• Title/Summary/Keyword: Defect area

Search Result 838, Processing Time 0.023 seconds

A Novel OLED Inspection Process Method with Simultaneous Measurement for Standard and Deposition Pattern (기준패턴과 증착패턴의 동시 측정을 통한 OLED 공정 검사 방법)

  • Kwak, Byeongho;Cheoi, Kyungjoo
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.15 no.4
    • /
    • pp.63-70
    • /
    • 2019
  • The subject of the simultaneous measuring system of base pattern and deposition pattern is a new research topic on a defect inspection of OLED. In this paper, we propose a new OLED inspection method that simultaneously measures standard and deposition pattern images. This method reduces unnecessary processes and tac time during OLED inspection. For an additional reduction of the tac time during pattern measurement, the ROI was configured to measure only in the designated ROI area instead of measuring the entire area of an image. During the ROI set-up, the value of effective deposition pattern area is included so that if the deposition pattern is out of the ROI zone, it would be treated as a defect before measuring the size and center point of the pattern. As a result, the tac time and inspection process could be shortened. The proposed method also could be applied to the OLED manufacturing process. Production of OLED could be increased by reducing tac time and inspection process.

Paracrine effect of the bone morphogeneticprotein-2 at the experimental site on healing of the adjacent control site: a study in the rabbit calvarial defect model

  • Lee, Jin-Wook;Lim, Hyun-Chang;Lee, Eun-Ung;Park, Jin-Young;Lee, Jung-Seok;Lee, Dong-Woon;Jung, Ui-Won;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.44 no.4
    • /
    • pp.178-183
    • /
    • 2014
  • Purpose: The aim of this study was to assess the possible paracrine effect of bone morphogeneticprotein-2 (BMP-2) at the experimental site on the adjacent control site for validating a rabbit calvarial defect model as a means of verifying the effect of BMP-2. Methods: Sixteen rabbits were divided into two groups (n=8 in each) according to whether or not BMP-2 would be used. Two circular defects (8 mm in diameter) were created side by side, 2 mm apart, in the calvarium of all of the rabbits. In each animal, one of the defects was grafted with either BMP-2-loaded carrier or carrier material alone. The control defects adjacent to these grafted defects, designated CB (the nongrafted defect adjacent BMP-2-loaded carrier-grafted defect) and CC (the nongrafted defect adjacent to carrier only-grafted defect), respectively, were the focus of this study, and were filled only with a blood clot in all of the animals. Histologic observation and histomorphometric analysis were performed at 2 and 8 weeks (n=4 animals per point in time) after surgery. Results: There was no noteworthy difference in the healing pattern, and no statistically significant differences in histomorphometric parameters such as the defect closure, new bone area, or total augmented area between the CC and CB groups. Conclusions: The results of this study suggest that rabbit calvarial defects separated by a distance of 2 mm are suitable for evaluating the effects of BMP-2 and the control defect can be regarded not to be affected by BMP-2 applied defect.

The study of GaN-based semiconductors with low-defect density by microstructural characterization (미세구조 분석을 이용한 저밀도 결함을 가진 GaN계 반도체 연구)

  • Cho, Hyung-Koun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.424-427
    • /
    • 2003
  • We have investigated the microstructural analysis of epitaxial lateral overgrowth (ELO), pendeoepitaxy (PE), and superlattice structures used as technology for the reduction of structural defects like dislocation in nitride semiconductors using transmission electron microscopy. We confirmed that the regrowth process such as ELO and PE is very effective technique on the reduction of threading dislocation (less than $10^6/cm^2$) in the specific area. However, to decrease the defect density in the whole nitride films and the suppress the generation of defect by regrowth, we should find the optimized conditions. Besides, the process using double PE and AlGaN/GaN superlattice structure showed no effect on the defect reduction up to now.

  • PDF

An Analysis on the status of Measurement Investment in Korean Industry (한국산업의 계측투자실태분석)

  • Kim, Dong-Jin;Nam, Gyeong-Hui
    • Journal of Korean Society for Quality Management
    • /
    • v.20 no.2
    • /
    • pp.76-93
    • /
    • 1992
  • The purpose of this study, by surveying the status of firms, measurement-related investment and the defect rate, is to analyze the effect of measurement-related investment and to propose a scheme of efficient measurement-related investment which reduces the defect rate. For this project we obtain the data of the status of the measurement-related investment and the defect rate of 928 firms in Korean manufacturing industry by mailing survey. One of our results shows that the firms which have measurement standard laboratory, i.e, which invest in measurement-related area comparatively high, have the defect rate about 0.8% lower than those firms which don't have measurement standard laboratory. Also we find that the small-and-middle size firms have worse measurement-related facility than the large firms and the firms in the heavy-chemical industry have higher measurement-related investment effect than the firms in the light industry.

  • PDF

The use of the buccal fat pad flap for oral reconstruction

  • Kim, Min-Keun;Han, Wonil;Kim, Seong-Gon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.39
    • /
    • pp.5.1-5.9
    • /
    • 2017
  • Many congenital and acquired defects occur in the maxillofacial area. The buccal fat pad flap (BFP) is a simple and reliable flap for the treatment of many of these defects because of its rich blood supply and location, which is close to the location of various intraoral defects. In this article, we have reviewed BFP and the associated anatomical background, surgical techniques, and clinical applications. The surgical procedure is simple and has shown a high success rate in various clinical applications (approximately 90%), including the closure of oroantral fistula, correction of congenital defect, treatment of jaw bone necrosis, and reconstruction of tumor defects. The control of etiologic factors, size of defect, anatomical location of defect, and general condition of patient could influence the prognosis after grafting. In conclusion, BFP is a reliable flap that can be applied to various clinical situations.

Advanced electromagnetic wave-based method for characterizing defects in cement-based structures using time domain reflectometry

  • Dongsoo Lee;Jong-Sub Lee;Young K. Ju;Yong-Hoon Byun
    • Computers and Concrete
    • /
    • v.33 no.5
    • /
    • pp.621-630
    • /
    • 2024
  • This study presents novel electromagnetic wave-based methods for evaluating the integrity of cement-based structures using time domain reflectometry (TDR). Two cement-based plates with embedded rebars are prepared under sound and defective conditions. TDR tests are carried out using transmission lines with various numbers of artificial joints, and electromagnetic waves are measured to assess the integrity of the plates. The experimental results show that the travel time of electromagnetic waves is consistently longer in sound plates than in defective ones, and an increase in the reflection coefficients is observed in the defect zone of the defective plates. Electromagnetic wave velocities are higher in the defective plates, especially when connectors are present in the transmission line. A novel approach based on the area of the reflection coefficient provides larger areas in the defective plates, and the attenuation effect of the electromagnetic waves induces a difference in the areas of the reflection coefficient between the two defect conditions. An alternative method using the centroid of the defect zone slightly overestimates the location of the defect zone. The length of the defect zone is estimated using the defect ratio and wave velocities of cement, air, and plate. The length of the defect zone can also be calculated using the travel times within the plate, total measured length of the plate, and wave velocities in the cement and air. Therefore, the electromagnetic wave-based methods proposed in this study may be useful for estimating the location and length of defect zones by considering attenuation effects.

Analysis of the Effect of Small-Bore Piping Resonance Frequency on Defect of Welding Area (용접부의 결함이 소구경배관의 공진 주파수에 미치는 영향 분석)

  • Yoon, Min Soo;Song, Ki O;Lee, Jae Min;Ha, Seung Woo;Cho, Sun Young
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.5
    • /
    • pp.9-14
    • /
    • 2018
  • The piping system of a nuclear power plant plays a role of transferring high energy fluid to equipment and various devices. The safety and soundness of these piping systems are very closely related to the operability of the power plant. In the case of a welded part of a small diameter pipe, it may grow as a microcrack due to a lack of penetration, and it may grow to a size that affects the safety of the pipe due to the influence of mechanical vibration and fatigue load. Resonance refers to an increase in energy as the natural frequency of an object coincides with the frequency applied to the external force. When this resonance occurs, the frequency is the resonance frequency. In this study, when defects exist in the welds of small diameter pipe, the natural frequency of the pipe changes and resonance may occur. Since these resonances are likely to cause fatigue damage to the piping, resonance frequency changes due to the size and shape of the defects are analyzed and evaluated. As a result of the vibration test, the resonance frequency tended to decrease as the depth of the defect deepened, and the influence was larger when the defect existed at the bottom of the top of the trough. Also, it was confirmed that the Transverse cracks had an effect on the resonance frequency in the presence of the cracks in the weld bead, compared to the longitudinal cracks. As a result of this study, it is expected that the cause of the defect and the condition of the pipe can be monitored because the resonance frequency tendency according to the shape of the crack is analyzed.

The Effects of the Combination of Calcium Carbonate and Fibrin Adhesive on the Periodontal Regeneration of Class II Furcation Defect in Dogs (Calcium carbonate와 fibrin adhesive의 병용이 성견 2급 치근 분지부 치주조직 재생에 미치는 영향)

  • Seo, Eun-Pyo;Chung, Hyun-Ju;Kim, Young-Jun
    • Journal of Periodontal and Implant Science
    • /
    • v.30 no.2
    • /
    • pp.229-242
    • /
    • 2000
  • The purpose of this study was to evaluate the effect of fibrin tissue adhesive and porous resorbable calcium carbonate on the periodontal regeneration of the class II furcation defect in dogs. Class II furcation defect was surgically created on the second, third, and fourth premolars bilaterally in the mandibles of six mongrel dogs. The experimental sites were divided into four groups according to the treatment modalities: Control-surgical debridement only; Group I-calcium carbonate grafting; Group II-application of fibrin adhesive only; Group III-application of fibrin adhesive after calcium carbonate grafting. The animals were sacrificed at the 2, 4, and 12 weeks after periodontal surgery and the decalcified specimens were prepared for histological and histometrical examination. The results are as follows : Clinically, there were no inflammatory response in all groups after 2, 4, 12 weeks. In the Control group, junctional epithelium was grown downward to the reference notch. In Group I, graft materials were exfoliated from the defect throughout the experimenta periods andnew bone was seen in the notch area at 4 and 12 week specimens. In Group II, fibrin adhesive was absorbed at 2 week specimens, and connective tissue attachment increased than that of control group. New cementum and new bone were seen above the notch area. In Group III, the graft material was maintained in the defect throughout the experimental period and inducing the amount of periodontal tissue regeneration was higher than other groups. These results suggest that the use of fibrin tissue adhesive in conjunction with porous resorbable calcium carbonate would improves the stability of graft material and inhibit the epithelial down growth and make it be a feasible method for periodontal regeneration.

  • PDF

Optimization of Ingot Mold Design Parameters for Austenite Heat-resistant Steel Through Computational Simulation (전산모사를 통한 오스테나이트계 내열강용 잉곳 몰드 설계 파라미터 최적화)

  • Hwang, SooBeen;Park, JongHwa;Jo, SangHyun;Park, SeongIk;Kim, YunJae;Kim, Donggyu
    • Journal of Korea Foundry Society
    • /
    • v.42 no.1
    • /
    • pp.3-11
    • /
    • 2022
  • In this study, the parameters on the shrinkage defect of HR3C alloy was secured through computer simulation research, and the ingot mold with greater than 85% of sound area was designed and manufactured. Moreover, the optimized coagulation was proposed at design stage through computer simulation and test was performed upon ingot manufactured. After the test, the defect pattern was analyzed through cutting and non-destructive inspection to verify the parameter and ingot mold design. Based on the verification results, shrinkage defect parameters such as Niyama, Feed Efficiency, and Hot Tear Intensity of HR3C Alloys were obtained. In addition, through the secured parameters, a plan for designing ingot mold with a Non-defect area of 85% or more was secured.

The Natural Course and Size Change of Atrial Septal Defect Secundum (단순 이차성 심방 중격 결손의 자연 경과와 성장에 따른 결손의 크기 변화)

  • Choi, Deok Young;Choi, Jae Young;Kim, Mi Jin;Sul, Jun Hee;Lee, Sung Kyu
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.9
    • /
    • pp.871-875
    • /
    • 2003
  • Purpose : This study was performed to follow the natural course and size change of isolated atrial septal defect(ASD) secundum. Methods : Among the newly diagnosed with ASD secundum at the division of pediatric cardiology in Yonsei cardiovascular hospital from January 1996 to December 2000, 89 patients with pure ASD secundum were checked by the serial echocardiographic evaluation to measure the size change. Results : There was a statistical difference(P<0.05) in the rate of spontaneous closure and size change of the defect between the group of bigger defect(>8 mm) and the group of smaller defect (${\leq}8mm$). There was also a statistical difference(P<0.05) in the rate of spontaneous closure and size change of the defect between the group of younger than three years of age and the group of older than three years of age. The initial size of the defect and change of size were the significant influencing factors in the rate of spontaneous closing of ASD. In the group of patients who have persistent ASD, the size of defect showed a tendency of increasing size of defect with the age(P<0.005); however in the correction of these values by the body surface area of each patients, there was no statistical difference. Conclusion : The possibility of spontaneous closure of pure ASD secundum was higher in the group of patients who have smaller defect and who were younger. The ASD secundum that did not have spontaneous closure showed an increase in size with the growth of the patients; however when this size was corrected by the body surface area, there was no statistical difference. The closure of the defect was at 26.2 months of age so close follow-up of the patients is important.