• 제목/요약/키워드: Daylighting systems

검색결과 62건 처리시간 0.022초

실내 조경 식물의 생육을 고려한 4면형 아트리움의 형태변수별 자연채광 성능평가 (Evaluation of the daylight performance of four-sided atria with various well configurations for interior vegitation growth)

  • 송일학;김지현;송규동
    • KIEAE Journal
    • /
    • 제11권5호
    • /
    • pp.137-143
    • /
    • 2011
  • An atrium space, unlike ordinary office rooms, accommodates variety of activities such as moving and resting of people and usually houses variety of vegitation to improve amenity and indoor environment. Many atrium buildings in Korea have been designed by considering the environmental criteria for human beings, not for the vegitation in the atrium space. Especially the daylighting designs are mostly focused on the required illuminances for various visual tasks of the occupants and glare controls. As a result, some atrium spaces do not provide sufficient light to the interior plants. Consequently, these atrium spaces require a high level of electric lighting to compensate the deficit of natural light for the photosynthesis of the vegitation. The purpose of this study was to suggest design guidelines for 4-sided atrium spaces having different well indices (WI), plan aspect ratio (PAR), and cardinal orientation. The findings from this study might be referenced by building designers when designing or selecting canopy systems by considering the daylight performances of the uncovered atrium spaces. In the study, the daylight performance was evaluated in terms of daylight autonomy (DA).

주광(晝光) 대등형 가변조명(可變照明) 제어설비의 적용 및 통합성능 (Energy Efficient Lighting Control Facilities Related to Daylight Levels)

  • 김정태;김곤
    • 조명전기설비학회논문지
    • /
    • 제20권2호
    • /
    • pp.8-15
    • /
    • 2006
  • 에너지 절약형 광원의 대체와 아울러 최적 운용 기술의 개발만이 건축조명부분에 대한 에너지 절약의 잠재력을 현실화 시킬 수 있다고 판단된다. 광원의 효율을 향상시키는 것은 기술적인 한계와 많은 개발시간이 요구되는 반면에 조명제어의 최적화 기술은 많은 기술이 개발되어 사용되고 있는 상황이므로, 보다 지능적이고 복합적인 시스템 차원에서 효율을 높이기 위한 노력들이 이루어지고 있다. 특히 상업용 건물이나 사무소건물에 있어 고효율 형광등과 전자식 안정기의 도입이후에 에너지 절감방안의 대표적인 것은 조명제어라고 인식하고 있다. 본 연구에서 분석한 일반적인 사무소 공간의 경우, 주광과 인공조명을 통합제어할 때 담천공 조건에서 소등할 수 있는 주광의 유효 입사 거리는 창측에서 약 4[m]에서부터, 시간대에 따라 5[m]에 이르는 것으로 나타났다. 이는 실내에 설치된 인공 조명기구의 약 60[%] 이상이 소등될 수 있어 동일한 비율의 조명 에너지가 절감될 수 있는 잠재력을 나타낸다. 입사각과 태양광량의 상호 보완적 특성으로 인하여 주간 내내 일정한 주광의 유효거리가 확보되는 것으로 나타났다. 계절별 소등라인축의 이동범위는 실내에서 자연의 변화를 느끼게 해주는 정도의 바람직한 것으로 허용될 수 있을 것이며, 자연광에 가까운 광색을 가진 광원을 사용함으로써 쾌적한 조명을 유지할 수 있을 것이다.

자연채광 이용에 따른 조명에너지 평가용 노모그래프의 개발에 관한 연구 (Developement of Lighting Energy Estimation Nomograph by using Daylight)

  • 정유근;김정태
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1990년도 추계학술발표회논문집
    • /
    • pp.28-34
    • /
    • 1990
  • Lighting is one of the largest energy, integrated lighting system with daylight and artificial lighting has been suggested. In such system, perimeter zone can be illuminated by daylighting and the deep area of room by artificial lighting. So, the study is to develope estimation nomograph of lighting energy by turnning-off depth and lighting control systems during daytime. For the purpose, energy nomograph has been developed to apply to side-lit office guilding and the use and limitation of the nomograph has been discussed.

  • PDF

거울형 태양광 채광시스템의 공간유형별 적용현황 분석 (An Analysis on Applications of Mirror Sunlighting Systems to the Contemporary Buildings with Different Spatial Types)

  • 정주희;이종수;김정태
    • KIEAE Journal
    • /
    • 제8권6호
    • /
    • pp.27-38
    • /
    • 2008
  • Sunlighting offers the high quality of life and has potential to improve environment, economy and human comfort. Especially mirror sunlighting system has competitive power in price, saving energy and solving problems of sunshine lack. This study aims to analyze the adequate applications of mirror type sunlighting systems available in Korea to enhance the living environment. For the purpose, contemporary applications were analyzed by spatial characteristics, size and usage in Germany, Switzerland, Australia, Japan and Korea. As the results, they are being applied for the place with lack of sunshine in housings. For culture complex, they are usually applied for atrium. Nowadays, application of complex systems is increasing to solve sunshine lack and make uniform illuminance. Therefore both aesthetic and technical consideration is needed to apply the advanced mirror sunlighting systems in various spaces.

통합 채광시스템의 건물 냉난방 에너지 성능평가 (Building Energy Savings due to Incorporated Daylight-Glazing Systems)

  • 김정태;안현태;김곤
    • 조명전기설비학회논문지
    • /
    • 제19권6호
    • /
    • pp.1-8
    • /
    • 2005
  • 건물 내에 존재하는 자연광은 조명원으로 국한되지 않고 시각적, 심리적 자극을 통한 실내 환경의 질적 향상에 이르기까지 에너지절약 및 공간의 쾌적성에 큰 영향을 미친다. 유입되는 자연광량에 비례적으로 연동되는 건물에너지는 전기조명에너지를 절감시키고 난방 기간동안 일사열의 유입에 따른 난방에너지를 절감시킨다. 여름철에는 전기조명의 소등으로 인한 조명원의 발열량이 감소됨으로써 냉방부하의 감소에 이르기까지 포괄적인 영향을 미친다. 조명개발분야의 선진국에서는 에너지 절약형 광원의 대체와 아울러 자연채광과 통합된 최적 조명제어 기술의 운용만이 건물이 가지고 있는 에너지 절약의 잠재력을 현실화시킬 수 있다고 판단하고 있다. 따라서 본 연구는 일반적인 사무소 모델 공간의 에너지 절약형 인공조명을 대상으로 자연광 유입에 따른 연동적 조명제어 기법을 적용하는 경우를 대상으로, 인공조명의 소등량에 따른 조명에너지의 절감량과 이에 수반되는 냉방에너지의 점감량 및 일사열 취즉에 따른 겨울철 난방 부하 절감량을 분석함으로써 자연채광의 건물에너지에 대한 연간 기여도를 통합 분석하였다. 특히 자연채광의 성능은 실험을 통한 측정 데이터를 이용하고 에너지 해석 프로그램을 재구성하여 실질적인 절감량을 도출하도록 시도하였다.

광센서 조광제어시스템의 소비전력 평가 (Evaluation of Energy Consumptions in Daylight Responsive Dimming Systems)

  • 이순지;최안섭
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.195-199
    • /
    • 2006
  • This study aims to measure amount of the reduction ratio of energy consumptions by the daylight responsive dimming systems, which uses daylighting and electric lighting. The results of this study show that the reduction ratio of electric power is better 'clear sky' by sky condition and 'window side of room' by zoning. When calculating reduction ratio of energy consumptions with used times in real office space, it tells that the result of real office was higher ratio than that of experimental space. For this study which presents efficient use of daylight in office environment, it will be basis of improving energy performance.

  • PDF

태양정밀추적 알고리즘의 LabVIEW 적용 연구 (The Study on the Application of Accurate Solar Tracking Algorithm by using LabVIEW)

  • 오승진;김영민;이윤준;조일식;천원기
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.121-125
    • /
    • 2009
  • There have been many developed systems for harnessing the solar energy such as solar water heaters, solar thermal power systems, PV systems, daylighting and solar hydrogen systems. all of them are capable of reducing $CO_2$ emission. However, the efficiency of those systems which work without a solar tracker is lower. This paper is a step by step procedure for fabrication and a performance test of a solar tracking system. The system developed in this study consists of motion controllers, motor drives, step-motors, feedback devices and application. CdS sensors are introduced into the solar tracking system for playing a primary role in poor conditions for tracking due to a gear backlash and a strong wind. Mini-dish was used as a concentrator for collecting sun light. The solar position data, in terms of azimuth and elevation, sunrise and sunset times was compared with those of KASI(Korea Astronomy & Space Science Institute). The results presented in this article provide the high accuracy of the present system in solar tracking and indicate a potential for energy savings.

  • PDF

혼합형 채광조절장치가 실내공간의 주광조도분포에 미치는 영향에 관한 Mockup 실험평가 (Light Factor Performance of a Room with Light Guide and Blind Systems by Mockup Experiments)

  • 신화영;김정태
    • KIEAE Journal
    • /
    • 제7권1호
    • /
    • pp.23-31
    • /
    • 2007
  • This study aims to evaluate the illuminance performance of sloped light guide with automated venetian blind systems. For the purpose, a mock-up model was constructed as a prototype of Korean office building with $12.0m{\times}7.3m{\times}3.7m$ ($w{\times}d{\times}h$) and south facing side-window mounted between the clerestory window($2.0m^2$) and the view window($5.6m^2$). The light guide of 1.28m deepth and $29^{\circ}$ tilted angle, is covered with 0.6mm galvanized steel sheet and 97% reflective film. To protect the room from low solar angle, a blind systems, 0.15m deepth and $30^{\circ}$ automated slat angle was installed. To assess illuminance performance, the totally 37 measuring points for illuminance were monitored. For the detailed analysis, photometric sensors were installed at work-plane (8 points), wall (7 points), ceiling (3points), and exterior horizontal illuminance (1 point) respectively. The performance was measured under clear sky and is monitored by Agilent data logger, photometric sensor Li-cor and the Radiant Imaging ProMetric 1400. Comparisons of light factor and uniformity are discussed.

결정면 적용 광선반 채광성능 평가 연구 (A Study on Lighting Performance Evaluation of Light-Shelf using Crystal Face)

  • 이행우;;서장후;김용성
    • 설비공학논문집
    • /
    • 제27권8호
    • /
    • pp.395-401
    • /
    • 2015
  • Recently, many research studies have been carried out on the efficiency of light-shelf daylighting systems, especially comparing performance improvements and the limitations of reflective surfaces and their lighting performance. In this study, a crystal face reflective surface is proposed. The objective of the study is to evaluate the lighting performance of a crystal face light-shelf through a performance study. The performance study was carried out in a full scale test-bed in order to calculate the light distribution and energy consumption utilizing the standard indoor illumination as an index. The conclusions of the performance study are as follows. 1) The optimal angle of incidence for daylighting for both the operable flat type light-shelf and the crystal face light-shelf are taken in the natural environment on the dates of the winter and summer solstices, as well as the autumn and spring equinoxes. 2) The application and installation of the crystal face light-shelf can produce a 29.9%~34.3% increase of light distribution within the indoor space. However, the increase of light distribution can also lead to a decrease in the uniformity ratio, a design challenge that should be considered when applying a crystal face light-shelf. 3) It is possible to achieve a 7.98%~13.3% greater reduction in energy consumption when applying a crystal face light-shelf than when applying a flat type light-shelf. The increase in the number of crystal faces should concur with the analysis of the energy reduction. A limitation of the study is that only one predetermined pattern was performance tested for a crystal face light-shelf. In order to carry out further research on crystal face light-shelves, additional performance studies are needed based on alternative patterns and designs.

Analysis of energy and daylight performance of adjustable shading devices in region with hot summer and cold winter

  • Freewan, Ahmed A.;Shqra, Lina W.
    • Advances in Energy Research
    • /
    • 제5권4호
    • /
    • pp.289-304
    • /
    • 2017
  • Large glazed surfaces and windows become common features in modern buildings. The spread of these features was influenced by the dependence of designers on mechanical and artificial systems to provide occupants with thermal and visual comfort. Countries with hot summer and cold winter conditions, like Jordan, require maximum shading from solar radiation in summer, and maximum exposure in winter to reduce cooling and heating loads respectively. The current research aims at designing optimized double-positioned external shading device systems that help to reduce energy consumption in buildings and provide thermal and visual comfort during both hot and cold seasons. Using energy plus, a whole building energy simulation program, and radiance, Lighting Simulation Tool, with DesignBuilder interface, a series of computer simulations for energy consumption and daylighting performance were conducted for offices with south, east, or west windows. The research was based on comparison to determine the best fit characteristics for two positions of adjustable horizontal louvers on south facade or vertical fins on east and west facades for summer and winter conditions. The adjustable shading systems can be applied for new or retrofitted office or housing buildings. The optimized shading devices for summer and winter positions helped to reduce the net annual energy consumption compared to a base case space with no shading device or with curtains and compared to fix shading devices.