• 제목/요약/키워드: Delivery room

검색결과 192건 처리시간 0.019초

폴리오르소에스터를 이용한 니페디핀의 반고형 이식제제의 제조 및 평가 (Preparation and Evaluation of Semi-Solid Nifedipine Implants of Poly(ortho esters))

  • 이새별;박주애;이승진;김길수
    • Journal of Pharmaceutical Investigation
    • /
    • 제29권2호
    • /
    • pp.93-98
    • /
    • 1999
  • Semi-solid poly(ortho esters) (POE) were prepared to provide bioerodible carriers for sustained drug delivery systems of nifedipine in the treatment of cardiovascular disease. As the POE has viscous behavior at room temperature, a significant advantage of this polymer is that it can be injected without any surgical intervention. The POE was synthesized by a transesterification reaction between 1,2,6-hexanetriol and trimethyl orthoacetate and the nifedipine release from POE was studied in vitro. The release rate of nifedipine decreased with increasing the amount of nifedipine and the diethanolamine dispersed in the polymer. But the excess amounts, above 3%, of diethanolamine retarded the release of nifedipine. In vivo biocompatibility studies were carried out in rats with nifedipine loaded POE. Histopathological analysis showed that nifedipine loaded POE implants were well-tolerated by rats when used subcutaneously. In case of the rats implanted POE containing diethanolamine, tissue necrosis and inflammation were occured. Pharmacokinetic studies of nifedipine loaded POE implants were carried out in rabbits. In all cases, plasma concentrations of nifedipine were maintained over 15 ng/ml for at least 360 hours and biological half $life(t_{1/2})$ and mean residence time(MRT) were increased by addition of diethanolamine.

  • PDF

에폭시/고무 거시계면에서 장시간 절연파괴전압에 대한 연구 (Study on the Long Time Breakdown Voltage in the Macro Interface between Epoxy and Rubber)

  • 박우현;이기식
    • 한국전기전자재료학회논문지
    • /
    • 제15권11호
    • /
    • pp.1003-1008
    • /
    • 2002
  • In this paper, the estimation of lifetime with the various conditions of the interface between toughened epoxy and rubber which are consisting materials of underground power delivery system has been studied. After the measurement of the short time AC interfacial breakdown strength on macro interfaces at room temperature, the breakdown time at several voltages were measured under the constant voltages lower than the short time breakdown voltage. The long time breakdown voltage was calculated by using Inverse Power Law. Two types of interfaces was studied. One was the interface between toughened epoxy and EPDM(Ethylene Prorylene Diene Terpolymer). The other was the interface between toughened epoxy and silicon rubber. Interfacial pressure and roughness of interfaces was determined through the characteristic of short time AC interfacial breakdown strength. Oil condition was no oiled, low viscosity oiled and high viscosity oiled. High viscosity oiled interface between Toughened epoxy and silicon rubber had the best lifetime exponent, 20.69. and the breakdown voltage of this interface after 30 years was evaluated 19.27㎸.

간호대학생의 전공만족도, 진로결정 자기효능감과 진로정체감 관계 (Relations between Satisfaction in Major, Career Decision-making Self-efficacy and Career Identity of Nursing Students)

  • 정점숙;정미조;유일영
    • 한국간호교육학회지
    • /
    • 제20권1호
    • /
    • pp.27-36
    • /
    • 2014
  • Purpose: The purpose of this study was to investigate the relation between satisfaction in major, career decision-making self-efficacy and career identity of nursing students. Methods: Data were collected from 543 students by means of self reported questionnaires about satisfaction in major, career decision-making self-efficacy and career identity from November 26 to 30, 2012. Results: The average score of satisfaction in major, career decision-making self-efficacy and career identity of nursing students was 3.56 on a 5 point-scale, 3.28 on a 5 point-scale, and 2.65 on a 4 point-scale respectively. There were significant correlation between satisfaction in major, career decision-making self-efficacy and career identity of nursing students. Career identity could be explained 26.2% by satisfaction in major, career decision-making self-efficacy, admission motivation, and school grade. Conclusion: Career identity was correlated with satisfaction in major and career decision-making self-efficacy in nursing students. Therefore, it is necessary to develop an effective intervention program to improve nursing students's satisfaction in major, career decision-making self-efficacy and career identity.

간호사의 모유수유에 대한 지식정도와 모유수유간호활동 수행정도 (Nurse's Knowledge to Breast-Feeding and Nursing Activities related to Breast-Feeding)

  • 성미혜
    • 여성건강간호학회지
    • /
    • 제6권2호
    • /
    • pp.258-268
    • /
    • 2000
  • This study was to investigate the relationship between hospital nurses 'knowledge of breast-feeding and their ability to provide care to breast-feeding mothers and their children. From Nov. 1 to 30, 1999, 105 nurses of the obstetric ward, delivery room, OPDs of obstetrics and gynecology, and nurseries of three general hospitals from Seoul and Pusan were evaluated. The results are as follows: 1.Mean score of nurse's knowledge to breast-feeding was 12.76. Mean score of performance of nursing activities was 109.80. 2.General characteristics and feeding characteristics were significantly related to nurse's knowledge to breast-feeding and performance of nursing activities related to breast-feeding. Nurse's knowledge about breast-feeding was significantly related to age, working ward, clinical experience, rank of position, experience of breast-feeding and experience education on breast-feeding. Performance of nursing activities for breast- feeding was significantly related to age, working ward, experience in other ward, marital status, and education on breast-feeding. 3.A positive correlation between nurse's know-ledge to breast-feeding and performance of nursing activities related to breast-feeding was statistically significant(r=.381, P<0.05).

  • PDF

유기금속화학기상증착법으로 제조된 자성반도체 $Ti_{1-x}Co_xO_2$ 박막의 미세구조 및 자기적 특성 (Microstructure and Magnetic properties of $Ti_{1-x}Co_xO_2$ Magnetic semiconductor thin films by Metal Organic Chemical Vapor Deposition)

  • 성낙진;윤순길
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.1
    • /
    • pp.155-159
    • /
    • 2003
  • Polycrystalline $Ti_{1-x}Co_xO_2$ thin films on $SiO_2$ (200 nm)/Si (100) substrates were prepared using liquid-delivery metalorganic chemical vapor deposition. Microstructures and ferromagnetic properties were investigated as a function of doped Co concentration. Ferromagnetic behaviors of polycrystalline films were observed at room temperature, and the magnetic and structural properties strongly depended on the Co distribution, which varied widely with doped Co concentration. The annealed $Ti_{1-x}Co_xO_2$ thin films with $x{\leq}0.05$ showed a homogeneous structure without any clusters, and pure ferromagnetic properties of thin films are only attributed to the $Ti_{1-x}Co_xO_2$ (TCO) phases. On the other hand, in case of thin films above x=0.05, Co clusters formed in a homogeneous $Ti_{1-x}Co_xO_2$ Phase, and the overall ferromagnetic (FM) properties depended on both $FM_{TCO}$ and $FM_{Co}$. Co clusters with about 10nm-150nm size decreased the value of Mr (the remanent magnetization) and increased the saturation magnetic field.

  • PDF

의인성 쇄골하정맥 파열로 인한 응급 혈관내 스텐트 삽입 (Urgent Endovascular Stent Graft Placement for Iatrogenic Subclavian Artery Rupture)

  • 강병우;배준호;정진욱;조병주;박준기;나득영
    • Journal of Trauma and Injury
    • /
    • 제28권2호
    • /
    • pp.83-86
    • /
    • 2015
  • Central venous cannulation is one of the most commonly performed procedures for critically ill patients in the emergency room. Serious complications like a rupture of subclavian artery may occur during this procedure. We report a case of successful stent graft deployment for iatrogenic ruptured subclavian artery after attempted right subclavian vein catheterization in a 31 year-old female patient with hypovolemic shock due to cervical os laceration during vaginal delivery.

  • PDF

Feasible approach of contactless power transfer technology combined with HTS coils based on electromagnetic resonance coupling

  • Chung, Yoon Do;Yim, Seong Woo;Hwang, Si Dole
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제15권1호
    • /
    • pp.40-44
    • /
    • 2013
  • The contactless power transfer (CPT) systems have been recently gaining popularity widely since it is an available option to realize the power delivery and storage with connector-free devices across a large air gap. Especially, the CPT with electromagnetic resonance coupling method is possible to exchange energy within 2 m efficiently. However, the power transfer efficiency of CPT in commercialized products has been limited because the impedance matching of coupled coils is sensitive. As a reasonable approach, we combined the CPT system with HTS wire technology and called as, superconducting contactless power transfer (SUCPT) system. Since the superconducting coils have an enough current density, the superconducting antenna and receiver coils at CPT system have a merit to deliver and receive a mass amount of electric energy. In this paper, we present the feasibility of the SUCPT system and examine the transmission properties of SUCPT phenomenon between room temperature and very low temperature at 77 K as long as the receiver is within 1.0 m distance.

Optimization of Preparation Variables for Trimyristin Solid Lipid Nanoparticles

  • Choi, Mi-Hee;Lee, Mi-Kyung
    • Journal of Pharmaceutical Investigation
    • /
    • 제37권1호
    • /
    • pp.51-55
    • /
    • 2007
  • Solid lipid nanoparticles (SLNs) have been regarded to behave similar to the vegetable oil emulsions because emulsions of lipid melts are formed before lipid droplets being solidified to turn into SLNs. Compared to lipid emulsion, however, it has been more difficult to obtain stable SLNs and needs more extensive considerations on stabilizer and manufacturing process. In the present study, we tried to prepare phosphatidylcholine-based trymyristin (TM) SLNs using high pressure homogenization method and optimize the manufacturing variables such as homogenization pressure, number of homogenization cycles, cooling temperature, co-stabilizer and freeze-drying with cryoprotectants. Nano-sized TM particles could be Prepared using egg Phosphatidylcholine and pegylated phospholipids ($PEG_{2000}$PE) as stabilizers. Based on the optimization study, the dispersion was manufactured by homogenization under the pressure of 100 MPa for more than 5 cycles, and solidifying the intermediately formed lipid melt droplets by dipping in liquid nitrogen followed by thawing at room temperature. In addition, TM SLNs could be freeze-dried and then redispersed easily without significant particle size changes after freeze drying with 10% and 12.5% sucrose or trehalose. The TM SLNs established in this study can be used as delivery system for drugs and cosmetics.

Ketorolac Ester Enhancer-prodrugs: Preparation and Evaluation of Their Physicochemical Properties

  • Yun, Sung-Il;Kim, Jung-Sun;Yong, Chul-Soon
    • Journal of Pharmaceutical Investigation
    • /
    • 제38권6호
    • /
    • pp.405-412
    • /
    • 2008
  • Six ester analogues of Ketorolac were synthesized as potential enhancer prodrugs for transdermal delivery. Solubility of these esters was determined in 10% propylene glycol (PG)/isotonic phosphate buffer (IPB) at room temperature while lipophilicity was obtained as partition coefficients (log P) and capacity factors (k') using HPLC. Stability of the prodrugs in skin extract and in plasma was investigated at $37^{\circ}C$. The lipophilicity of the potential prodrugs increased in proportion to their alkyl chain length. Good linear relationship between partition coefficients (log P) and capacity factors (log k') was observed ($R^2=0.9961$). All of the analogues were fairly stable but slowly degraded in IPB over a 12 hour period. However, their stability in skin extract and in plasma varied with most compounds gradually decomposing over a 12 hour period. Although unsaturation of the alkyl ester chain did not alter the over all lipophilicity of the compound, the half-life was significantly affected. In plasma, degradation of the esters was slower than in the skin extract, which is a desirable trait for enhancer-prodrugs. However, the overall hydrolysis in the skin extract needs to be facilitated for the development of an effective enhancer prodrug. The analogue with the shortest half life in the skin extract was the unsaturated C-12 analogue of 0.96 hr.

Exploring the Feasibility of Differentiating IEEE 802.15.4 Networks to Support Health-Care Systems

  • Shin, Youn-Soon;Lee, Kang-Woo;Ahn, Jong-Suk
    • Journal of Communications and Networks
    • /
    • 제13권2호
    • /
    • pp.132-141
    • /
    • 2011
  • IEEE 802.15.4 networks are a feasible platform candidate for connecting all health-care-related equipment dispersed across a hospital room to collect critical time-sensitive data about patient health state, such as the heart rate and blood pressure. To meet the quality of service requirements of health-care systems, this paper proposes a multi-priority queue system that differentiates between various types of frames. The effect of the proposed system on the average delay and throughput is explored herein. By employing different contention window parameters, as in IEEE 802.11e, this multi-queue system prioritizes frames on the basis of priority classes. Performance under both saturated and unsaturated traffic conditions was evaluated using a novel analytical model that comprehensively integrates two legacy models for 802.15.4 and 802.11e. To improve the accuracy, our model also accommodates the transmission retries and deferment algorithms that significantly affect the performance of IEEE 802.15.4. The multi-queue scheme is predicted to separate the average delay and throughput of two different classes by up to 48.4% and 46%, respectively, without wasting bandwidth. These outcomes imply that the multi-queue system should be employed in health-care systems for prompt allocation of synchronous channels and faster delivery of urgent information. The simulation results validate these model's predictions with a maximum deviation of 7.6%.