• Title/Summary/Keyword: Deadbeat control method

Search Result 70, Processing Time 0.021 seconds

A Development of Intelligent Robust Precision Control System for Power Conversion System using AI (첨단 AI 기법을 이용한 전력 변환기의 고성능 제어기 개발)

  • Ko, Jong-Sun;Lee, Yong-Jae;Kim, Kyu-Gyeom;Han, Hoo-Sek
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.92-95
    • /
    • 2001
  • This study presents neural load disturbance observer that used to deadbeat load torque observer and regulation of the compensation gain by parameter estimator. As a result, the response of PMSM fellows that of the nominal plant. The load torque compensation method is compose of a neural deadbeat observer. To reduce of the noise effect, the post-filter, which is implemented by MA process, is proposed. The parameter compensator with RLSM(recursive least square method) parameter estimator is suggested to increase the performance of the load torque observer and main controller. The proposed estimator is combined with a high performance neural torque observer to resolve the problems. As a result, the proposed control system becomes a robust and precise system against the load torque and the parameter variation. A stability and usefulness, through the verified computer simulation, are shown in this paper.

  • PDF

Design of Robust Double Digital Controller to Improve Performance for UPS Inverter (UPS 인버터의 성능 개선을 위한 강인한 2중 디지털 제어기의 설계)

  • 박지호;노태균;김춘삼;안인모;우정인
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.2
    • /
    • pp.116-127
    • /
    • 2003
  • In this paper, a new fully digital control method for UPS inverter, which is based on the double control loop such as the outer voltage control loop and inner current control loop, is proposed. In the proposed control system, overshoots and oscillations due to the computation time-delay are compensated by explicit incorporation of the time-delay in the current control loop transfer function. The inner current control loop is adopted by an Internal model controller The Internal model controller is designed to a second order deadbeat reference-to-output response which means that its response reaches the reference in two sampling time including computational time-delays. The outer voltage control loop employing P-Resonance controller is proposed. The resonance controller has an infinite gain at resonant frequency, and the resonant frequency is set to the fundamental frequency of the reference voltage in this paper. Thus the outer voltage control loop causes no steady state error as regard to both magnitude and phase. The effectiveness of the proposed control system has been verified by the simulation and experimental results respectively.

Development of Digital Controller and Monitoring System for UPS Inverter (UPS 인버터의 디지털 제어기 및 모니터링 시스템의 개발)

  • Park, Jee-Ho;Hwang, Gi-Hyun;Kim, Dong-Wan
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.1
    • /
    • pp.1-11
    • /
    • 2007
  • In this paper, a new fully digital control method for UPS inverter, which is based on the double control loop such as the outer voltage control loop and inner current control loop, is proposed. In the proposed control system, overshoots and oscillations due to the computation time-delay are compensated by explicit incorporation of the time-delay in the current control loop transfer function. The inner current control loop is adopted by an internal model controller. The internal model controller is designed to a second order deadbeat reference-to-output response which means that its response reaches the reference in two sampling time including computational time-delays. The outer voltage control loop employing P-Resonance controller is proposed. The resonance controller has an infinite gain at resonant frequency, and the resonant frequency is set to the fundamental frequency of the reference voltage in this paper. Thus the outer voltage control loop causes no steady state error as regard to both magnitude and phase. The effectiveness of the proposed control system has been verified by the simulation and experimental results respectively.

A Comparative Study on the Output Voltage Control Strategies of Three Phase Inverter with LC Filter for UPS (UPS 용 3상 인버터의 LC필터단 출력전압 제어 방식 비교연구)

  • Na, Woon-Ky;Kim, Tae-Wan;Jeong, Seung-Gi
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.312-317
    • /
    • 1996
  • This paper compares the output voltage control strategies of three-phase PWM inverter for uninterruptible power supply. The feedforward control, feedforward/feedback control, and decoupled feedback control in both the synchronous reference frame and the stationary reference frame are examined. In particular, it is shown that the response of the decoupled feedback controller in the synchronous reference frame can be improved by pole-zero cancellation method. It is also shown that the pole-zero cancellation method reduces to the deadbeat control, when it is implemented with digital controller.

  • PDF

Double-Objective Finite Control Set Model-Free Predictive Control with DSVM for PMSM Drives

  • Zhao, Beishi;Li, Hongmei;Mao, Jingkui
    • Journal of Power Electronics
    • /
    • v.19 no.1
    • /
    • pp.168-178
    • /
    • 2019
  • Discrete space vector modulation (DSVM) is an effective method to improve the steady-state performance of the finite control set predictive control for permanent magnet synchronous motor drive systems. However, it requires complex computations due to the presence of numerous virtual voltage vectors. This paper proposes an improved finite control set model-free predictive control using DSVM to reduce the computational burden. First, model-free deadbeat current control is used to generate the reference voltage vector. Then, based on the principle that the voltage vector closest to the reference voltage vector minimizes the cost function, the optimal voltage vector is obtained in an effective way which avoids evaluation of the cost function. Additionally, in order to implement double-objective control, a two-level decisional cost function is designed to sequentially reduce the stator currents tracking error and the inverter switching frequency. The effectiveness of the proposed control is validated based on experimental tests.

Robust speed control of induction motor using sliding mode state observer (슬라이딩모드 상태관측기를 이용한 유도전동기의 강인한 속도제어)

  • Yoon, Byung-Do;Kim, Yooo-Ho;Kim, Choon-Sam;Kim, Chan-Ki;Han, Jae-Hyeok
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.280-282
    • /
    • 1994
  • This paper proposes sliding mode state for robust speed control of induction motor. Sliding mode state observer is robust for measurement noise, modeling-error and load disturbance. The pole of sliding mode state observer can be placed at (0,0) in Z-plane for fast response. This method is, namely, deadbeat control. Sliding mode state observer output is discontinuous on a switching hyperplance, that causes harmful effects such as current harmonics and speed oscillation. In this paper, also the reducing method of the chattering of sliding mode state observer output is proposed. The proposed system is digitally implemented with TMS320C31.

  • PDF

Commutation Torque Ripple Reduction in Brushless DC Motor Drives Using a Single DC Current Sensor

  • Won Chang-hee;Lee Kyo-Beum;Bak Dae-Jin;Song Joong-Ho;Choy Ick;You Ji-Yoon
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.409-413
    • /
    • 2001
  • This paper presents a comprehensive study result on reducing commutation torque ripples generated in brushless dc motor drives with only a single dc-link current sensor provided. In brushless dc motor drives with only a single current sensor, the commutation torque ripple suppression that is practically effective in low speed as well as high speed regions has not been reported. A proposed commutation compensation technique based on deadbeat dc-link current controller takes a closed loop control scheme and a parameter insensitive property. The proposed control method is verified through simulations and experiments.

  • PDF

Robust Adaptive Precision Position Control of PMSM

  • Ko Jong-Sun;Ko Sung-Hwan;Kim Yung-Chan
    • Journal of Power Electronics
    • /
    • v.6 no.4
    • /
    • pp.347-355
    • /
    • 2006
  • A new control method for precision robust position control of a permanent magnet synchronous motor (PMSM) is presented. In direct drive motor systems, a load torque disturbance directly affects the motor shaft. The application of the load torque observer is published in using a fixed gain to solve this problem. However, the motor flux linkage cannot be determined precisely for a load torque observer. Therefore, an asymptotically stable adaptive observer base on a deadbeat observer is considered to overcome the problems of unknown parameters, torque disturbance and a small chattering effect. To find the critical parameters the system stability analysis is carried out using the Liapunov stability theorem.

Precision Position Control of Induction Motors using TCP-IP Network Board (TCP-IP네트워크 보드를 이용한 유도전동기의 정밀 위치 제어)

  • Kim, Hyun-Sik;Ko, Jong-Sun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.2
    • /
    • pp.221-228
    • /
    • 2008
  • This paper presents a new method for world wide network motor controlled system. It uses disturbance observer to present high precision position control algorithm to disturbance change, and to apply this to induction motors. It shows that proposed algorithm is strong in induction motor precision control for disturbance change. This system with disturbance observer used deadbeat control, which have high benefit, is good for quick disturbance compensation. To show these effectiveness the whole process is simulated by simulink, and also experimented by DSP6416 with TCP-IP network board.

Robust Internal Model Control of Three-Phase Active Power Filter for Stable Operation in Electric Power Equipment (전력설비의 안정한 운용을 위한 3상 능동전력필터의 강인한 내부모델제어)

  • Park, Ji-Ho;Kim, Dong-Wan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.10
    • /
    • pp.1487-1493
    • /
    • 2013
  • A new simple control method for active power filter, which can realize the complete compensation of harmonics is proposed. In the proposed scheme, a model-based digital current control strategy is presented. The proposed control system is designed and implemented in a form referred to as internal model control structure. This method provides a convenient way for parameterizing the controller in term of the nominal system model, including time-delays. As a result, the resulting controller parameters are directly set based on the power circuit parameters, which make tuning of the controllers straightforward task. In the proposed control algorithm, overshoots and oscillations due to the computation time delay is prevented by explicit incorporating of the delay in the controller transfer function. In addition, a new compensating current reference generator employing resonance model implemented by a DSP(Digital Signal Processor) is introduced. Resonance model has an infinite gain at resonant frequency, and it exhibits a band-pass filter. Consequently, the difference between the instantaneous load current and the output of this model is the current reference signal for the harmonic compensation.