• Title/Summary/Keyword: Data Use

Search Result 28,725, Processing Time 0.069 seconds

Study on the diagnostic utility of serum levels of insulin-like growth Factor-I and insulin-like growth factor binding protein-3 in growth hormone deficiency (성장호르몬 결핍증 진단에 있어서 혈중 insulin-like growth factor-I 및 insulin-like growth factor binding protein-3 농도의 진단적 유용성에 대한 연구)

  • Ji, Geun Ha;Lee, Jeong Nyeo;Chung, Woo Yeong
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.12
    • /
    • pp.1329-1335
    • /
    • 2008
  • Purpose : This study aimed to determine the best cutoff line for insulin-like growth factor (IGF)-I and insulin-like growth factor binding protein (IGFBP)-3 to discriminate between growth hormone deficiency (GHD) patients and the control group. Methods : Two hundred thirty subjects with normal controls (129 boys and 101 girls, aged 7-15 years), 14 patients with complete GHD (12 boys and 2 girls), and 17 patients with partial GHD (9 boys and 8 girls) were studied. IGF-I serum concentrations were measured by radioimmunoassay (RI), and IGFBP-3 concentrations were measured by immunoradiometric assay (IRMA). Results : The receiver operating characteristic (ROC) plot analysis showed that the best IGF-I and IGFBP-3 cutoff line was at -1 standard deviation (SD). By comparing IGF-I serum levels of GHD children within 1 SD of normal control, we determined the sensitivity (S) (87.5-100%) and specificity (Sp) (80-84.6%) according to the age group. For IGFBP-3, we determined the following values: S (58.7-85.7%) and Sp (79.2-85.5%). Eleven of 14 patients with complete GHD (78.5%) and 16 of 17 patients with partial GHD (94.1%) had IGF-I concentrations equal to or below -1 SD of the control group mean. Ten of 12 complete GHD children (83.3%) and 13 of 17 partial GHD children (76.5%) had IGFBP-3 concentrations equal or below -1 SD of the control group mean. Conclusion : We conclude that the measurement of IGF-I and IGFBP-3 concentrations might provide essential supplementary data in the diagnostic evaluation of patients with GHD. Our results support the need to use cutoff lines based on below -1 SD of the control.

Fabrication of Backscatter Electron Cones for Radiation Therapy (산란전자선을 이용한 강내측방조사기구의 제작과 특성)

  • Chu, Sung-Sil;Suh, Chang-Ok;Kim, Gwi-Eon
    • Radiation Oncology Journal
    • /
    • v.19 no.1
    • /
    • pp.74-80
    • /
    • 2001
  • Purpose : Irradiation cones by using backscatter electrons are made for the treatment of superficial small lesions of skin, oral cavity, and rectum where a significant dose gradient and maximum surface dose is desired. Methods and Materials : Backscatter electrons are produced from the primary electron beams from the linear accelerators. The design consists of a cylindrical cone that has a thick circular plate of high atomic number medium (Pb or Cu) attached to the distal end, and the plate can be adjusted the reflected angle. Primary electrons strike the metal plate perpendicularly and produce backscatter electrons that reflect through the lateral hole for treatment. Using film and a parallel plate ion chamber, backscatter electron dose characteristics are measured. Results : The depth dose characteristic of the backscatter electron is very similar to that of the hard x-ray beam that is commonly used for the intracavitary and superficial lesions. The basckscatter electron energy is nearly constant and effectively about 1.5 MeV from the clinical megavoltage beams. The backscatter electron dose rate of $35\~85\;cGy/min$ could be achieved from modern accelerators without any modification. and the depth in water of $50\%$ depth dose from backscatter electron located at 6mm for $45^{\circ}$ angled lead scatter. The beam flatness is dependent on the slit size and the depth of treatment, but is satisfactory to treat small lesions. Conclusions : The measured data for backscatter electron energy, depth dose flatness dose rate and absolute dose indicates that the backscatter electrons are suitable for clinical use.

  • PDF

2010 Inter-laboratory Comparison Study on Nutrient Analysis in Seawater (2010년 국내 해수 중 영양염 분석 실험실간 상호비교실험 연구)

  • Moon, Cho-Rong;Rho, Taekeun;Kang, Dong-Jin;Kahng, Sung-Hyun;Cho, Sung Rok;Kim, Eun-Soo;Lee, Jung Moo;Park, Eun Ju;Shin, Jin-Sun
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.20 no.1
    • /
    • pp.63-70
    • /
    • 2015
  • An inter-laboratory comparison campaign on nutrient analysis in seawater was carried out in 2010. Sets of three sterilized seawater samples (Bottle 130, 131, 132) which have enough homogeneity and stability were distributed to 10 laboratories. Participants analyzed the nutrients in their own laboratories (nitrite, nitrate, phosphate, and silicate) at least 5 times and reported the results. Statistical treatments were applied to the results to assess the precision for each laboratory and the discrepancy among laboratories. Most laboratories show within 10% of precision in all nutrient results. Degrees of scattering described as discrepancy among laboratories and relative percent difference values were 4~63% and 0.04~2217%, respectively. The statistical analysis shows that the difference among the laboratories may due to the systematic error rather than random error. When the results were corrected by the results of bottle 130 as a reference material, the degrees of scattering and the relative percent difference were improved significantly. As a result, since most participants show satisfactory precision for nutrient analyses, a use of reference materials which have homogeneity and stability was strongly recommended to improve the comparability of nutrient data.

The Causative Organisms of Otitis Media Accompanying Otorrhea in Children and Their Antimicrobial Susceptibility (소아에서 이루를 동반한 중이염의 원인 및 항균제 감수성)

  • Jung, Do Seok;Kim, Heon Sang;Park, Chul Won;Oh, Sung Hee
    • Pediatric Infection and Vaccine
    • /
    • v.7 no.2
    • /
    • pp.233-239
    • /
    • 2000
  • Purpose : A great deal of youngsters suffer from otitis media, for which antimicrobials are frequently prescribed. Increased antimicrobial resistance forces physicians to judiciously use antimicrobial agents in treating patients with acute otitis media. There have however been few references with regard to otitis media in Korean children, and authors proceeded investigation to look for the causative agents of otitis media in Korean children and their antimicrobial susceptibility. Methods : The study included 65 patients younger than 15 years old who had been cared at the department of pediatrics and otolaryngology in Hanyang University Hospital from July 1994 to June 1999, and diagnosed of otitis media with otorrhea which contained microorganisms isolated in otorrhea culture. The medical records were reviewed for demographic data, isolated organisms and their antimicrobial susceptibility. Results : Among 65 patients, 37(57%) were boys and 28(43%) girls. Distribution of the patients was reciprocal to the age of the patients; 27 patients(41.5%) were younger than 1 year old, 24(36.9%) were 1 to 3 years old with the average of 2.9 years of age. Staphylococus aureus was isolated in 32 patients(49.2%), Streptococcus pneumoniae in 19 patients(29.2%) Haemophilus influenzae in 9 patients(13.8%), Streptococcus oralis in 3 patients(4.6%), Moraxella catarrhalis in 1 patient(1.5%). The isolated microorganisms were not different whether patients had cleft lip/palate or not. The antibiotic resistance rates of S. aureus were ${\geq}90%$ to erythromycin, imipenem, cephalothin, and clindamycin, 86.2% to oxacillin, 25% to chloramphenicol, 12.5% to trimethoprim/sulfamethoxazole(TMP/SMX), and 0% to vancomycin and teicoplanin. The antibiotic resistance rates of S. pneumoniae were 71.4% to penicillin and greater than 60% to erythromycin, tetracycline, TMP/SMX, 7.1% to chloramphenicol, and 0% to vancomycin and teicoplanin. The antibiotic resistance rates of H. influenzae were 55% to ampicillin and TMP/SMX, and 0% to chloramphenicol, ceftriaxone, aztreonam, imipenem and ciprofloxacin. Conclusion : With otorrhea culture, the causative organisms of otitis media appear to be S. aureus, S. pneumoniae and H. influenzae. The high antibiotic resistance rates of the isolated organisms should affect the choice of antibiotics in treating patients with otitis media. Prospective investigations utilizing tympanocentesis in microbiologic studies are needed.

  • PDF

Current Status and Future Prospect of Plant Disease Forecasting System in Korea (우리 나라 식물병 발생예찰의 현황과 전망)

  • Kim, Choong-Hoe
    • Research in Plant Disease
    • /
    • v.8 no.2
    • /
    • pp.84-91
    • /
    • 2002
  • Disease forecasting in Korea was first studied in the Department of Fundamental Research, in the Central Agricultural Technology Institute in Suwon in 1947, where the dispersal of air-borne conidia of blast and brown spot pathogens in rice was examined. Disease forecasting system in Korea is operated based on information obtained from 200 main forecasting plots scattered around country (rice 150, economic crops 50) and 1,403 supplementary observational plots (rice 1,050, others 353) maintained by Korean government. Total number of target crops and diseases in both forecasting plots amount to 30 crops and 104 diseases. Disease development in the forecasting plots is examined by two extension agents specialized in disease forecasting, working in the national Agricul-tural Technology Service Center(ATSC) founded in each city and prefecture. The data obtained by the extension agents are transferred to a central organization, Rural Development Administration (RDA) through an internet-web system for analysis in a nation-wide forecasting program, and forwarded far the Central Forecasting Council consisted of 12 members from administration, university, research institution, meteorology station, and mass media to discuss present situation of disease development and subsequent progress. The council issues a forecasting information message, as a result of analysis, that is announced in public via mass media to 245 agencies including ATSC, who informs to local administration, the related agencies and farmers for implementation of disease control activity. However, in future successful performance of plant disease forecasting system is thought to be securing of excellent extension agents specialized in disease forecasting, elevation of their forecasting ability through continuous trainings, and furnishing of prominent forecasting equipments. Researches in plant disease forecasting in Korea have been concentrated on rice blast, where much information is available, but are substan-tially limited in other diseases. Most of the forecasting researches failed to achieve the continuity of researches on specialized topic, ignoring steady improvement towards practical use. Since disease forecasting loses its value without practicality, more efforts are needed to improve the practicality of the forecasting method in both spatial and temporal aspects. Since significance of disease forecasting is directly related to economic profit, further fore-casting researches should be planned and propelled in relation to fungicide spray scheduling or decision-making of control activities.

Comparisons between the Two Dose Profiles Extracted from Leksell GammaPlan and Calculated by Variable Ellipsoid Modeling Technique (렉셀 감마플랜(LGP)에서 추출된 선량 분포와 가변 타원체 모형화기술(VEMT)에 의해 계산된 선량 분포 사이의 비교)

  • Hur, Beong Ik
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.1
    • /
    • pp.9-17
    • /
    • 2017
  • A high degree of precision and accuracy in Gamma Knife Radiosurgery(GKRS) is a fundamental requirement for therapeutical success. Elaborate radiation delivery and dose gradients with the steep fall-off of radiation are clinically applied thus necessitating a dedicated Quality Assurance(QA) program in order to guarantee dosimetric and geometric accuracy and reduce all the risk factors that can occur in GKRS. In this study, as a part of QA we verified the accuracy of single-shot dose profiles used in the algorithm of Gamma Knife Perfexion(PFX) treatment planning system employing Variable Ellipsoid Modeling Technique(VEMT). We evaluated the dose distributions of single-shots in a spherical ABC phantom with diameter 160 mm on Gamma Knife PFX. The single-shots were directed to the center of ABC phantom. Collimating configurations of 4, 8, and 16 mm sizes along x, y, and z axes were studied. Gamma Knife PFX treatment planning system being used in GKRS is called Leksell GammaPlan(LGP) ver 10.1.1. From the verification like this, the accuracy of GKRS will be doubled. Then the clinical application must be finally performed based on precision and accuracy of GKRS. Specifically the width at the 50% isodose level, that is, Full-Width-of-Half-Maximum(FWHM) was verified under such conditions that a patient's head is simulated as a sphere with diameter 160mm. All the data about dose profiles along x, y, and z axes predicted through VEMT were excellently consistent with dose profiles from LGP within specifications(${\leq}1mm$ at 50% isodose level) except for a little difference of FWHM and PENUMBRA(isodose level: 20%~80%) along z axis for 4 mm and 8mm collimating configurations. The maximum discrepancy of FWHM was less than 2.3% at all collimating configurations. The maximum discrepancy of PENUMBRA was given for the 8 mm collimator along z axis. The difference of FWHM and PENUMBRA in the dose distributions obtained with VEMT and LGP is too small to give the clinical significance in GKRS. The results of this study are considered as a reference for medical physicists involved in GKRS in the whole world. Therefore we can work to confirm the validity of dose distributions for all collimating configurations determined through the regular preventative maintenance program using the independent verification method VEMT for the results of LGP and clinically assure the perfect treatment for patients of GKRS. Thus the use of VEMT is expected that it will be a part of QA that can verify and operate the system safely.

The Effect of Herding Behavior and Perceived Usefulness on Intention to Purchase e-Learning Content: Comparison Analysis by Purchase Experience (무리행동과 지각된 유용성이 이러닝 컨텐츠 구매의도에 미치는 영향: 구매경험에 의한 비교분석)

  • Yoo, Chul-Woo;Kim, Yang-Jin;Moon, Jung-Hoon;Choe, Young-Chan
    • Asia pacific journal of information systems
    • /
    • v.18 no.4
    • /
    • pp.105-130
    • /
    • 2008
  • Consumers of e-learning market differ from those of other markets in that they are replaced in a specific time scale. For example, e-learning contents aimed at highschool senior students cannot be consumed by a specific consumer over the designated period of time. Hence e-learning service providers need to attract new groups of students every year. Due to lack of information on products designed for continuously emerging consumers, the consumers face difficulties in making rational decisions in a short time period. Increased uncertainty of product purchase leads customers to herding behaviors to obtain information of the product from others and imitate them. Taking into consideration of these features of e-learning market, this study will focus on the online herding behavior in purchasing e-learning contents. There is no definite concept for e-learning. However, it is being discussed in a wide range of perspectives from educational engineering to management to e-business etc. Based upon the existing studies, we identify two main view-points regarding e-learning. The first defines e-learning as a concept that includes existing terminologies, such as CBT (Computer Based Training), WBT (Web Based Training), and IBT (Internet Based Training). In this view, e-learning utilizes IT in order to support professors and a part of or entire education systems. In the second perspective, e-learning is defined as the usage of Internet technology to deliver diverse intelligence and achievement enhancing solutions. In other words, only the educations that are done through the Internet and network can be classified as e-learning. We take the second definition of e-learning for our working definition. The main goal of this study is to investigate what factors affect consumer intention to purchase e-learning contents and to identify the differential impact of the factors between consumers with purchase experience and those without the experience. To accomplish the goal of this study, it focuses on herding behavior and perceived usefulness as antecedents to behavioral intention. The proposed research model in the study extends the Technology Acceptance Model by adding herding behavior and usability to take into account the unique characteristics of e-learning content market and e-learning systems use, respectively. The current study also includes consumer experience with e-learning content purchase because the previous experience is believed to affect purchasing intention when consumers buy experience goods or services. Previous studies on e-learning did not consider the characteristics of e-learning contents market and the differential impact of consumer experience on the relationship between the antecedents and behavioral intention, which is the target of this study. This study employs a survey method to empirically test the proposed research model. A survey questionnaire was developed and distributed to 629 informants. 528 responses were collected, which consist of potential customer group (n = 133) and experienced customer group (n = 395). The data were analyzed using PLS method, a structural equation modeling method. Overall, both herding behavior and perceived usefulness influence consumer intention to purchase e-learning contents. In detail, in the case of potential customer group, herding behavior has stronger effect on purchase intention than does perceived usefulness. However, in the case of shopping-experienced customer group, perceived usefulness has stronger effect than does herding behavior. In sum, the results of the analysis show that with regard to purchasing experience, perceived usefulness and herding behavior had differential effects upon the purchase of e-learning contents. As a follow-up analysis, the interaction effects of the number of purchase transaction and herding behavior/perceived usefulness on purchase intention were investigated. The results show that there are no interaction effects. This study contributes to the literature in a couple of ways. From a theoretical perspective, this study examined and showed evidence that the characteristics of e-learning market such as continuous renewal of consumers and thus high uncertainty and individual experiences are important factors to be considered when the purchase intention of e-learning content is studied. This study can be used as a basis for future studies on e-learning success. From a practical perspective, this study provides several important implications on what types of marketing strategies e-learning companies need to build. The bottom lines of these strategies include target group attraction, word-of-mouth management, enhancement of web site usability quality, etc. The limitations of this study are also discussed for future studies.

A STUDY ON NEWCASTLE DISEASE VACCINATION: The Immunological Response to Inactivated and Attenuated Virus Vaccines (Newcastle병(病)의 예방접종(豫防接種)에 관한 연구(硏究); 사독(死毒)백신 및 감독(減毒)된 생독(生毒)백신에 대한 면역학적(免疫學的) 반응(反應))

  • Chung, Gill Taik
    • Korean Journal of Veterinary Research
    • /
    • v.2 no.1
    • /
    • pp.27-36
    • /
    • 1962
  • Immune response to two methods of Newcastle disease virus vaccine, one inactivated and the other attenuated was observed and the data presented. (1) Administration of inactivated virus vaccine in an amount of 1.0 ml. by intramuscular route gave an appreciable immunity to Newcastle disease for a period of at least three-and-half months. (2) The chickens given attenuated virus vaccine in the drinking water produced satisfactory immunity as manifested by the fact that immunized birds showed resistance when challenged 105 days after the vaccination and maintained high degree of HI titer for a period of 75 days. (3) Vaccination with the attenuated virus vaccine in drinking water is very simple and time saving in procedure, although the duration of immunity seems to be slightly shorter than that proced by inactivated virus vaccine. The author wishes to express his appreciation, to Drs. Kyu Myung Lee, Chang Koo Lee, and Ryong Sook Kee of their suggestions and help. The author is also indebted to Dr. Chang Hi Lee, Director of Anyang Veterinary Laboratory, who allowed the use of the facilities of the laboratory, whitout which this experiment could not have been undertaken.

  • PDF

Correlation between 5-Minute $^{99m}Tc-Pertechnetate$ Uptake and 24-Hour $^{131}I$ Uptake in Patients with Thyroid Disease (갑상선환자에서의 5분 $^{99m}Tc-Pertechnetate$ 섭취율과 방사성옥소섭취율의 상관관계)

  • Lee, Chan-Woo;Won, Kyu-Chang;Yoon, Hyun-Dae;Cho, In-Ho;Kim, Tae-Nyeun;Shin, Dong-Gu;Lee, Hyoung-Woo;Shim, Bong-Sup;Lee, Hyun-Woo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.26 no.2
    • /
    • pp.280-289
    • /
    • 1992
  • The 20-minute $^{99m}Tc-pertechnetate$ uptake became readily available for routine use and it replaced $^{131}I$ for thyroid imaging. However measuring thyroid uptake during a 5-minute minimizes pertechnetate uptake by the salivary glands and presence of contaminated saliva from those glands in to the pharynx and esophagus. A study was carried out to determine the suitability of the utility of a S-minute and 20-minute interval from administration of $^{99m}Tc-pertechnetate$ to imaging and uptake measurement as a replacement for the 24 hour standard originally established with $^{131}I$, and to evaluate the relationship between 5-minute $^{99m}Tc-pertechnetate$ uptake and other thyroid functions. A 5-minute and 20-minute uptake of $^{99m}Tc-pertechnetate$ were measured in 70 patients with thyroid disease at Yeungnam University Hospital from March 1, 1991 to Feb. 29, 1992. The results were as follows. 1) The 5-minute $^{99m}Tc-pertechnetate$ uptake in Graves' disease, Hashimoto's thyroiditis, simple goiter, non toxic nodular goiter, subacute thyroiditis and euthyroid were 18.2%, 14.6%, 2.8%, 3.2%, 1.2% and 1.1%, respectively. There was a significant difference between the mean of the euthyroid group and the mean of the Graves' disease. So differenciation between them can be easily made. 2) The 5 minute $^{99m}Tc-pertechnetate$ thyroid uptake was well correlated with 24 hour $^{131}I$ thyroid uptake (r=0.75, p<0.001). These data provided an equation for estimating the 24 hour uptake of iodide given the 5 minute pertechnetate uptake: Estimated 24-hour $^{131}I$ thyroid Uptake= 7.188*ln (5 minute $^{99m}Tc-pertechnetate$ uptake)+16.94 3) The 20-minute $^{99m}Tc-pertechnetate$ thyroid uptake was well correlated with 24-hour $^{131}I$ uptake (r=0.72, p<0.001) and 5-minute $^{99m}Tc-pertechnetate$ thyroid uptake (r=0.96, p<0.001). 4) In the Graves' disease, The 5-minute $^{99m}Tc-pertechnetate$ thyroid uptake was well correlated with serum $T_3-resin$ uptake (r=0.46, p<0.01), serum total $T_3$ (r=0.55, p<0.05), serum total $T_4$ (r=0.46, p<0.05). These results suggest that 5-minute ${99m}Tc-pertechnetate$ thyroid uptake has been found at least as useful as 24-hour $^{131}I$ uptake for diagnostic confirmation at our hospital, the logistical advantages of completing the diagnosis. The exam in 5-minutes led us to abandon the 24-hour study in the majority of patients, but the 24-hour $^{131}I$ uptake is still obtained in patients with planned or potential radioiodine therapy.

  • PDF

Change of the Result Value by the Amount of Samples in CA 19-9 (CA 19-9 검체량에 따른 농도의 변화)

  • Chang, Hyun-Yeong;Park, Hee-Won;You, Tae-Min;Noh, Kyung-Woon;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.66-73
    • /
    • 2008
  • Purpose: CA 19-9 need to examine a number of sample volume, and the postwar 200 U/ml concentration hook effect appears slight. Thus, the antibody-antigen reaction, and by reducing the amount of (sample volume), they can hook effect to minimize the impact of the sample volume and relevance know, I saw the hook effect. In addition, the current maximum of using the standard concentration of the reagent in 240 U/ml increase more than the standard concentration can be seen knows. Material and Method: 5 U/ml and under, make a few low concentration of serum pool from the high concentration of the sample hook effect together with a standard concentration of about 500 to meet the production. The reagents used in experiments are currently using SNUH NM experiment. Orignal method along with the experiment is to 25 ul sample volume (1 / 4), 50 ul (1 / 2), 100 ul (Orignal method) in the experiment. My greatest concentration of the reagent concentration of approximately two times the standard concentration of production. When was the last to make the first experiment, as measured by the standard concentration after that. The new inspection information through a standard solution modified by entering values in them. Results: 100 ul, and to apply the new standard concentration y = 1.3021x - 10.97, $R^2$ = 0.9844. Overall, the results showed a similar orignal method. Because of the concentration in the value of more than 240 U/ml, but it is an overall value that can be made out of a similar value When I put the 50 ul y = 1.045x + 9.5861, $R^2$ = 0.9428. Overall orignal method and the results of a similar value. 50 ul, and to apply the new standard concentration y=1.2006x+11.252, $R^2$=0.9423. Showing a slightly lower value compared with orignal method. Because of the concentration in the value of more than 240 U/ml, but it is an overall value that can be made out of a similar value. When I put the man 25 ul y=0.6012x+24.755, $R^2$=0.4033. Results showed that very small amounts of sample are insecure inside and showed a lower middle cpm orignal method and showed a lot of mismatched. Conclusions: 25 ul of the sample volume is not possible to use the instability had, when I put the 50 ul of the orignal method can be used to show a similar concentration. The new values are slightly lower concentration, The new values are slightly lower concentration, concentration, which are likely due to the lack of data has had a little gap between the sample showed 80 to 200 U/ml additional experiments seem to do. Apply a new 100 ul concentration values are applied to a large crowd is not even in sight. But this way the concentration of 100 to more 400 U/ml gather further experiments should possible adds.

  • PDF