• Title/Summary/Keyword: Dangerous Case

Search Result 352, Processing Time 0.024 seconds

Biplane Fluoroscopy Guided Maxillary Nerve Block and Pulsed Radiofrequency Lesioning of the Mandibular Nerve -A report of two cases- (양면 투시기를 이용한 상악 신경 블록과 신경 박동성 고주파술의 치료 경험 -증례 보고-)

  • Lee, Eun Hyeong;Park, Sang Ri;Joh, Ju Yeon;Han, Sun Sook;Lee, Chul Joong;Lee, Sang Chul
    • The Korean Journal of Pain
    • /
    • v.18 no.2
    • /
    • pp.279-283
    • /
    • 2005
  • Biplane fluoroscopy is usually used in angiography. Biplane fluoroscopy gives a biplane image with high resolution during the performance of operations. Trigeminal nerve blocks are effective treatment modalities for trigeminal neuralgia, and maxillary nerve block is the most dangerous procedure among them. The anatomic structures can change after head and neck surgery, so the trigeminal nerve block procedures cannot be done so easily. We used biplane fluoroscopy in these difficult cases. Our first case was a 60-year-old man who had undergone maxillary nerve block. The second case was of a 64-year-old man who had pulsed radiofrequency lesioning of mandibular nerve performed after head and neck surgery. With biplane fluoroscopy, we got good results without any complications.

Evaluating fire resistance of prestressed concrete bridge girders

  • Zhang, Gang;Kodur, Venkatesh;Hou, Wei;He, Shuanhai
    • Structural Engineering and Mechanics
    • /
    • v.62 no.6
    • /
    • pp.663-674
    • /
    • 2017
  • This paper presents an approach for evaluating performance of prestressed concrete (PC) bridge girders exposed to fire. A finite element based numerical model for tracing the response of fire exposed T girders is developed in ANSYS. The analysis is carried out in three stages, namely, fire temperature calculation, cross sectional temperature evaluation, and then strength, deformation and effective prestress analysis on girders exposed to elevated temperatures. The applicability of the computer program in tracing the response of PC bridge girders from the initial preloading stage to failure stage, due to combined effects of fire and structure loading, is demonstrated through a case study, and validated by test data of a scaled PC box girder under ISO834 fire condition. Results from the case study show that fire severity has a significant influence on the fire resistance of PC T girders and hydrocarbon fire is most dangerous for the girder. The prestress loss caused by elevated temperature is about 10% under hydrocarbon fire till the girder failure, which can lead to the increase in deflection of the PC girder. The rate of deflection failure criterion is suggested to determine the failure of PC T girder under fire.

Analysis of the 'Structure' of an Elementary School Teacher's Practical Knowledge on Science Experiment Lessons (과학 실험 수업에 관한 한 초등학교 교사의 실천적 지식의 '구조' 분석)

  • Cho, Young-Mi;Oh, Phil-Seok
    • Journal of Korean Elementary Science Education
    • /
    • v.30 no.2
    • /
    • pp.162-177
    • /
    • 2011
  • The purpose of this qualitative case study was to investigate the 'structure' of an elementary school teacher's practical knowledge concerning science experiment lessons. A female elementary teacher in the early career years participated in the study, and video recordings of her science experiment lessons as well as audio-taped interviews with her were analyzed by means of Elbaz's framework. The teacher expressed six images of science experiment lessons: 'Science is difficult', 'Experiments are dangerous', 'Experiments are accurate', 'A science experiment takes a long time', 'Science experiments are interesting', and 'Children are little scientists.' These images were supported by several principles and rules, most of which were clearly described. Among the images, principles, and rules, there were complex relationships with some working in synergy and some conflicting. In case of the image 'Children are little scientists', its subordinate principles and rules were not fully realized in the classroom. Implications for science teaching reform and science education research were discussed.

Fault tolerant design of a Servo Manipulator System for Hot Cell Operation (핫셀용 서보 매니퓰레이터 시스템의 내고장 설계)

  • Jin, Jae-Hyun;Park, Byung-Suk;Ahn, Sung-Ho;Yoon, Ji-Sup;Jung, Jae-Hoo
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1464-1469
    • /
    • 2003
  • In this paper, fault tolerant mechanisms are presented for a servo manipulator system designed to operate in a hot cell. A hot cell is a sealed and shielded room to handle radioactive materials, and it is dangerous for people to work in the hot cell. So, remote operations are necessary to handle the radioactive materials in the hot cell. KAERI has developed a servo manipulator system to perform such remote operations. However, since electric components such as servo motors are weakened with radiation, fault tolerant mechanisms have to be considered. For fault tolerance of the servo manipulator system, hardware and software redundancy has been considered. In the case of hardware, radioactive resistant electric components such as cables and connectors have been adopted and motors driving a transport have been duplicated. In case of software, a reconfiguration algorithm accommodating one motor's failure has been developed. The algorithm uses redundant axes to recover the end effector's motion in spite of one motor's failure.

  • PDF

A Case Study on Cut Slope Failure due to the Geomorphological Factor (지형요인에 의한 절토사면 붕괴사례)

  • Kim, Seung-Hyun;Choi, Ji-Yong;Rhee, Jong-Hyun;Lee, Jung-Yup;Koo, Ho-Bon
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.1161-1170
    • /
    • 2009
  • The Roads in Gangwon Province generally was made on purpose to use the military road. In case of these roads, tremendous dangerous cut slopes do exist and its road linear shape was badly designed. In order to make up for this situation, the government has continuously established the new road or performed the public works such as the straight line of the curved road. Soksil 2 cut slope was made through the road improvement work. This has small surface failures and collapses. In spite of dry season, this slope are leaking lots of groundwater at the unbelievable point. So as to get curious phenomenon right, we performed a detailed field investigation, the geomorphological analysis, the stability analysis considering field characteristic and ultimately proposed the countermeasure to make sure stability of Sokil 2 cut slope.

  • PDF

A Study Of Case On Prescription Of Spring Out Water In Cut Slope (절취사면 용출수의 효율적인 배제에 대한 사례연구)

  • Shin, Chang-Gun;Seo, Jeong-Yoo;Hong, Nam-Kyeong
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.1095-1099
    • /
    • 2009
  • In general, slope failures are occurred by the interaction among various factors(slope shape, hydraulic condition, and geologic condition, etc.). Hydraulic condition was a very important factor of a stability in cut slope and a dangerous of road passing. In this study, two cut-slope case on prescription of spring out water present. And this study data is used at practical affairs.

  • PDF

The Assessment of the Risk Index of Live-line Works on Distribution Line by the Accident Analysis (재해분석을 통한 배전선로 활선작업 공종별 위험지수 평가)

  • Choi, Seung-Dong;Hyun, So-Young;Han, Hyeong-Ju;Shin, Woon-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.3
    • /
    • pp.8-14
    • /
    • 2011
  • The live-line works are very dangerous because of direct contacts with the distribution line or neighboring contacts. So the purpose of this study is to identify the risk factor by accident occurrence form and accident case analysis, and to suggest the quantified risk index by risk occurrence frequency and risk strength analysis. And the risk index assessment is researched by accident cases analysis on work type. Accident cases of transmission distribution line are researched based on data of the Ministry of Employment and Labor in the last ten-year period (2000~2009). In results of this paper, high risk isn't always a priority of safety measures. Risk occurrence frequency and risk strength have to be considered according to detail work types, work methods and conditions of field work. And safety management measures must be planned according to risk occurrence frequency and risk strength.

A Design Methodology for the Temporary Isolation Room Based on the MERS-Cov Infection Control Guideline - In Case of Temporary Negative Pressure Isolation Room Using Shipping Container - (메르스 감염관리지침에 따른 감염병 임시 격리병동 계획방법에 관한 연구 - 컨테이너를 이용한 음압격리병동을 중심으로 -)

  • Lee, Sang-Hyun;Lee, Jin-Woo
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.33 no.12
    • /
    • pp.19-28
    • /
    • 2017
  • The purpose of this study is to propose a design methodology to build temporary isolation rooms when infectious diseases suddenly occur in a certain region, such as the case of MERS-Cov in South Korea in 2015. Although most big hospitals usually have isolation rooms, they are expensive and dangerous to run such facilities on normal and typical days. To deal with these problems in this research, shipping containers are chosen as devices used to build the temporary isolation rooms near the original hospital. To do so, firstly, a prototype for the temporary isolation room was designed with the three part modules. The first part is for the medical team; the second part including the isolation rooms is for patients; the third part is for medical selection rooms to test the specimens. Secondly, the plan was compared with the MERS-Cov infection control guidelines. Finally this prototype is applied into the Yong-in Yon-sei severance hospital and then evaluated through a CFD simulation using STAR-CCM+(ver.9.06) for checking infectious bacterium movement in this prototype. The result showed that the prototype is effectively safe for patients tested as negative, patients waiting to be tested, and the medical team.

A Study on a Safety Life Cycle of IEC 61508 for Functional Safety (기능안전을 위한 IEC 61508의 안전수명주기에 관한 연구)

  • Kim, Sung Kyu;Kim, Yong Soo
    • Journal of Applied Reliability
    • /
    • v.14 no.1
    • /
    • pp.81-91
    • /
    • 2014
  • The IEC 61508 standard was established to specify the functional safety of E/E/PE safety-related systems. Safety life cycle to provide the framework and direction for the application of IEC 61508 is included in this standard. In this paper, we describe overviews, objects, scopes, requirements and activities of each phase in safety life cycle. In addition, we introduce safety integrity level(SIL) which is used for verifying the safety integrity requirements of E/E/PE system and perform a case study to estimate hardware SIL by FMEDA. The SIL is evaluated by two criteria. One of them is the architectural constraints which restrict the maximum SIL by combination of SFF and HFT. The other is the probability of failure which is classified into PFD and PFH based on frequency of demand and calculated by safe or dangerous failure rates.

Clinical Application of Pulmonary Vein Wedge Angiography (Pulmonary Vein Wedge Angiography 의 임상적 이용)

  • 문경훈
    • Journal of Chest Surgery
    • /
    • v.20 no.3
    • /
    • pp.544-547
    • /
    • 1987
  • Pulmonary vein wedge angiography was applied to two patients of 2 years old TOF with PFO. Left pulmonary artery was not visualized by standard right ventriculogram and catheter was not entered into main pulmonary artery. Through PFO and left atrium, pulmonary vein wedge angiography at left lower pulmonary vein was done. The ipsilateral pulmonary artery & its trees in both cases and the contralateral pulmonary artery in one case were well visualized. Dangerous complication, such as massive bronchoconstriction due to extravasation of contrast material into the bronchus, was not developed. Mild coughing was occurred, but well tolerable in both cases. We recommended a dose of 0.8 mL/Kg of contrast material at a rate of 2 to 3 mL/sec and 1 to 2 mL/Kg of flush solution at the same rate by the hand, and routine use of pulmonary vein wedge angiography in cyanotic patients whose pulmonary artery was not visualized by the standard angiography.

  • PDF