• Title/Summary/Keyword: Delayed implantation

Search Result 49, Processing Time 0.028 seconds

Safety of a Totally Implantable Central Venous Port System with Percutaneous Subclavian Vein Access

  • Keum, Dong-Yoon;Kim, Jae-Bum;Chae, Min-Cheol
    • Journal of Chest Surgery
    • /
    • v.46 no.3
    • /
    • pp.202-207
    • /
    • 2013
  • Background: The role of totally implantable central venous port (TICVP) system is increasing. Implantation performed by radiologist with ultrasound-guided access of vein and fluoroscope-guided positioning of catheter is widely accepted nowadays. In this article, we summarized our experience of TICVP system by surgeon and present the success and complication rate of this surgical method. Materials and Methods: Between March 2009 and December 2010, 245 ports were implanted in 242 patients by surgeon. These procedures were performed with one small skin incision and subcutaneous puncture of subclavian vein. Patient's profiles, indications of port system, early and delayed complications, and implanted period were evaluated. Results: There were 82 men and 160 women with mean age of 55.74. Port system was implanted on right chest in 203, and left chest in 42 patients. There was no intraoperative complication. Early complications occurred in 11 patients (4.49%) including malposition of catheter tip in 6, malfunction of catheter in 3, and port site infection in 2. Late complication occurred in 12 patients (4.90%). Conclusion: Surgical insertion of TICVP system with percutaneous subclavian venous access is safe procedures with lower complications. Careful insertion of system and skilled management would decrease complication incidence.

Reproductive Biology of the Seals in Polar Region: Spermatogenesis (극지역 물개류의 번식생물학: 정자형성)

  • Gye Myung-Chan;Kang Sung-Ho
    • Korean Journal of Environmental Biology
    • /
    • v.24 no.1 s.61
    • /
    • pp.1-6
    • /
    • 2006
  • Abstract - Global decline in wildlife mammals has been accelerated during past decades. Especially the conservation the wild life mammals in polar areas, is urgent. In an effort to understand the reproduction of the seals dwelling in the polar area, spermatogenesis in the seals was reviewed. Seals breed seasonally and in most of the seal species, delayed implantation is frequently observed. To date, histological and endocrinological evaluation revealed highly cyclic nature in supermatogenesis and steroidogenesis in testis. Seasonal changes in blood testosterone level together with melatonin is closely related with changes in light cycle between summer and winter. In adult testis at breeding seasons, spermatogenesis is manifested by consecutive 18 stages of germ cell development. Three kinds of Leydig cells different in steroidogenic activity as well as cellular morphology appear during the testis development. During non-breeding season, spermatogenic arrest and Leydig cell hypoplasia are frequently found. Interestingly, blood circulation through the anastomoses of pelvic veins cooled the testes and thus guarantees spermatogenesis within the body trunk. Endocrine disruptors and heavy metals have been found in the body tissues of several seals species and alter steroidogenesis in seals, suggesting environmental pollutants together with decrease in habitats are potentially threatening the reproductive success in seal species.

On the Activity of Phosphatase in the Endometrium of the Rat Uterus During Early Pregnancy (초기 임신 기간중 흰쥐 자궁 내막조직의 Phosphatase 활성에 관하여)

  • Kim, Sung-Rye;Cho, Wan-Kyoo
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.8 no.2
    • /
    • pp.1-11
    • /
    • 1981
  • The quantitative analyses of the phosphatase activity in the endometrium of the rat ovariectomized on Day 2 of pregnancy was carried out in comparison with the intact one, in order to investigate the hormonal dependency of the uterus prior to the implantation, and to study the phosphatase activity in the endometrial tissues in vitro incubated in different acidity of the medium. The results obtained were as follows: 1. The activity of the total phosphatase was the highest at Day 3 of pregnancy of the intact animals irrespective of acidity of the medium. However, the ovariectomized rat showed its peak somewhat delayed. The time of the highest activity of the enzymes was matched with the time of high secretion of the ovarian hormones. 2. The activity of acid phosphatase in the endometrium was twice or four times as much high as that of neutral or alkaline phosphatase, respectively. 3. The activity of alkaline phosphatase was rather steady in Day 3 through Day 5 of the pregnancy of the rat intact or ovariectomized but with low level compared to those of other phosphatase. 4. The present re~lt indicated more important role by $Mg^{2+}$-dependent phosphatase than by $K^+$-dependent one for the preparation for decidualization.

  • PDF

Repeated failure of implants at the same site: a retrospective clinical study

  • Kang, Dong-Woo;Kim, So-Hyun;Choi, Yong-Hoon;Kim, Young-Kyun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.41
    • /
    • pp.27.1-27.9
    • /
    • 2019
  • Background: Implants are becoming the first choice of rehabilitation for tooth loss. Even though they have a high success rate, failures still occur for many reasons. The objective of this study is to analyze the reasons for recurring failure at the same site and the results of re-implantation. Methods: Thirteen patients (11 males and 2 females, mean age 60 ± 9.9 years) who experienced implant surgery failure at the same site (same tooth extraction area) two or more times in the Department of Oral and Maxillofacial Surgery, Seoul National University Bundang Hospital, between 2004 and 2017 were selected. The medical records on a type, sites, diameter, and length of implants; time and estimated cause of failure; and radiographs were reviewed. Data were collected and analyzed retrospectively, and the current statuses were evaluated. Results: A total of 14 implants experienced failure in the same site more than two times. Twelve implants were placed in the maxilla, while 2 implants were placed in the mandible. The maxillary molar area was the most common site of failure (57.1%), followed by the mandibular molar, anterior maxilla, and premolar areas (14.3% each). The first failure occurred most commonly after prosthetic treatment (35.7%) with an average period of failure of 3.8 months after loading. Ten cases were treated as immediate re-implantation, while the other 4 were delayed reimplantation after an average of 3.9 months. The second failure occurred most commonly after prosthetic treatment (42.9%), with an average of 31 months after loading; during the healing period (42.9%); and during the ongoing prosthetic period (14.3%). In 3 cases (21.4%), the treatment plan was altered to an implant bridge, while the other 11 cases underwent another implant placement procedure (78.6%). Finally, a total of 9 implants (64.3%) survived, with an average functioning period of 60 months. Conclusions: Implants can fail repeatedly at the same site due to overloading, infection, and other unspecified reasons. The age and sex of the patient and the location of implant placement seem to be associated with recurring failure. Type of implant, bone augmentation, and bone materials used are less relevant.

Influence of Hwanhonsan Extract against Chemically Induced and Xenografted Mice Tumor (환혼산(還魂散)이 실험적(實驗的)으로 유발(誘發)한 종양(腫瘍)에 미치는 영향(影響))

  • Song, Hyo-Won;Ryu, Do-Gon;Cho, Dong-Ki;Um, Sang-Sub;Kang, Sung-Do;Go, Jeoin-Soo;Sung, Yeun-Kyung;Yun, Young-Gap;Cho, Nam-Su;Lee, Chun-Woo;Kang, Soon-Soo
    • Journal of Oriental Physiology
    • /
    • v.14 no.2 s.20
    • /
    • pp.229-237
    • /
    • 1999
  • Hwanhonsan has been used for curing tumor as a Oriental medicine without any experimental evidence to support the rational basis for their clinical use. This experiment was carried out to evaluate the possible therapeutic or antitumoral effects of Hwanhonsan extract against cancer, and to study some mechanisms responsible for its effect. Some kind of tumors were induced by the typical application of 3-methylcholanthrene(MCA) or by the implantation of malignant tumor cells such as leukemia cells(3LL cells) or sarcoma cells(S180 cells) and FasII cells. Treatment of the Hwanhonsan extract(daily 1 mg/mouse, i.p.) was continued for 7 days prior to tumor induction and after that the treatment was lasted for 20 hrs. Against squamous cell carcinoma induced by MCA, Hwanhonsan decreased. not only the frequency of tumor production but also the number and weight of tumors per tumor bearing mice(TBM). Hwanhonsan also significantly suppressed the development of 3LL cells and S180 cells implanted tumors by frequency and their size, and some developed tumors were regressed by the continuous treatment of Hwanhonsan extract into TBM. However, when tumor was induced by FsaII cells implantation, the growth of implanted cells in mice was delayed by the water extract of Hwanhonsan until 7 days and then rapid growth ensued. In vitro treatment of Hwanhonsan extract had no inhibitory effect on the tumor induced by some kind of cell lines such as A431 cells strain but it significantly inhibited the proliferation of 3LL cells, S180 cells. These results suggested that Hwanhonsan extract exhibited a significant prophylactic benefits against tumors and its antitumor activity was manifested depending on the type of tumor cells.

  • PDF

The long-term evaluation of the prognosis of implants with acid-etched surfaces sandblasted with alumina: a retrospective clinical study

  • Kim, Min-Joong;Yun, Pil-Young;Chang, Na-Hee;Kim, Young-Kyun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.42
    • /
    • pp.10.1-10.9
    • /
    • 2020
  • Background: The aim of this study was to evaluate the long-term clinical stability of implants with acid-etched surfaces sandblasted with alumina using retrospective analyses of the survival rate, success rate, primary and secondary stability, complications, and marginal bone loss of the implants. Methods: Patients who had implants placed (TS III SA, SS II SA, SS III SA, and U III SA) with SA surfaces from Osstem (Osstem Implant Co., Busan, Korea) at the Seoul National University Bundang Hospital, from January 2008 to December 2010 were selected for the study. Patients' medical records and radiographs (panorama, periapical view) were retrospectively analyzed to investigate sex, age, location of implantation, diameter, and length of the implants, initial and secondary stability, presence of bone grafting, types of bone grafting and membranes, early and delayed complications, marginal bone loss, and implant survival rate. Results: Ninety-six implants were placed in 45 patients. Five implants were removed during the follow-up period for a total survival rate of 94.8%. There were 14 cases of complications, including 6 cases of early complications and 8 cases of delayed complications. All five implants that failed to survive were included in the early complications. The survival of implants was significantly associated with the occurrence of complications and the absorption of bone greater than 1 mm within 1 year after prosthetic completion. In addition, the absorption of bone greater than 1 mm within 1 year after prosthetic completion was significantly associated with the occurrence of complications, primary stability, and implant placement method. Five cases that failed to survive were all included in the early complications criteria such as infection, failure of initial osseointegration, and early exposure of the fixture. Conclusions: Of the 96 cases, 5 implants failed resulting in a 94.8% survival rate. The failed implants were all cases of early complications such as infection, failure of initial osseointegration, and early exposure of the fixtures. Periimplantitis was mostly addressed through conservative and/or surgical treatment and resulted in very low prosthetic complications. Therefore, if preventive measures are taken to minimize initial complications, the results can be very stable.

Inhibitory activities of polysaccharide purified from Phellodendron chinese SCHNEID on melanoma B-16-derived metastatic tumor and hypersensitivity

  • Kim, June-Ki;Kim, Sung-Soo;Jun, Kyun-Il;Lee, Dong-Young;Lee, Tae-Kyun;Song, Eun-Young;Kim, Cheorl-Ho
    • Advances in Traditional Medicine
    • /
    • v.1 no.2
    • /
    • pp.36-44
    • /
    • 2000
  • The polysaccharide fractions were isolated and purified from Phellodendron chinese SCHNEID, and antitumor activities using the melanoma B-16-derived metastatic tumors were examined at dosages of 2, 5 and 10 mg/100 g. F-7 and F-8 showed the highest tumor metastatic inhibitory activities (inhibition ratio 60 and 80% in 2 mg/100 g), and in dose of 5 mg/100 g, the inhibitory ratios were 85 and 70%, respectively. Furthermore, 10 mg/100 g of intraperitoneal (i.p.) injection gave 90 and 95% of inhibition. When the effects of polysaccharides on hypersensitivity were examined, the inhibitory activities were not markedly observed in oral administration, indicating that the polysaccharides are directly acting to immune system. Also, the polysaccharides increased the number of circulating blood leukocytes and total peritoneal exudate cells. Although implantation of tumor cells greatly decreased the productivity of antibody (antibody-mediated) and T lymphocyte reactivity (delayed-type) as 6.3 from 9.3 and 5.9 from 7.7, represented by the increase of footpad thickness, respectively. the polysaccharides elevated the reactivity of T lymphocyte in tumor-bearing mice, which were rapidly recovered by discontinuance of sample treatments. Especially, F-2, F-5, F-7 and F-8 remarkably recovered the decreased sensitivity. These results clearly indicated that the i.p. injection is much effective to suppress tumor growth than oral administration.

  • PDF

Postpneumonectomy Syndrome after Left Pneumonectomy -one case report- (좌측 전폐절제술후 발생한 Postpneumonectomy Syndrome의 치험 1례)

  • 윤용한;이두연;김부연
    • Journal of Chest Surgery
    • /
    • v.31 no.6
    • /
    • pp.624-628
    • /
    • 1998
  • Postpneumonectomy syndrome is a rare and delayed complication of left pneumonectomy in most patients with normal mediastinal vascular anatomy. This syndrome is characterized by dyspnea and recurrent pulmonary infection in the remaining right lung that typically occur within the first postoperative year. The condition is believed to be secondary to postsurgical changes that include a marked shift of the mediastinum to the left, clockwise rotation of the heart and great vessels, and herniation of the right lung into the left anterior thorax. These changes lead to compression of the trachea or right main bronchus among the thoracic spine and the right pulmonary artery. We report a case of postpneumonectomy syndrome in 15 year-old girl that followed by left pneumonectomy for bronchiectasis 6 years ago. We have inserted an expandable prosthesis in the left thoracic cavity posterior to the heart. After implantation of an expandable prosthesis, an anatomic reposition of the shifted mediastinum was achieved, which resulted in instantaneous and sustained relief. The post-operative course was uneventful and the patient was followed in OPD from after discharge to now.

  • PDF

Case series of maxillary sinus augmentation with biphasic calcium phosphate: a clinical and radiographic study

  • Cha, Jae-Kook;Park, Jung-Chul;Jung, Ui-Won;Kim, Chang-Sung;Cho, Kyoo-Sung;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.41 no.2
    • /
    • pp.98-104
    • /
    • 2011
  • Purpose: The aim of this study was to evaluate 3.5 years-cumulative survival rate of implants placed on augmentedsinus using Osteon, a bone graft material, and to assess the height of the grafted material through radiographic evaluation. Methods: Twenty patients were treated with maxillary sinus augmentation and 45 implant fixtures were installed simultaneously or after 6 months healing period. The height of the augmented sinus and the loss of marginal bone were measured by panoramic and intraoral radiographs immediately after augmentation and up to 42 months (mean, 19.4 months) subsequently. Changes in the height of the sinus graft material were calculated radiographically. Results: The cumulative survival rate was 95.56% in all 45 implants. Additionall, normal healing process without any complication was observed in all patients. The original sinus height was mean 4.3 mm and the augmented sinus height was mean 13.4 mm after the surgery. The mean marginal bone loss till 42 months was $0.52{\pm}0.56\;mm$. The reduced height of Osteon was $0.83{\pm}0.38\;mm$ and it did not show significant correlation with the follow up periods (P=0.102). There were no statistically significant differences in reduced height of Osteon according to the simultaneous/delayed implantation (P=0.299) and particle size of Osteon (P=0.644). Conclusions: It can be suggested that Osteon may have predictable result when it was used as a grafting material for sinus floor augmentation.

CLINICAL & RADIOGRAPHIC EVALUATION FOLLOWING DELAYED IMPLANTATION USING REGULAR DIAMETER IMPLANTS IN THE POSTERIOR REGION (구치부에 발치 후 지연 식립된 표준 직경의 임플란트에 대한 임상적, 방사선학적 평가)

  • Choi, Jung-Yong;Lee, Sang-Hwa;Yoon, Hyun-Joong
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.35 no.5
    • /
    • pp.335-339
    • /
    • 2009
  • The purpose of this study was to evaluate clinical and radiographic changes of regular diameter implants placed in the posterior region. A total of 47 standard diameter implants were consecutively placed in the posterior region of 20 partially edentulous patients. The diameters of the implants were 4.1mm (N=35, 74%) and 4.3mm (N=12, 26%), respectively. Peri-implant bone loss and clinical parameters such as mobility, suppuration, swelling, bleeding on probing (BOP) were evaluated at the baseline and?the final follow-up visit. The age of the patients ranged between 24~82 years (mean age: 54.7 years). The cumulative survival rate of the regular diameter implants loaded for a period of 3-24 months (Mean: $11.7{\pm}7.9$ month) was 100%. The average bone loss over the follow-up was $0.36{\pm}0.67\;mm$. Success rate was 95.7%. Only two implants failed (bone loss exceeding 1mm after 1 year of placement). Some prosthetic complications occurred, such as screw loosening (N=1) and dissolution of cementation material (N=2). The present study describes successful outcome following the use of standard-diameter-implants placed in the posterior region, and further comprehensive maintenance practices and follow-up schedules are required.