• Title/Summary/Keyword: Dead-time compensation

Search Result 94, Processing Time 0.024 seconds

The Analysis and Compensation of Dead Time Effects in a Vector-Controlled Induction Machine (벡터 제어 유도 전동기의 데드 타임 효과 해석 및 보상)

  • Kim, Seong-Hwan;Ryoo, Young-Jae;Chang, Young-Hak
    • Journal of IKEEE
    • /
    • v.4 no.2 s.7
    • /
    • pp.225-232
    • /
    • 2000
  • Dead time which is inserted in PWM signals of VSI distorts the inverter output voltage waveforms and deteriorate the control performance of an induction machine by producing torque ripples. In this paper, dead time compensation method in a vector controlled induction machine is proposed. The method is based on a feedforward approach that compensates dead time effect by adding the compensating voltages to the inverter output voltage references in 2 phase stationary frame. The proposed method is only software intensive and easy to realize without additional hardware. The experimental results show the validity and effectiveness of the proposed method.

  • PDF

Inverter Output Voltage Synthesis Using Novel Dead Time Compensation (새로운 데드타임보상법을 이용한 인버터 출력전압의 합성)

  • Choi, Jong-Woo;Sul, Seung-Ki
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.262-264
    • /
    • 1994
  • In is paper, a novel dead time compensation method is presented which produces inverter output voltages equal to reference voltages. An experimental result is also presented to demonstrate the validity of the proposed method. The reference voltage can be used as a feedback value, which is essential for sensorless vector control and flux estimation. The method can be carried out automatically by an inverter controller for initial set-up without any extra hardware.

  • PDF

A New Dead-Time Compenstion Method using Time Delay Control Approach (시간지연 제어기법을 이용한 새로운 데드 타임 보상법)

  • 김현수
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.425-428
    • /
    • 2000
  • A new dead time compensation method using time delay control approach is presented. The dead time in switching pattern cause the voltage distortion and it can be considered as the disturbance voltage. In this paper the disturbance voltage is estimated using time delay control and the estimated disturbance voltage is summed with voltage command in predictive current control by a feed-forward. The proposed scheme is implemented on a PMSM and the effectiveness is verified through comparative simulation.

  • PDF

Adaptive Time Delay Compensation Process in Networked Control System

  • Kim, Yong-Gil;Moon, Kyung-Il
    • International journal of advanced smart convergence
    • /
    • v.5 no.1
    • /
    • pp.34-46
    • /
    • 2016
  • Networked Control System (NCS) has evolved in the past decade through the advances in communication technology. The problems involved in NCS are broadly classified into two categories namely network issues due to network and control performance due to system network. The network problems are related to bandwidth allocation, scheduling and network security, and the control problems deal with stability analysis and delay compensation. Various delays with variable length occur due to sharing a common network medium. Though most delays are very less and mostly neglected, the network induced delay is significant. It occurs when sensors, actuators, and controllers exchange data packet across the communication network. Networked induced delay arises from sensor to controller and controller to actuator. This paper presents an adaptive delay compensation process for efficient control. Though Smith predictor has been commonly used as dead time compensators, it is not adaptive to match with the stochastic behavior of network characteristics. Time delay adaptive compensation gives an effective control to solve dead time, and creates a virtual environment using the plant model and computed delay which is used to compensate the effect of delay. This approach is simulated using TrueTime simulator that is a Matlab Simulink based simulator facilitates co-simulation of controller task execution in real-time kernels, network transmissions and continuous plant dynamics for NCS. The simulation result is analyzed, and it is confirmed that this control provides good performance.

Dead Time Compensation of Vector Controlled Inverter Using Space Vector Modulation Method (공간벡터 전류제어 기법을 이용한 벡터제어형 인버터의 dead time 보상)

  • Hong, Ki-Phil;Oh, Won-Seok;Kim, Young-Tae;Kim, Hee-Jun
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.265-269
    • /
    • 1994
  • The switching dead time avoiding a bridge leg short circuit in PWM voltage source inverter produces distortions of the controlling inverter output performance such as current waveform, voltage vector, and torque. In this paper, the influence of dead time is investigated. The on-line space voltage vector modulation method is used for current controller. It is possible to compensate dead time by space voltage vector modulation which generates additional pulse compensating voltage distortion caused by dead time. In addition, narrow pulse which is generally neglected can be compensated. All the algorithms, including field-oriented control are performed by one chip microprocessor 80C196MC and DSP TMS320C31. Experimental results probe that the proposed scheme provides a good inverter output performance.

  • PDF

New Dead Time Compensation Method in Voltage-Fed PWM Inverter (전압형 PWM 인버터에서의 새로운 데드 타임 보상 기법)

  • Ryu, Ho-Seon;Kim, Bong-Suck;Lee, Joo-Hyun;Lim, Ick-Hun;Hwang, Seon-Hwan;Kim, Jang-Mok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.5
    • /
    • pp.395-403
    • /
    • 2006
  • This paper has proposed a new dead time compensation method for a voltage-fed PMW inverter. In the voltage-fed PMW inverter, a voltage distortion is generated by the dead time effect and the nonlinear characteristics of the switching devices. Especially, the distorted voltage causes 5th and 7th harmonics in the stationary phase currents, and 6th harmonic in the synchronous phase currents. As a result, the integrator output of the synchronous PI current regulator has the ripple corresponding to six times of the inverter output frequency. In this paper, the signal of the integrator output of the d-axis current regulator is used as the control signal for the dead time compensation. The experimental and simulation results are presented to verify the validity of the proposed method.

Dead Time Compensation of Grid-connected Inverter Using Resonant Controller (공진 제어기를 이용한 계통 연계형 인버터의 데드타임 보상)

  • Han, Sang-Hyup;Park, Jong-Hyoung;Kim, Heung-Geun;Cha, Honn-Yong;Chun, Tea-Won;Nho, Eui-Cheol
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.6
    • /
    • pp.569-576
    • /
    • 2011
  • This paper proposes a new dead time compensation method for a PWM inverter. Recently, PWM inverters are extensively used for industry applications, such as ac motor drives, distributed grid-connected systems and a static synchronous compensator (STATCOM). Nonlinear characteristics of the switch and the inverter dead time cause a current distortion and deterioration of power quality. The dominant harmonics in the output current are the $5^{th}$ and $7^{th}$ harmonics in the stationary frame, and the $6^{th}$ harmonics in the synchronous rotating frame. In this paper, a resonant controller which compensates the $6^{th}$ harmonics in the synchronous rotating frame is proposed. This method does not require any off-line experimental measurements, additional hardware and complicated mathematical computations. Furthermore, the proposed method is easy to implement and does not cause any stability problem.

A Novel Zero-Crossing Compensation Scheme for Fixed Off-Time Controlled High Power Factor AC-DC LED Drivers

  • Chang, Changyuan;Sun, Hailong;Zhu, Wenwen;Chen, Yao;Wang, Chenhao
    • Journal of Power Electronics
    • /
    • v.16 no.5
    • /
    • pp.1661-1668
    • /
    • 2016
  • A fixed off-time controlled high power factor ac-dc LED driver is proposed in this paper, which employs a novel zero-crossing-compensation (ZCC) circuit based on a fixed off-time controlled scheme. Due to the parasitic parameters of the system, the practical waveforms have a dead region. By detecting the zero-crossing boundary, the proposed ZCC circuit compensates the control signal VCOMP within the dead region, and is invalid above this region. With further optimization of the parameters KR and Kτ of the ZCC circuit, the dead zone can be eliminated and lower THD is achieved. Finally, the chip is implemented in HHNEC 0.5μm 5V/40V HVCMOS process, and a prototype circuit, delivering 7~12W of power to several 3-W LED loads, is tested under AC input voltage ranging from 85V to 265V. The test results indicate that the average total harmonic distortion (THD) of the entire system is approximately 10%, with a minimum of 5.5%, and that the power factor is above 0.955, with a maximum of 0.999.

Dead Time Compensation and Polarity Check of Phase Currents Based on Programmable Low-pass Filter for Automotive Electric Drive Systems (자동차 전동 시스템을 위한 Programmable 저역 통과 필터 기반의 상전류 극성 판단 및 데드타임 보상)

  • Choi, Chinchul;Lee, Kangseok;Lee, Wootaik
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.22 no.6
    • /
    • pp.23-30
    • /
    • 2014
  • This paper proposes a dead time compensation method for an AC motor drive using phase current polarity information which is detected based on a digital programmable low-pass filter (PLPF). The polarity detection using the PLPF is an alternative solution of a conventional method which uses a general low-pass filter (LPF) and hysteresis bands in order to avoid jittering due to noises. The PLPF not only adjusts its cutoff frequency according to the synchronous frequency of AC motors but also eliminates a gain attenuation and phase delay which are main problems of the general LPF. Through the PLPF, a fundamental component signal without gain and phase distortions is extracted from the measured raw current signal with noise. By use of the fundamental component, the polarity of current is effectively detected by reducing the hysteresis band. Finally, the proposed method compensates the dead time effects by adding or subtracting average voltage value to voltage references of the controller according to the detected current polarity information. The proposed compensation method is experimentally verified by compared with the conventional method.

A New On-Line Dead-Time Compensator for Single-Phase PV Inverter (단상 PV 인버터용 온-라인 데드타임 보상기 연구)

  • Vu, Trung-Kien;Cha, Han-Ju
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.216-217
    • /
    • 2010
  • This paper presents a new software-based on-line dead-time compensation technique for single-phase grid-connected photovoltaic (PV) inverter system. To improve the mitigation of dead-time effect around the zero-crossing point of phase current, a selective harmonic elimination of instantaneous feedback current is used as an additional part of conventional current control scheme. Simulation and experimental results are shown to verify the effectiveness of proposed compensation method in the grid-connected power distributed generation systems.

  • PDF