• 제목/요약/키워드: Dead-time correction

검색결과 22건 처리시간 0.02초

Spatial Compare Filter Based Real-Time dead Pixel Correction Method for Infrared Camera

  • Moon, Kil-Soo
    • 한국컴퓨터정보학회논문지
    • /
    • 제21권12호
    • /
    • pp.35-41
    • /
    • 2016
  • In this paper, we propose a new real-time dead pixel detection method based on spatial compare filtering, which are usually used in the small target detection. Actually, the soft dead and the small target are cast in the same mold. Our proposed method detect and remove the dead pixels as applying the spatial compare filtering, into the pixel outputs of a detector after the non-uniformity correction. Therefore, we proposed method can effectively detect and replace the dead pixels regardless of the non-uniformity correction performance. In infrared camera, there are usually many dead detector pixels which produce abnormal output caused by manufactural process or operational environment. There are two kind of dead pixel. one is hard dead pixel which electronically generate abnormal outputs and other is soft dead pixel which changed and generated abnormal outputs by the planning process. Infrared camera have to perform non-uniformity correction because of structural and material properties of infrared detector. The hard dead pixels whose offset values obtained by non-uniformity correction are much larger or smaller than the average can be detected easily as dead pixels. However, some dead pixels(soft dead pixel) can remain, because of the difficulty of uncleared decision whether normal pixel or abnormal pixel.

A Study on the Method of Nonlinearity Correction in a GM Counter

  • Ha, Chung-Woo;Yook, Chong-Chul;Philip S. Moon
    • Nuclear Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.137-144
    • /
    • 1978
  • 계측장치에서 관측한 계수율에 대한 비직선성 교정을 결정하는 한 방법을 제시하였다. 불감시간은 계수율이 의존성을 가지고 있다는 가정하에서 발전시킨 한 표현식은 실험결과와 잘 일치하였다. 계측장치의 펄스전압의 계수율에 따른 ,변화량을 파고분석장치를 이용하여 측정 하였다. 이 방법은 광범한 계수율 범위에 걸치어 불감시간에 대한 정착찬 값을 주었다. 개요한 이 측정기술로 불감손실로 인한 비직선성의 정확한 교정할 수 있었다. 불감시간은 계수율이 증가함에 따라 감소하는 것이 관측되었다.

  • PDF

Correction-Dead Reckoning using Map Matching Information in an Underground Parking Lot

  • Myung Hwan Seo;Jeeseon Kim;Sojin Park;Dongkwon Suh
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제12권4호
    • /
    • pp.391-398
    • /
    • 2023
  • In this paper, we propose a Correction Dead Reckoning (CDR) solution using correction information such as Map Matching FeedBack (MMFB) in an underground parking lot. In order to correct position errors in an underground parking lot, vehicle position and heading errors are corrected using MMFB information in road link properties. The proposed method was applied to an in-vehicle navigation system and tested. The experimental results show that the proposed robust dead reckoning solution corrects Dead Reckoning (DR) position errors that occur when driving for a long time in an underground parking lot.

$^{99m}Tc$, $^{123}I$, $^{131}I$을 이용한 갑상선 탐침의 계수 불능시간영향의 특성과 그의 보정 방법에 관한 연구 (The Effects of Dead Time and Its Correction Methods for Thyroid Prode using $^{99m}Tc$, $^{123}I$, $^{131}I$)

  • 손혜경;김희중;나상균;이희경
    • 한국의학물리학회지:의학물리
    • /
    • 제7권1호
    • /
    • pp.79-89
    • /
    • 1996
  • 목적 : $^{99m}Tc$, $^{123}I$, $^{131}I$과 lucite cylindrical phantom 을 이용 갑상선 탐침 (thyroid probe)의 계수불능시간 (dead time)을 알아본 후 그의 보정방법에 대해 알아보고자 하였다. 재료 및 방법 : 갑상선 탐침과 lucite cylindrical phantom 을 사용하여 $^{99m}Tc$ 10.5mCi는 약 43시간, $^{123}I$ 2.08mCi는 약 79시간동안 2시간 간격으로, $^{131}I$ 2.06mCi 는 약 910시간 동안 6시간 간격으로 medical spectrometer를 통해 계수하였다. 이때 실제 선량과 계수곡선을 이용 계수불능시간의 영향을 받기 시작하는 지점을 측정하기 위해 매 실험시 dose calibrator를 사용하여 선량을 측정하였다. 결과 : $^{99m}Tc$ 은 모든 거리에서 약 0.80mCi, $^{123}I$은 1.00mCi 지점에서 dead time의 영향을 받기 시작했다. 20%의 계수손실이 일어나는 지점에서의 방사능세기는 이 $^{99m}Tc$의 경우는 1.29 (center), 1.28(2cm), 1.31(4cm), 1.13(6cm)mCi 이었고 $^{123}I$은 1.39mCi 이었다. 각 방사능핵종에 대한 correction factor값의 일예로 선량이 2mCi 일 때 $^{99m}Tc$의 경우는 각각 1.52 (center), 1.52(2cm), 1.50(4cm), 1.58(6cm)이였고 $^{123}I$의 경우는 1.58이었다.

  • PDF

라이다 측정 거리 향상을 위한 통합 수신 시스템 개발 (아날로그방식과 광자계수방식 신호 접합) (Development of lidar detection system for improvement of measurement range (Combined photon counting detection and analog-to-digital signal))

  • 신동호;노영민;신성균;김영준
    • 대한원격탐사학회지
    • /
    • 제30권2호
    • /
    • pp.251-258
    • /
    • 2014
  • 본 연구는 에어로졸의 광학적 특성 분석을 위한 라이다 시스템의 정확성 향상을 위해 새롭게 개발한 신호 수신 시스템을 설명하고자 한다. 광주과학기술원의 라이다에 아날로그 방식과 광자계수 방식을 통합한 시스템을 활용하여 에어로졸 후방산란 신호를 동시에 관측 가능한 수신단을 개발하였다. 관측된 두 신호 결합을 위해 접합 알고리즘을 고안하였고, 신호 결합에 앞서 광자계수 방식 신호의 Pile up효과를 보정하기 위해 부동시간(Dead time)을 계산하여 보정하였다. 관측 신호 분석을 통해 아날로그 방식 신호, 광자계수 방식 신호, 접합신호 그리고 부동시간 보정에 따른 차이점을 설명하고, 최종적으로 에어로졸 후방산란계수를 산출하여 상호 비교 및 정확성 향상을 확인하였다.

A Novel Zero-Crossing Compensation Scheme for Fixed Off-Time Controlled High Power Factor AC-DC LED Drivers

  • Chang, Changyuan;Sun, Hailong;Zhu, Wenwen;Chen, Yao;Wang, Chenhao
    • Journal of Power Electronics
    • /
    • 제16권5호
    • /
    • pp.1661-1668
    • /
    • 2016
  • A fixed off-time controlled high power factor ac-dc LED driver is proposed in this paper, which employs a novel zero-crossing-compensation (ZCC) circuit based on a fixed off-time controlled scheme. Due to the parasitic parameters of the system, the practical waveforms have a dead region. By detecting the zero-crossing boundary, the proposed ZCC circuit compensates the control signal VCOMP within the dead region, and is invalid above this region. With further optimization of the parameters KR and Kτ of the ZCC circuit, the dead zone can be eliminated and lower THD is achieved. Finally, the chip is implemented in HHNEC 0.5μm 5V/40V HVCMOS process, and a prototype circuit, delivering 7~12W of power to several 3-W LED loads, is tested under AC input voltage ranging from 85V to 265V. The test results indicate that the average total harmonic distortion (THD) of the entire system is approximately 10%, with a minimum of 5.5%, and that the power factor is above 0.955, with a maximum of 0.999.

활로 4 징증의 외과적 치료 (Surgical Treatment of Patients with Tetralogy of Fallot)

  • 이재동;이종태;김규태
    • Journal of Chest Surgery
    • /
    • 제22권1호
    • /
    • pp.74-82
    • /
    • 1989
  • Ninety-six patients with tetralogy of Fallot have undergone either primary total correction [71], staged total correction [9], or an initial shunt [16], between January, 1984, and December, 1987 Their mean age was 9.5 years, mean body weight 24kg, and mean body surface area 0.86m2. Initial palliative shunt group had smaller size, smaller pulmonary artery, and higher hemoglobin [P value < 0.05 >. Modified Blalock-Taussig shunt was performed most commonly. Patch enlargement of right ventricle in 31 cases [38%], right ventricle and pulmonary artery in 7 cases [9%], transannular patch enlargement in 28 cases [35%], and valved conduit in 2 cases [2.5%] was performed for reconstruction of right ventricular outflow tract stenosis. Longer aorta cross clamp time was noted in case of separate patch enlargement of right ventricle and pulmonary artery, and dead patient with transannular patch enlargement [P value < 0.05]. There was no operative death in shunt group, but 7 deaths in total correction group [mortality rate 8.8%].

  • PDF

고해상도 어안렌즈 영상에서 움직임기반의 표준 화각 ROI 검출기법 (Motion-based ROI Extraction with a Standard Angle-of-View from High Resolution Fisheye Image)

  • 류아침;한규필
    • 한국멀티미디어학회논문지
    • /
    • 제23권3호
    • /
    • pp.395-401
    • /
    • 2020
  • In this paper, a motion-based ROI extraction algorithm from a high resolution fisheye image is proposed for multi-view monitoring systems. Lately fisheye cameras are widely used because of the wide angle-of-view and they basically provide a lens correction functionality as well as various viewing modes. However, since the distortion-free angle of conventional algorithms is quite narrow due to the severe distortion ratio, there are lots of unintentional dead areas and they require much computation time in finding undistorted coordinates. Thus, the proposed algorithm adopts an image decimation and a motion detection methods, that can extract the undistorted ROI image with a standard angle-of-view for the fast and intelligent surveillance system. In addition, a mesh-type ROI is presented to reduce the lens correction time, so that this independent ROI scheme can parallelize and maximize the processor's utilization.

역률개선회로를 갖는 에어컨용 전력변환장치 (Air-conditioner Power Conversion Equipment with Power Factor Correction Circuit)

  • 문상필;서기영;이현우;김영문
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권5호
    • /
    • pp.345-351
    • /
    • 2000
  • To improve the current waveform of diode rectifiers, we propose a new operating principle of the voltage diode rectifiers. In the conventional voltage rectifier circuit, relatively large capacitors are used to boost the output voltage, while the proposed circuit uses ones and a small reactor not boost the output voltage but improve the input current waveform. A circuit design method is shown and confirmed simulation. It explained that compared conventional PWM(Pulse-width modulated)inverter with HPWM(Half Pulse-width modulated)inverter. Proposed HPWM inverter eliminated dead-time by lowering switching loss and holding over-shooting. Output voltage and current of this paper were applied for real air-conditioner.

  • PDF

Inverter Air-conditioner Power System with Low Power Dissipation Type using Micro-controller

  • Mun, Sang-Pil;Shu, Ki-Young;Kim, Ju-Yong;Kim, Kwang-Tae
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 춘계학술대회 논문집
    • /
    • pp.492-496
    • /
    • 2004
  • When using a conventional power factor correction circuit, a comparatively huge capacitor is used to boost-up output voltage. It has a large amount of harmonic distortion in the input current waveform. To improve the input current waveform of diode rectifiers, we propose a new operating principle for the power factor correction circuit. Due to the fact that the proposed circuit uses smaller ones and a smaller reactor, the output voltage increases and obtains higher input current waveforms. These are suitable for the harmonics guidelines. The proposed circuit is able to obtain higher power factor and efficiency. Also, it has reduced switching loss and held over-shooting by using an inverter of eliminated dead-time HPWM that has non-linear impedance circuits to make up diodes, capacitance and a reactor. We compared the conventional PWM inverter and proposed HPWM inverters and found that a high input power factor of 97[%] and an efficiency of 98[%] were also obtained.

  • PDF