• Title/Summary/Keyword: Defect ratio

Search Result 468, Processing Time 0.033 seconds

Significance of the Preoperative Examinations in Predicting the Defect Size of Ventricular Septal Defect (심실중격결손의 크기 측정에 있어서 술전 검사의 의의)

  • Kim, Keun;Chang, Bong-Hyun;Lee, Jong-Tae;Kim, Kyu-Tae;Lee, Sang-Bum
    • Journal of Chest Surgery
    • /
    • v.25 no.3
    • /
    • pp.289-295
    • /
    • 1992
  • We evaluated the correlationship between the predicted defect size at preoperative examination and the actual defect size at operation room, by examining 69 cases of ventricular septal defect operated at the deparment of Thoracic and Cardiovascular surgery, Kyungpook University Hospital from January 1988 to December 1990. We excluded cases associated with other cardiac anomalies. Of the 69 cases, 39 are male and 30 female, forming 1.3:1 sex ratio in males favor. Their age range from 6 months to 16 year, and 4.3 on the average Their body weights are from 6 to 45kg and 15 on the average. According to Soto`s classification, perimembranous type costitutes 42 cases[61%], doubly committed subarterial type 23 cases[33%], and muscular type 4 cases[6%]. The average diameter of defect size is 8.0$\pm$3.5mm measured in 2D-echocardiogram, 5.6$\pm$3.4mm in angiogram, and 7.4$\pm$4.4mm in operative field. There is statistically significant correlation between the size from 2D-echocardiogram and actual defect size[p=0.001], and no significant difference between the two. Especially in the cases without anurysmal formation, they are nearly the same. Cardiothoracic ratio, pulmonary to systemic flow ratio, pressure ratio and resistance ratio also have statistically significant correlation. Main pumonary artery to descending aorta diameter ratio is correlated with the actual defect size. There is statistically significant correlation between the size from angiogram and actual defect size with some difference.

  • PDF

Development of surface defect inspection algorithms for cold mill strip using tree structure (트리 구조를 이용한 냉연 표면흠 검사 알고리듬 개발에 관한 연구)

  • Kim, Kyung-Min;Jung, Woo-Yong;Lee, Byung-Jin;Ryu, Gyung;Park, Gui-Tae
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.365-370
    • /
    • 1997
  • In this paper we suggest a development of surface defect inspection algorithms for cold mill strip using tree structure. The defects which exist in a surface of cold mill strip have a scattering or singular distribution. This paper consists of preprocessing, feature extraction and defect classification. By preprocessing, the binarized defect image is achieved. In this procedure, Top-hit transform, adaptive thresholding, thinning and noise rejection are used. Especially, Top-hit transform using local min/max operation diminishes the effect of bad lighting. In feature extraction, geometric, moment, co-occurrence matrix, histogram-ratio features are calculated. The histogram-ratio feature is taken from the gray-level image. For the defect classification, we suggest a tree structure of which nodes are multilayer neural network clasifiers. The proposed algorithm reduced error rate comparing to one stage structure.

  • PDF

Modification of acceleration signal to improve classification performance of valve defects in a linear compressor

  • Kim, Yeon-Woo;Jeong, Wei-Bong
    • Smart Structures and Systems
    • /
    • v.23 no.1
    • /
    • pp.71-79
    • /
    • 2019
  • In general, it may be advantageous to measure the pressure pulsation near a valve to detect a valve defect in a linear compressor. However, the acceleration signals are more advantageous for rapid classification in a mass-production line. This paper deals with the performance improvement of fault classification using only the compressor-shell acceleration signal based on the relation between the refrigerant pressure pulsation and the shell acceleration of the compressor. A transfer function was estimated experimentally to take into account the signal noise ratio between the pressure pulsation of the refrigerant in the suction pipe and the shell acceleration. The shell acceleration signal of the compressor was modified using this transfer function to improve the defect classification performance. The defect classification of the modified signal was evaluated in the acceleration signal in the frequency domain using Fisher's discriminant ratio (FDR). The defect classification method was validated by experimental data. By using the method presented, the classification of valve defects can be performed rapidly and efficiently during mass production.

A Study on the Implementation of LCD Defect Inspection Algorithm (LCD 결함검사 알고리즘에 관한 연구)

  • 전유혁;김규태;김은수
    • Proceedings of the IEEK Conference
    • /
    • 1999.11a
    • /
    • pp.637-640
    • /
    • 1999
  • In this Paper we show the LCD simulator for defect inspection using image processing algorithm and neural network. The defect inspection algorithm of the LCD consists of preprocessing, feature extraction and defect classification. Preprocess removes noise from LCD image, using morphology operator and neural network is used for the defect classification. Sample images with scratch, pinhole, and spot from real LCD color filter image are used. The proposed algorithms show that defect detected and classified in the ratio of 92.3% and 94.6 respectively.

  • PDF

Study on the Fabrication of a Large Steel Ingot with the Ultra Clean and Low Hot Top Ratio (저압탕 고청정 대형 잉고트 제조 연구)

  • Oh, S.H.;Lee, D.H.;Kim, N.S.;NamKung, J.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2009.05a
    • /
    • pp.91-93
    • /
    • 2009
  • A large steel ingot needs to be larger and larger in size and an ultra high clean, no defect in quality with a low hot top ratio for the resent heavy industry. The demands are very difficult to achieve simultaneously because of their contradictive effect to each other in results. In this study, 30ton steel ingot was cast in a foundry with an optimized design parameter of cast mold and cast process conditions for the low hot top ratio, 12%. The cast ingot was analyzed in macro defect, segregations, and cleanness. No macro defect was founded in central surface of the ingot. The degree of segregation and cleanness are in the controlled range with a sound quality.

  • PDF

A Study on the Correlation Analysis of Construction Period and Defect Repair Costs of Apartment Housing (공동주택 공사기간 및 하자보수비용의 상관관계 분석 연구)

  • Lee, Young-Jae;Cho, Dong-Hyun;Lee, Mi-Young;Park, Sang-Hun;Koo, Kyo-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.48-49
    • /
    • 2019
  • The number of disputes over defects after completion of construction work in apartment buildings is increasing every year. In this situation, the prediction of reasonable defect repair costs is very important. In this paper, we are going to collect basic data for predicting defect repair costs through the correlation analysis of the construction period and defect repair cost of apartment houses. For this purpose, first of all, the construction period and defect repair cost of apartment houses were analyzed to analyze the construction period for each type of work, the construction period for each project type, and the construction period for each standard calculation. Next, the correlation between defect repair cost and the independent variables of the candidate was conducted. According to the analysis, the ratio of framing air, the ratio of finishing air, and the number of delay days showed strong correlation.

  • PDF

Defect Severity-based Defect Prediction Model using CL

  • Lee, Na-Young;Kwon, Ki-Tae
    • Journal of the Korea Society of Computer and Information
    • /
    • v.23 no.9
    • /
    • pp.81-86
    • /
    • 2018
  • Software defect severity is very important in projects with limited historical data or new projects. But general software defect prediction is very difficult to collect the label information of the training set and cross-project defect prediction must have a lot of data. In this paper, an unclassified data set with defect severity is clustered according to the distribution ratio. And defect severity-based prediction model is proposed by way of labeling. Proposed model is applied CLAMI in JM1, PC4 with the least ambiguity of defect severity-based NASA dataset. And it is evaluated the value of ACC compared to original data. In this study experiment result, proposed model is improved JM1 0.15 (15%), PC4 0.12(12%) than existing defect severity-based prediction models.

Clinical Evaluation of 70 Cases of Ventricular Septal Defect in Korea (심실 중격결손증에 대한 임상적 고찰 [70예])

  • 조규석
    • Journal of Chest Surgery
    • /
    • v.11 no.1
    • /
    • pp.46-57
    • /
    • 1978
  • Ventricular septal defect was the most common congenital Heart disease admitted to the Severance Hospital from December, 1963 to June 30. 1977. A total of 1,811 cardiac patients received cardiac catheterization in the CardiacCenter of Yonsei University Medical College. Out of the 1,811 cardiac patients, 791 cases had congenital heart disease and of these 172 cases had ventricular septal defect. This amounted to 21.7% of all those with congenital heart disease. Seventy cases of ventricular septal defect operated on in the chest surgery department are presented. Of these 70 cases of ventricular septal defect, 54 cases were male and 16 cases were female. Their ages ranged from 4/12 months to 32 years. The ratio of systolic pressure of the main pulmonary to systemic artery [Pp/Ps] for 29 of the 59 isolated ventricular septal defects was below 45 percent. Pp/Ps ratio for 19 of the 59 isolated ventricular septal defects was 75 percent. The patients were mostly below fifteen years of age. Out of 64 cases, there were 36 cases of type II defects, 20 cases of type I, 4 cases of type III , 2 cases of type IV, one case of both type II and one case of left ventricular right atrial communication. The anomalies associated with ventricular septal defect were 13 in all; 4 cases of aortic insufficiency, 3 cases of ruptured aneurysm of the sortie sinus of valsalva, 2 cases of ruptured aneurysm of the sortie sinus of valsalva with aortic insufficiency, 2 cases of patent ductus arteriosus, one case of ruptured aneurysm of the aortic sinus of valsalva with atrial septal defect [secundum type] and one case of atrial septal defect [secundum type]. Overall mortality was 8.6 percent. The mortality in pulmonary artery banding was 37.5 percent. The causes of mortality were in one case congestive heart failure, in one case asphyxia and in one case respiratory insufficiency. Tile mortality in ventricular septal defect associated with pulmonary hypertension was 7.1 percent. The cause of mortality was in one case low cardiac output syndrome. There was no mortality in the ventricular septal defects without pulmonary hypertension and mortality in the ventricular septal defect. In ventricular septal defect associated with combined anomalies, the causes mortality were in one case respiratory insufficiency and in one case congestive heart failure.

  • PDF

Acoustic variations associated with congenital heart disease (선천성 심장병 환아에서 음향학적 요소의 변동)

  • Oh, Jung Eun;Choi, Yoon Mi;Kim, Sun Jun;Joo, Chan Uhng
    • Clinical and Experimental Pediatrics
    • /
    • v.53 no.2
    • /
    • pp.190-194
    • /
    • 2010
  • Purpose : To investigate the nature of deviant voice physiology in preoperative children with congenital heart disease. Methods : Ninety-four children with congenital heart disease were enrolled. Their cries and related acoustic variables (fundamental frequency, duration, noise to harmonic ratio, jitter and shimmer) were analyzed using a multi-dimensional voice program. Results : The average fundamental frequency showed a significant decrease in patent ductus arteriosus, ventricular septal defect, and tetralogy of Fallot, except in atrial septal defect and pulmonary stenosis. The length of the analyzed sample (duration) did not show a significant difference when compared with the control group. There was a significant increase in jitter percent in ventricular septal defect, patent ductus arteriosus, and atrial septal defect. There was an increase in shimmer in ventricular septal defect, patent ductus arteriosus, and atrial septal defect. The noise-to-harmonic ratio increased in ventricular septal defect, patent ductus arteriosus, and atrial septal defect but there was no significant difference in pulmonary stenosis and tetralogy of Fallot. While analyzing acoustic variables, the voice change was significantly higher, especially in patent ductus arteriosus followed by ventricular septal defect and atrial septal defect. Most of these acoustic variables were deviant in left-to-right shunt lesions in congenital heart disease, especially in patent ductus artriosus. Conclusion : The results of the voice change analysis of preoperative children with congenital heart disease revealed that the acoustic variables differed by each congenital heart disease. Moreover, the acoustic variables were prominently deviant in congenital heart disease with left-to-right shunts.

Behavior of Initiation and Propagation of Fatigue Cracks around Microholes (미소원공주위의 피로크랙발생전파 거동에 관한 연구)

  • 송삼홍;오환석
    • Journal of Ocean Engineering and Technology
    • /
    • v.1 no.2
    • /
    • pp.74-82
    • /
    • 1987
  • This study has been made to investigate into the behavior of fatigue limit, of fatigue crack initiation, and of fatigue crack propagation under the condition of rotating bending stress; specifically on the independency of stress field as well as the crack behavior of surface micro hole defect, which is made artificially through the specimen. The results obtained can be summarized as followa; 1) For the single micro hole defect, initiation of fatigue crack is occurred at both tips of microhole defect simultaneosly along the slip which are produced in the range of maximum principal stress arround micro hole defect independent of the size of micro hole defect. 2) For the neighbored deuble micro hole defects with equal size, in the range ($\frac{L}{r}$)ratio $\gtrsim$ 3 defined as the size of micro hole defect(2r) to the distance between the centers of micro hole defects (2L), the crack behavior of the micro hole defects is same as single one. However, for the range of $\frac{L}{r}$<3, the interference effect becomes significant as the ratio approaches to 1.

  • PDF