• Title/Summary/Keyword: Decay Rate Method

Search Result 155, Processing Time 0.025 seconds

Developement and application of Statistical Hydrofracturing Data Processing Program (통계적 접근법에 의한 수압파쇄 자료해석용 전산 프로그램 개발 및 적용)

  • 류동우;최성웅;이희근
    • Tunnel and Underground Space
    • /
    • v.6 no.3
    • /
    • pp.209-222
    • /
    • 1996
  • Shut-in pressure, reopenting pressure and fracture orientation are very important parameters to be evaluated precisely in in-situ stress measurement by hydraulic fracturing. Graphical methods on pressure-time curves have been conventionally used, even though these are seriously dependent on subjectivity of interpreters. So there have been many demands on new method to objectivity in determining parameters. We have developed integrated hydrofracturing data processing program (HYDFRAC), based on nonlinear regression analysis and can be invoked under the Window graphical user interface. HYDFRAC consiste of three routines, that is shut-in pressure routine, reopening pressure routine, and fracture delineation routine. Each of routines include independent modules according to parameter determination methods. Its application to field tests ensured both objectivity and facility in determining of hydraulic fracturing parameters. Determining shut-in pressures at each pressurization cycles, we adopted the exponential pressure-decay method(EPD method), the bilinear pressure-decay-rate method (PDR method), and the tangent intersection method in order to find the pressurization-cyclic tendency of shut-in pressures. The estimated pressure by PDR method exists in the range of the upper and lower values by EPD method, and lies near to the upper value more than the lower. Being the pressurization cycle increased, the range of upper and lower limits come to be stabilized gradually. By graphical superposition method and bilinear pressure-accumulated volume method, reopening pressures were determined. Vertical and inclined fracture attitudes were determined by applying the directional statistics and sinusoidal curve fitting, respectively. The results of evaluation of hydrofracturing parameters showed that statistical methods could enhance the objectivity better than graphical methods.

  • PDF

Development of Standard Procedures for Local Leakage Rate Testing of Containment Vessel (격납건물 국부누설률시험 표준절차 개발)

  • Moon, Yong-Sig;Kim, Chang-Soo
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.8 no.2
    • /
    • pp.42-47
    • /
    • 2012
  • The containment local leakage rate testing in nuclear power plants is performed in accordance with ANSI/ANS 56.8-1994 in Korea. Two methods, the make-up flow rate and the pressure decay, are used for local leakage rate testing. Though ANSI/ANS 56.8-1994 does not define clearly the minimum test duration for the make-up flow rate method, it requires obtaining the data after reaching the stable condition. Thus the prerequisite stable condition for data acquisition and the testing time is differently applied to each NPPs. Therefore, this study presents a standardized test procedure for data stabilization and testing time through experiments to improve the test reliability.

The Calibration Method of Time Resolved Laser Induced Incandescence Using Carbon Black Particles for the Soot Measurement at Exhaust Tail Pipe in Engine (엔진 배기단 적용을 위한 Time Resolved Laser Induced Icandescence (TIRE-LII) 신호의 보정 : 카본 입자 이용)

  • Oh Kwang Chul;Kim Deok Jin;Lee Chun Hwan;Lee Chun Beom
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.12 s.243
    • /
    • pp.1335-1343
    • /
    • 2005
  • The calibration technique of Time Resolved Laser Induced Incandescence was investigated both experimentally and numerically by using standard-sized carbon black particles for the instantaneous soot measurement at exhaust tail pipe in engine. The carbon black particles (19nm, 25nm, 45nm and 58nm) used in this study are similar, though not identical, to soot particle generated from flame not only in morphology but also in micro-structure. The amount of soot loading in flow was controled by a diluted gas (nitrogen) and was measured by the gravimetric method at exhaust pipe in calibrator. The successful calibrations of primary particle size and soot mass fraction were carried out at the range from 19nm to 58nm and from $0.25mg/m^3$ to $37mg/m^3$ respectively. And based on these results the numerical simulation of LII signal was tuned and the effect of an exhaust temperature variation on the decay rate of LII signal was corrected.

Probe Diffusion in Polymer Solutions by Forced Rayleigh Scattering

  • Jaeyung Lee;Taiho Park;Jungmoon Sung;Sangwook Park;Taihyun Chang
    • Bulletin of the Korean Chemical Society
    • /
    • v.12 no.5
    • /
    • pp.569-574
    • /
    • 1991
  • Methyl red diffusion in polymer solutions was studied by a transient holographic method, forced Rayleigh scattering. In semi-dilute solutions of a polystyrene, where no specific interaction with the probe exists, we found within experimental uncertainty that the retardation of diffusion rate of methyl red is independent of the solvents used. This indicates that the hydrodynamic interaction in polymer coils is not affected by the nature of solvents enough to exhibit a detectable change in the diffusion rate of the probe. On the other hand, a substantial reduction of diffusion rate was observed in poly(methyl methacrylate) solutions in toluene. Together with the similar observation reported with poly(vinyl acetate), it is confirmed that hydrogen bond between the probe and the polymer is responsible for the retarded diffusion. The decay-growth-decay profile found in this system reveals a finite difference in diffusion coefficients of cis and trans isomer of methyl red. We estimate the difference and suggest that the cis isomer interacts with the polymer more strongly than the trans isomer.

Formation of CH3NH3PbBr3 Perovskite Nanocubes without Surfactant and Their Optical Properties

  • Kirakosyan, Artavazd;Yun, Seokjin;Kim, Deul;Choi, Jihoon
    • Journal of the Korean institute of surface engineering
    • /
    • v.51 no.1
    • /
    • pp.79-85
    • /
    • 2018
  • We systematically investigated the optical properties of sub-micron sized methylammonium lead tribromide ($CH_3NH_3PbBr_3$) cubes in the range of 100 to 700 nm, which were prepared by a surfactant-free precipitation method. We found that despite the strong absorbance, their photoluminescence quantum yield (PLQY) is very low as 0.009~0.011 % for whole range of sizes. Surfactant-free synthesis approach results in nanocubes that has no surface passivating reagents (e.g. surfactants) on their surface. As-prepared particles contain a large number of surface defects that may cause the low PLQY. The role of the surface defects were investigated in their photoluminescence decay process, which can be correlated with the particle size. Larger particles are characterized by a slower decay rate compared to smaller particles due to a large number of surface defects in the smaller particles that trap more excitons in the fluorescence decay process. These experimental results provide new insights into the fundamental relationship between surface state and optical properties.

Analysis of Ventilation Performance Using a Model Chamber

  • Kang Tae-Wook;Chang Tae-Hyeon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.7
    • /
    • pp.736-743
    • /
    • 2005
  • In this study, three different types of mechanical ventilation systems are compared based on their ventilation characteristics: tracer gas concentration decay characteristics, and ventilation effectiveness by calculating actual ventilation air flow rate. The experiments are performed by using a step-down method for measuring tracer gas. $CO_{2}$ gas, concentration in the model chamber. Application of a mixing factor, k, was used and measured values ranged from 0.68 to 0.77. The Type 2 ventilation system was found to have the highest ventilation effectiveness rather than the Types 1 and 3.

A NUMERICAL METHOD FOR CAUCHY PROBLEM USING SINGULAR VALUE DECOMPOSITION

  • Lee, June-Yub;Yoon, Jeong-Rock
    • Communications of the Korean Mathematical Society
    • /
    • v.16 no.3
    • /
    • pp.487-508
    • /
    • 2001
  • We consider the Cauchy problem for Laplacian. Using the single layer representation, we obtain an equivalent system of boundary integral equations. We show the singular values of the ill-posed Cauchy operator decay exponentially, which means that a small error is exponentially amplified in the solution of the Cauchy problem. We show the decaying rate is dependent on the geometry of he domain, which provides the information on the choice of numerically meaningful modes. We suggest a pseudo-inverse regularization method based on singular value decomposition and present various numerical simulations.

  • PDF

Water film covering characteristic on horizontal fuel rod under impinging cooling condition

  • Penghui Zhang;Bowei Wang;Ronghua Chen;G.H. Su;Wenxi Tian;Suizheng Qiu
    • Nuclear Engineering and Technology
    • /
    • v.54 no.11
    • /
    • pp.4329-4337
    • /
    • 2022
  • Jet impinging device is designed for decay heat removal on horizontal fuel rods in a low temperature heating reactor. An experimental system with a fuel rod simulator is established and experiments are performed to evaluate water film covering capacity, within 0.0287-0.0444 kg/ms mass flow rate, 0-164.1 kW/m2 heating flux and 13.8-91.4℃ feeding water temperature. An effective method to obtain the film coverage rate by infrared equipment is proposed. Water film flowing patterns are recoded and the film coverage rates at different circumference angles are measured. It is found the film coverage rate decreases with heating flux during single-phase convection, while increases after onset of nucleate boiling. Besides, film coverage rate is found affected by Marangoni effect and film accelerating effect, and surface wetting is significantly facilitated by bubble behavior. Based on the observed phenomenon and physical mechanism, dry-out depth and initial dry-out rate are proposed to evaluate film covering potential on a heating surface. A model to predict film coverage rate is proposed based on the data. The findings would have reliable guide and important implications for further evaluation and design of decay heat removal system of new reactors, and could be helpful for passive containment cooling research.

Study of Localized Surface Plasmon Polariton Effect on Radiative Decay Rate of InGaN/GaN Pyramid Structures

  • Gong, Su-Hyun;Ko, Young-Ho;Kim, Je-Hyung;Jin, Li-Hua;Kim, Joo-Sung;Kim, Taek;Cho, Yong-Hoon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.184-184
    • /
    • 2012
  • Recently, InGaN/GaN multi-quantum well grown on GaN pyramid structures have attracted much attention due to their hybrid characteristics of quantum well, quantum wire, and quantum dot. This gives us broad band emission which will be useful for phosphor-free white light emitting diode. On the other hand, by using quantum dot emission on top of the pyramid, site selective single photon source could be realized. However, these structures still have several limitations for the single photon source. For instance, the quantum efficiency of quantum dot emission should be improved further. As detection systems have limited numerical aperture, collection efficiency is also important issue. It has been known that micro-cavities can be utilized to modify the radiative decay rate and to control the radiation pattern of quantum dot. Researchers have also been interested in nano-cavities using localized surface plasmon. Although the plasmonic cavities have small quality factor due to high loss of metal, it could have small mode volume because plasmonic wavelength is much smaller than the wavelength in the dielectric cavities. In this work, we used localized surface plasmon to improve efficiency of InGaN qunatum dot as a single photon emitter. We could easily get the localized surface plasmon mode after deposit the metal thin film because lnGaN/GaN multi quantum well has the pyramidal geometry. With numerical simulation (i.e., Finite Difference Time Domain method), we observed highly enhanced decay rate and modified radiation pattern. To confirm these localized surface plasmon effect experimentally, we deposited metal thin films on InGaN/GaN pyramid structures using e-beam deposition. Then, photoluminescence and time-resolved photoluminescence were carried out to measure the improvement of radiative decay rate (Purcell factor). By carrying out cathodoluminescence (CL) experiments, spatial-resolved CL images could also be obtained. As we mentioned before, collection efficiency is also important issue to make an efficient single photon emitter. To confirm the radiation pattern of quantum dot, Fourier optics system was used to capture the angular property of emission. We believe that highly focused localized surface plasmon around site-selective InGaN quantum dot could be a feasible single photon emitter.

  • PDF

A Study on the Retention Characteristics with the Charge Injection Conditions in the Nonvolatile MNOS Memories (전하주입조건에 따른 비휘발성 MNOS 기억소자의 기억유지특성에 관한 연구)

  • Lee, Kyoung-Leun;Yi, Sang-Bae;Lee, Sang-Eun;Seo, Kwang-Yell
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.1265-1267
    • /
    • 1993
  • The switching and the retention characteristics with the injection conditions(pulse height and pulse width) were investigated in the nonvolatile MNOS memories with thin oxide layer of $23{\AA}$ thick. The shift of flatband voltage was measured using the fast ramp C-V method and experimental results were analized using the previously developed models. It was shown that the experimental results were described quit well by the trap-assisted and modified Fowler-Nordheim tunneling models for the voltage pulse of $15V{\sim}19V,\;24V{\sim}25V$, respectively. However, the direct tunneling model was agreement with experimental values in all range of pulse height. As increasing the initial shift of the flatband voltage, the decay rate was increased. But for the same initial shift of the flatband voltage, the decay rate was smaller for low and long pulse than for high and short one.

  • PDF