반사거울 방식을 이용한 중정 내 자연채광 성능 분석 연구 (A Study on Daylighting Performance of an Inner Court with Reflecting Mirror System)

  • 박병윤;최창호
    • 한국태양에너지학회 논문집
    • /
    • 제31권4호
    • /
    • pp.112-121
    • /
    • 2011
  • To lead lighting inside, design solution and mechenical solution can be used.A inner court and atrium are samples for design solution. However, physical and environmental elements for building design are not taken positively into consideration. So low position of the inner court is difficult to reach lighting performance and a urban landscape gets damaged. On this study, selecting a building with a inner court, best design method is suggested to apply reflecting mirror. building direction, building shape and solar position are considered to deside the setting angle for reflecting mirror. Performance for the setting reflecting mirror is verified through various simulation cases, and is got more lighting performance than the present situation on the building inside.

시뮬레이션 분석을 통한 반사거울 시스템의 터널 적용성 연구 (A study on applicability of mirror reflector system in tunnel using simulation)

  • 이범석;이근일;정인영
    • 한국터널지하공간학회 논문집
    • /
    • 제13권5호
    • /
    • pp.371-383
    • /
    • 2011
  • 터널은 밝기가 급변하는 공간으로 운전자의 안전을 위해 조도의 확보가 중요하고, 터널의 조명설비는 주간과 야간에 모두 운영되고 있어 많은 전기 에너지가 소비되고 있다. 따라서 본 연구는 주간에 터널의 자연채광을 효율적으로 이용하여 에너지를 절약할 수 있는 방안으로 RADIANCE 시뮬레이션 프로그램을 사용하여 자연채광 반사거울 시스템의 채광 성능을 평가해 보았다. 프로그램을 사용하여 바(bar)형식과 폴(pole)형식으로 구분하여 벽면과 바닥면으로 주광을 유입한 결과 터널입구부로부터 20 m에서 바형식의 형태가 터널내부의 높은 조도를 확보하는 것으로 나타났다.

주광(晝光) 대등형 가변조명(可變照明) 제어설비의 적용 및 통합성능 (Energy Efficient Lighting Control Facilities Related to Daylight Levels)

  • 김정태;김곤
    • 조명전기설비학회논문지
    • /
    • 제20권2호
    • /
    • pp.8-15
    • /
    • 2006
  • 에너지 절약형 광원의 대체와 아울러 최적 운용 기술의 개발만이 건축조명부분에 대한 에너지 절약의 잠재력을 현실화 시킬 수 있다고 판단된다. 광원의 효율을 향상시키는 것은 기술적인 한계와 많은 개발시간이 요구되는 반면에 조명제어의 최적화 기술은 많은 기술이 개발되어 사용되고 있는 상황이므로, 보다 지능적이고 복합적인 시스템 차원에서 효율을 높이기 위한 노력들이 이루어지고 있다. 특히 상업용 건물이나 사무소건물에 있어 고효율 형광등과 전자식 안정기의 도입이후에 에너지 절감방안의 대표적인 것은 조명제어라고 인식하고 있다. 본 연구에서 분석한 일반적인 사무소 공간의 경우, 주광과 인공조명을 통합제어할 때 담천공 조건에서 소등할 수 있는 주광의 유효 입사 거리는 창측에서 약 4[m]에서부터, 시간대에 따라 5[m]에 이르는 것으로 나타났다. 이는 실내에 설치된 인공 조명기구의 약 60[%] 이상이 소등될 수 있어 동일한 비율의 조명 에너지가 절감될 수 있는 잠재력을 나타낸다. 입사각과 태양광량의 상호 보완적 특성으로 인하여 주간 내내 일정한 주광의 유효거리가 확보되는 것으로 나타났다. 계절별 소등라인축의 이동범위는 실내에서 자연의 변화를 느끼게 해주는 정도의 바람직한 것으로 허용될 수 있을 것이며, 자연광에 가까운 광색을 가진 광원을 사용함으로써 쾌적한 조명을 유지할 수 있을 것이다.

태양추적식 자연채광 장치의 집광기 종류에 따른 성능 분석: 포물 반사경 vs. 프레넬 렌즈 (Performance Analysis on Solar Tracking Daylighting Systems Using Different Types of Solar Collectors: Parabolic Dish vs. Fresnel Lens)

  • 김영민;김원식;정해준;천원기
    • 한국태양에너지학회 논문집
    • /
    • 제37권1호
    • /
    • pp.39-45
    • /
    • 2017
  • This paper presents the effect of solar collectors on the performance of solar tracking daylighting systems. A series of measurements were made for two different types of solar collectors mounted on double axis solar trackers: Parabolic dish concentrator and Fresnel Lens. Indoor light levels were measured at different locations of an office space (longitude: 126.33 E, latitude 33.45 N) as photo sensors were placed on a task plane 80 cm above the floor. To accurately monitor the applicability of the systems, measurements were performed under clear and overcast sky conditions with the roll-screen (on the south window) in the down position. Comparing the illuminance data, the system with Fresnel lens outperformed that of parabolic dish concentrator. On clear days, the former delivered the light levels of 400~600 lux on the task plane whereas the latter recorded 100~200 lux. Depending on the amount of cloud cover, on overcast days, illuminance readings fluctuated to some extent.

정밀 전천공조도 데이터를 활용한 국내 주요도시 업무용 건물의 자연채광 활용성능 평가 (Evaluation of Daylighting Performance in Office Building with Detailed Global Illuminance Data of Selected Korean Cities)

  • 최수현;신상용;서동현
    • 한국태양에너지학회 논문집
    • /
    • 제36권6호
    • /
    • pp.37-46
    • /
    • 2016
  • In this study, long-term global illuminance data for 19 selected cities are calculated from modeled solar radiation data, AEER's TMY2. Perez model in Daysim daylight simulation tool is used for the solar radiation to illuminance conversion. And then, daylight availability in an unit office space is evaluated for the 19 cities. For this evaluation, various daylight performance indices are reviewed since static daylight performance index such as daylight factor (DF) and annual average global illuminance value is not suitable for actual performance evaluation in terms of visual comfort and light energy saving of a space. This study evaluated daylighting performance of prototypical office space module by introducing DA (daylight autonomy) and UDI (Useful Daylight Illuminance) index for major cities of Korea. Result shows that there is upto 18% of illuminance level difference with annual average global illuminance data, but if we consider useful daylight in a space the illuminance level difference among the cities are only within 5%. This means that for sustainable building design especially in daylight design, amount of annual global illuminance is not important factor even in cloudy cities. Daylight design and daylight harvesting system would return similar energy saving impact regardless of building location.

염료감응태양전지의 투과율에 따른 채광성능 및 현휘지수 분석을 통한 적정창면적비에 대한 연구 (A Study on the Optimal Window Floor Ratio Acording to Transmitance of Dye Sensitized Solar Cell(DSSC) by Analysis of Daylighting perfomance and Glare Index of Transmitance)

  • 오명환;심세라;이철성;진경일;윤종호
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.92-97
    • /
    • 2009
  • It is more necessary to consider the various factors for developmenting visible PV module of alternative window than traditional PV module. It must have sufficient performance which is Tvis, daylighting, daylight factor, glare index. so that more needs to consider suitable plan and total evaluated technology. Under the this background. For using commonly a combination BIPV module system and Daylinghting that can alternative architectural window, our goal on this study is drawing proper window area ratio as the window by analyzing lighting performance and glare index depending on transmittance of DSSC. On this study, we drew the result about window area ratio that can apply in the building when applying DSSC in the window. In situation that window is alternated as curtain wall in atrium that has big Widow area, if applying red 15.8% DSSC of low transmittance, it is expect to proper because it is suitable illumination standard and doesn't occur a discomfort glare. In case of office, we propose to apply red 33.2% or blue 35.2% DSSC of high transmittance for no affecting lighting load. we expect to contribute to select proper and effective window when applying the window in the building by drawing the window area ratio that can apply in thee building depending on transmittance of DSSC and offering the glare index data.

  • PDF

High-Performance Buildings 구현을 위한 신기술 연구 동향 및 에너지 절감 효과 평가 (Review of New Technologies' Energy Conservation Rate in High-Performance Buildings)

  • 김철호;양자강;이승언;유기형;김강수
    • KIEAE Journal
    • /
    • 제16권1호
    • /
    • pp.57-65
    • /
    • 2016
  • Purpose: The purpose of this study is to analyze the energy performance by applying new technologies for passive and active control. Method: We selected new technologies for passive and active control which are based on formal study by analyzing technology applied to the High-Performance Buildings in various countries. Also, we analyzed energy saving potential for each technologies by breakdown the result of the energy saving rates in detail. Result: For the wall and roof insulating methods, preceding studies showed that up to 21% energy could be saved by improving roof insulation and applying proper outside insulation compared to non-insulation. For the windows and glazing system, preceding studies showed that Low-E glazing system could save up to 11% energy compared to single glazing system. Studies about solar and daylighting controls revealed that effective daylighting dimming control could save 13% of energy compared to uncontrolled situation. Studies on DOAS (Dedicated Outdoor Air System) showed that about 23% energy could be saved compared to standard VAV system. Studies on the active chilled beam showed that about 25% energy could be saved compared to standard VAV system and studies of applying UFAD (Under Floor Air Distribution) could consume 31% less energy than applying overhead system.

자연채광 이용에 따른 조명에너지 평가용 노모그래프의 개발에 관한 연구 (Developement of Lighting Energy Estimation Nomograph by using Daylight)

  • 정유근;김정태
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1990년도 추계학술발표회논문집
    • /
    • pp.28-34
    • /
    • 1990
  • Lighting is one of the largest energy, integrated lighting system with daylight and artificial lighting has been suggested. In such system, perimeter zone can be illuminated by daylighting and the deep area of room by artificial lighting. So, the study is to develope estimation nomograph of lighting energy by turnning-off depth and lighting control systems during daytime. For the purpose, energy nomograph has been developed to apply to side-lit office guilding and the use and limitation of the nomograph has been discussed.

  • PDF

통합 채광시스템의 건물 냉난방 에너지 성능평가 (Building Energy Savings due to Incorporated Daylight-Glazing Systems)

  • 김정태;안현태;김곤
    • 조명전기설비학회논문지
    • /
    • 제19권6호
    • /
    • pp.1-8
    • /
    • 2005
  • 건물 내에 존재하는 자연광은 조명원으로 국한되지 않고 시각적, 심리적 자극을 통한 실내 환경의 질적 향상에 이르기까지 에너지절약 및 공간의 쾌적성에 큰 영향을 미친다. 유입되는 자연광량에 비례적으로 연동되는 건물에너지는 전기조명에너지를 절감시키고 난방 기간동안 일사열의 유입에 따른 난방에너지를 절감시킨다. 여름철에는 전기조명의 소등으로 인한 조명원의 발열량이 감소됨으로써 냉방부하의 감소에 이르기까지 포괄적인 영향을 미친다. 조명개발분야의 선진국에서는 에너지 절약형 광원의 대체와 아울러 자연채광과 통합된 최적 조명제어 기술의 운용만이 건물이 가지고 있는 에너지 절약의 잠재력을 현실화시킬 수 있다고 판단하고 있다. 따라서 본 연구는 일반적인 사무소 모델 공간의 에너지 절약형 인공조명을 대상으로 자연광 유입에 따른 연동적 조명제어 기법을 적용하는 경우를 대상으로, 인공조명의 소등량에 따른 조명에너지의 절감량과 이에 수반되는 냉방에너지의 점감량 및 일사열 취즉에 따른 겨울철 난방 부하 절감량을 분석함으로써 자연채광의 건물에너지에 대한 연간 기여도를 통합 분석하였다. 특히 자연채광의 성능은 실험을 통한 측정 데이터를 이용하고 에너지 해석 프로그램을 재구성하여 실질적인 절감량을 도출하도록 시도하였다.

실내 주광조도 간이 예측식을 활용한 담천공 시의 자연 채광 성능 평가 (Application of Simplified Daylight Prediction Method for Daylighting Performance Evaluation on Overcast Sky)

  • 윤갑천;윤수인;김성식;김강수
    • 한국태양에너지학회 논문집
    • /
    • 제34권5호
    • /
    • pp.1-9
    • /
    • 2014
  • Daylight is very useful to control the indoor environment, and can save energy in buildings. So it is necessary to evaluate the daylighting performance of buildings. We proposed a simplified equation that can be used in the early stages of design. And we verified the equation by using the measured illuminance data from the 1/5 scale model. We compared the calculated indoor illuminances and measured illuminance including Daylight Factors of scale model in order to verify the applicability of the simplified equation, and proved the analyzed values are acceptable. When we have a target value of the Daylight Factor, we just have to determine the window area, transmittance of the glazing system, and indoor surface reflectance, then can achieve it with this simplified equation.