• Title/Summary/Keyword: Defect Risk

Search Result 252, Processing Time 0.03 seconds

Study on Substitution Effect caused by Application of BIM Simulation System to Mock-up Site (시공단계 현장 Mock-up의 BIM 기반 시뮬레이션 기법 적용에 의한 기대효과 분석 연구)

  • Jang, Se-Jun;Yun, Seok-Heon;Paek, Joon-Hong
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2008.05a
    • /
    • pp.147-151
    • /
    • 2008
  • Construction project is completed through several stages and problems of each stage affect directly not only now but also next. Defect of 2D drawings influence in construction phase, and it make many loss on project. Nowadays we practically use real Mock-up test in construction sites to solve the problems. But it also has many problems which are waste much money and time. Therefore, this study tries to analyze effect that is occurred by appling BIM Mock-up simulation instead of real Mock-up execution. These analysis is conducted by comparing two construction building site. These have same shape but one is made for BIM Mock-up, and another is real Mock-up. Comparison points of view are cost, time and operator's satisfaction. It is expect that BIM Mock-up is more effective at low cost and on shorter time. But our analysis show that each are conducted different part of function. So new Mock-up type is required. Hybrid Mock-up is combine real mock-up with BIM simulation and it can minimize risk of project.

  • PDF

The Extracardiac Fontan Operation in Adult -A case report- (성인에서의 심외도관 Fontan 수술 - 1예 보고 -)

  • 배윤숙;정승혁;정성철;김우식;윤소영;이정호;김병열
    • Journal of Chest Surgery
    • /
    • v.37 no.1
    • /
    • pp.72-75
    • /
    • 2004
  • The Fontan operation is commonly practiced for the physiologic correction of univentricular heart diseases. However, for the patients who have risk factors against this operation, it is recommended to take the initial palliative operation rather than going to the Fontan operation at once. The proper timing to the Fontan operation after palliation is decided by assessing several factors such as patient's age and other risks of maintaining palliative state, etc. Usually, the Fontan operation is done relatively early after palliation stage. Here, we report a 36 years old-adult-female with univentricular heart disease who underwent the successful Fontan operation at 17 years after unidirectional Glenn procedure.

Application of Guided Ultrasonic Wave Technology for Evaluation of Welding Part in Cooling Water Pipe (냉각수 배관 용접부 평가를 위한 유도초음파 기술의 적용)

  • Gil, D.S.;Ahn, Y.S.;Park, S.K.
    • Journal of Power System Engineering
    • /
    • v.14 no.5
    • /
    • pp.36-40
    • /
    • 2010
  • The ultrasonic guided wave propagates along with the given structure's wall direction. Because of this specific character, the ultrasonic guided waves arc used in many other fields. Especially, it can be readily utilized for nondestructive inspection of various structures that are made up of gas pipes, heat exchanger tubes, and thin plates. Further, the guided wave technology can be readily utilized when inspecting pipes or thin plates which pose high risk of the accident but for which the nondestructive inspection itself is impossible because it is difficult to get to them since they are coated or buried underground. In the other hand, conventional ultrasonic testing such as thickness gauging uses bulk waves and only tests the region of structure immediately below the transducer. As a result of the application about inlet and outlet cooling water line using guided wave test, we conformed that the overall corrosions were in the lower side of the 304.8 mm inlet valve and these corrosions were engaged in not locally but through the lower side of the valve line. In the near future, we can expect that the detectable defect size is smaller than before along with the development of the sensing technology.

Experimental study on seismic performance of partial penetration welded steel beam-column connections with different fillet radii

  • Ge, Hanbin;Jia, Liang-Jiu;Kang, Lan;Suzuki, Toshimitsu
    • Steel and Composite Structures
    • /
    • v.17 no.6
    • /
    • pp.851-865
    • /
    • 2014
  • Full penetration welded steel moment-resisting frame (SMRF) structures with welded box sections are widely employed in steel bridges, where a large number of steel bridges have been in operation for over fifty years in Japan. Welding defects such as incomplete penetration at the beam-column connections of these existing SMRF steel bridge piers were observed during inspection. Previous experiments conducted by the authors' team indicate that gusset stiffeners (termed fillets in this study) at the beam-web-to-column-web joint of the beam-column connections may play an important role on the seismic performance of the connections. This paper aims to experimentally study the effect of the fillet radius on seismic performance of the connections with large welding defects. Four specimens with different sizes of fillet radii were loaded under quasi-static incremental cyclic loading, where different load-displacement relations and cracking behaviors were observed. The experimental results show that, as the size of the fillet radius increases, the seismic performance of the connections can be greatly improved.

Diagnosis of Medium Voltage Cables for Nuclear Power Plant

  • Ha, Che-Wung;Lee, Do Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.4
    • /
    • pp.1369-1374
    • /
    • 2014
  • Most accidents of medium-voltage cables installed in nuclear power plants result from the initial defect of internal insulators or the initial failure due to poor construction. However, as the service years of plants increase, the possibility of cable accidents is also rapidly increases. This is primarily caused by electric, mechanical, thermal, and radiation stresses. Recently, much attention is paid to the study of cable diagnoses. To date, partial discharge and Tan${\delta}$ measurements are known as reliable methods to diagnose the aging of medium-voltage cables. High frequency partial discharge measurement techniques have been widely used to diagnose cables in transmission and distribution systems. However, the on-line high frequency partial discharge technique has not been used in the nuclear power plants because of the plant shutdown risk, degraded measurement sensitivity, and application problems. In this paper, the partial discharge measurement with a portable device was tried to evaluate the integrity of the 4.16kV and 13.8kV cable lines. The test results show that the high detection sensitivity can be achieved by the high frequency partial discharge technique. The present technique is highly attractive to diagnose medium voltage cables in nuclear power plants.

Congenital Esophageal Atresia with Tracheoesophageal Fistula -A Case Report- (선천성 식도폐쇄 및 기관식도루 -1례 보고-)

  • Lee, Mun-Geum;Jang, Un-Ha
    • Journal of Chest Surgery
    • /
    • v.27 no.6
    • /
    • pp.489-493
    • /
    • 1994
  • Our patient was a 2.3 kg, male of 33 weeks gestation and spontaneous vaginal delivery. Copious salivary secretion, mild aspiration pneumonia episode due to tracheoesophageal fistula and intermittent cyanotic appearance due to hypoxia were noted shortly after birth. Head up position, frequent upper pouch suction, and adequate fluid and antibiotic therapy were done in incubator. Combined Chest and abdominal film was revealed gas in the stomach and an haziness in right chest with mediastinal shift to the right side. Esophagogram revealed markedly dilated proximal esophagus as blind pouch, and Two dimensional echocardiography showed the Ventricular Septal Defect. The conclusion was congenital esophageal atresia with tracheoesophageal fistula, Vogt-Gross type C, Waterston Risk Category B. Surgical correction with Beardmore anastomosis was performed extrapleurally through 3rd rib bed after the cannulation of umbilical vein and preliminary gastrostomy. The fistula was closed by triple ligation and the upper pouch was then brought down to the presenting surface of the lower esophageal segment that incised, and end to side anastomosis was underwent using interrupt suture placed through the full thickness of both upper pouch and lower esophageal segment. The postoperative patient was well tolerated and recovered uneventfully, permitted feeding on 7th postoperative day after esophagogram.

  • PDF

Intraoperative Neurophysiology Monitoring for Spinal Dysraphism

  • Kim, Keewon
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.2
    • /
    • pp.143-150
    • /
    • 2021
  • Spinal dysraphism often causes neurological impairment from direct involvement of lesions or from cord tethering. The conus medullaris and lumbosacral roots are most vulnerable. Surgical intervention such as untethering surgery is indicated to minimize or prevent further neurological deficits. Because untethering surgery itself imposes risk of neural injury, intraoperative neurophysiological monitoring (IONM) is indicated to help surgeons to be guided during surgery and to improve functional outcome. Monitoring of electromyography (EMG), motor evoked potential, and bulbocavernosus reflex (BCR) is essential modalities in IONM for untethering. Sensory evoked potential can be also employed to further interpretation. In specific, free-running EMG and triggered EMG is of most utility to identify lumbosacral roots within the field of surgery and filum terminale or non-functioning cord can be also confirmed by absence of responses at higher intensity of stimulation. The sacral nervous system should be vigilantly monitored as pathophysiology of tethered cord syndrome affects the sacral function most and earliest. BCR monitoring can be readily applicable for sacral monitoring and has been shown to be useful for prediction of postoperative sacral dysfunction. Further research is guaranteed because current IONM methodology in spinal dysraphism is still deficient of quantitative and objective evaluation and fails to directly measure the sacral autonomic nervous system.

Long V-Y advancement technique for large nipple reconstruction in Asian women

  • Jang, Nam;Kim, Junekyu;Shin, Hyun Woo;Suk, Sang Woo
    • Archives of Plastic Surgery
    • /
    • v.48 no.1
    • /
    • pp.44-48
    • /
    • 2021
  • Previously reported nipple-areolar complex reconstruction (NAR) methods involve multiple incisions and wide skin redraping, which increase retraction forces and heighten the risk of nipple-areolar complex (NAC) flattening. We introduce a NAR method using the long V-Y advancement technique that can overcome these disadvantages. A V-shaped flap is designed with the width of the flap base 4-5 mm larger than the diameter of the normal nipple. The flap length is designed to be at least 2.5 times its width. Dissection is performed to the top of the artificial dermal matrix or muscle layer. The nipple is constructed with the same projection as the contralateral side by folding the elevated flap. The tip of the elevated flap is apposed in the middle of the donor defect to minimize the deformity during donor site closure. A 3-point skin suture is applied to the upper third of the folded flap to mold its shape. Using this long V-Y advancement technique, we successfully decreased skin tension in NAC flaps and improved the maintenance of reconstructed nipple projection. The long V-Y advancement technique provides an easy, simple NAR method, effectively maintaining longer nipple projections and reducing breast deformities, especially in Asian women with relatively large nipples.

Modeling and Analysis of IGLAD Traffic Accident Case using Prescan for SOTIF Standard Development (SOTIF 표준 개발을 위한 Prescan 기반 IGLAD 교통사고 케이스 모델링 및 분석)

  • Sangjoong Kim;Dongha Shim
    • Journal of Auto-vehicle Safety Association
    • /
    • v.15 no.3
    • /
    • pp.53-58
    • /
    • 2023
  • Defects in the vehicle itself were considered the biggest risk factor for traffic accidents as the electrical and electronic components of vehicles, which were not there before, increase. Therefore, the vehicles have been developed based on ISO 26262 (an international functional safety standard) which is focusing on functional defect safety evaluation of electrical and electronic component systems. However, in the future, as autonomous driving technology is applied, even vehicles without functional defects must be prepared for the dangerous traffic situation that may arise from exceptional or external factors. SOTIF (Safety Of The Intended Functionality) is a concept to prevent exceptional or external factors. The main objective of SOTIF is to decrease Unknown & Unsafe factors as much as possible by finding Known factors and Unsafe factors. In this study, Prescan provided SIEMENS, one of the autonomous driving simulators, is used to make scenarios of IGLAD traffic accident cases. From the simulation results, Unsafe & Safe cases were classified and analyzed to derive unsafe factors.

Enoxaparin as an Anticoagulant in a Multipara with a Mechanical Mitral Valve: A Case Report

  • Yo Seb Lee;Jun Seok Kim
    • Journal of Chest Surgery
    • /
    • v.56 no.6
    • /
    • pp.452-455
    • /
    • 2023
  • Patients who have undergone mechanical valve replacement require anticoagulation therapy with warfarin to prevent thromboembolism. However, administering warfarin to pregnant patients increases their risk of warfarin embryopathy or central nervous system disorders. Consequently, safer alternatives, such as heparin or low-molecular-weight heparin injection, are substituted for warfarin. However, limited research has been conducted on this subject, with no large-scale studies and particularly few investigations involving multiparous patients. A patient who had previously undergone mechanical mitral valve replacement for atrial septal defect and mitral stenosis received anticoagulant therapy with enoxaparin during 2 pregnancies. Upon confirmation of pregnancy, warfarin was replaced with subcutaneously injected enoxaparin with a dosage of 1 mg/kg at 12-hour intervals. The enoxaparin dosage was controlled using an anti-factor Xa assay, with a target range of 0.3-0.7 IU/mL. Intravenous heparin injections were administered starting 3 days prior to the expected delivery date and were continued until delivery, after which warfarin was resumed. No complications were observed during the deliveries.