• Title/Summary/Keyword: Data collector

Search Result 193, Processing Time 0.026 seconds

The Analysis of Optimum Design Parameters for a Solar Space Heating System through Computer Simulation (시뮬레이션에 의한 태양열 난방의 최적설계에 관한 연구)

  • Seoh, Jeong-Il;Lee, Young-Soo
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.14 no.3
    • /
    • pp.175-186
    • /
    • 1985
  • This paper presents a method for estimating the useful output of solar space heating system and estimates their performance with variance of collector size, storage volume, collector tilt and other factors . The analysis is performed by the computer simulation and by 'running' conceptual systems against solar intensities and ambient temperature for a model year stored in a computer. System performance is analyzed on monthly and yearly basis respectively and at the same time, the economics of various systems are evaluated . And also, this paper shows how an optimized design can be selected for any locality for which solar data, economic parameters and system performance are provided. It is shown that storage volume of 75 liter per $m^2$ of solar collector lead to the best design.

  • PDF

A Study on the Optimal Water Flow Rate of the Solar Heating System (태양열 난방시스템의 최적 유량에 관한 연구)

  • Seong, Kwan-Jae;Kim, Hyo-Kyung
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.12 no.1
    • /
    • pp.2-11
    • /
    • 1983
  • The solar energy retention rate of a flat plate collector can be increased by increasing water flow rate through the collector which also increases the pumping energy incurred in obtaining that solar energy. The problem of optimal flow rate is formulated to fit within the framework of pontryagin's maximum principle and with a few simplifying assumptions, an optimal solution that can be easily implemented is obtaincd, The optimal solution is used in the simulation of a solar heating system using actual climatological data and the results are compared with that of on-off control. The result that not only the object function but, In some cases, also the solar energy retention rate the collector is increased. In is also found that the optimal control gets more advantageous as the solar insolation level gets lower, and also as tile cost of auxiliary heating fuel gets higher.

  • PDF

A Study on the liquid Type Solar Heating System (액체식 태양열난방계통에 관한 연구)

  • Nam, Pyong-Woo
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.8 no.4
    • /
    • pp.221-236
    • /
    • 1979
  • The three years Performance of a liquid type solar heating system has been determined for a system which has been determined for a system which has been operating continuously since 1976 in Seoul with no serious maintenance. A flat plate collector is used to transform incident solar radiation into thermal energy. This energy is stored if the form of sensible energy and used as needed to supply the space heating loads. An electric auxiliary heaters are provided to supply energy for space heating load when the energy in the storage tank is depleted. The ratio of useful collected solar heat divided by the total solar radiation on the collector was obtained about 84 per cent. It is also obtained the relation between ratio of solar collector area to the heating area and the ratio of useful collected solar energy to the heating load for the useful design data. A comparison between the measured and simulated results with the solar space heating system is described. Hour by hour simulation is made on unsteady state basis using the system parameters and meteorological data at the experiment site. The result of comparison turned out satisfactory for the solar heating system, though the simulation was formed somewhat higher than by experimental.

  • PDF

A Study on the Setting Angle for the Flat-Plate Solar Collector' using Typical Meteorological Year Weather Data (평균년 표준기상데이터를 이용한 평판형 태양열 집열기 설치각 산정에 관한 연구)

  • 최정민
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.12
    • /
    • pp.1084-1091
    • /
    • 2002
  • In general, flat-plate solar collectors are generally fixed in place at some angles. The most common method is to orient solar collectors toward the true south, where variations up to 15 degrees east or west are acceptable and the tiIt angle of the collectors is calculated from latitude and different heating applications. However, the best angle of flat-plate collectors depends upon whether the dominant load occurs in the winter, summer, or evenly all year. Moreover, this setting angle must consider the average insolation characteristics of the region exactly. In this study, the setting angle of flat-plate solar collectors is presented for Busan area by using domestic typical meteorological year weather data, so that the fixed flat-plate solar collectors must be set as quantitatively as possible.

Design of a Secure Payment Mechanism based on S/MIME (S/MIME을 적용한 안전한 지불 메커니즘 설계)

  • Chun, Cheul-Woo;Lee, Jong-Hu;Lee, Sang-Ho
    • Journal of KIISE:Information Networking
    • /
    • v.29 no.5
    • /
    • pp.482-494
    • /
    • 2002
  • In E-mail based accounting system, the remitter does not have need to find collector's account number. To transfer money to a collector's account, what remitter need is just a collector's E-mail address. But the current E-mail based accounting systems are built on SSL technology. Basically SSL provides some security services - confidentiality, user authentication and data integrity, but does not provide non-repudiation. So, in the current E-mail based accounting system, it is possible to deny transaction. And there is no receipt of transaction. In this paper, we design and implementation of a S/MIME applied Secure Payment Mechanism. In our system, every account information - account number, receiver name, amount of money, etc. - is included in a 'check' message. And this message is protected under the Secure Web-mail using S/MIME. In a view point of the convenience, users using our system do not have need to find collector's account number. And in a view point of the security, our system provides confidentiality, user authentication, data integrity and non-repudiation. Moreover our system provides a receipt.

Evaluation Study of a Double Blind Light Pipe Daylighting System Efficiency and an Illumination Energy Reduction (이중 블라인드 광파이프 주광 조명시스템 효율 및 조명에너지 절감량 평가 연구)

  • Kang, Eun-Chul;Yoo, Seong-Yeon;Lee, Euy-Joon
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.1
    • /
    • pp.89-95
    • /
    • 2013
  • A DBLP(Double blind light pipe) daylight system can be installed at a building exterior wall or roof to replace artificial light during the day time. This system was consisted of a double blind light collector, a mirror duct type light transformer and a prism light pipe distributor. The double blinds were used to track the sun's altitude and azimuth movements to collect the sunlight throughout the day. The sunlight collected by the light collector was reflected on the first mirror and the second mirror and sent to the light pipe through the light transformer. The transformer was designed to deliver the sunlight into the light pipe efficiently. The light distributor plays a role in diffusing the sunlight coming in through the light collector to be used for indoor lighting. In this paper, a DBLP system has been designed, installed and tested at a KIER daylighting twin test cell. The DBLP daylighting system was applied to the experimental test cell which has an indoor area of 2.0 m wide ${\times}$ 2.4 m height ${\times}$ 3.8 m length. The experiment was conducted from January 30 to February 27, 2012, under clear skies and partially cloudy skies. Data was collected from 10:00 am to 16:00 pm every 2 minute and the average was calculated for every 30 minute of the data collection to obtain the system efficiency. The results indicated that the DBLP system efficiency was evaluated as 11.67%. The DBLP system indoor illumination energy reduction was predicted as 0.822 kWh/day. This could replace 4 sets of a 32W fluorescent lamp operating 6.4 hours per a day.

Flow Analysis of Facade Integrated Solar Water Heater with Natural Circulation (파사드 일체형 자연순환 태양열온수기 유동해석)

  • Baek, Nam-Choon;Lee, Wang-Je;Lim, Hee-Won;Shin, U-Cheul
    • KIEAE Journal
    • /
    • v.16 no.6
    • /
    • pp.167-172
    • /
    • 2016
  • Purpose: The solar water heater with natural circulation has been used for several decades in the world as it is automatically operated without a pump and controller and is easy to maintain and repair. After the subsidy was offered from 2012, the solar water heater with natural circulation is becoming increasingly popular in Korea. Recently, the development of a wall-integrated solar water heater, which improves the applicability of buildings and prevents the overheating in the summer, is being developed. On the other hand, the design and performance evaluation data of solar water heaters are very inadequate, and analysis of heat and flow is required to develop a new type of solar water heater. Method: Therefore, in this study, we proposed a new simplified system analysis model that reflects heat and pressure loss from the test results of KS B ISO 9806-1 (Solar collector test method), assuming that the collector is a simple pipe system, the validity of which was verified through experiments. Result: As a result, first, the RMSE of the system circulation flow rate and the average temperature of the inlet and outlet of the collector according to the experimental results and the simulation are 0.05563 and 0.88530, respectively, which are very consistent. Secondly, the mass flow rate is increased linearly with the increase of the solar radiation, and the mass flow rate is 0.0104 ~ 0.0180kg/s in the range of $200{\sim}380W/m^2$ of solar irradiance. Compared with the test flow rate 0.0764kg / s of the test collector, it showed a level of less than 20%.

Determination of the Groundwater Yield of horizontal wells using an artificial neural network model incorporating riverside groundwater level data (배후지 지하수위를 고려한 인공신경망 기반의 수평정별 취수량 결정 기법)

  • Kim, Gyoo-Bum;Oh, Dong-Hwan
    • The Journal of Engineering Geology
    • /
    • v.28 no.4
    • /
    • pp.583-592
    • /
    • 2018
  • Recently, concern has arisen regarding the lowering of groundwater levels in the hinterland caused by the development of high-capacity radial collector wells in riverbank filtration areas. In this study, groundwater levels are estimated using Modflow software in relation to the water volume pumped by the radial collector well in Anseongcheon Stream. Using the water volume data, an artificial neural network (ANN) model is developed to determine the amount of water that can be withdrawn while minimizing the reduction of groundwater level. We estimate that increasing the pumping rate of the horizontal well HW-6, which is drilled parallel to the stream direction, is necessary to minimize the reduction of groundwater levels in wells OW-7 and OB-11. We also note that the number of input data and the classification of training and test data affect the results of the ANN model. This type of approach, which supplements ANN modeling with observed data, should contribute to the future groundwater management of hinterland areas.

The Development of a Computer Simulation Model for Solar Space Heating System Analysis (태양열 난방시스템 해석을 위한 전산시뮬레이션 모델의 개발)

  • Lee Y. S.;Seoh J. I.
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.16 no.1
    • /
    • pp.63-73
    • /
    • 1987
  • This research, through the analysis of existing programs, presents a simplified logical program which can show the thermal performance of a system, based only on hourly weather data and the system design data. This program is applicable for analyzing a system of direct heating or recirculation heating which may enhance the performance of an existing solar house. Using these system in the existing systems a little raise in performance. The model analysis of a $100\;m^2$ solar house in the seoul region shows that the following figures are the most efficient and suitable; 1. Installation an81e of collector: $45^{\circ}$ 2. Collector size: $34.56\;m^2$ 3. Capacity of main storage tank: $25\;m^3$

  • PDF

A Wireless ECG Measurement System based on the Zigbee USN (Zigbee USN 기반의 무선 ECG 측정 시스템)

  • Chang, Yun-Seok;Kim, Bo-Yeon
    • The KIPS Transactions:PartC
    • /
    • v.18C no.3
    • /
    • pp.195-198
    • /
    • 2011
  • Recent expansion of the ubiquitous environment and improvement of the USN give lots of U-healthcare systems. In this paper, we design and implement a wireless ECG measurement system that can send ECG signals among the sensors and collector. It can also give almost the same precision as a hospital ECG system with mobility. The most important fact of the mobile ECG system is the signal data connectivity among the sensors and device such as signal cables or wires. we can eliminate the signal cable through the Zigbee sender and collector via implementing Zigbee-SD communication system that can receive the ECG signal data. We also implement ECG app software on the smart phone that can analyze and show the data results directly. It can give lots of mobility and usability under ubiquitous environment and would be a very efficient wireless ECG system for U-healthcare service.