• Title/Summary/Keyword: Degradation Curve

Search Result 253, Processing Time 0.029 seconds

The characteristic of leakage current in ZnO surge arrestor elements with mixed direct and 60Hz voltage (중첩전압(직류+교류 60Hz)에서 산화아연 피뢰기 소자의 누설전류 특성)

  • Lee, B.H.;Pak, K.Y.;Kang, S.M.;Choi, H.S.;Oh, S.K.
    • Proceedings of the KIEE Conference
    • /
    • 2003.10a
    • /
    • pp.186-188
    • /
    • 2003
  • The ZnO surge arrester is the protective device for limiting surge voltages on equipment by diverting surge current and returning the device to its original status. The occurrence of overvoltage appears in any phase to AC power supply system and it appears in mixing AC and impulse voltages, moreover because HVDC power supply system uses converter in semiconductor, it makes mixed DC and high harmonics voltages. In this study, the various mixed AC and DC voltages was made for investigating the degradation effect of ZnO arrester according to mixed voltage. As a result, the increase of DC component to mixed voltages causes the increase of resistive component of total leakage current to ZnO block. In changing V-I curve for mixed voltages, the cross-over point acts a factor as making the proper capacitor size of an equivalent circuit for ZnO block.

  • PDF

Correlation between Ultrasonic Nonlinearity and Elastic Nonlinearity in Heat-Treated Aluminum Alloy

  • Kim, Jongbeom;Jhang, Kyung-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.37 no.2
    • /
    • pp.115-121
    • /
    • 2017
  • The nonlinear ultrasonic technique is a potential nondestructive method to evaluate material degradation, in which the ultrasonic nonlinearity parameter is usually measured. The ultrasonic nonlinearity parameter is defined by the elastic nonlinearity coefficients of the nonlinear Hooke's equation. Therefore, even though the ultrasonic nonlinearity parameter is not equal to the elastic nonlinearity parameter, they have a close relationship. However, there has been no experimental verification of the relationship between the ultrasonic and elastic nonlinearity parameters. In this study, the relationship is experimentally verified for a heat-treated aluminum alloy. Specimens of the aluminum alloy were heat-treated at $300^{\circ}C$ for different periods of time (0, 1, 2, 5, 10, 20, and 50 h). The relative ultrasonic nonlinearity parameter of each specimen was then measured, and the elastic nonlinearity parameter was determined by fitting the stress-strain curve obtained from a tensile test to the 5th-order-polynomial nonlinear Hooke's equation. The results showed that the variations in these parameters were in good agreement with each other.

Simultaneous Determination of Valproic Acid and its Toxic Metabolites, 4-ene-VPA and 2,4-diene-VPA in Rat Plasma using a Gas Chromatographic-mass Spectrometric Method

  • Lee, Min-Sun;Lee, Young-Joo;Chung, Bong-Chul;Jung, Byung-Hwa
    • Journal of Pharmaceutical Investigation
    • /
    • v.40 no.3
    • /
    • pp.155-160
    • /
    • 2010
  • A gas chromatographic-mass spectrometric (GC-MS) method was developed for the simultaneous determination of valproic acid (VPA) and its toxic metabolites, 4-ene-VPA and 2,4-diene-VPA in rat plasma. Extraction was performed in weak acidic condition (pH 5.2) to avoid degradation of 4-ene-VPA and 2,4-diene-VPA. The recoveries for 4-ene-VPA and 2,4-diene-VPA were more than 70% and that for VPA was 33-42%. R value for each compounds exceeded 0.998 in calibration curve during all the analysis. Accuracy and precision ranged from 88.3 to 113.2% and from 2.16 to 14.2%, respectively The method was successfully applied to monitor plasma concentrations of VPA, 4-ene-VPA and 2,4-diene-VPA after intravenous administration of VPA at the dose of 100 mg/kg, suggesting that these toxic metabolites may involved in the hepatotoxicity induced by VPA.

Optimal Image Quality Assessment based on Distortion Classification and Color Perception

  • Lee, Jee-Yong;Kim, Young-Jin
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.10 no.1
    • /
    • pp.257-271
    • /
    • 2016
  • The Structural SIMilarity (SSIM) index is one of the most widely-used methods for perceptual image quality assessment (IQA). It is based on the principle that the human visual system (HVS) is sensitive to the overall structure of an image. However, it has been reported that indices predicted by SSIM tend to be biased depending on the type of distortion, which increases the deviation from the main regression curve. Consequently, SSIM can result in serious performance degradation. In this study, we investigate the aforementioned phenomenon from a new perspective and review a constant that plays a big role within the SSIM metric but has been overlooked thus far. Through an experimental study on the influence of this constant in evaluating images with SSIM, we are able to propose a new solution that resolves this issue. In the proposed IQA method, we first design a system to classify different types of distortion, and then match an optimal constant to each type. In addition, we supplement the proposed method by adding color perception-based structural information. For a comprehensive assessment, we compare the proposed method with 15 existing IQA methods. The experimental results show that the proposed method is more consistent with the HVS than the other methods.

Predicting the bond between concrete and reinforcing steel at elevated temperatures

  • Aslani, Farhad;Samali, Bijan
    • Structural Engineering and Mechanics
    • /
    • v.48 no.5
    • /
    • pp.643-660
    • /
    • 2013
  • Reinforced concrete structures are vulnerable to high temperature conditions such as those during a fire. At elevated temperatures, the mechanical properties of concrete and reinforcing steel as well as the bond between steel rebar and concrete may significantly deteriorate. The changes in the bonding behavior may influence the flexibility or the moment capacity of the reinforced concrete structures. The bond strength degradation is required for structural design of fire safety and structural repair after fire. However, the investigation of bonding between rebar and concrete at elevated temperatures is quite difficult in practice. In this study, bond constitutive relationships are developed for normal and high-strength concrete (NSC and HSC) subjected to fire, with the intention of providing efficient modeling and to specify the fire-performance criteria for concrete structures exposed to fire. They are developed for the following purposes at high temperatures: normal and high compressive strength with different type of aggregates, bond strength with different types of embedment length and cooling regimes, bond strength versus to compressive strength with different types of embedment length, and bond stress-slip curve. The proposed relationships at elevated temperature are compared with experimental results.

Seismic demand estimation of RC frame buildings based on simplified and nonlinear dynamic analyses

  • Borzi, B.;Vona, M.;Masi, A.;Pinho, R.;Pola, D.
    • Earthquakes and Structures
    • /
    • v.4 no.2
    • /
    • pp.157-179
    • /
    • 2013
  • Vulnerability studies on the existing building stock require that a large number of buildings is analyzed to obtain statistically significant evaluations of the seismic performance. Therefore, analytical evaluation methods need to be based on simplified methodologies of analysis which can afford the treatment of a large building population with a reasonable computational effort. Simplified Pushover-Based Earthquake Loss Assessment approach (SP-BELA), where a simplified methodology to identify the structural capacity of the building through the definition of a pushover curve is adopted, was developed on these bases. Main objective of the research work presented in this paper is to validate the simplified methodology implemented in SP-BELA against the results of more sophisticated nonlinear dynamic analyses (NLDAs). The comparison is performed for RC buildings designed only to vertical loads, representative of the "as built" in Italy and in Mediterranean countries with a building stock very similar to the Italian one. In NLDAs the non linear and degrading behaviour, typical of the structures under consideration when subjected to high seismic loads, is evaluated using models able to capture, with adequate accuracy, the non linear behaviour of RC structural elements taking into account stiffness degradation, strength deterioration, and pinching effect. Results show when simplified analyses are in good agreement with NLDAs. As a consequence, unsatisfactory results from simplified analysis are pointed out to address their current applicability limits.

Generation and Protection of Efficient Watermark Signals and Image Quality Preservation in Transmission Channel Using Turbo Coding (효과적인 워터마크 신호의 생성과 보호 및 터보코딩을 이용한 전송채널상에서의 화질 보존)

  • Cho, Dong-Uk;Bae, Young-Lae
    • The KIPS Transactions:PartB
    • /
    • v.9B no.1
    • /
    • pp.91-98
    • /
    • 2002
  • In this paper, an implementation method of the efficient image transmission stage using watermarking and channel ceding is proposed. Usually, image communication system consists of both a transmitter part and a receiver part. The transmitter part takes charge of copyright protection of the generated image data, and image coding and compression that can deal with channel noises when transmitting. In the transmitter part, we propose a channel coding method which protects both the watermark signal and the original signal for protecting the copyright of image data and solving channel noises when transmitting. Firstly, copyright protection of image data is conducted. For this, image structure analysis is performed, and both the improvement of image quality and the generation of the watermark signal are made. Then, the histogram is constructed and the watermark signals are selected from this. At this stage, by embedding of the coefficients of curve fittness into the lower 4 bits of the image data pixels, image quality degradation due to the embedding of watermark signals are prevented. Finally, turbo coding, which has the most efficient error correction capability in error correction codes, has been conducted to protect signals of watermark and preserved original image quality against noises on the transmission channel. Particularly, a new interleaving method named "semi random inter]easer" has been proposed.

Molybdenum and Cobalt Silicide Field Emitter Arrays

  • Lee, Jong-Duk;Shim, Byung-Chang;Park, Byung-Gook;Kwon, Sang-Jik
    • Journal of Information Display
    • /
    • v.1 no.1
    • /
    • pp.63-69
    • /
    • 2000
  • In order to improve both the level and the stability of electron emission, Mo and Co silicides were formed from Mo mono-layer and Ti/Co bi-layers on single crystal silicon field emitter arrays (FEAs), respectively. Using the slope of Fowler-Nordheim curve and tip radius measured from scanning electron microscopy (SEM), the effective work function of Mo and Co silicide FEAs were calculated to be 3.13 eV and 2.56 eV, respectively. Compared with silicon field emitters, Mo and Co silicide exhibited 10 and 34 times higher maximum emission current, 10 V and 46 V higher device failure voltage, and 6.1 and 4.8 times lower current fluctuation, respectively. Moreover, the emission currents of the silicide FEAs depending on vacuum level were almost the same in the range of $10^{-9}{\sim}10^{-6}$ torr. This result shows that silicide is robust in terms of anode current degradation due to the absorption of air molecules.

  • PDF

A Study on Punchthrough and Hot-carrier Effects as LDD Process Parameters (LDD 공정 조건에 따른 편치쓰루 및 핫 캐리어 효과에 관한 연구)

  • An, Tae-Hyun;Kim, Nam-Hoon;Kim, Chang-Il;Seo, Yong-Jin;Chang, Eui-Goo
    • Proceedings of the KIEE Conference
    • /
    • 1998.07d
    • /
    • pp.1367-1369
    • /
    • 1998
  • To achieve the ULSI goals of higher density, greater performance and operation speed have been scaled down. However, the reduction of channel length cause undesirable problems such as drop of punchthrough voltage, hot-carrier degradation and high leakage current, etc.. It is shown that the device characteristics depend on process parameters. In this Paper, we catched hold of trends of hot-carrier effects and punchthrough voltages due to variation of some process parameters such as LDD doses(P), spacer lengths, channel doses($BF_2$) and $V_T$ adjusting channel implantation energies using design trend curve (DTC). As the LDD and channel doses increased, hot-carrier phenomena became more severe, and punchthrough voltage was decreased. It were represented that punchthrough and hot carrier effects were critically depend on LDD and channel doses.

  • PDF

Post-earthquake assessment of buildings using displacement and acceleration response

  • Hsu, Ting-Yu;Pham, Quang-Vinh
    • Earthquakes and Structures
    • /
    • v.17 no.6
    • /
    • pp.599-609
    • /
    • 2019
  • After an earthquake, a quick seismic assessment of a structure can facilitate the recovery of operations, and consequently, improve structural resilience. Especially for facilities that play a key role in rescue or refuge efforts (e.g., hospitals and power facilities), or even economically important facilities (e.g., high-tech factories and financial centers), immediately resuming operations after disruptions resulting from an earthquake is critical. Therefore, this study proposes a prompt post-earthquake seismic evaluation method that uses displacement and acceleration measurements taken from real structural responses that resulted during an earthquake. With a prepared pre-earthquake capacity curve of a structure, the residual seismic capacity can be estimated using the residual roof drift ratio and stiffness. The proposed method was verified using a 6-story steel frame structure on a shaking table. The structure was damaged during a moderate earthquake, after which it collapsed completely during a severe earthquake. According to the experimental results, a reasonable estimation of the residual seismic capacity of structures can be performed using the proposed post-earthquake seismic evaluation method.