• Title/Summary/Keyword: Data leak

Search Result 259, Processing Time 0.029 seconds

System of gas sensor for conbinating wire and wireless using Internet of Things (IOT기술을 이용한 유무선 통합 가스검출 시스템 구현)

  • Bang, Yong-Ki;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.4
    • /
    • pp.297-304
    • /
    • 2015
  • This study concerns the integrated gas sensor system of wire and wireless communication by using IoT(Internet of Things) technology. First, communication part is that it delivers the detection information, which transferred by wire or wireless communication and required control procedure based on a wireless module that receives the gas leakage information from wired or wireless detector, to administrator or user's terminal. Second, receiver part is that it shows the location and information, which received from the wired detector formed by a detecting sensor's node as linking with the communication part, and transfers these to the communication part. Third, wireless detector formed as a communication module of a detecting sensor node is that it detects gas leakage and transfers the information through wireless as a packet.Fourth, wired detector communicated with the receiver part and formed as a communication module of a detecting sensor node is that it detects gas leakage, transfers and shows the information as a packet. Fifth, administrator's terminal is that it receives gas leakage information by the communication part, transfers the signal by remote-control, and shut off a gas valve as responding the information. Sixth, database is that it is connected with the communication part; it sets and stores the default values for detecting smoke, CO., and temperature; it transfers this information to the communication part or sends a gas detecting signal to user's terminal. Seventh, user's terminal is that it receives each location's default value which stored and set at the database; it manages emergency situation as shutting off a gas valve through remote control by corresponding each location's gas leakage information, which transferred from the detector to the communication part by wireless.It is possible to process a high quality data regarding flammable or toxic gas by transferring the data, which measured by a sensor module of detector, to the communication part through wire and wireless. And, it allows a user to find the location by a smart phone where gas leaks. Eventually, it minimizes human life or property loss by having stability on gas leakage as well as corresponding each location's information quickly.

Opelative Risk and Results of Reoporation for Heart Valve Prostheses (인공심장판막 재치환술에 대한 수술 위험 인자 및 결과)

  • 김철환;김경훈
    • Journal of Chest Surgery
    • /
    • v.30 no.10
    • /
    • pp.973-978
    • /
    • 1997
  • We reviewed data of 64 patients who underwent reoperation because of prosthetic valve malfunction from January 1991 to December 1995. The indications for reoperation were prosthetic valve failure(primary tissue failure: 53 patients, 82.8%), prosthetic valve thrombosis(6 patients, 9.4%), paravalvular leak(3 patients, 4.7%), prosthetic valve endocarditis(2 patients, 3.6%). Prosthetic valve failure developed most frequently in mitral portion(40 patients, 75%), prosthetic valve thrombosis also in mitral portion(4 patients, 67%), paravalvular leak significantly in aortic portio (3 patients, 100%). Explant period was longest in prosthetic valve failure(mean 107.4 $\pm$ 24.6 months), shortest in prosthetic valve endocarditis with prosthetic valve thrombosis(1 patient, 1 month). Mean explant period, defined as from first valve replacement operation to redo-valve replacement operatopn, was 109.2$\pm$ 10.7 months in mitral portion, 97.8$\pm$ 10.4 months in aortic portion, 109.5$\pm$ 10.4 months in total. Overall hospital mortality was 9.38%. The most common cause of death was the low cardiac output(4 patients), other causes were bleeding(1 patient), CNS injury(1 patient). Preoperative NYHA class IV(P=0.011), emergency operation(P=0.011), prosthetic valve endocarditis(P=0.001) were the independent risk factors, but age, sex, explant period, ACC time, double valve replacement, valve position, second reoperation did not appear to be significant risk factors. Mean follow up period was 28.8 $\pm$ 17.8 months. Actuarial survival at 3 year was 92.0$\pm$6.2%, 2 year event-free survival w s 84.3$\pm$6.1%. We propose that patients undergoing reoperation because of prosthetic valve failure are carfully controlled and selected in regarding to above mentioned risk factors NYHA class IV, emergency operation, prosthetic valve endocarditis in preoperative state. About other risk factors possible, there is necessary of following study.

  • PDF

A Study on the Use of Scientific Investigation Equipment to Support Decision-making of the Resident Evacuation in the Event of a Chemical Accident (화학사고 발생에 따른 주민대피 의사결정 지원을 위한 과학조사장비 활용방안 연구)

  • Oh, Joo-Yeon;Lee, Tae Wook;Cho, Kuk
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.6_3
    • /
    • pp.1817-1826
    • /
    • 2022
  • After the hydrogen fluoride leak in Gumi in 2012, the government has been systemizing the disaster management system, such as responding to and managing chemical accidents. In particular, the Ministry of the Interior and Safety (MOIS) is in charge of evacuation of residents following chemical accidents based on the Framework Act on Management of Disaster and Safety. In this study, an application plan was presented to support and utilize the decision-making support for evacuation of residents after a chemical accident using the chemical accident investigation equipment of the National Disaster Management Research Institute (NDMI). In the equipment operation system for scientific information collection due to chemical accidents, the roles and purpose of use of long/short distance measurement equipment were presented according to regular and emergency situations. Using the data acquired through long/short distance measurement equipment, it can be used as basic data for resident evacuation decision-making by monitoring whether chemicals are detected in an emergency and managing data on detected substances by company in a regular situation. As a result of measuring chemical substances in order to verify on-site usability by equipment only for the regular operation system, it was confirmed that real-time detection of chemical substances is possible with long distance measuring equipment. In addition, it was confirmed that it was necessary to check the measurable distance and range of the equipment in the future. In the case of short distance measurement equipment, hydrocarbon-based substances were mainly detected, and it was confirmed that it was measured at a higher level in Ulsan-Mipo National Industrial Complex than in Onsan National Industrial Complex. It is expected that it can be used as basic data to support decision-making in the event of chemical accidents through continuous data construction in the future.

Dynamic Response of Plate Structure Subject to the Characteristics of Explosion Load Profiles - Part A: Analysis for the Explosion Load Characteristics and the Effect of Explosion Loading Rate on Structural Response - (폭발하중 이력 특성에 따른 판 구조물의 동적응답 평가 - Part A: 폭발하중 특징 및 재하속도의 영향 분석 -)

  • Kang, Ki-Yeob;Choi, Kwang-Ho;Ryu, YongHee;Choi, JaeWoong;Lee, Jae-Myung
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.28 no.2
    • /
    • pp.187-195
    • /
    • 2015
  • The gas explosions in offshore installations are known to be very severe according to its geometry and environmental conditions such as leak locations and wind directions, and a dynamic response of structures due to blast loads depends on the load profile. Therefore, a parametric study has to be conducted to investigate the effects of the dynamic response of structural members subjected to various types of load shapes. To do so, a series of CFD analyses was performed using a full-scale FPSO topside model including detail parts of pipes and equipments, and the time history data of the blast loads at monitor points and panels were obtained by the analyses. In this paper, we focus on a structural dynamic response subjected to blast loads changing the magnitude of positive/negative phase pressure and time duration. From the results of linear/nonlinear transient analyses using single degree of freedom(SDOF) and multi-degree-of freedom(MDOF) systems, it was observed that dynamic responses of structures were significantly influenced by the magnitude of positive and negative phase pressures and negative time duration.

The Comparative Quantitative Risk Assessment of LNG Tank Designs for the Safety Improvement of Above Ground Membrane Tank (지상식 멤브레인 LNG저장탱크 안전성 향상을 위한 설계형식별 정량적 위험성 비교 평가)

  • Lee S.R.;Kwon B.G.;Lee S.H.
    • Journal of the Korean Institute of Gas
    • /
    • v.9 no.4 s.29
    • /
    • pp.57-61
    • /
    • 2005
  • The objective of paper is to carry out a comparative Quantitative Risk Assessment (QRA) of two KOGAS tank designs using a fault tree methodology, a standard 'Full Containment' tank and a 'Membrane' tank. For the membrane tank, both the initial KOGAS design and 4 modified KOGAS designs have been assessed, giving six separate cases. In this paper, the frequencies of releases are quantified using a fault tree approach. For clarity in the analysis, and to ensure consistency, all cases have been quantified using the same fault tree. Logic within the fault tree is used to select each of the cases. Full quantification of risks is often difficult, owing to a lack of relevant failure data, but the aim of this study has been to be as quantitative as possible, with full transparency of failure information. The most significant general cause of external LNG leaks is predicted to be a seismic event, which has been quantified nominally. 4modified KOGAS desiens to Prevent damage of bottom membrane panels that was shown in preparatory estimation could quantitively confirm safety improvement. According to result, the predicted frequencies of an external LNG leak for the full containment and modified membrane tanks are very similar, failures due to dropped pumps are predicted to be significantly greater for the membrane tank with thickened plate than for the full containment tank.

  • PDF

Study on the Damage Pattern Analysis of a 3 Phase 22.9/3.3kV Oil Immersed Transformer and Judgment of the Cause of Its Ignition (3상 22.9/3.3kV 유입변압기의 소손패턴 해석 및 발화원인 판정에 관한 연구)

  • Choi, Chung-Seog
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.6
    • /
    • pp.1274-1279
    • /
    • 2011
  • The purpose of this paper is to present the manufacturing defect and damage pattern of a 3 phase 22.9/3.3kV oil immersed transformer, as well as to present an objective basis for the prevention of a similar accident and to secure data for the settlement of PL related disputes. It was found that in order to prevent the occurrence of accidents to transformers, insulating oil analysis, thermal image measurement, and corona discharge diagnosis, etc., were performed by establishing relevant regulation. The result of analysis performed on the external appearance of a transformer to which an accident occurred, the internal insulation resistance and protection system, etc., showed that most of the analysis items were judged to be acceptable. However, it was found that the insulation characteristics between the primary winding and the enclosure, those between the ground and the secondary winding, and those between the primary and secondary windings were inappropriate due to an insulating oil leak caused by damage to the pressure relief valve. From the analysis of the acidity values measured over the past 5 years, it is thought that an increase in carbon dioxide (CO2) caused an increase in the temperature inside the transformer and the increase in the ethylene gas increased the possibility of ignition. Even though 17 years have passed since the transformer was installed, it was found that the system's design, manufacture, maintenance and management have been performed well and the insulating paper was in good condition, and that there was no trace of public access or vandalism. However, in the case of transformers to which accidents have occurred, a melted area between the upper and the intermediate bobbins of the W-phase secondary winding as well as between its intermediate and lower bobbins. It can be seen that a V-pattern was formed at the carbonized area of the transformer and that the depth of the carbonization is deeper at the upper side than the lower side. In addition, it was found that physical bending and deformation occurred inside the secondary winding due to non-uniform pressure while performing transformer winding work. Therefore, since it is obvious that the accident occurred due to a manufacturing defect (winding work defect), it is thought that the manufacturer of the transformer is responsible for the accident and that it is lawful for the manufacture to investigate and prove the concrete cause of the accident according to the Product Liability Law (PLL).

A Study on Spam Document Classification Method using Characteristics of Keyword Repetition (단어 반복 특징을 이용한 스팸 문서 분류 방법에 관한 연구)

  • Lee, Seong-Jin;Baik, Jong-Bum;Han, Chung-Seok;Lee, Soo-Won
    • The KIPS Transactions:PartB
    • /
    • v.18B no.5
    • /
    • pp.315-324
    • /
    • 2011
  • In Web environment, a flood of spam causes serious social problems such as personal information leak, monetary loss from fishing and distribution of harmful contents. Moreover, types and techniques of spam distribution which must be controlled are varying as days go by. The learning based spam classification method using Bag-of-Words model is the most widely used method until now. However, this method is vulnerable to anti-spam avoidance techniques, which recent spams commonly have, because it classifies spam documents utilizing only keyword occurrence information from classification model training process. In this paper, we propose a spam document detection method using a characteristic of repeating words occurring in spam documents as a solution of anti-spam avoidance techniques. Recently, most spam documents have a trend of repeating key phrases that are designed to spread, and this trend can be used as a measure in classifying spam documents. In this paper, we define six variables, which represent a characteristic of word repetition, and use those variables as a feature set for constructing a classification model. The effectiveness of proposed method is evaluated by an experiment with blog posts and E-mail data. The result of experiment shows that the proposed method outperforms other approaches.

A Study on the Threats of Wiretapping and Effective Security Management Strategies (도청보안의 취약성 및 개선방안에 관한 연구)

  • Lee, Young Ho;Choi, Kyung Cheol;Woo, Sang Yeob
    • Korean Security Journal
    • /
    • no.62
    • /
    • pp.347-367
    • /
    • 2020
  • Rapid advancement of technology in today's society has allowed for easy access and use of data, promoting the process of informationization. Along with the merits of such development, unintended consequences of security risks involving wiretapping have been increasing as well. The security threats posed by wiretapping technology must be addressed by every organization and individual, as it could be used to leak confidential information about the nation's security, military and diplomatic strategies, industrial technologies, and personal information. Despite increasing threats stemming from the surrounding nations using advanced wiretapping technology, there is a lack of awareness at the government level, and the existing security measures for detecting and counteracting the wiretapping equipment are ineffective. In this research, the authors offered technical suggestions for improving the security strategies against the threats of wiretapping and information leakage by conducting a content analysis. The authors suggested the units of an agency be assigned a security grade based on its importance, and that adequate security equipment should be operated according to the grade. For instance, around-the-clock surveillance is recommended for grade-1 facilities, and portable wiretapping equipment detectors should be used to protect conference rooms and other key sites.

Novel Endoscopic Stent for Anastomotic Leaks after Total Gastrectomy Using an Anchoring Thread and Fully Covering Thick Membrane: Prevention of Embedding and Migration

  • Jung, Gum Mo;Lee, Seung Hyun;Myung, Dae Seong;Lee, Wan Sik;Joo, Young Eun;Jung, Mi Ran;Ryu, Seong Yeob;Park, Young Kyu;Cho, Sung Bum
    • Journal of Gastric Cancer
    • /
    • v.18 no.1
    • /
    • pp.37-47
    • /
    • 2018
  • Purpose: The endoscopic management of a fully covered self-expandable metal stent (SEMS) has been suggested for the primary treatment of patients with anastomotic leaks after total gastrectomy. Embedded stents due to tissue ingrowth and migration are the main obstacles in endoscopic stent management. Materials and Methods: The effectiveness and safety of endoscopic management were evaluated for anastomotic leaks when using a benign fully covered SEMS with an anchoring thread and thick silicone covering the membrane to prevent stent embedding and migration. We retrospectively reviewed the data of 14 consecutive patients with gastric cancer and anastomotic leaks after total gastrectomy treated from January 2009 to December 2016. Results: The technical success rate of endoscopic stent replacement was 100%, and the rate of complete leaks closure was 85.7% (n=12). The mean size of leaks was 13.1 mm (range, 3-30 mm). The time interval from operation to stent replacement was 10.7 days (range, 3-35 days) and the interval from stent replacement to extraction was 32.3 days (range, 18-49 days). The complication rate was 14.1%, and included a single jejunal ulcer and delayed stricture at the site of leakage. No embedded stent or migration occurred. Two patients died due to progression of pneumonia and septic shock 2 weeks after stent replacement. Conclusions: A benign fully covered SEMS with an anchoring thread and thick membrane is an effective and safe stent in patients with anastomotic leaks after total gastrectomy. The novelty of this stent is that it provides complete prevention of stent migration and embedding, compared with conventional fully covered SEMS.

Outcomes Based on Risk Assessment of Anastomotic Leakage after Rectal Cancer Surgery

  • Gong, Jian-Ping;Yang, Liu;Huang, Xin-En;Sun, Bei-Cheng;Zhou, Jian-Nong;Yu, Dong-Sheng;Zhou, Xin;Li, Dong-Zheng;Guan, Xin;Wang, Dong-Feng
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.2
    • /
    • pp.707-712
    • /
    • 2014
  • Purpose: Anastomotic leakage (AL) is associated with high morbidity and mortality, high reoperation rates, and increased hospital length of stay. Here we investigated the risk factors for AL after anterior resection for rectal cancer with a double stapling technique. Patients and Methods: Data for 460 patients who underwent primary anterior resection with a double stapling technique for rectal carcinoma at a single institution from 2003 to 2007 were prospectively collected. All patients experienced a total mesorectal excision (TME) operation. Clinical AL was defined as the presence of leakage signs and confirmed by diagnostic work-up according to ICD-9 codes 997.4, 567.22 (abdominopelvic abscess), and 569.81 (fistula of the intestine). Univariate and logistic regression analyses of 20 variables were undertaken to determine risk factors for AL. Survival was analysed using the Cox regression method. Results: AL was noted in 35 (7.6%) of 460 patients with rectal cancer. :Median age of the patients was 65 (50-74) and 161 (35%) were male. The diagnosis of AL was made between the 6th and 12th postoperative day (POD; mean 8th POD). After univariate and multivariate analysis, age (p=0.004), gender (p=0.007), tumor site (p<0.001), preoperative body mass index (EMI) (p<0.001), the reduction of TSGF on 5th POD less than 10U/ml (p=0.044) and the pH value of pelvic dranage less than or equal to 6.978 on 3rd POD (p<0.001) were selected as 6 independent risk factors for AL. It was shown that significant differences in survival of the patients were AL-related (p<0.001), high ASA score related (p=0.036), high-level EMI related (p=0.007) and advanced TNM stage related