• Title/Summary/Keyword: Data acquisition and processing system

Search Result 432, Processing Time 0.031 seconds

A study of bad data processing application in the substation (변전소내 Bad Data Processing어 관한 연구)

  • Jin B.G.;Choi I.S.;Hyun S.H.;Lee S.J.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.406-408
    • /
    • 2004
  • It is very necessary to adopt bad data processing in order to maintain the security and the reliability of data acquisition and management in the substation. This paper presents a bad data processing method of per module unit by using rule based system. The propriety of this method has been verified by the case study

  • PDF

Biological Signal Measurements in SiMACS (SiMACS에서의 생체신호 수집)

  • Lim, J.J.;Choi, Y.S.;Kim, D.H.;Kim, E.J.;Lee, H.J.;Woo, E.J.;Park, S.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1994 no.05
    • /
    • pp.53-56
    • /
    • 1994
  • We have developed biological signal measurement modules and data acquisition and control card for a biological signal measurement, archiving, and communication system (SiMACS). Biological signals included in this system are ECG, EEG, EMG, invasive blood pressure, respiration, and temperature. Parameters of each module can be controlled by PC-base IDPU (intelligent data processing unit) through a data acquisition and control card. The data acquisition and control card can collect up to 16 channels of biological signals with sampling rate of $50\;{\sim}\;2,000Hz$ and 12-bit resolution. All measurement moduls and data acquisition functions are controlled by microcontroller which receives commands from PC. All data transfers among PC, microcontroller, and ADC are done through a shared RAM access by polling method for real rime operation.

  • PDF

Implementation of ICT-based Real-time Hydrological Data Acquisition and Processing System for Scientific Water Management (과학적 물관리를 위한 ICT기반 실시간 수문정보시스템 구현)

  • Jang, Sung-Won;Jeong, Chang-wook;Jo, Kyoung-Hoon;Shin, Ji-su
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.05a
    • /
    • pp.303-305
    • /
    • 2022
  • In Korea, due to the geographical and hydrological characteristics of the country, the water cycle has a large variation throughout the year. Therefore, in order to quickly identify and prepare for hydrological phenomena such as floods and droughts, the need for scientific water management incorporating the latest ICT technologies is growing. Accordingly, K-water operates a real-time Hydrological Data Acquisition and Processing System (HDAPS) that can check the situation of the site more intuitionally by linking the hydrological data collected in real time through satellite, GIS, and CCTV. and prepared for flood and drought. In this paper, we will introduce K-water's real-time hydrological information system and consider its application to protect people's lives and property.

  • PDF

An integrated structural health monitoring system for the Xijiang high-speed railway arch bridge

  • He, Xu-hui;Shi, Kang;Wu, Teng
    • Smart Structures and Systems
    • /
    • v.21 no.5
    • /
    • pp.611-621
    • /
    • 2018
  • Compared with the highway bridges, the relatively higher requirement on the safety and comfort of vehicle makes the high-speed railway (HSR) bridges need to present enhanced dynamic performance. To this end, installing a health monitor system (HMS) on selected key HSR bridges has been widely applied. Typically, the HSR takes fully enclosed operation model and its skylight time is very short, which means that it is not easy to operate the acquisition devices and download data on site. However, current HMS usually involves manual operations, which makes it inconvenient to be used for the HSR. Hence, a HMS named DASP-MTS (Data Acquisition and Signal Processing - Monitoring Test System) that integrates the internet, cloud computing (CC) and virtual instrument (VI) techniques, is developed in this study. DASP-MTS can realize data acquisition and transmission automatically. Furthermore, the acquired data can be timely shared with experts from various locations to deal with the unexpected events. The system works in a Browser/Server frame so that users at any places can obtain real-time data and assess the health situation without installing any software. The developed integrated HMS has been applied to the Xijiang high-speed railway arch bridge. Preliminary analysis results are presented to demonstrate the efficacy of the DASP-MTS as applied to the HSR bridges. This study will provide a reference to design the HMS for other similar bridges.

Quality Monitoring Method Analysis for GNSS Ground Station Monitoring and Control Subsystem (위성항법 지상국 감시제어시스템 품질 감시 기법 분석)

  • Jeong, Seong-Kyun;Lee, Sang-Uk
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.18 no.1
    • /
    • pp.11-18
    • /
    • 2010
  • GNSS(Global Navigation Satellite System) Ground Station performs GNSS signal acquisition and processing. This system generates error correction information and distributes them to GNSS users. GNSS Ground Station consists of sensor station which contains receiver and meteorological sensor, monitoring and control subsystem which monitors and controls sensor station, control center which generates error correction information, and uplink station which transmits correction information to navigation satellites. Monitoring and control subsystem acquires and processes navigation data from sensor station. The processed data is transmitted to GNSS control center. Monitoring and control subsystem consists of data acquisition module, data formatting and archiving module, data error correction module, navigation determination module, independent quality monitoring module, and system maintenance and management module. The independent quality monitoring module inspects navigation signal, data, and measurement. This paper introduces independent quality monitoring and performs the analysis using measurement data.

Feasibility Study of Data Acquisition System based on Oscilloscope for Radiation Detector (방사선 검출기용 데이터획득장치로서의 오실로스코프 활용 가능성 평가)

  • Yang, Jingyu;Kang, Jihoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.12
    • /
    • pp.1804-1809
    • /
    • 2017
  • A data acquisition (DAQ) system based on oscilloscope was developed and evaluated for radiation detector. The dedicated LabVIEW program that perform the oscilloscope control and the data process was developed. Triggered events for each analog channel were acquired and the output signals were subsequently digitized and recorded for offline processing. Radiation pulse generation circuit was developed to evaluate the intrinsic characteristics of DAQ system. Energy linearity and energy resolution performances were assessed by voltage-peak channels and FWHM obtained from Gaussian fit, respectively. Radiation detector consists of LYSO and GAPD array. The 16 output signals were multiplexed by the RCD networks, and they were fed into the custom-made preamplifiers. Voltage-peak channels was linearly changed as a function of input voltage and the estimated coefficient of determination ($R^2$) was 0.999. No considerable changes in voltage resolution were observed. All 16 crystals were clearly identifiable on the resulting flood image and the mean energy resolution was ~15.1%. This study demonstrated that it is feasible to develop the DAQ system based on oscilloscope and LabVIEW program for radiation detector and the proposed approach offers opportunities to build simple DAQ system in various radiation measurement field.

Application of a wireless pressure sensing system to coastal wind monitoring

  • Pinelli, J.P.;Subramanian, C.S.;Lapilli, C.;Buist, L.
    • Wind and Structures
    • /
    • v.8 no.3
    • /
    • pp.179-196
    • /
    • 2005
  • This paper describes the application of a wireless data acquisition system to monitor wind pressures and velocities with absolute pressure sensors and an anemometer. The system was developed for future deployment, as part of a research effort currently underway to instrument coastal homes in Florida to monitor roof wind pressures during hurricanes. The proposed wireless system will replace the current system that involves a large amount of hardwired connections from the sensors to the data processing unit that requires labor intensive wiring and preparation of the home. The paper describes comparison studies and field tests to assess the performance of the system. The new system offers the advantages of light hardware, ease of installation, capacity for 48 hours of continuous data acquisition, good frequency and amplitude responses, and a relatively simple maintenance. However, the tests also show that the shape of the shell that has been previously used to protect the sensors might interfere with the proper measurement of the pressures.

Development of a distributed high-speed data acquisition and monitoring system based on a special data packet format for HUST RF negative ion source

  • Li, Dong;Yin, Ling;Wang, Sai;Zuo, Chen;Chen, Dezhi
    • Nuclear Engineering and Technology
    • /
    • v.54 no.10
    • /
    • pp.3587-3594
    • /
    • 2022
  • A distributed high-speed data acquisition and monitoring system for the RF negative ion source at Huazhong University of Science and Technology (HUST) is developed, which consists of data acquisition, data forwarding and data processing. Firstly, the data acquisition modules sample physical signals at high speed and upload the sampling data with corresponding absolute-time labels over UDP, which builds the time correlation among different signals. And a special data packet format is proposed for the data upload, which is convenient for packing or parsing a fixed-length packet, especially when the span of the time labels in a packet crosses an absolute second. The data forwarding modules then receive the UDP messages and distribute their data packets to the real-time display module and the data storage modules by PUB/SUB-pattern message queue of ZeroMQ. As for the data storage, a scheme combining the file server and MySQL database is adopted to increase the storage rate and facilitate the data query. The test results show that the loss rate of the data packets is within the range of 0-5% and the storage rate is higher than 20 Mbps, both acceptable for the HUST RF negative ion source.

Hardware Implementation of High-Speed Active Vibration Control System Based on DSP320C6713 Processor

  • Kim, Dong-Chan;Choi, Hyeung-Sik;Her, Jae-Gwan;You, Sam-Sang
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.3
    • /
    • pp.437-445
    • /
    • 2008
  • This paper deals with the experimental assessment of the vibration suppression of the smart structures. First. we have presented a new high-speed active control system using the DSP320C6713 microprocessor. A peripheral system developed is composed of a data acquisition system, N/D and D/A converters, piezoelectric (PZT) actuator/sensors, and drivers for fast data processing. Next, we have tested the processing time of the peripheral devices, and provided the corresponding test results. Since fast data processing is very important in the active vibration control of the structures, we have focused on achieving the fast loop times of the control system. Finally, numerous experiments were carried out on the aluminum plate to validate the superior performance of the vibration control system at different control loop times.

Real-time 256-channel 12-bit 1ks/s Hardware for MCG Signal Acquisition (심자도 신호획득을 위한 실시간 256-채널 12-bit 1ks/s 하드웨어)

  • Yoo, Jae-Tack
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.54 no.11
    • /
    • pp.643-649
    • /
    • 2005
  • A heart diagnosis system adopts Superconducting Quantum Interface Device(SQUD) sensors for precise MCG(MagnetoCardioGram) signal acquisitions. Such system needs to deal with hundreds of sensors, requiring fast signal sampling md precise analog-to-digital conversions(ADC). Our development of hardware board, processing 64-channel 12-bit in 1 ks/s speed, is built by using 8-channel ADC chips, 8-bit microprocessors, SPI interfaces, and specially designed parallel data transfers between microprocessors to meet the 1ks/s, i.e. 1 mili-second sampling interval. We extend the design into 256-channel hardware and analyze the speed .using the measured data from the 64-channel hardware. Since our design exploits full parallel processing, Assembly level coding, and NOP(No Operation) instruction for timing control, the design provides expandability and lowest system timing margin. Our result concludes that the data collection with 256-channel analog input signals can be done in 201.5us time-interval which is much shorter than the required 1 mili-second period.