual model. They cover comprehensive scope of the apartment such as unit, building, complex, and site. Third, as the measurement, the 5 point ordinal scale measure was suggested. The evaluating measurement including measure standards, measure methods, and measure contents were developed by each evaluating items. Lastly, the weighting of evaluating indicators was analyzed by AHP method conducted by survey on the expert group. Items were identified as high contributors or low contributors. The weighting of these items could suggest several evaluations according to the situation. The evaluation of the level of deterioration can be done by both total evaluation and a specific field of evaluation. In addition, it is easy to grasp deteriorated attributes or dimensions by providing a radar and bar chart showing evaluation results. These evaluating indicators could be a useful tool to grasp actual methods for the regeneration of apartments.

지능밀도를 이용한 정보시스템의 평가 (Evaluation of Information Systems Using Intelligence Density)

  • 김국;송기원
    • 한국품질경영학회:학술대회논문집
    • /
    • 한국품질경영학회 2006년도 춘계학술대회
    • /
    • pp.86-91
    • /
    • 2006
  • Companies had to be more intelligent in order to survive in the rapidly changing environments. We need to make a decision to build the Information System to support their decision making. But, how can we know the new system would be better than the old system in making us intelligent? The answer is we can do it with the concept of Intelligence Density. In this study, Intelligence Density concept will be introduced, and the way how it can be applied to the information system will be presented. I think Intelligence Density should be studiedmoretohelpmanagersmakerightdecisions.

  • PDF

중방식도료의 내식성에 관한 전기화학적 평가 (An Electrochemical Evaluation on the Corrosion Resistance of Heavy Anticorrosive Paint)

  • 성호진;김진경;이명훈;김기준;문경만
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권5호
    • /
    • pp.519-525
    • /
    • 2005
  • An electrochemical evaluation on the corrosion resistance for heavy anticorrosive paint(DFT:25um) was carried out for 5 kinds of heavy anticorrosive paints such as high solid epoxy(HE), solvent free epoxy(SE). tar epoxy(TE), phenol epoxy(PE). and ceramic epoxy(CE). Corrosion current densities obtained by Tafel extrapolation method from anodic and cathodic polarization curves didn't correspond with the values obtained by AC impedance measurement, however, the values of polarization resistance obtained from the cyclic voltammogram showed a good tendency corresponding well with the values of AC impedance measurement. Futhermore there was a good correlation against the corrosion resistance evaluation between passivity current density of the anodic polarization curve and diffusion limiting current density of the cathodic polarization curve. And corrosion resistance increased with corrosion potential shifting to noble direction. From the results discussed above. HE and CE had a relatively good corrosion resistance than other heavy anticorrosive paints.

소규모 플랜트 기자재의 고장밀도함수가 가용도에 미치는 영향 평가 (A Study on the Availability Evaluation with Failure Density Function of Equipment of Small-scale Plant)

  • 이홍철;황인주
    • 한국유체기계학회 논문집
    • /
    • 제19권3호
    • /
    • pp.33-36
    • /
    • 2016
  • The investigation on the verification of availability simulation for small-scale plant has been carried out. This study focuses on the availability variation induced by number of equipment and iteration with failure density function. The equipment classification of small-scale plant and failure type and the methodologies on Monte-Carlo simulation are established. The availability deviation with programs showed under Max. 1.7% for the case of normal function. This method could be used to availability evaluation of small-scale plant, but calibration of the failure density function is necessary for general application.

Fundamental Considerations: Impact of Sensor Characteristics, Application Environments in Wireless Sensor Networks

  • Choi, Dongmin;Chung, Ilyong
    • 한국멀티미디어학회논문지
    • /
    • 제17권4호
    • /
    • pp.441-457
    • /
    • 2014
  • Observed from the recent performance evaluation of clustering schemes in wireless sensor networks, we found that most of them did not consider various sensor characteristics and its application environment. Without considering these, the performance evaluation results are difficult to be trusted because these networks are application-specific. In this paper, for the fair evaluation, we measured several clustering scheme's performance variations in accordance with sensor data pattern, number of sensors per node, density of points of interest (data density) and sensor coverage. According to the experiment result, we can conclude that clustering methods are easily influenced by POI variation. Network lifetime and data accuracy are also slightly influenced by sensor coverage and number of sensors. Therefore, in the case of the clustering scheme that did not consider various conditions, fair evaluation cannot be expected.

유방암 근접치료 시 나노입자의 밀도에 따른 흡수선량 평가 (Evaluation of Absorbed Dose According to Nanoparticle Density During the Breast Cancer Brachytherapy)

  • 이득희;남지희;김정훈
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권2호
    • /
    • pp.131-135
    • /
    • 2019
  • The purpose of this study was to evaluate the efficacy of brachytherapy of breast cancer by dose assessment which a steady increased in Korea women. The dose assessment was performed using the MCNPX program, a MonteCarlo simulation technique. The sources used for brachytherapy was 192Ir. And nanoparticle which used for dose enhancement was gold. The density of nanoparticle was 7, 18 and 30 mg. Evaluation of absorbed dose according to distance is measured at a distance of 30, 50, 100 and 200 cm from the patient. As a result, The breast absorbed dose results increased in proportion to the density of nanoparticle. And the surrounding organs were not significantly different according to the density. But, in some organs, the absorbed dose decreased as the density of nanoparticles increased. Absorbed dose according to the distance was in inverse proportion to distance.

치밀형 유방에서 유방특이감마영상검사의 유용성 평가 (A Study on Comparative Analysis of Mammography and Tc-99m MIBI Scintimammography for Dense Breast)

  • 정은미;김호성
    • 핵의학기술
    • /
    • 제16권1호
    • /
    • pp.76-79
    • /
    • 2012
  • Purpose: This study was to evaluate usefulness of $^{99m}Tc$-MIBI scintimammography for dense breast by comparing concordance in test results between Tc-99m MIBI scintimammography and mammography whose effect was proved the most as an imaging tool depending on breast density and at the same time by examining limitation on evaluation depending on density of breast tissue. [Materials and Methods] In the period from December 2010 to July 2011, this study targeted 150 patients who took both of $^{99m}Tc$-MIBI scintimammography and mammography conducted by using breast gamma camera in this hospital. Breast density was classified to the four levels of pattern 1~4 based on the results of mammography. $^{99m}Tc$-MIBI scintimammography was conducted with the LCC, the RCC, the LMLO, and the RML one minute after intravenous injection of 99mTc-MIBI 7400 MBq (20 mCi) while analysis was made for concordance in test results of $^{99m}Tc$-MIBI scintimammography and mammography. [Results] Among the 150 patients, pattern 1 was found in 3 patients, pattern 2 in 44 patients, pattern 3 in 61 patients, and pattern 4 in 37 patients. There were 5 patients who showed the case where it was impossible to determine density of breast tissue due to foreign body inserted to breast. The concordance ratio of the results between $^{99m}Tc$-MIBI scintimammography and mammography was 95.5% for pattern 2, 95.1% for pattern 3 and 94.6% for pattern 4. This demonstrated that the concordance rate decreased according to the increase in breast density. [Conclusion] When there was limitation on evaluation of breast specific gamma imaging test results due to increased intake in breast tissue or surgical site, the concordance rate was 6.8% for pattern 2, 16.3% for pattern 3 and 18.9% for pattern 4. This demonstrated that the degree of limitation on evaluation of breast specific gamma imaging test results increased according to the increase in breast density.

  • PDF

흉부의 ANALOG-DIGITAL 영상에 대한 비교 평가

  • 장영애;문희석;임한영;오현주;김성수;김영일
    • 대한디지털의료영상학회논문지
    • /
    • 제2권1호
    • /
    • pp.74-82
    • /
    • 1996
  • This paper were studied the evaluation in compare with the conventional and AMBER of analog images, PACS and CR of digital images which were collected every ten sampling chest images with the J.J.Vucicuh chest evaluated chart, and were measured the chest phantom surface dose and the density of several part in chest images. The evaluated numbers were total 22 persons who were 6 persons of the M.D., 6 of the radiotechnological professors and 10 of the radiotechnologists. The obtained results summarized as following : 1. Approaching the optimum standard density of the several part in chest images drew near at the lung round region density in PACS images, the sternum region density in CR and AMBER images, the heart region density in CR AMBER images, the diaphram region density in AMBER and conventional images. 2. The evaluation measured surface dose were appeared orderly lesser dose at the AMBER images (spine 21 mR, lung 2mR, heart 12mR, apex 6mR) than the conventional images(32 mR), CR images(38mR) and PACS images(81mR). 3. The anatomical physical evaluation marks were taken the highest points at CR images(88.3), and orderly PACS images(82), AMBER images(79.2) and conventional images(65.2). 4. It is exposured with lesser surface dose at the analog images, but analog images leaves much room for image quality improvement, and digital images demand for lesser exposure surface dose, although excellent image quality.

  • PDF

Ozone Condensation and Stable Supply by an Adsorption Method

  • Yang, Seong-Ho;Park, Yong-Pil;Lee, Joon-Ung
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 춘계학술대회 논문집 전자세라믹스 센서 및 박막재료 반도체재료 일렉트렛트 및 응용기술
    • /
    • pp.121-125
    • /
    • 2000
  • An ozone condenser by a selective adsorption on the silica gel surface is constructed. Ozone density is evaluated by three methods; ultraviolet absorption, thermal decomposition and Q-mass analyzing methods. Thermal decomposition method is found to be available to the density evaluation from dilute to highly condensed ozone. The highest ozone density condensed by the adsorption method is evaluated to be 97 mol%.

  • PDF

Ozone Dentisity Estimation and Stable Supply in the Growth Process of BSCCO Thin Film

  • Lee, Hee-Kab;Park, Yong-Pil
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 제2회 학술대회 논문집 일렉트렛트 및 응용기술전문연구회
    • /
    • pp.45-49
    • /
    • 2000
  • An ozone condenser by a selective adsorption on the silica gel surface is constructed. Ozone density is evaluated by three methods; ultraviolet absorption, thermal decomposition and Q-mass analyzing methods. Thermal decomposition method is found to be available to the density evaluation from dilute to highly condensed ozone. The highest ozone density condensed by the adsorption method is evaluated to be 97 mol%.

  • PDF