• Title/Summary/Keyword: Data Type

Search Result 18,785, Processing Time 0.05 seconds

The Effects of The Distinction in Family Business on CEO Succession Types: A Behavioral Agency Theory Perspective (행동대리인 이론관점에서 가족기업 특성이 승계에 미치는 영향)

  • Kim, Ki-Hyung;Moon, Chul-Woo;Kim, Sang-kyun;Lee, Byung-Hee
    • Korean small business review
    • /
    • v.39 no.1
    • /
    • pp.1-39
    • /
    • 2017
  • The first generation of the business that had been founded in 1960~1970s faces the situation to consider the succession of the family business developed by devotion of their whole lives in the critical timing to the next generation. In the process of selecting the party of family business succession, it is required to consider a variety of succession types including smooth transfer to the other family member or the employee of the company, selling the company, or hiring external specialist. Foreign countries acknowledge the importance of the succession in the family owned company to perform multiple studies on the influential factors to the succession, distinction, and types of family business succession; and they utilize the results for the related policy development and the support of family owned business succession. However, few studies have been conducted on the succession of the domestic family owned business and majority of them are related to the types of succession. Considering its share and influential power in the domestic economy, it is necessary to develop the guideline and the policies to solve many issues on the succession of the family owned business by systemic studies. Hence, the impact of the main characteristics in the family owned business on the types of its succession was analyzed in this study focusing on five domains of Socioemtional Wealth (SEW) in view of Behavioral Agency Theory by Gomez-Mejia et al. (2007) using the data from 540 family owned small-to-medium sized businesses so as to analyze the issues on their business succession. Upon the empirical analysis results, it was confirmed that they were influenced to the selection of succession type by family succession > internal employee succession > external succession, for the variables of social contribution which were non-financial characteristics, internal employee succession > family succession > external succession for the intellectual properties, and family succession > external succession for the management participation of the family. The distinction of social contribution were influenced the most to the selection of the succession types. Financial factors, business performance, and R&D investment variables were not significantly influenced to their selection of the succession types. In case of simultaneous management, the family succession rate was high and it showed the control effect to strengthen selecting family owned business with R&D investment, social contribution, and company history variables. The behavioral agency theory used in this study was confirmed with high explanation power on the family owned business succession. The family owned business showed the tendency to maintain SEW, and non-financial factors such as accumulated know-how and social contribution based on the long term history were significantly affected to the succession in the small-to-medium sized family owned businesses, unlike general large sized listed companies. The results of this study are expected to be helpful practically for the succession of the family owned business and to suggest the guideline for the development of governmental policy.

Estimation of Rice Heading Date of Paddy Rice from Slanted and Top-view Images Using Deep Learning Classification Model (딥 러닝 분류 모델을 이용한 직하방과 경사각 영상 기반의 벼 출수기 판별)

  • Hyeok-jin Bak;Wan-Gyu Sang;Sungyul Chang;Dongwon Kwon;Woo-jin Im;Ji-hyeon Lee;Nam-jin Chung;Jung-Il Cho
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.25 no.4
    • /
    • pp.337-345
    • /
    • 2023
  • Estimating the rice heading date is one of the most crucial agricultural tasks related to productivity. However, due to abnormal climates around the world, it is becoming increasingly challenging to estimate the rice heading date. Therefore, a more objective classification method for estimating the rice heading date is needed than the existing methods. This study, we aimed to classify the rice heading stage from various images using a CNN classification model. We collected top-view images taken from a drone and a phenotyping tower, as well as slanted-view images captured with a RGB camera. The collected images underwent preprocessing to prepare them as input data for the CNN model. The CNN architectures employed were ResNet50, InceptionV3, and VGG19, which are commonly used in image classification models. The accuracy of the models all showed an accuracy of 0.98 or higher regardless of each architecture and type of image. We also used Grad-CAM to visually check which features of the image the model looked at and classified. Then verified our model accurately measure the rice heading date in paddy fields. The rice heading date was estimated to be approximately one day apart on average in the four paddy fields. This method suggests that the water head can be estimated automatically and quantitatively when estimating the rice heading date from various paddy field monitoring images.

Analysis of Fish Utilization and Effectiveness of Fishways Installed at Weirs in Large Rivers (대하천 보에 설치된 어도의 어류 이용 현황 및 효과 분석)

  • Jeong-Hui Kim;Sang-Hyeon Park;Seung-Ho Baek;Namjoo Lee;Min-Ho Jang;Ju-Duk Yoon
    • Korean Journal of Ecology and Environment
    • /
    • v.56 no.4
    • /
    • pp.348-362
    • /
    • 2023
  • This study analyzed the monitoring results of fishways at 16 weirs constructed on four large Rivers to provide data helpful for the operation and management of fishways. The average utilization rate of the fishways at the weirs was confirmed to be 64.9%. When comparing the dominant species in the mainstream and fishway monitoring results, differences were observed in 9 weirs (56.3%). This indicated that the species prevalent in the mainstream were not necessarily the ones most frequently using the fishways. The average number of individuals using the fishways per day was 336. When classifying the fish species using the fishway by life type, 92.3% were primary freshwater fish, and migratory species accounted for only 5.6%. Analysis based on the season of fishway usage revealed that an average or higher number of fish species used the fishways from May to October, with the highest number of individual users occurring from June to August. Between May and July, 80% of the fish species using the fishways were in their spawning period, while during other season, less than 40% were species that move during the spawning period. The fishways that showed a significant alignment between the spawning period and the fishway passage period were Rhinogobius brunneus, Leiocassis nitidus, Squalidus chankaensis tsuchigae, Pseudogobio esocinus, Acheilognathus rhombeus, and Pungtungia herzi, in that order. When comparing the fishway monitoring results of the Gangjeong-Goryeong Weir and the Dalseong Weir with the upper part water level of the weir, both the number of fish species and individuals using the fishway showed positive correlations with the upper part water level of the weir. This suggests that a higher water level of the weir increases the inflow discharge within the fishway, leading to increased use by fish (number of individuals in Gangjeong-Goryeong Weir, P<0.001; number of species in Dalseong Weir, P<0.05). This study summarized and analyzed the results of fishway monitoring at 16 weirs built on four large Rivers, considering fishway efficiency, operation and management, monitoring period, and regulation of water level in the upper part of the weir. It is thought that this will help understand the status of fish use in fishways on large River and aid the construction, operation, and management of fishways in the future.

Investigation of Internal Temperature Distribution in Domestic Refrigerators and Freezers (가정용 식품 냉장고와 냉동고의 내부 온도 분포 실태 조사)

  • Dong Bin Lee;Jong Eok Kim;Ja Yeong Lee;Sang Gu Kim;Sang Yun Lee
    • Journal of Food Hygiene and Safety
    • /
    • v.38 no.5
    • /
    • pp.373-380
    • /
    • 2023
  • This study surveyed and compared the temperature distribution in domestic refrigerators and freezers used in Korea to determine whether temperature varied according to the location of food storage. We selected 50 people to collect temperature data; among them, 25 measured the temperature of refrigerators, while the remaining measured the temperature of freezers. Consequently, the lowest and highest temperatures measured in domestic refrigerators were found to be -8.2℃ and 15.8℃, respectively, with an average temperature of 3.73℃. The temperature distribution based on internal location was: 5.06±1.69℃ for the door storage compartment, 4.18±1.19℃ for the inside wall surface, and 3.41±1.36℃ for the inner storage box. Significant temperature differences between the top and bottom were only identified at the door storage compartment (P<0.01). Further, the minimum and maximum temperatures measured in the freezer was -30.3℃ and 0.7℃, respectively, with an average temperature of -17.95℃. The temperature distribution based on location was: -17.19±1.68℃ for the door storage compartment, -17.81±1.07℃ for the inside wall surface, and -18.78±1.72℃ for the inside storage box. The results were similar to that of the refrigerator, with the lowest temperature in the inside storage box, and a significant temperature difference between the top and bottom noted only at the door (P<0.01). The maximum temperature difference (between locations) within the refrigerator and freezer was found to be 2.18 and 2.02℃, respectively. In conclusion, the temperature in the entire space was not constant; there were significant deviations at different storage locations. Therefore, public authorities should actively advise customers on the recommended storage locations for each food type. People will benefit from awareness about storage management, including avoiding storage of temperature-sensitive foods in door compartment.

A Study on the Success Factors of Co-Founding Start-up by Step: Focusing on the Case of Opportunity-type Start-up (공동창업의 단계별 성공요인에 관한 연구: 기회형 창업기업 사례를 중심으로)

  • Yun, Seong Man;Sung, Chang Soo
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.18 no.1
    • /
    • pp.141-158
    • /
    • 2023
  • From the perspective of an entrepreneur, one of the most important factors for understanding the inherent limitations of a startup, reducing the risk of failure, and succeeding is the composition of the talent, that is, the founding team. Therefore, a common concern experienced by entrepreneurs in the pre-entrepreneurship stage or the early stage of startup is the choice between independent startups and co-founding start-up. Nonetheless, in Korea, the share of independent entrepreneurship is significantly higher than that of co-founding start-up. On the other hand, focusing on the fact that many successful global innovative companies are in the form of co-founding start-up, the success factors of co-founding start-up were examined. Most of the related preceding studies are studies that identify the capabilities and characteristics of individual entrepreneurs as factors influencing the survival and success of entrepreneurship, and there is a lack of research on partnerships, that is, co-founding start-up, which are common in the field of entrepreneurship ecosystems. Therefore, this study attempted a multi-case study through in-depth interviews, collection of relevant data, analysis of contextual information, and consideration of previous studies targeting co-founders of domestic startups that succeeded in opportunistic startups. Through this, a model for deriving the phased characteristics and key success factors of co-founding start-up was proposed. As a result of the study, the key element of the preliminary start-up stage was 'opportunity', and the success factors were 'opportunity recognition through entrepreneur's experience' and 'idea development'. The key element in the early stages of start-up is "start-up team," and the success factor is "trust and complement of start-up team," and synergy is shown when "diversity and homogeneity of start-up team" are harmonized. In addition, conflicts between co-founders may occur in the early stages of start-ups, which has a large impact on the survival of start-ups. The conflict between the start-up team could be overcome through constant "mutual understanding and respect through communication" and "clear division of work and role sharing." It was confirmed that the core element of the start-up growth stage was 'resources', and 'securing excellent talent' and 'raising external funds' were important factors for success. These results are expected to overcome the limitations of start-up companies, such as limited resources, lack of experience, and risk of failure, in entrepreneurship studies, and prospective entrepreneurs preparing for a start-up in a situation where the form of co-founding start-up is attracting attention as one of the alternatives to increase the success rate. It has implications for various stakeholders in the entrepreneurial ecosystem.

  • PDF

Changes in the Behavior of Healthcare Organizations Following the Introduction of Drug Utilization Review Evaluation Indicators in the Healthcare Quality Evaluation Grant Initiative (의료질평가지원금 제도의 의약품안전사용서비스 평가지표 도입에 따른 의료기관의 행태 변화)

  • Hyeon-Jeong Kim;Ki-Bong Yoo;Young-Joo Won;Han-Sol Jang;Kwang-Soo Lee
    • Health Policy and Management
    • /
    • v.34 no.2
    • /
    • pp.178-184
    • /
    • 2024
  • Background: This study aimed to determine the effectiveness of drug utilization review (DUR) evaluation indicators on safe drug use by comparing the changes in DUR inspection rates and drug duplication prescription prevention rates between the pre- and post-implementation of the DUR evaluation indicators of the Healthcare Quality Evaluation Grant Initiative. Methods: This study used DUR data from the Health Insurance Review and Assessment Service in 2018 (pre-implementation) and the evaluation results of the Healthcare Quality Evaluation Grant Initiative in 2023 (post-implementation). The dependent variables were the DUR evaluation indicators, including DUR inspection rate and drug duplicate prescription prevention rate. The independent variable was the implementation of the DUR evaluation indicators, and the control variables included medical institution characteristics such as type, establishment classification, location, DUR billing software company, and number of beds. Results: The results of the analysis of the difference in the prevention rate of drug duplicate prescriptions between the pre- and post-implementation of the DUR evaluation indicators of the Healthcare Quality Evaluation Grant Initiative showed that the prevention rate of drug duplicate prescriptions increased statistically significantly after the implementation of the DUR evaluation indicators. Conclusion: The policy implications of this study are as follows: First, ongoing evaluation of DUR systems is needed. Second, it is necessary to establish a collaborative partnership between healthcare organizations that utilize DUR system information and the organizations that manage it.

Periodontal status of end-stage renal disease patients undergoing dialysis and referred for intraoral evaluation prior to kidney transplant surgery (투석을 받고 있으며 신장 이식 수술 전 구강내 평가를 위해 의뢰된 말기 신장 질환 자의 치주 상태)

  • Youn-Kyung Choi;Hye-Mi Jeon;Ji-Young Joo;Hyun-Joo Kim;Eun-Young Kwon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.40 no.2
    • /
    • pp.46-54
    • /
    • 2024
  • Purpose: The purpose of this study was to compare the periodontal status of end-stage renal disease patients undergoing dialysis and referred for intraoral evaluation prior to renal transplantation surgery with those having normal kidney function. Materials and Methods: Patients who had been undergoing dialysis for end-stage renal disease and been referred to the Dental Clinic Center by the Department of Nephrology at University Hospital for intraoral evaluation prior to kidney transplantation surgery. For comparison of periodontal status, subjects without abnormalities in kidney function were matched with the patients by age and gender and selected as healthy controls. The patients' age, gender, comorbidities, type of dialysis received, and duration of dialysis were investigated by reference to their medical records, and data on their periodontal status were analyzed via the relevant periodontal records. Results: A total of 102 patients, including 51 dialyzed patients and 51 healthy control group subjects, participated in this study. In the patients with end-stage renal disease undergoing dialysis with periodontal probing depth of 5 mm or more, percentage of sites with clinical attachment level of 4 mm or more, percentage of teeth with bleeding on probing, number of missing teeth, and ratio of moderate to severe periodontitis were all significantly greater than in the healthy controls. Conclusion: The periodontal status of end-stage renal disease patients undergoing dialysis and referred for intraoral evaluation prior to kidney transplantation was worse than that of healthy controls.

Evaluation of Eco-friendliness for Major Development Projects by EA-INDEX in South Korea (EA-INDEX를 활용한 국내 주요 개발사업의 친환경성 평가)

  • Jihyeon Park;Hyun-Jin Choi
    • Journal of Environmental Impact Assessment
    • /
    • v.33 no.3
    • /
    • pp.131-141
    • /
    • 2024
  • The environmental impact assessment have been played important role for sustainable development of the country. Meantime, various studies have been conducted for scientific and effective environmental impact assessment. Howeverthe quantitative data such as regional distribution status and development characteristics according to the type of development project, environmental changes due to development projects, and spatial-temporal changes are insufficient, currently. In this study, we investigated the eco-friendliness of major development projects (industrial complex, urban development, tourist complexes, and waste disposal equipments) by integrating the EA-INDEX of each development projects which were reported by prior researches. As a result, we found that the eco-friendliness of development projects tended to gradually increase overtime due to the increase in eco-friendliness in the protection of living environment sector. The protection of living environment sector was a major factor in the the eco-friendliness of industrial complexes and urban development projects. In the case ofroad construction, landfill and tourist complex development projects, the natural environment conservation sector was a major factor in the eco-friendliness of the project. As a result of analyzing the eco-friendliness of development projects by local government, the eco-friendliness of development projects promoted and implemented in Ulsan, Jeonnam, and Gwangju was higher compared to other regions, and it was relatively low in Daejeon, Gyeongnam, and Daegu. This study is considered to be significant in that it conducted a quantitative analysis of the eco-friendliness of development projects carried out over a relatively long period of time throughout South Korea by dividing them by year and local government.

Preference and Sensory Trait Analysis of Korean Rice Varieties among International Consumers (해외소비자의 국내육성 벼 품종에 대한 선호도 및 식미관련 형질 분석)

  • Chang-Min Lee;Song-Hee Park;Su-Kyung Ha;Hyun-Sook Lee;Gileng Lee;Seung Young Lee;Ji-Ung Jeung;Hyun-Su Park;Jae-Ryoung Park;O-Young Jeong
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.68 no.4
    • /
    • pp.262-275
    • /
    • 2023
  • This study aimed to assess the preferences of African, American, and Asian panels, in comparison to a Korean panel, for various Korean rice varieties, including three japonica, two indica, and one Tongil-type, all developed by the Rural Development Administration in Korea. Regarding rice appearance, most panelists, except for the Koreans, favored long and slender rice varieties like 'Hanyeol', 'Hyangyeol', and 'Amissal'. In contrast, the Koreans preferred wider varieties like 'Sindongjin' and 'Deuraehyang'. Notably, the overseas panelists consistently favored rice varieties with high appearance quality in sensory evaluations of cooked rice. Both overseas and Korean panelists strongly preferred the indica rice variety 'Hanyeol' in terms of appearance quality and sensory evaluations. However, Korean rice varieties like 'Amissal' and 'Sindongjin' scored high in appearance quality with overseas panelists but received low ratings in sensory aspects, including shape, stickiness, and taste, compared to those for 'Hanyeol'. This suggests that considering sensory characteristics is important when exporting Korean rice varieties. Regarding taste characteristics preferred by the panelists derived from the correlation analysis between taste traits, Africans preferred rice with a smooth texture and no stickiness, especially favoring long-grain rice. Americans leaned towards rice with a slightly firm texture, some stickiness, and late aging characteristics. Asians preferred rice with a smooth texture, low stickiness, and long-grain varieties. In contrast, Koreans favored round rice with a glossy appearance, a slightly firm texture, late aging traits, and some stickiness. These research findings can serve as valuable data for the development of rice varieties for overseas markets and are expected to contribute to securing competitiveness in international markets.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF