• Title/Summary/Keyword: Dangerous Power Facilities

Search Result 15, Processing Time 0.042 seconds

A Study on the Pressure Sensor for the Direct Detection of the Approach to the Dangerous Power Facilities Using Pb-free BNKT Ceramics (무연 BNKT 세라믹스를 이용한 위해(危害)전력설비 접근 직접감지용 압력센서에 관한 연구)

  • Hong, Jae-Il;Yoo, Ju-Hyun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.55 no.1
    • /
    • pp.31-34
    • /
    • 2006
  • A infrared rays sensor or ultrasonic sensor can detect the object at the narrow area, however a pressure sensor can detect man and animal at the wide area. It is necessary to manufacture the sensor by using Pb-free ceramics in the respect of environmental protection. Piezoelectric properties of ceramics added 0.2wt% $La_2O_3\;into\;0.96Bi_{0.5}(Na_{0.84}K_{0.16})_{0.5}+0.04SrTiO_3$ were 0.4 of kp, $31{\times}$10^{-3}Vm/N\;of\;g_{33}$. The output voltage of the pressure sensor is 0.48 V at 20 in$H_2O$. The output voltage of the pressure sensor with driving circuit is 9.8 V, 37 ms width.

Design and Implementation of Low Power Consumption Wireless Sensor Network Platform for Intelligent Motorway Monitoring (USN 기반 지능형 도로상태 모니터링을 위한 저전력 센서네트워크 플랫폼 구현)

  • Song, Min-Hwan;Kim, Jae-Ho;Ahn, Il-Yeop;Kim, Tae-Hyun;Park, Young-Kuk;Won, Kwang-Ho;Lee, Sang-Shin
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2008.08a
    • /
    • pp.463-465
    • /
    • 2008
  • This article describes a design and implementation of low power consumption wireless sensor network platform for intelligent motorway monitoring. There are many dangerous situations on motorway, foggy weathers, rapidly changes of temperature, etc. We designed a system for monitoring motorway environment for report dangerous situation. We introduce this system and its lowpower consumption characteristics which important to battery based system.

  • PDF

Algorithm of Line dangerous Index and Predicting Distance Relay Zone 3 acting time by using real time data (실시간 데이터를 이용한 선로 위험도 산출 알고리즘 및 거리계전기 Zone 3 동작 예측 알고리즘)

  • Kim, Jin-Hwan;Lee, Seung-Jae;Choi, Myeon-Song;Lim, Il-Hyung;Lim, Seong-Il;Kim, Sang-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.278_279
    • /
    • 2009
  • Nowaday, many people study about Black-Out. In this paper, I introduce how to calculate the Dangerous Index against Black-Out, and prediction of Distance relay error action on Zone 3. we consider the real data by I-PIU which will be set on the system. The dangerous Index is calculated three index about Cascading. The prediction of Distance relay is considered by other facilities of power system. This two algorithm can be used on the center system, when the system is on danger, also on the normal states for security.

  • PDF

A Study on the Characteristic of Power Transmission by the Power-take-off(P.T.O.) of farm Tractor (Tractor 동력취출장치(P.T.O.)의 동력전달구조에 관한 연구)

  • 송현갑
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.15 no.3
    • /
    • pp.3089-3095
    • /
    • 1973
  • The power transmission to the traction devices may be very important for the tractor performance and therefore this system has been studied very much in the past. On the other hand, the PTO(Power-take-off) has been considered as an accessary on the tractor with a few work for its power transmission. Because of increased use of PTO operation in various kind of farming operations in recent years, the function of PTO may become such important as the traction facilities. In this study, the power transmission characteristics of PTO drive was analyzed theoretically and some experimental work was done to study on it. The results of the study are as follows: 1) The most stable condition of PTO work was obtained when the intersection angle of the two curves for driving and driven torques was about ${\pi}/2$. 2) To obtain the most stable operation it is better to use both the speed control and the full control together. 3) Six steps differential gear may not be enough to use the PTO power smoothly. It is thought that the three steps differential gear on the shaft of PTO may be necessary additionally for a smooth operation. 4) When the traction facilities and the PTO are used at the same time, the torque of crank shaft becomes Tt + Tp, and the high efficiency and good stability of word will be obtained with the small variation of driving speed. 5) When the tractor was operated with 75% of the rated horse power and 70% of maximum speed, the best thermal efficiency could be obtained. 6) The most dangerous sound for human occured at the rated speed of PTO and tus it may be necessary to control the dangerous noise.

  • PDF

The Development of Robot Control System for Nuclear Facilities

  • Lee, Sung-Uk;Kim, Chang-Hoi;Jeong, Seong-Ho;Kim, Seung-Ho
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2696-2700
    • /
    • 2003
  • Nuclear robots should be developed for the reduction of radiation exposure, lower man hours, shorter power outage, and also improved worker safety concerns in performing hazardous and dangerous tasks. Among the components of a nuclear robot system, a robot control system equivalent to a human brain is a crucial point because a nuclear robot does not work without a control system. Therefore, in this paper, we will explain the requirements for a robot control system for a nuclear robot from a general point of view and also review the robot control systems of nuclear robots that were developed domestically, to assist a researcher beginning with the design for the control system of nuclear robots. The explained robot control system will be useful to develop the control system for industrial robots, home robots and other robots which are needed for tele-operation and are controlled through the internet.

  • PDF

Power Hardware-in-the-Loop (PHIL) Simulation Testbed for Testing Electrical Interactions Between Power Converter and Fault Conditions of DC Microgrid (컨버터와 DC 마이크로그리드 사고 상황의 상호작용을 검증하기 위한 실시간 전력 시뮬레이션 테스트 베드)

  • Heo, Kyung-Wook;Jung, Jee-Hoon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.2
    • /
    • pp.150-157
    • /
    • 2021
  • Nowadays, a DC microgrid that can link various distributed power sources is gaining much attention. Accordingly, research on fault situations, such as line-to-line and line-to-ground faults of the DC microgrid, has been conducted to improve grid reliability. However, the blackout of an AC system and the oscillation of a DC bus voltage have not been reported or have not been sufficiently verified by previous research. In this study, a 20 kW DC microgrid testbed using a power HIL simulation technique is proposed. This testbed can simulate various fault conditions without any additional grid facilities and dangerous experiments. It includes the blackout of the DC microgrid caused by the AC utility grid's blackout, a drastic load increment, and the DC bus voltage oscillation caused by the LCL filter of the voltage source converter. The effectiveness of the proposed testbed is verified by using Opal-RT's OP5707 real-time simulator with a 3 kW prototype three-port dual-active-bridge converter.

A Study on the Direct Discharge Test for Verifying Design Concentration and Soaking Time for CO2 Fire Extinguishing System of Total Flooding (전역방출방식 CO2 소화설비의 설계농도 및 유지시간 검증을 위한 직접방사실험에 관한 연구)

  • Lee, Se-Myeoung;Moon, Sung-Woong;Ryu, Sang-Hoon
    • Fire Science and Engineering
    • /
    • v.26 no.6
    • /
    • pp.15-23
    • /
    • 2012
  • Indirect Test Method is often used instead of direct test method in test method for extinguishing performance of $CO_2$ extinguishing facility because of high cost, environment problems and difficulties of procedure. But in the danger facilities for a unit of nation, such as a petrochemical plant, a nuclear power plant, or etc. is better to verify the performance of the extinguishment through direct discharge test. In $CO_2$ extinguishing system for total flooding system installed in dangerous facilities in Korea, each protected area in surface fire and deep-seated fire had selected and verified of extinguishing performance of $CO_2$ extinguishing facilities. To get recognized as extinguishing performance, discharged $CO_2$ concentration to protected area should be equivalence with design concentration standards (NFSC and NFPA). The Design Concentration means that $CO_2$ extinguishing agent is considerate of concentration for percentage of allowance (20 %) from extinguishing concentration which available to control of flame. As test result, surface fire and deep seated fire in protected area is obtained $CO_2$ design concentration and maintained design concentration more than 20 minutes as deep-seated fire. Through this study, we introduced direct discharging test method and decision method. And furthermore, especially in the dangerous facilities as a unit of Nation, we suggested necessity about reliability of extinguishing facilities to use direct test method.

A Study on Seismic Liquefaction Risk Map of Electric Power Utility Tunnel in South-East Korea (국내 동남권 지역의 전력구 지반에 대한 지진시 액상화 위험도 작성 연구)

  • Choi, Jae-soon;Park, Inn-Joon;Hwang, Kyengmin;Jang, Jungbum
    • Journal of the Korean GEO-environmental Society
    • /
    • v.19 no.10
    • /
    • pp.13-19
    • /
    • 2018
  • Following the 2016 Gyeongju earthquake, the Pohang Earthquake occurred in 2017, and the south-east region in Korea is under the threat of an earthquake. Especially, in the Pohang Earthquake, the liquefaction phenomenon occurred in the sedimentation area of the coast, and preparation of countermeasures is very important. The soil liquefaction can affect the underground facilities directly as well as various structures on the ground. Therefore, it is necessary to identify the liquefaction risk of facilities and the structures against the possible earthquakes and to prepare countermeasures to minimize them. In this study, we investigated the seismic liquefaction risk about the electric power utility tunnels in the southeast area where the earthquake occurred in Korea recently. In the analysis of seismic liquefaction risk, the earthquake with return period 1000 years and liquefaction potential index are used. The liquefaction risk analysis was conducted in two stages. In the first stage, the liquefaction risk was analyzed by calculating the liquefaction potential index using the ground survey data of the location of electric power utility tunnels in the southeast region. At that time, the seismic amplification in soil layer was considered by soil amplification factor according to the soil classification. In the second stage, the liquefaction risk analysis based on the site response analyses inputted 3 earthquake records were performed for the locations determined to be dangerous from the first step analysis, and the final liquefaction potential index was recalculated. In the analysis, the site investigation data were used from the National Geotechnical Information DB Center. Finally, it can be found that the proposed two stage assessments for liquefaction risk that the macro assessment of liquefaction risk for the underground facilities including the electric power utility tunnel in Korea is carried out at the first stage, and the second risk assessment is performed again with site response analysis for the dangerous regions of the first stage assessment is reasonable and effective.

Study on Improving the Facilities of Power-Driven Water Leisure Crafts for the Deaf (청각장애인을 위한 동력수상레저기구 운영 개선방안에 관한 연구)

  • Won-Sam Choi;Bong-Kyu Jung;Cheor-Hong Park;Nam-U Lee
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.29 no.7
    • /
    • pp.836-842
    • /
    • 2023
  • Under the Welfare of Disabled Persons Act, the national qualification test allows disabled and non-disabled people to appear for the same test, and the deaf do not fall under the reason for disqualification from obtaining a license for power-driven water leisure crafts; therefore, even the deaf can obtain a license. During a risk of collision at sea, ships and power-driven water leisure crafts notify the other party of dangerous signals such as maneuvering and warning signals through sound signals to prevent accidents that may occur because surrounding ships are not visible. However, a method is required to prevent marine accidents that may occur when the deaf cannot hear danger signals through sounds from nearby ships or power-driven water leisure crafts during leisure activities owing to hearing impairment. A sound reception system is a device installed on a ship where missionary work is completely deposed to display the amplification of external sounds and the direction of sound reception on the screen. Through visual display of sound signals such as dangerous signals that cannot be heard owing to hearing impairment, improvement measures were proposed to prevent marine accidents that can occur owing to the inability of the deaf to check sound signals during leisure activities.

Development of Fault Prediction System Using Peak-code Method in Power Plants (피크코드 기법을 이용한 발전설비 고장예측 시스템 개발)

  • Roh, Chang-Su;Do, Sung-Chan;Chong, Ui-Pil
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.9 no.4
    • /
    • pp.329-336
    • /
    • 2008
  • The facilities with new technologies in the recent power plants become larger and need a lot of high cost for maintenance due to stop operations and accidents from the operating machines. Therefore, it claims new systems to monitor the operating status and predict the faults of the machines. This research classifies the normal/abnormal status of the machines into 5 levels which are normal-level/abnormal-level/care-level/dangerous-level/fault and develops the new system that predicts faults without stop operation in power plants. We propose the regional segmentation technique in the frequency domain from the data of the operating machines and generate the Peak-codes similar to the Bar-codes, The high efficient and economic operations of the power plants will be achieved by carrying out the pre-maintenance at the care level of 5 levels in the plants. In order to be utilized easily at power plants, we developed the algorithm appling to a notebook computer from signal acquisition to the discrimination.

  • PDF