Microstructural Effects on DC Bias Characters in FeSiBNi Amorphous Ribbon (FeSiBNi 비정질 리본의 열처리 조건에 따른 미세구조가 직류중첩특성에 미치는 영향)

  • 장용익;김종렬;송용설
    • Journal of the Korean Magnetics Society
    • /
    • v.10 no.1
    • /
    • pp.1-6
    • /
    • 2000
  • Amorphous Fe$_{79.7}$Si$_{9.3}$B$_{9.7}$Ni$_{1.4}$ ribbon alloys were fabricated by a single roll method. To enhance D. C. bias properties, the magnetic and micro-structural changes have been investigated as the variation of annealing time and condition. The D. C. bias properties were found to be directly related to micro-structural changes. Primary ${\alpha}$-Fe dendrites with 200∼300 nm showed the best D. C. bias properties, which resulted from the magnetic domain wall pinning effect. Due to the differences of cooling rate, the growth shape and distribution of the dendrites is divided into two areas.

  • PDF

A Location-Routing Problem for Logistics Network Integrating Forward and Reverse Flow (역물류를 고려한 통합물류망에서의 입지:경로문제)

  • Na, Ho-Young;Lee, Sang-Heon
    • IE interfaces
    • /
    • v.22 no.2
    • /
    • pp.153-164
    • /
    • 2009
  • An effective management for reverse flows of products such as reuse, repair and disposal, has become an important issue for every aspect of business. In this paper, we study the Location-Routing Problem (LRP) in the multi-stage closed-loop supply chain network. The closed-loop supply chain in this study integrated both forward and reverse flows. In forward flow, a factory, Distribution Center (DC) and retailer are considered as usual. Additionally in reverse flow, we consider the Central Returns collection Center (CRC) and disposal facility. We propose a mixed integer programming model for the design of closed-loop supply chain integrating both forward and reverse flows. Since the LRP belongs to an NP-hard problem, we suggest a heuristic algorithm based on genetic algorithm. For some test problems, we found the optimal locations and routes by changing the numbers of retailers and facility candidates. Furthermore, we compare the efficiencies between open-loop and closed-loop supply chain networks. The results show that the closed-loop design is better than the open one in respect to the total routing distance and cost. This phenomenon enlarges the cut down effect on cost as an experimental space become larger.

A Study on the Effects of Hot Phonon in Electron Transport at Millimeter-wave Frequencies (밀리미터 주파수에서 전자의 운동에 대한 Hot Phonon의 영향 연구)

  • 윤태섭
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.12
    • /
    • pp.1070-1078
    • /
    • 1998
  • A density of phonon is increased by application of electric field. At this time the phonon which has higher energy than around is called hot phonon is disappeared after 7 picosecond by scattering with electron and loss energy. Since the lifetime of phonon is very short, the effects of hot phonon can be neglected in the low speed semiconductor device, but it must be considered in high speed devices. DC and AC electric fields are applied to bulk GaAs, and the density of phonon is obtained and analyzed for its effects on electron velocity and electron distribution using Monte Carlo simulation method. Under high electric filed the density of hot phonon increased and energy of hot phonon is decreased by scattering with electron on the other hand the energy of electron is increased. Therefore electron move from central valley of conduntion band to satellite vallies and the valocity of electron decrease since the mass of electron in satellite vally is heavier than central vally. In millimeter wave frequencies, the effects of hot phonon increased at higher frequencies.

  • PDF

Cables Condition Assessment for Circulating Water Pump & Condenser Extraction Pump (발전소 순환수 및 복수 계통 케이블 건전성 평가)

  • Ha, C.W.;Han, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.614-615
    • /
    • 2007
  • There are roughly a hundred types of cables in power plants. The distribution of circuits in a nuclear plant is comprised of 20% instrument cables, 61% control cables, 13% AC power cables, 1% DC power cables, and 5% communication lines. In the nuclear power plant, medium voltage cables are generally included in the scope of systems reviewed for safety and are included in a plant's maintenance program. Medium voltage cables provide power to many critical components in plants, including feed water pumps, circulating water pumps, and condensate pumps. Among these cables, high temperature sections of cables feeding electrical power to the circulating water pump and the condenser extraction pump were found. The evaluation for these cables is performed to find the maximum allowable current and temperature. The result shows that the load current flowed about 85% of the allowable current ampacity, and the temperature of conductor at full load current did not exceed the limited temperature. Therefore, existing cables for circulating water pump and condenser extraction pump system are going to be used during design life.

  • PDF

Modelling and Analysis of Electrodes Erosion Phenomena of $SF_6$ Arc in a Laval Nozzle

  • Lee, Byeong-Yoon;Liau, Vui Kien;Song, Ki-Dong;Park, Kyong-Yop
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.972-974
    • /
    • 2005
  • The present work deals with the theoretical study of the effects of copper vapours resulting from the erosion of the electrodes on the properties of a SF6 arc in a Laval nozzle. Computations have been done for a DC arc of 1000A with upstream gas pressure of 3.75MPa. The arc plasma is assumed to be in local thermodynamic equilibrium(LTE). The sheath and non-equilibrium region around the electrodes are not considered in this model. However, its effects on the energy flux into the electrodes are estimated from some experimental and theoretical data. The turbulence effects are calculated using the Prandtl mixing length model. A conservation equation for the copper vapour concentration is solved together with the governing equations for mass, momentum and energy of the gas mixture. Comparisons were made between the results with and without electrodes erosion. It has been found that the presence of copper vapours cools down the arc temperature due to the combined effects of increased radiation and increased electrical conductivity. The copper vapour distribution is very sensitive to the turbulent parameter. The erosion of upstream electrode(cathode) has larger effects on the arc compared to the downstream electrode(anode) as the copper vapour eroded from the anode cannot diffuse against the high-speed axial flow.

  • PDF

Thermal Characteristics of 600 W Brushless DC Motor under Axial Loading Condition (회전축 부하를 고려한 BLDC 모터의 열적 특성에 관한 실험 및 수치 해석적 연구)

  • Kwon, Hwabhin;Lee, Won-Sik;Kim, Gyu-Tak;Park, Heesung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.12
    • /
    • pp.999-1005
    • /
    • 2016
  • A brushless direct current (BLDC) motor electronically performs rectification without brushes. It therefore does not have the typical mechanical friction contacts between the brushes and commutators. The BLDC motor has the advantages of high speed, low noise, and electronic noise reduction in addition to high durability and reliability. Therefore, it is mainly used in electric vehicles and electric equipment. However, iron loss and copper loss due to long-term use induce temperature increases in the motor, which reduces its performance and life. The temperatures of the stator and permanent magnet are predicted to be $62.3^{\circ}C$ and $32.2^{\circ}C$, respectively. This study shows the enhanced temperature distribution in a 600 W BLDC motor using unsteady and three-dimensional (3D) numerical investigations validated with experimental data.

Manufacturing and characterization of ECR-PECVD system (ECR-PECVD 장치의 제작과 특성)

  • 손영호;정우철;정재인;박노길;황도원;김인수;배인호
    • Journal of the Korean Vacuum Society
    • /
    • v.9 no.1
    • /
    • pp.7-15
    • /
    • 2000
  • An ECR-PECVD system with the characteristics of high ionization rat다 ability of plasma processing in a wide pressure range and deposition at low temperature was manufactured and characterized for the deposition of thin films. The system consists of a vacuum chamber, sample stage, vacuum gauge, vacuum pump, gas injection part, vacuum sealing valve, ECR source and a control part. The control of system is carried out by the microprocessor and the ROM program. We have investigated the vacuum characteristics of ECR-PECVD system, and also have diagnosed the characteristics of ECR microwave plasma by using the Langmuir probe. From the data of system and plasma characterization, we could confirmed the stability of pressure in the vacuum chamber according to the variation of gas flow rate and the effect of ion bombardment by the negative DC self bias voltage. The plasma density was increased with the increase of gas flow rate and ECR power. On the other hand, it was decreased with the increase of horizontal radius and distance between ECR source and probe. The calculated plasma densities were in the range of 49.7\times10^{11}\sim3.7\times10^{12}\textrm{cm}^{-3}$. It is also expected that we can estimate the thickness uniformity of film fabricated by the ECR-PECVD system from the distribution of the plasma density.

  • PDF

A Study on the Potassium Gettering in Al-1%Si/SiO2/PSG Multilevel Thin Films (Al-1%Si/SiO2/PSG 적층 박막에서 potassium 게터링에 관한 연구)

  • Kim, Jin Young
    • Journal of the Korean institute of surface engineering
    • /
    • v.48 no.5
    • /
    • pp.233-237
    • /
    • 2015
  • In order to investigate the potassium (K) gettering, Al-1%Si/$SiO_2$/PSG multilevel thin films were fabricated. Al-1%Si thin films and $SiO_2$/PSG passivations were deposited by using DC magnetron sputter techniques and APCVD (atmosphere pressure chemical vapor deposition), respectively. Heat treatment was carried out at $300^{\circ}C$ for 5 h in air. SIMS (secondary ion mass spectrometry) depth profiling analysis was used to determine the distribution of K, Al, Si, P, and other elements throughout the $SiO_2$/PSG passivated Al-1%Si thin film interconnections. Potassium peaks were observed throughout the $SiO_2$/PSG passivation layers, and especially the interface gettering at the $SiO_2$/PSG and at the Al-1%Si/$SiO_2$ interfaces was observed. Potassium gettering in Al-1%Si/$SiO_2$/PSG multilevel thin films is considered to be caused by a segregation type of gettering.

Comparison of middle-aged women's bodice pattern using 3D data -focused on the DC Suite program-

  • Cha, Su-Joung
    • Journal of the Korea Society of Computer and Information
    • /
    • v.23 no.1
    • /
    • pp.91-102
    • /
    • 2018
  • The purpose of this study is to develop an excellent bodice prototype that is adapted to the body shape of middle-aged women using 3D measurement data. In the evaluation of appearance, S pattern 4.00, B pattern 2.80, E pattern 2.40, L pattern 1.40 were shown in order, and the best fit of S pattern was evaluated as excellent. As a result of looking at the color distribution chart to find out the amount, E pattern and S pattern were not space in the front bust, armhole, and the back waist line. The B pattern and the L pattern were marked in blue because of insufficiency space in the back neck. As a result of evaluation the amount of air gap in the clothing, the air gap of the bust was 0.12, which is the largest pattern of B. Next, the L pattern appears as a tight circle with smallest air gap in the order of the S pattern 0.096, the E pattern 0.08, and the L pattern 0.003. The S pattern was evaluated to be the most appropriate for the body shape of middle-aged women. But the waist and back were slightly tight. Middle-aged women have larger shoulder-related items and larger waist circumference. Therefore, when you set the perimeter item, you should add 1-2cm of space amount and give extra space to the circumference area.

Fabrication of high-frequency therapy device for deep part and temperature distribution characteristic according to electrode condition of RET (심부투열용 고주파 치료기의 제작과 RET 전극조건에 따른 온도 분포 특성)

  • Jung, Jae-Won;Kim, Beong-Ju;Kim, Ki-Seon
    • Journal of Advanced Engineering and Technology
    • /
    • v.11 no.4
    • /
    • pp.267-271
    • /
    • 2018
  • A high-frequency therapy device with improved output by modifying a high-frequency stimulator was fabricated. The details of the design include generating part design, high-frequency transformer design, large output FET installation, DC voltage input part design and gate input driver design. Based on the real test using the pork meat, the temperature distributions according to the current electric transfer method, penetration depth, electrode diameter size were measured. In the CET method, the penetration depth was 0.5 cm and in the RET method, the penetration depth was 20 cm or more. In addition, it was confirmed that the temperature rise according to the penetration depth in the RET system was substantially constant, and the temperature rise was remarkable as the electrode diameter was small. As a result, it has been confirmed that the high frequency therapy device is highly affected by various conditions of the electrode.