• Title/Summary/Keyword: Defrosting

Search Result 86, Processing Time 0.032 seconds

NUMERICAL ANALYSIS OF THERMAL FLOW OF CABIN INTERIOR AND DE-ICING ON AUTOMOBILE GLASS (자동차 내부 열유동해석 및 전방유리면의 해빙 전산해석)

  • Song D. W.;Park W. G.;Jang K. L.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.75-80
    • /
    • 2005
  • The present work was undertaken to numerically analyze the defrosting phenomena of windshield glass. In order to analysis the phase change from frost to water on windshield glass by discharging hot air from a defroster nozzle, the flow and the temperature field of the cabin interior, the heat transfer through the windshield glass, and the phase change of frost should be solve simultaneously. In the present work, the flow field was obtained by solving 3-D incompressible Navier-Stokes equations, and the temperature field was computed from the incompressible energy equation. The phase change process was solved by the enthalpy method. For the code validation, the temperature and the phase change of the driven cavity were calculated. The calculation showed a good agreement with other numerical results. Then, the present code was applied to the defrosting problem of a real automobile, and a good agreement with the experimental data was also obtained.

  • PDF

The Effects of Various Defrosting Methods on the Amount of the Amino Acids in the Frozen Alaska Pollack (냉동방법에 따른 냉동태의 조성아미노산 함량의 변화에 관한 연구)

  • 안명수
    • Journal of the Korean Home Economics Association
    • /
    • v.17 no.4
    • /
    • pp.29-34
    • /
    • 1979
  • Three different defrosting methods were employed in order to investigated the change in the amount of the total proteins and the amino acids in the frozen Alaska Pollack. The sample were defrosted (1) in the air of 25$\pm$3$^{\circ}C$ (2) in the air at the temperature of 4 $\pm$ $1^{\circ}C$(3) in the flowing water of 22$\pm$ $3^{\circ}C$ respectively. The samples were quick-freezed at $-23^{\circ}C$ and stored for 1 month, 2 months, and 3 months keeping the temperature at $-15^{\circ}C$.

  • PDF

The Development of the Korean Motor Vehicle Safety Standards for Windscreen Wiper Systems of Motorcycles (이륜자동차 창닦이기장치 등의 국내안전기준 개발)

  • Han, Kyeonghee
    • Journal of Auto-vehicle Safety Association
    • /
    • v.9 no.3
    • /
    • pp.39-45
    • /
    • 2017
  • Two-wheeled motorcycles rarely use windscreen wipers in general. However, if two or more wheeled motorcycles with upper body employ windscreen wiper systems, clear visibility should be ensured regardless of weather conditions. The windscreen wiper systems include washers, defrosting, and demisting. As demands for the personal mobility are rapidly increased, the related global safety standards for motorcycles with upper body have been revised accordingly. Currently only EU regulations issue the provisions of windscreen wiper systems for L-category vehicles, which characterize two or more wheeled motorcycles. Therefore, in order to agree with international safety standards, it is necessary to revise KMVSS (Korea Motor Vehicle Safety Standards) for motorcycles. Here, KMVSS regarding windscreen wiper systems for motorcycles are studied considering the EU regulations. It is expected that the findings in this study are useful for future amendment of KMVSS.

Modeling of the Safety Distance between Defrost Heater and Plastic Inner Wall of Refrigerator (제상 히터와 냉장고 플라스틱 내벽 사이의 안전거리에 대한 모델링)

  • Jung, Young;Shin, Jong-Min;Tikhonov, Alexei V.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.3
    • /
    • pp.196-202
    • /
    • 2003
  • Two dimensional modeling was carried out to find the safety distance between the defrost heater and the plastic inner wall of domestic refrigerator Estimation was processed for the three cases; the estimation of plastic wall temperature (1) without any protection, (2) with an aluminum foil attached on a wall, and (3) with an aluminum shield installed between heater and wall. The former two cases are found to be dangerous during defrosting process, because the temperatures of inner wall reach above 80'C , which is the upper temperature limit of the wall material. The case with an aluminum shield is considered to be safe by maintaining the temperature of the wall in the range of 6$0^{\circ}C$ during defrosting process.

Numerical Study of Defrost Phenomenon of Automobile Windshield (자동차 전방 유리면 성에 전산 해빙해석)

  • 박만성;황지은;박원규;장기룡
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.2
    • /
    • pp.157-163
    • /
    • 2003
  • This work was undertaken for the numerical analysis of defrosting phenomena of automobile windshield. To analyze the defrost, the flow and temperature field of cabin interior, heat transfer through the windshield glass, and phase change of the frost should be analyzed simultaneously. The flow field was obtained by solving the 3-D unsteady Navier-Stokes equation and the temperature field was computed by energy equation. The phase-change process of Stefan problem was solved by enthalpy method. For code validation, the temperature field of the driven cavity was calculated. The result of calculation shows a good agreement with the other numerical results. Then, the present code was applied to the defrosting analysis of a real automobile and, also, a good agreement with experiment was obtained.

The Frost and Defrost Performances of Fin-and-Tube Exchangers with Different Surface Characteristics (표면특성이 다른 두 핀-관 열교환기의 착상 및 제상 성능)

  • 신종민;최봉준
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.6
    • /
    • pp.525-531
    • /
    • 2002
  • The effects of different surface hydrophilicity on frosting and defrosting characteristic were experimentally investigated. Mass of frost and water hold-up was measured. Results showed that no significant difference in the frost mass was found between the two different surfaces while the water hold-up of heat exchanger court be reduced by the enhancement of surface hydrophilicity. Also, the defrosting efficiency m hydrophilic surface was improved by 76%. It was expected that hydrophilic heat exchanger could provide the improvements in both thermal-hydraulic performances and system reliability during frost/defrost operating in refrigeration systems.

Experimental Study of a High Efficiency Transport Refrigeration Container under Cooling and Defrosting Conditions (고효율 냉동 컨테이너의 냉각 및 제상 실험)

  • Mun, Je-Cheol;Ardiyansyah, Ardiyansyah;Choi, Kwang-Il;Oh, Jong-Taek
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.277-281
    • /
    • 2008
  • This paper presents the development of a high efficiency transport refrigeration system for sliced-raw fish transportation. The refrigeration system is equipped with heat storage for reverse cycle-hot gas defrost (the stored heat is used during defrost cycle of the system). System performance and container operating conditions are analyzed during experimental investigation on a $3,225{\times}1,740{\times}1,640\;mm$ full-scale refrigerated container under cooling and defrosting conditions. The prototype system indicates better performance in terms of shorter cooling-down time, shorter defrost time and smaller fluctuations of refrigerated container's temperature.

  • PDF

Numerical Study on the Behavior of Snow Melting for the Analysis of Defrosting Procedure (제상과정 해석을 위한 눈의 융해거동에 관한 수치적 연구)

  • 이관수;박준상;김서영
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.6
    • /
    • pp.599-608
    • /
    • 2000
  • One dimensional numerical modeling was carried out for the melting behavior of dry snow and the unsaturated flow when heat was supplied from the bottom surface. Discrepancy between the previous experimental data and the present numerical results is substantially reduced by considering the density change of water permeation layer due to the infiltration of meltwater. In the parametric study for effective thermal conductivity, it was found that the effect of this parameter to the behavior of snow melting is minor. Sensitivity analysis showed that the melting time is most sensitive to changes in supplied heat flux, snow temperature, and bulk density, whereas snow bulk density and residual saturation have a significant effect on the height of water permeation layer in snow.

  • PDF

Feasibility Study on the Frost Prevention and Delay by the Method of Alternating the function of Outdoor Coil Rows (실외기 기능 교번을 통한 착상 방지 및 지연에 대한 실증 연구)

  • Jeon, Chang Duk
    • Journal of Institute of Convergence Technology
    • /
    • v.1 no.1
    • /
    • pp.1-4
    • /
    • 2011
  • The object of this experimental study is to investigate the effect on frost prevention and delay by the method of alternating the function of outdoor coil rows under the frost conditions ($2^{\circ}C/1^{\circ}C$). The heat pump system with the new method can make frost delay time longer and eliminate frost effectively. It is withstand over 280 minutes without a conventional defrosting method. Maximum COP in case of adopting new method is 13% higher than that in case of reverse cycle defrosting method. Also in case of moving air injection duct faster, the frost delay time is lengthened and its COP is enhanced more.

  • PDF