• Title/Summary/Keyword: Data Converter

Search Result 623, Processing Time 0.024 seconds

Grid faults characteristics simulation of inverter-fed induction generator (인버터 부착형 농형 유도발전기의 계통고장특성 모의)

  • Hong, Jitae;Kwon, Soonman;Kim, Chunkyung;Lee, Jongmoo;Cheon, Jongmin;Kim, Hong-Ju;Kim, Heeje
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.43.1-43.1
    • /
    • 2011
  • The detail simulation modeling of fully-fed induction generator is investigated through PC based MATLAB/Simulink environment. Generator's stator currents are controlled by indirect vector control method. In this method, generator side converter controls the maximum excitation (air gap flux) by stator d-axis current and controls generator torque by stator q-axis current. Induction generator speed is controlled by tip speed ratio (TSR) upon the wind speed variations in order to generate the maximum output power. The generator torque model is specified as a 3-blade wind turbine with rating, then, the model is simulated under normal operating condition and three different fault conditions. The matlab model designed for fully-fed induction generator based wind farm provides good performance under normal and grid fault conditions. It provides good results for different pwm techniques and fault conditions except the single-phase line to ground fault, which should be verified with real time data from wind farms.

  • PDF

Unmanned Patient Monitoring System Using Frame Difference Method and Decibel Threshold (프레임 차이법과 데시벨 임계치를 이용한 무인 환자 감시 시스템)

  • Lee, Kee-Woo;Lee, Hyuk-Soo
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.8 no.1
    • /
    • pp.1-5
    • /
    • 2007
  • In this paper, we propose an unmanned patient monitoring system design and performance of a motion capture and sound detection. Unmanned patient monitoring system can be used in the greek koma and meaning deep sleep patient to need 24 hour surveillance. To monitoring, we used laptop, CCTV camera (or PC camera), A/D converter, microphone and detection program. The detection program based on the frame difference method and sound level meter. It had several functions such as data collecting and storing. All of this system was tested in several the simulations of emergency situations. It can be expected that an unmanned patient monitoring system can be used in emergency situation and patient care.

  • PDF

Characteristics analysis of Residential 3kW PV System (주택용 3kW 태양광발전시스템의 구성요소법 특성 분석)

  • Bian, W.J.;Piao, Z.G.;Lim, H.W.;Lee, K.Y.;Cho, G.B.;Baek, H.L.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.1181-1182
    • /
    • 2006
  • The solar power system comprises a solar battery that directly converts light energy to electrical energy with a photovoltaic effect and a power converter system, that is, inverter that converts direct current power, which is generated from solar battery to common alternating current. In this paper, database was constituted through remote monitoring supervision measurement for the long-time positive operation of 3kW solar power system installed within the solar energy positive research complex of Chosun University. As a result of analyzing the reduction of the efficiency of solar battery and inverter that are compositional components of PV system through an analysis on the acquired data, the PV output was proven over 65% of the total output when insolation intensity exceeded 600W/m2 in 2005, and the array conversion efficiency dropped much more than rating; meanwhile, insolation intensity dropped below 600W/m2. Therefore, it has been demonstrated that approximately 35% of the entire amount of PV output operated under the condition that the inverter efficiency rate dropped rapidly by 60 to 70%.

  • PDF

Measurement of Ion Energy Distribution using QMS & Ionization Enhancement by usign Magnetic Field in Triod BARE (자장을 이용한 이온화율 증대형 삼극형 BARE에서 이온화율의 증대경향과 QMS를 이용한 이온의 에너지 분포 측정)

  • 김익현;주정훈;한봉희
    • Journal of the Korean institute of surface engineering
    • /
    • v.24 no.3
    • /
    • pp.119-124
    • /
    • 1991
  • Recently, the trend of research in hard coating is concentrate on developing the process of ionization rate under low operating pressure, to get the thin film with high adhesion and dense microstructures. In this study ionization rate enhancement type PVD process using permanent magnet is developed, which enhances the ionization rate by confining the plasma suppressing the wall loss of electron. By the result to investigate the characteristic of glow discharge, the ionization rate of this process is enhanced about twice as high as that of triod BARE process (about 26%), and more dense TiN microstructures are obtained in this process. Cylindrical ion energy analyzer is made and attached in front of a quadrupole mass filter for the analysis of the energy distribution of reactive gas and activated gas ions from the plasma zone. To analyze the operation mechanism of ion energy analyzer, computer simulation is performed by calculation the electric field environment using finite element method. By these analyses of ion energy distribution of outcoming ions from the plasma zone, it is found that magnetic field enhances ion kinetic energy as well as ionization rate. The other results of this study is that the foundation of feed-back system is constructed, which automatically control the partial pressure of reactive gas. In can be possible by recording the data of mass spectrum and ion energy analysis using A-D converter.

  • PDF

Detection of Blood Agent Gas Using $SnO_2$ Thin Film Gas Sensor

  • Choi, Nak-Jin;Kwak, Jun-Hyuk;Lim, Yeon-Tae;Joo, Byung-Su;Lee, Duk-Dong;Bahn, Tae-Hyun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.E2
    • /
    • pp.69-75
    • /
    • 2004
  • In this study, thin film gas sensor based on tin oxide was fabricated to examine its characteristics. Target gas is acetonitrile ($CH_3$CN) which is a blood simulant for the chemical warfare agent. Sensing materials are SnO$_2$ SnO$_2$/Pt, and Sn/Pt with thickness from 1000 to 3000 $\AA$. The sensor consists of a sensing electrode with inter-digit (IDT) type in front side and a heater in rear side. Resistance changes of sensing materials are monitored on real time basis using a data acquisition board with a 12-bit analog to digital converter. Sensitivities are measured at different operating temperatures also with different gas concentrations and film thickness. The high sensitivity is obtained for Sn (3000 $\AA$)/Pt (30 $\AA$) at 30$0^{\circ}C$ for 3 ppm. Response and recovery times were about 40 and 160 s, respectively. Repetition measurements showed very good results with $\pm$3% in full scale range.

The Overall Measurement System Development for On-line Test of Super-speed Maglev Train (초고속 자기부상철도 시운전시험을 위한 종합계측시스템 개발)

  • Han, Young-Jae;Lee, Jin-Ho;Jo, Jung-Min;Kim, Lee-Hyung;Lee, Chang-Young;Ha, Chang-Wan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.5
    • /
    • pp.902-910
    • /
    • 2016
  • This paper presents the overall measurement system for on-line test of super-speed maglev train. The super-speed maglev train is composed of vehicle, propulsion, power, and so on. In order to evaluate and diagnose for sub-system, we made overall measurement system. Just like the other measurement system, it is designed to distributed type. The hardware is consist of SCXI, PXI, Terminal, UPS, and so forth. It is installed on a train, control room, power room and track to collect lots of signals. The software controls hardware system, monitors main data such as inverter current, converter voltage. Using the measurement system, we evaluated a lot of performances for vehicle, track, and so forth. Through the developed system have improved reliability and safety for super-speed maglev train.

Posture for Distortion Measurement and Analysis Through the Pressure Distribution During a Person Walking (인체보행 시 양발에 가해지는 압력분포를 통한 자세 뒤틀림 측정 및 분석)

  • Hong, Ju-Hee;Kim, Kyung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.3
    • /
    • pp.487-492
    • /
    • 2016
  • In this paper, a device for analyzing the pressure distribution during walking was produced by using the pressure sensor on the heel. This device was limited to a frequency band by using the 1st low-pass filter. And an algorithm to analyze the value of the quantity to pressure using a analog to digital converter. It is used by using the threshold voltage of pressure sensor, it is suggested the algorithm. The algorithm is detected the peak which is exceeded the threshold voltage. and thus in accordance, it is detected the number of steps. And the calorie consumption were detected by using it. Also it used an MCU and Bluetooth. And by confirming the data at the LCD of the other MCU, it was to reduce the size of the device. According to this algorithm, it has the advantage that there is no restriction on the activity than when using an imaging device and it is inexpensive than other sensors such as an acceleration sensor or a gyro and it is easy to handle.

Development of DICOM Convert Program for the Geant4 Monte Carlo Simulation of the Radiotherapy (방사선치료의 Geant4 전산모사를 위한 DICOM 변환 프로그램 개발)

  • Kang, Jeongku;Lee, Dong Joon
    • Progress in Medical Physics
    • /
    • v.24 no.4
    • /
    • pp.259-264
    • /
    • 2013
  • The DICOM converter program of the Geant4 Monte Carlo simulation code for the application of radiotherapy was developed. We analysis the header part of the DICOM file and find various parameters, such as matrix size, pixel size, stored data bits, high bit, and padding values. Especially we evaluate every pixel value of the DICOM files. To conform the exact convert of the pixel values, we developed the verify program. As a result, the DICOM formats generated from difference CT vendors can be converted and verified for Genat4 calculations.

Modification of an Analysis Algorithm for DC Power Systems Considering Scalable Topologies

  • Lee, Won-Poong;Choi, Jin-Young;Park, Young-Ho;Kim, Soo-Nam;Won, Dong-Jun
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.5
    • /
    • pp.1852-1863
    • /
    • 2018
  • Direct current(DC) systems have recently attracted attention due to the increase in DC loads and distributed generations, such as renewable energy sources. Among these technologies, there has been much research into DC distribution systems or DC microgrids. Within this body of research, the main topics have been about optimum control and operation methods in terms of improving power efficiency. When DC systems are controlled and operated using power electronic devices such as converters, it is necessary to design and analyze them by considering the power electronics sections. For this reason, we propose a scalable DC system analysis algorithm, which considers various system configurations depending on the operating mode and location of the converter. The algorithm consists of power flow fault current calculations, and the results of the algorithm can be used for designing DC systems. The algorithm is implemented using MATLAB with defined input and output data. The verification of the algorithm is mainly performed using ETAP software, and the accuracy of the algorithm analysis can be confirmed through the results.

Development of Wide-Range Brightness Controller of LED Backlight for Avionic Displays (항공기 디스플레이용 LED 백라이트의 광대역 휘도 제어기 개발)

  • Lim, Soo-Hyun;Lim, Jeong-Gyu;Chung, Se-Kyo;Shin, Hwi-Beom;Shin, Min-Jae;Sohn, Seung-Gul
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.13 no.4
    • /
    • pp.287-294
    • /
    • 2008
  • This paper describes an implementation of a wide-range dimming controller of a LED backlight for Avionics applications such as a control display unit(CDU) and multi-function display(MFD). The digital dimming controller employing a current controlled buck converter and light sensor feedback is proposed. The proposed system provides a wide dimming control range of from 150fL to 0.05fL(3000:1) required for avionic displays. The experimental results are provided to show the control performance.