• Title/Summary/Keyword: Deadbeat control method

Search Result 70, Processing Time 0.021 seconds

Control of Inverted Pendulum Using Continuous Time Deadbeat Control (연속계 Deadbeat제어를 적용한 도립진자 제어)

  • Kim, Jin-Yong;Kim, Seung-Youal;Lee, Keum-Won
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.555-558
    • /
    • 2004
  • Due to the asymptotic property, deadbeat control can hardly applied to the continuous time system control. But some delay element method can deal such a problem. Except delay element method, well-known digital deadbeat control can br used with the aid of som smoothing elements. In this paper, and order smoothing element is used for the smoothing of the digital deadbeat controller. And this element is argumented to the plant, and so control problem is to control digitally the argumented system. We simulated this control system using Matlab language and finally apply this algorithm to the rotary inverted pendulum system.

  • PDF

Servo System Control Using Continuous Time Deadbeat Controller (연속시간 유한정정제어기를 이용한 서보시스템 제어)

  • 김진용;김성은;김성열;이정국;이금원;이준모
    • Proceedings of the Korea Institute of Convergence Signal Processing
    • /
    • 2001.06a
    • /
    • pp.117-120
    • /
    • 2001
  • Deadbeat property is well established in digital control system design, But in continuous time, it can hardly realized for it's asymtotic property. But recently japanese researchers suggested serveral method for continuous time deadbeat property. They use delay elements In polynomials and established for the deadbeat condition. By solving this condition, unknown coefficients in polynomials with delay elements is obtained. In this paper, design method for optimal continuous time deadbeat servo system using 2nd order smooting elementsis studied. Continuous time deadbeat controller is consisted of serial integral compensator and local feedback one in state feedback loop. Determining method for damping rations and natural frequencies of smothing elements is described. By computer simulations, control inputs and system outputs are shown to have desirable property such as smoothness.

  • PDF

Control of Inverted Pendulum Using Continuous Time Deadbeat Control (연속계 Deadbeat 제어를 적용한 도립진자 제어)

  • Kim, Seung-Youal;Lee, Keum-Won
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.6
    • /
    • pp.108-113
    • /
    • 2004
  • Due to the asymptotic Property, deadbeat control can hardly be applied to the continuous time system control. But some delay element method can deal such a problem. Besides delay element nan well-known digital deadbeat control can be used by the aid of some smoothing elements. in this paper, 2nd order smoothing element is used for the smoothing or the digital deadbeat controller. And this element is argumented to the plant and so control problem is to control digitally the argumented system. We simulated this control system using Matlab language and finally apply this algorithm to the rotary inverted pendulum system.

Control of Inverted Pendulum Using Continuous Time Deadbeat Control

  • Lee, Ho-Jin;Kim, Seung-Youal;Lee, Jung-Kook;Kim, Jin-Yong;Lee, Seung-Hwan;Lee, Keum-Won;Lee, Jun-Mo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.510-513
    • /
    • 2005
  • Due to the asymptotic property, deadbeat control can hardly be applied to the continuous time system control. But some delay element method can deal such a problem. Besides delay element method, well-known digital deadbeat control can be used by the aid of some smoothing elements. In this paper, 2nd order smoothing element is used for the smoothing of the digital deadbeat controller. And this element is argumented to the plant, and so control problem is to control the argumented system digitally. We simulated this control system using Matlab language and finally apply this algorithm to the rotary inverted pendulum system.

  • PDF

Robust Deadbeat Current Control Method for Three-Phase Voltage-Source Active Power Filter

  • Nishida, Katsumi;Ahmed, Tarek;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • v.4 no.2
    • /
    • pp.102-111
    • /
    • 2004
  • This paper is concerned with a deadbeat current control implementation of shunt-type three-phase active power filter (APF). Although the one-dimensional deadbeat control method can attain time-optimal response of APF compensating current, one sampling period is actually required fur its settling time. This delay is a serious drawback for this control technique. To cancel such a delay and one more delay caused by DSP execution time, the desired APF compensating current has to be predicted two sampling periods ahead. Therefore an adaptive predictor is adopted for the purpose of both predicting the control error of two sampling periods ahead and bringing the robustness to the deadbeat current control system. By adding the adaptive predictor output as an adjustment term to the reference value of half a source voltage period before, settling time is made short in a transient state. On the other hand, in a steady state, THD (total harmonic distortion) of the utility grid side AC source current can be reduced as much as possible, compared to the case that ideal identification of controlled system could be made.

Stability of Sampled-Data Control Systems with Computer Interruptions (투명 PLZT 세라믹의 전기적 및 광 메모리 특성)

  • Jang, Seong-Whan
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.36 no.7
    • /
    • pp.476-483
    • /
    • 1987
  • This paper analyzes centralized sampled-data control systems with feedback loops which are closed through a digital computer which generates deadbeat control law. Intermittant computer interruptions result in failure to update the desired deadbeat design procedures for the deadbeat control law under normal operation of the control computer and the assumption of any admissible computer interruption are resented. A method that guarantees asymptotic stability under all admissible computer interruptions also is presented.

  • PDF

Realization of DeadBeat Controlled PWM Inverter using Reduced-Order State Observer (최소 차원 상태관측기를 사용한 DeadBeat 제어 PWM인버터의 실현)

  • Lee, C.D.;Shin, D.R.;Jeong, Bong-Chul;Kim, J.S.;Cho, Y.H.;Woo, J.I.
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.281-283
    • /
    • 1995
  • Deadbeat controlled PWM Inverter is realized. This PWM inverter performs the instantaneous control method which is based on the real-time digital feedback control and the microprocessor-based deadbeat control. For the deadbeat current controller, the system's order becomes a high order and increases computation delay time. Therefore, The delay tine produces current ripple. To minimize the current ripple, a new method based on deadbeat control theory for current regulation is proposed. It is constructed by a reduced-order state observer which predicts the output current in next sampling instant.

  • PDF

Low Parameter Sensitivity Deadbeat Direct Torque Control for Surface Mounted Permanent Magnet Synchronous Motors

  • Zhang, Xiao-Guang;Wang, Ke-Qin;Hou, Ben-Shuai
    • Journal of Power Electronics
    • /
    • v.17 no.5
    • /
    • pp.1211-1222
    • /
    • 2017
  • In order to decrease the parameter sensitivity of deadbeat direct torque control (DB-DTC), an improved deadbeat direct torque control method for surface mounted permanent-magnet synchronous motor (SPMSM) drives is proposed. First, the track errors of the stator flux and torque that are caused by model parameter mismatch are analyzed. Then a sliding mode observer is designed, which is able to predict the d-q axis currents of the next control period for one-step delay compensation, and to simultaneously estimate the model parameter disturbance. The estimated disturbance of this observer is used to estimate the stator resistance offline. Then the estimated resistance is required to update the designed sliding-mode observer, which can be used to estimate the inductance and permanent-magnetic flux linkage online. In addition, the flux and torque estimation of the next control period, which is unaffected by the model parameter disturbance, is achieved by using predictive d-q axis currents and estimated parameters. Hence, a low parameter sensitivity DB-DTC method is developed. Simulation and experimental results show the validity of the proposed direct control method.

Deadbeat Control of Three-Phase Shunt Active Power Filter Using Resonance Model (공진모델을 이용한 3상 병렬형 능동전력필터의 데드비트제어)

  • Park, Jee-Ho;Kim, Dong-Wan
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.56 no.3
    • /
    • pp.136-141
    • /
    • 2007
  • In this paper, a new simple control method for active power filter which can realized the complete compensation of the harmonic currents is proposed. In the proposed scheme, a compensating current reference generator employing resonance model implemented by a DSP(Digital Signal Processor) is introduced. Deadbeat control is employed to control the active power filter. The switching pulse width based SVM(Space Vector Modulation) is adopted so that the current of active power filter is been exactly equal to its reference at the next sampling instant. To compensate the computation delay of digital controller, the prediction of current is achieved by the current observer with deadbeat response.

Current Controlled PWN Inverter Using the Real-time Digital Feedback Control (실시간 디지털 궤환 제어(Deadbeat 제어)에 의한 전류 제어형 PWM 인버터에 관한 연구)

  • Lee, Jeong-Uk;Yoo, Ji-Yoon;Ahn, Ho-Gyun
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.2
    • /
    • pp.259-267
    • /
    • 1994
  • This paper describes a current control of a single-phase PWM inverter. The proposed PWM inverter utilizes the instantaneous control method which is based on the real-time digital feedback control and the microprocessor-based deadbeat control. The deadbeat current controller is proposed to control the output current regardless of load component variations by the same method as voltage control. That is, in current control, with a very short sampling time and the successive feedback of the output current, the load current is mainly effected by the magnitude of load impedance rather than load component, the load current is mainly effected by the magnitude of load impedance rather than load component. Therefore, by treating the load as an impedance, the system's order is reduced and the instantaneous current control using the proposed deadeat controller is simplified.