• 제목/요약/키워드: Dead pressure

검색결과 155건 처리시간 0.037초

Clinical assessment of the efficacy of supraglottic airway devices compared with endotracheal tubes in cats during volume-controlled ventilation

  • Niyatiwatchanchai, Nutawan;Thengchaisri, Naris
    • Journal of Veterinary Science
    • /
    • 제21권2호
    • /
    • pp.27.1-27.10
    • /
    • 2020
  • The efficacies of a supraglottic airway device (SGAD) and an endotracheal tube (ETT) in cats under general anesthesia with volume-controlled ventilation (VCV) were compared. Thirty healthy cats were randomly allocated for airway control using either an SGAD or an ETT. Five tidal volumes (6, 8, 10, 12, and 14 mL/kg) were randomly tested, and respiratory rates were adjusted to achieve a minute ventilation of 100 mL/kg/min. The dose of propofol necessary to insert the SGAD or ETT, the static respiratory pressure, leakage during VCV, and end tidal CO2 (ETCO2) were recorded. Dosages of propofol and static respiratory measurements for the SGAD and ETT groups were compared using a t-test. The distribution of leakages and hypercapnia (ETCO2 > 45 mmHg) were compared using Fisher's exact test. A significance level of p < 0.05 was established. No significant difference in dose of propofol was observed between the SGAD and ETT groups (7.1 ± 1.0, 7.3 ± 1.7 mg/kg; p = 0.55). Static resistance pressure of the SGAD (22.0 ± 8.1 cmH2O/L/sec) was significantly lower than that of the ETT (36.6 ± 12.9 cmH2O/L/sec; p < 0.01). Of the 75 trials, leakage was more frequent when using an SGAD (8 events) than when using an ETT (1 event; p = 0.03). Hypercapnia occurred more frequently with SGAD (18 events) than with ETT (3 events; p < 0.01). Although intubation with an ETT is the gold standard in small animal anesthesia, the use of an SGAD can reduce airway resistance and the work of breathing. Nonetheless, SGAD had more dead space and the tidal volume for VCV needs adjustment.

Coagulant bath medium effect towards polylactic acid membranes structure and methylene blue dye removal

  • Amira M. Nasib;Stephen Simon;Syahmie M. Rasidi;Siti Kartini E. Ab. Rahim;Hoo Peng Yong;Ng Qi Hwa;Khairiraihanna Johari
    • Advances in materials Research
    • /
    • 제13권3호
    • /
    • pp.243-251
    • /
    • 2024
  • The asymmetric polylactic acid (PLA) membrane was prepared via phase inversion method using non-solvent induced separation (NIPS) technique. This study aims to synthesized as well as to characterize the PLA membrane and evaluating the membrane performance on water flux and permeability. In addition, this research also studied the removal performance of methylene blue dye. The polymer solution has been prepared using 12 wt.% of PLA and dissolved in 88 wt.% of Dimethylacetamide (DMAc) as a solvent. Then, the cast film was immersed in different ratio of coagulant bath medium (distilled water: methanol: ethanol) ranging from 100:0:0, 75:25:0, 75:0:25 and 75:12.5:12.5, respectively). Several characterizations were performed which include, membrane contact angle and membrane porosity. Performance PLA membranes were determined in terms of water flux and permeability at 1 bar transmembrane pressure using dead-end permeation cell. Finally, methylene blue (MB) removal efficiency was tested at the same transmembrane pressure. The findings revealed that the increase of alcohol concentration in coagulant bath resulted in higher porosity and lower contact angle. In short, MB dye rejection efficiency is also closely related to the amount of alcohol ratio used in coagulant baths. Increases in concentration of methanol and ethanol in coagulant bath medium increases the membrane porosity thus increased in efficiency of methylene blue rejection.

Design of Stochastic Movement Model Considering Sensor Node Reliability and Energy Efficiency

  • Cho, Do-Hyeoun;Yeol, Yun Dai;Hwang, Chi-Gon
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제12권3호
    • /
    • pp.156-162
    • /
    • 2020
  • Wireless Sensor Network (WSN) field is mainly studied to monitor and characterize large-scale physical environments to track various environmental or physical conditions, such as temperature, pressure, wind speed and humidity. WSN can be used in various applications such as wild surveillance, military target tracking and monitoring, dangerous environmental exploration and natural disaster relief. We design probabilistic mobile models that apply to mobile ad hoc network mobile environments. A probabilistic shift model proposed by dividing the number of moving nodes and the distance of travel into two categories to express node movement characteristics. The proposed model of movement through simulation was compared with the existing random movement model, ensuring that the width and variation rate of the first node node node node (FND) was stable regardless of the node movement rate. In addition, when the proposed mobile model is applied to the routing protocol, the superiority of network life can be verified from measured FND values. We overcame the limitations of the existing random movement model, showing excellent characteristics in terms of energy efficiency and stable in terms of changes in node movement.

Computational Study of Magnetically Suspended Centrifugal Blood Pump (The First Report: Main Flow and Gap Flow)

  • Ogami, Yoshifumi;Matsuoka, Daisuke;Horie, Masaaki
    • International Journal of Fluid Machinery and Systems
    • /
    • 제3권2호
    • /
    • pp.102-112
    • /
    • 2010
  • Artificial heart pumps have attracted the attention of researchers around the world as an alternative to the organ used in cardiac transplantation. Conventional centrifugal pumps are no longer considered suitable for long-term application because of the possibility of occurrence of blood leakage and thrombus formation around the shaft seal. To overcome this problem posed by the shaft seal in conventional centrifugal pumps, the magnetically suspended centrifugal pump has been developed; this is a sealless rotor pump, which can provide contact-free rotation of the impeller without leading to material wear. In Europe, clinical trials of this pump have been successfully performed, and these pumps are commercially available. One of the aims of our study is to numerically examine the internal flow and the effect of leakage flow through the gap between the impeller and the pump casing on the performance of the pump. The results show that the pressure head increases compared with the pump without a gap for all flow rates because of the leakage of the fluid through the gap. It was observed that the leakage flow rate in the pump is sufficiently large; further, no stagnant fluid or dead flow regions were observed in the pump. Therefore, the present pump can efficiently enhance the washout effect.

동맥간의 외과적 치료 (Surgical treatment of Truncus Arteriosus)

  • 전태국
    • Journal of Chest Surgery
    • /
    • 제24권2호
    • /
    • pp.143-152
    • /
    • 1991
  • From 1983, until June, 1990, 10 patients with various type of truncus arteriosus underwent total surgical correction including Rastelli procedure at Seoul National University Hospital. The age at operation ranged from 1 month to 9 years [mean 2.1 years]. Six patients had truncus type I, 3 patients had truncus type II, and one patients had truncus type IIIc. Right ventricular pulmonary artery continuity was established with a porcine valved conduit in 6 patients, mechanical valved conduit in 1 patient, and bovine pericardial conduit in 3 patients. The postoperative right ventricular /left ventricular pressure ratio ranged from 0.4 to 0.71 [mean 0.51${\pm}$0.14]. The lung histology revealed grade II pulmonary obstructive disease even at 4 month of age. Five patients were dead in hospital [50%], and they were less than 2 year of age. One patient, who had severs congestive heart failure preoperatively, died of low output syndrome and the other died of low output syndrome with postoperative bleeding. There were three death, because of a pulmonary hypertensive crisis that might have been prevented. Two of the five survivors had conduit failure over a mean follow up of 42 months [range 1 to 78 months]. Obstructed conduit was removed and a new conduit constructed using the conduit bed as the posterior wall and the patch of bovine pericardium and Dacron as patch the roof of the conduit. One patient died of acute cardiac failure during the operation. Although results in infants less than 2 years old have not been good, current improvement of intra-and postoperative care suggested that prompt repair is indicated for infants with truncus arteriosus.

  • PDF

DME 예혼합 압축 착화 엔진에서 밸브 양정과 개폐시기가 내부 배기가스 재순환과 연소에 미치는 영향 (Effect of Valve Lift and Timing on Internal Exhaust Gas Recirculation and Combustion in DME Homogeneous Charge Compression Ignition Engine)

  • 장진영;배충식
    • 한국자동차공학회논문집
    • /
    • 제17권4호
    • /
    • pp.93-100
    • /
    • 2009
  • Intake/exhaust valve timing and exhaust cam lift were changed to control the internal exhaust gas recirculation (IEGR) and combustion phase of homogeneous charge compression ignition (HCCI) engine. To measure the IEGR rate, in-cylinder gas was sampled during from intake valve close to before ignition start. The lower exhaust cam made shorter valve event than higher exhaust cam and made IEGR increase because of trapping the exhaust gas. IEGR rate was more affected by exhaust valve timing than intake valve timing and increased as exhaust valve timing advanced. In-cylinder pressure was increased near top dead center due to early close of exhaust valve. Ignition timing was more affected by intake valve timing than exhaust valve timing in case of exhaust valve lift 8.4 mm, while ignition timing was affected by both intake and exhaust valve timing in case of exhaust valve 2.5 mm. Burn duration with exhaust valve lift 2.5 mm was longer than other case due to higher IEGR rate. The fuel conversion efficiency with higher exhaust valve lift was higher than that with lower exhaust valve lift. The late exhaust and intake maximum open point (MOP) made the fuel conversion efficiency improve.

송전선로 점퍼선 횡진방지용 지지애자장치 개발 (Development of Hold on Swing a Jumper Support String for Overhead Transmission Line)

  • 백승도;민병욱;위화복;박기용;금의연;정헌수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.521-523
    • /
    • 2005
  • A Jumper wire is currently used to connect each fixed power line on both sides of dead end tower for overhead transmission line, but in case of a jumper wire swing under circumstances of typhoon, etc. and the air clearance is deficient then a flashover fault may Happen. Now the angle tower has the jumper support string to prevent a swing of jumper wire and to secure the air clearance between jumper wire and tower main body, but the flashover fault by swing of jumper wire was happened yl times across all over the country, because of the typhoon 'Rusa' in year 2002 and 'Maemi' in year 2003. This paper presents the design and development of 'Counter Weight' which enables to keep the swing angle of jumper wire under 40 degree in design condition to prevent a flashover fault by swing of jumper wire by a high wind pressure load in case of typhoon and have completed a mechanical and electrical characteristic test.

  • PDF

심장이식 1례보고 (Cardiac Transplantation; 1 Case Report)

  • 송명근
    • Journal of Chest Surgery
    • /
    • 제26권3호
    • /
    • pp.224-227
    • /
    • 1993
  • We experienced one case of orthotopic cardiac transplantation in a patient with end stage dilated cardiomyopathy. This 50 year-old female recipient was suffered from NYHA functional class IV cardiac failure and dependent upon intravenous inotropic support for 2 months [recipient category 1]. Her preoperative condition was grave with left ventricular ejection fraction of 20% and estimated systolic pulmonary arterial pressure [from Doppler study] was 50mmHg. The brain-dead donor was 31 year-old male with head trauma. The body sizes [weight, height] of the donor/recipient were 70 Kg, 165 cm / 43 Kg, 160 cm and appropriately overmatched. Preoperatively, identical ABO/Rh blood group [A+] and nonreacting HLA crossmatching were confirmed. On November 11 1992 cardiac transplantation was performed without complication. Multiple organ procurement team and heart transplantation team were organized the operation schedule appropriately to minimize the ischemic time. The pump time was 126 minutes and aortic crossclamping time of recipient heart was 73 minutes and, as a result, total ischemic time of the transplanted heart was 75 minutes. Postoperatively, the vital signs were stable with minimal inotropic support. The immunosuppressive therapy was commenced from preoperatively and cyclosporine, azathioprine, and corticosteroid were used as a combination therapy as scheduled and monitored with blood drug concentration, WBC count, renal function and most importantly regular endomyocardial biopsy.Now, 5 months after transplantation, the patient is in NYHA functional class II with minimal cardiac drug support.

  • PDF

Computer Models on Oxygenation Process in the Pulmonary Circulation by Gas Diffusion

  • Chang, Keun-Shik;Bae, Hwang
    • International Journal of Vascular Biomedical Engineering
    • /
    • 제4권1호
    • /
    • pp.9-16
    • /
    • 2006
  • In this article we introduce computer models that have been developed in the past to determine the concentration of metabolic gases, the oxygen and carbon dioxide, along the pulmonary circulation. The terminal concentration of these gases in the arterial blood is related with the total change of the partial pressure of the same gases in the alveoli for the time beginning with inspiration and ending with expiration. It is affected not only by the ventilation-perfusion ratio and the gas diffusion capacity of the lung membrane but also by the pulmonary defect such as shunt, dead space, diffusion impairment and ventilation-perfusion mismatch. Some pathological pulmonary symptoms such as ARDS and CDPD can be understood through the mathematical models of these pulmonary dysfunctions. Quantitative study on the blood oxygenation process using various computer models is therefore of foremost importance in order to monitor not only the pulmonary health but also the cardiac output and cell metabolism. Reviewed in this paper include the basic and advanced methods that enable numerical study on the gas exchange and on the arterial oxygenation process, which might depend on the various heart and lung physiological conditions listed above.

  • PDF

연약지반 방파제의 시공성능 및 장기침하에 관한 실험적 평가 (Experimental Evaluation of Construction Performance and Long-term Settlements in Soft Ground Breakwater)

  • 권오순;장인성;박우선;염기대
    • Ocean and Polar Research
    • /
    • 제25권spc3호
    • /
    • pp.385-392
    • /
    • 2003
  • A new type of soft ground breakwater was recently developed, which does not need ground improvement because of light weight and structural characteristics. The various studies about consolidation settlements and lateral behavior of proposed soft ground breakwater have been conducted. But, the systematic investigations on the construction performance and long-term settlements of new type breakwater has not been accomplished. In this study, construction simulation of soft ground breakwater with soil box model test and experiments of the long-term wave loaded breakwater were performed. The results of test shows that it is possible to compensate differential settlements by dead loading and/or suction pressure, and to reduce the consolidation settlements by preloading method. It was also found that the vertical and lateral displacements of long-term wave loaded breakwater were negligible.