• 제목/요약/키워드: Decay rate

검색결과 606건 처리시간 0.024초

막 파단 및 공극크기에 따른 막 완결성 및 제거효율 분석 (Analysis of Membrane Integrity and Removal Efficiency Considering Membrane Defect and Pore Size)

  • 허현철;이옥재;이광제;김광호;최영준;이주희;홍승관
    • 한국물환경학회지
    • /
    • 제24권4호
    • /
    • pp.423-429
    • /
    • 2008
  • Microfiltration (MF) and ultrafiltration (UF) processes for removal of particulate materials (i.e., turbidity, microorganisms and viruses) have been used to produce drinking water with higher quality. As membrane filtration technique has become widely applied for drinking water treatment, the importance of membrane integrity test (MIT) has also been increasingly emphasized. The results of pressure decay test (PDT) were presented in the paper to monitor membrane integrity. In this paper the PDT was carried out with deliberately-defected membrane fibers to evaluate the sensitivity of PDT on membrane fiber damage. Variation of pressure decay rate and removal rate were investigated to evaluate the impact of defection (defection ratio) and pore size of membrane. The membrane integrity could be successfully monitored by the PDT. The pressure decay rate varied from $0.002{\sim}0.189kg_f/cm^2hr$ with the initial pressure ranged from 0.2 to $1.0kg_f/cm^2hr$. Higher initial pressure which provided with higher pressure decay rate was preferred to evaluate the defection of membrane fiber. As for the particle removal rate, the Log Removal Rate (LRV) of kaolin solution decreased significantly from 3.78 to 2.31 when one fiber out of 3,200 fibers was cut. The membranes with different pore size were tested to evaluate virus removal efficiency. The virus removal rate of the MF membrane ($0.1{\mu}m$) was about 30% although the poliovirus was smaller than the pore size of the MF membrane, indicating that the removal rate was much lower than Korea Water Works Association (KWWA) certificate LRV of 1.5.

SHIELD DESIGN OF CONCRETE WALL BETWEEN DECAY TANK ROOM AND PRIMARY PUMP ROOM IN TRIGA FACILITY

  • Khan, M J H;Rahman, M;Ahmed, F U;Bhuiyan, S I;Haque, A;Zulquarnain, A
    • Journal of Radiation Protection and Research
    • /
    • 제32권4호
    • /
    • pp.190-193
    • /
    • 2007
  • The objective of this study is to recommend the radiation protection design parameters from the shielding point of view for concrete wall between the decay tank room and the primary pump room in TRIGA Mark-II Research Reactor Facility. The shield design for this concrete wall has been performed with the help of Point-kernel Shielding Code Micro-Shield 5.05 and this design was also validated based on the measured dose rate values with Radiation Survey Meter (G-M Counter) considering the ICRP-60 (1990) recommendations for occupational dose rate limit ($10{\mu}Sv/hr$). The recommended shield design parameters are: (i) thickness of 114.3 cm Ilmenite-Magnetite Concrete (IMC) or 129.54 cm Ordinary Reinforced Concrete (ORC) for concrete wall A (ii) thickness of 66.04 cm Ilmenite-Magnetite Concrete (IMC) or 78.74 cm Ordinary Reinforced Concrete (ORC) for concrete wall B and (iii) door thickness of 3.175 cm Mild Steel (MS) on the entrance of decay tank room. In shielding efficiency analysis, the use of I-M concrete in the design of this concrete wall shows that it reduced the dose rate by a factor of at least 3.52 times approximately compared to ordinary reinforced concrete.

실내공기질 모델을 이용한 환기 시스템의 공기 정화 효율성 평가 (Evaluation of Ventilation System Performance Using Indoor Air Quality Model)

  • 최성우
    • 한국환경보건학회지
    • /
    • 제23권4호
    • /
    • pp.57-66
    • /
    • 1997
  • Successful energy conservation and good indcfor air quality (IAQ) are highly dependent on ventilation system. Air filtration is a primary solution of indoor air control strategies in terms of reducing energy consumption and improving ihdoor air quality. A conventional system with bypass filter, as it is called variable-air-volume/bypass filtration system (VAV/BPFS), is a variation of the conventional variable air volume (VAV) systems, which is designed to eliminate indoor air pollutant and to save energy. Bypass filtration system equipped with a high-efficiency particulate filter and carbon absorbent provides additional cleaned air into indoor environments and maintain good IAQ for human health. The objectives of this research were to compare the relative total decay rate of indoor air pollutant concentrations, and to develop a mathematical model simulating the performance of VAV/BPFS. All experiments were performed in chamber under the controlled conditions. The specific conclusions of this research are: 1. The VAV/BPFS system is more efficient than the VAV system in removing indoor air pollutant concentration. The total decay rates of aerosol, and total volatile organic compound (TVOC) for the VAV/BPFS system were higher than those of the conventional VAV system. 2. IAQ model predictions of each pollutant agree closely with the measured values. 3. According to IAQ model evaluation, reduction of outdoor supply air results in decreased dilution removal rate and on increased bypass filtration removal rate with the VAV/BPFS. As a results, we recommends the VAV/BPFS as an alternative to conventional VAV systems.

  • PDF

ENERGY DECAY FOR A VISCOELASTIC EQUATION WITH BALAKRISHNAN-TAYLOR DAMPING INVOLVING INFINITE MEMORY AND NONLINEAR TIME-VARYING DELAY TERMS IN DYNAMICAL BOUNDARY

  • Soufiane Benkouider;Abita Rahmoune
    • 대한수학회논문집
    • /
    • 제38권3호
    • /
    • pp.943-966
    • /
    • 2023
  • In this paper, we study the initial-boundary value problem for viscoelastic wave equations of Kirchhoff type with Balakrishnan-Taylor damping terms in the presence of the infinite memory and external time-varying delay. For a certain class of relaxation functions and certain initial data, we prove that the decay rate of the solution energy is similar to that of relaxation function which is not necessarily of exponential or polynomial type. Also, we show another stability with g satisfying some general growth at infinity.

단상 혐기성 소화공정에서의 동력학적 연구 (A Study on Kinetics in One-Phase Anaerobic Digestion)

  • 조관형;조영태
    • 한국환경과학회지
    • /
    • 제9권1호
    • /
    • pp.75-80
    • /
    • 2000
  • Kinetic data for the acid phase anaerobic digestion were presented in this study and the constants were determined with acid production rate and gas production rate. Process models based on continuous culture theory were used to describe the characteristics of the acid forming microorganisms and to enable further development toward utilization of the process in a more rational manner. Acid phase digestion can be separated with appropriate manipulation of hydraulic retention time in anaerobic digestion. Kinetic analysis of data from the various hydraulic retention times using a phase specific model obtained form the acid phase indicated maximum specific growth rate of 0.40/h, saturation constant of 2,000mgCOD.$\ell$, yield coefficient of 0.35 mgVSS/msCOD utilized and decay constant of 0.04/h for the acid production rate. Similar analysis of data for the gas production rate indicated maximum specific growth rate of 0.003/h, saturation constant of 2,200mgCOD/$\ell$, yield coefficient of 0.035 mgVSS/mgCOD utilized and decay constant of 0.06/h.

  • PDF

주택에서 Box Model을 이용한 평균 환기율 및 이산화질소 발생량 추정 (Estimation of Mean Air Exchange Rate and Generation Rate of Nitrogen Dioxide Using Box Model in Residence)

  • 배현주;양원호;손부순;김대원
    • 한국환경과학회지
    • /
    • 제13권7호
    • /
    • pp.645-653
    • /
    • 2004
  • Indoor air quality is affected by source strength of pollutants, ventilation rate, decay rate, outdoor level, and so on. Although technologies measuring these factors exist directly, direct measurements of all factors are not always practical in most field studies. The purpose of this study was to develop an alternative method to estimate these factors by application of multiple measurements. For the total duration of 30 days, daily indoor and outdoor $NO_2$ concentrations were measured in 30 houses in Brisbane, Australia, and for 21 days in 40 houses in Seoul, Korea, respectively. Using a box model by mass balance and linear regression analysis, penetration factor (ventilation divided by sum of air exchange rate and deposition constant) and source strength factor (emission rate divided by sum of air exchange rate and deposition constant) were calculated, Sub-sequently, the ventilation and source strength were estimated. In Brisbane, the penetration factors were $0.59\pm0.14$ and they were unaffected by the presence of a gas range. During sampling period, geometric mean of natural ventilation was estimated to be $l.l0\pm1.5l$ ACH, assuming a residential $NO_2$ decay rate of 0.8 hr^{-1}$ in Brisbane. In Seoul, natural ventilation was $1.15\pm1.73$ ACH with residential $NO_2$ decay rate of 0.94 hr^{-1}$ Source strength of $NO_2$ in the houses with gas range $(12.7\pm9.8$ ppb/hr) were significantly higher than those in houses with an electric range $(2.8\pm2,6$ ppb/hr) in Brisbane. In Seoul, source strength in the houses with gas range were $l6.8\pm8.2$ ppb/hr. Conclusively, indoor air quality using box model by mass balance was effectively characterized.

수하식 양식시설에 의한 운수저항의 평가와 수치모형 (Evaluation and Numerical Model of Hydraulic Resistance by Hanging Aquaculture Facilities)

  • 이종섭;박일흠
    • 한국수산과학회지
    • /
    • 제28권5호
    • /
    • pp.607-623
    • /
    • 1995
  • A numerical model of hydraulic resistance by hanging aquaculture facilities is developed and applied to a model basin and a field. A drag stress term formulated by the quadratic law of drag force is introduced Tn the equations of motion for a two-dimensional depth-averaged flow. In the model basin, numerical experiments ave tarried out for the various shape of obstructions, string density and layout of facilities etc.. The flow pattern around the facilities is affected sensitively by the density of string and the layout of facilities. On the other hand, the velocity decay due to the hanging oyster aquaculture facilities is observed in Kamak bay, where the maximum velcocity decay rate is $25\%$ in spring tide. The model is also applied to the field, Kamak bay. The velocity decay rate in the model is comparable with the field measurement data. The velocity decreases around the down-stream area of the facilities, .hut it increases in the other region. The water elevation decreases during the flood and it increases during the ebb.

  • PDF

Sputter etching에 의한 각종 섬유의 대전방지에 관한 연구 (A Study of Anti-Static Property of Several Fibers Treated with Sputter Etching)

  • Kim, Yong Hae;Koo, Bon Sik;Cho, Yeun Chung;Koo, Kang;Son, Tae Won
    • 한국염색가공학회지
    • /
    • 제9권6호
    • /
    • pp.10-17
    • /
    • 1997
  • In order to improve the anti-static property of several hydrophobic fibers by sputter etching, polyester, polypropylene and poly(p-phenylene sulfide) have been etched by sputtering in the presence of argon gas and the resulting anti-static property investigated by half time decay, the time of water permeation, weight loss rate and scanning electron microscope(SEM). The temporary change and durability of anti-static property of samples treated with sputter etching were evaluated. The results were as follows; 1) Half time decay of samples treated with sputter etching were decreased about 18~38%. According to increasing sputter etching time, half time decay is decreased. 2) The wettability and weight loss rate of treated samples were increased remarkably. According to the SEM photographs, many microcraters on the substrate surface by the sputter etching were observed. 3) Although the washing treatment and the time elapsed after treatment are allowed longer, the variation of half time decay hardly can find.

  • PDF

유역내 네가지 강수손실 성분들의 합성 (Combining Four Elements of Precipitation Loss in a Watershed)

  • 유주환
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2012년도 학술발표회
    • /
    • pp.200-204
    • /
    • 2012
  • In engineering hydrology, an estimation of precipitation loss is one of the most important issues for successful modeling to forecast flooding or evaluate water resources for both surface and subsurface flows in a watershed. An accurate estimation of precipitation loss is required for successful implementation of rainfall-runoff models. Precipitation loss or hydrological abstraction may be defined as the portion of the precipitation that does not contribute to the direct runoff. It may consist of several loss elements or abstractions of precipitation such as infiltration, depression storage, evaporation or evapotranspiration, and interception. A composite loss rate model that combines four loss rates over time is derived as a lumped form of a continuous time function for a storm event. The composite loss rate model developed is an exponential model similar to Horton's infiltration model, but its parameters have different meanings. In this model, the initial loss rate is related to antecedent precipitation amounts prior to a storm event, and the decay factor of the loss rate is a composite decay of four losses.

  • PDF

소용돌이 성분이 있는 축대칭유동의 중심난류 특성 (Centerline Turbulent Characteristics of an Axisymmetric Flow with the Swirl)

  • 남경덕;한용운
    • 대한기계학회논문집
    • /
    • 제18권10호
    • /
    • pp.2724-2737
    • /
    • 1994
  • The swirl effect on an axisymmetric turbulence has been investigated along its centerline by the hot wire anemometry. Flow facility to generate and conrol the swirl has been built by using the rotating honeycomb and grid. For the case of internal flows, as the strength of the swirl increases the flow tends to be locally isotropic by modifying the radial and the rotational components mainly. In comparison with those of the plain free jet, the decay of the centerline turbulences seems to be delayed substantially even with a slight swirl component.