• Title/Summary/Keyword: Damage Signal

Search Result 615, Processing Time 0.027 seconds

Study on the application of antenna method for the criterion test of insulator arc resistance (절연체의 내아크성 평가를 위한 안테나 기법의 적용에 관한 연구)

  • Lee, K.W.;Kim, M.Y.;Kang, S.H.;Lim, K.J.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.05b
    • /
    • pp.57-60
    • /
    • 2004
  • Electrical arc is the final stage of insulation breakdown and has high current density which cause heat and light in insulator. Insulator under electrical arc lost its insulating strength and eternal damages. Conventional criterion of electrical arc resistance in Standards have depended on the change of sound pressure and light color after damages on insulator by electrical arc. The recognition of these changes is done by human himself which was very subjective and resulted in some error to judge whether insulator has damages or not. This paper has shown that antenna method is the appropriate measure to judge electrical arc resistance for insulator. Antenna measures the electromagnetic waves radiated from tungsten electrodes with 6mm gap regulated by KSC2130. Applied voltage cross two tungsten electrodes have two different methods such as 1/8 10 and continuous 10mA. Signal amplitudes obtained by antenna has diminished after the damage of insulator, which will provide objective and good way to judge the electrical arc resistance.

  • PDF

Interference Effects on the Thickness of a Pulse Pressure Sensor Array Coated with Silicone (맥 센서 어레이(array)의 실리콘(silicone) 코팅 두께에 따른 센서 간 간섭효과)

  • Jun, Min-Ho;Jeon, Young Ju;Kim, Young-Min
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.1
    • /
    • pp.35-40
    • /
    • 2016
  • Pulse diagnosis is one of the representative diagnostic methods in Oriental medicine. In this study, a pulse pressure sensor array coated with silicone, which includes 6 piezo-resistive sensors and 1 thermistor, is fabricated for pulse measurement. It is necessary to coat the pulse sensor array with silicone to avoid the fracture or damage of pressure sensors when the sensor is in contact with the skin and a constant pressure is applied. However, the silicone coating on the pulse sensor array can cause signal interference among the sensors in the pulse sensor array. The interference number (IN), a calculation for expressing the degree of interference among channels, is changed according to the silicone thickness on the pulse sensor array. The IN is increased by a thick silicone coating, but the fabrication error, an important index for the mass production of the sensor array, is reduced by the thickness of the silicone coating. We propose that the thickness of the silicone on the pulse sensor array is an important consideration for the performance of the fabricated sensor and manufacturing repeatability.

Nitric Oxide-induced Protein S-nitrosylation Causes Mitochondrial Dysfunction and Accelerates Post-ovulatory Aging of Oocytes in Cattle

  • Niu, Ying-Jie;Zhou, Dongjie;Zhou, Wenjun;Nie, Zheng-Wen;Kim, Ju-Yeon;Oh, YoungJin;Lee, So-Rim;Cui, Xiang-Shun
    • Journal of Animal Reproduction and Biotechnology
    • /
    • v.35 no.1
    • /
    • pp.102-111
    • /
    • 2020
  • Nitric oxide (NO)-induced protein S-nitrosylation triggers mitochondrial dysfunction and was related to cell senescence. However, the exact mechanism of these damages is not clear. In the present study, to investigate the relationship between in vitro aging and NO-induced protein S-nitrosylation, oocytes were treated with sodium nitroprusside dihydrate (SNP), and the resultant S-nitrosylated proteins were detected through biotin-switch assay. The results showed that levels of protein S-nitroso thiols (SNO)s and expression of S-nitrosoglutathione reductase (GSNOR) increased, while activity and function of mitochondria were impaired during oocyte aging. Addition of SNP, a NO donor, to the oocyte culture led to accelerated oocyte aging, increased mitochondrial dysfunction and damage, apoptosis, ATP deficiency, and enhanced ROS production. These results suggested that the increased NO signal during oocyte aging in vitro, accelerated oocyte degradation due to increased protein S-nitrosylation, and ROS-related redox signaling.

Effects of Yangkyuksanhawtang on the Allergic Contact Dermatitis (양격산화탕(凉隔散化湯)이 Allergy성(性) 접촉피부염(接觸皮膚炎)에 미치는 영향(影響))

  • Cho, Se-Wang
    • Korean Journal of Korean Medical Institute of Dermatology and Aesthetics
    • /
    • v.1 no.1
    • /
    • pp.16-40
    • /
    • 2005
  • Objective : To study the effectiveness of Yangkyuksanhawtang against Allergic Contact Dermatitis I observed the change of cutaneous shape, histochemistry, immunohistochemistry, and the distribution of apoptotic cells. materials and methods : I divided 4-month-old rats into three groups of 10, which are a contrastive group of having applied Acetone olive oil only, ACD group to have intentionally activated Allergic Contact Dermatitis by DNCB and YST group to give medication of Yangkyuksanhawtang extract. And I observed each group of mice after 24, 48 and 72 hours. results : 1. With the result of Contact hypersensitivity assay, YST group shows appreciably less ear swelling than ACD group. 2. Comparing YST and ACD groups to each other regarding general change of skin, YST group shows less hyperplasia of epidermis, less migration of inflammatory cells and less damage of epidermis than ACD group. 3. Regarding the change of collagen fiber, ACD group has appeared to be low in number of collagen fiber while YST shows similarity with the contrastive group. 4. In dermis YST group has showed lower number of mastocyte than ACD group and is granulated type. 5. In dermis YST group has showed less MAC-1, IL-1 , $IL-2R-\;{\alpha}$ G, ICAM-1 and VCAM-1 than ACD group. 6. The distribution of apoptotic cells has appeared littler in YST group than in ACD 7. Among signal molecule of apoptosis Bcl-2 has distributed more in YST group than ACD group and Bax and Fas has distributed less in YST group than ACD group.

  • PDF

A Hybrid Anti-islanding Detection Scheme for Utility Interactive Inverter with Enhanced Harmonic Extraction Capability (향상된 고조파 검출 능력을 갖는 계통연계 인버터의 하이브리드 단독운전 방지기법)

  • Kang, Sung-Wook;Kim, Kyeong-Hwa
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.4
    • /
    • pp.312-319
    • /
    • 2014
  • When distributed generation such as a wind power system is connected to the grid, it should meet grid requirements like IEEE Std. 1547, which regulates the anti-islanding method. Since the islanding may cause damage on electrical equipments or safety hazards for utility line worker, a distributed generation should detect it as soon as possible. This paper proposes a hybrid anti-islanding method coupled with the active and passive detection methods. To enhance the harmonic extraction capability for an active harmonic injection method, cascaded second-order band-pass filter and signal processing scheme are employed. Simulation and experiments are carried out under the islanding test condition specified in IEEE Std. 1547. Passive over/under voltage and over/under frequency methods are combined with the active method to improve the detection speed under certain condition. The simulation and experimental results are presented to verify that the proposed hybrid anti-islanding method can effectively detect the islanding.

Constant Current & Constant Voltage Battery Charger Using Buck Converter (벅 컨버터를 이용한 정전류 정전압 배터리 충전기)

  • Awasthi, Prakash;Kang, Seong-Gu;Kim, Jeong-Hun;Park, Sung-Jun
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.399-400
    • /
    • 2012
  • The proposed battery charger presented in this paper is suitable for Lead-Acid Battery and the dc/dc buck converter topology is applied as a charger circuit. The technique adopted in this charger is constant current & constant voltage dual mode, which is decided by the value of voltage of proposed battery. Automatic mode change function is detected by the percentage value of level of battery charging. CC Mode (Constant Current Mode) is operated when charging level is below 80% of the total charging of Battery voltage and above 80% of battery voltage charging, CV Mode (Constant Voltage Mode) is automatically operated. As the charging level exceeds 120%, it automatically terminates charging. The feedback signal to the PWM generator for charging the battery is controlled by using the current and voltage measurement circuits simultaneously. This technique will degrade the damage of proposed type of battery and improve the power efficiency of charger. Finally, a prototype charger circuit designed for a 12-V 7-Ah lead acid battery is constructed and tested to confirm the theoretical predictions. Satisfactory performance is obtained from simulation and the experimental results.

  • PDF

A Study on Estimation of Breakdown Location using UHF Sensors for Gas Insulated Transmission Lines (UHF센서를 이용한 가스절연송전선로 절연파괴 위치 추정에 관한 연구)

  • Park, Hung-Sok;Han, Sang-Ok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.4
    • /
    • pp.805-810
    • /
    • 2011
  • This paper deals with the method and algorithm used to find fault locations in gas insulated transmission line. The method uses UHF sensors and digital oscilloscope to detect discharge signals emitted to the outside through insulating spacer in the event of breakdown inside GIL. UHF sensors are the external type and installed at outside of insulating spacers of GIL. And we used wavelet signal processing to analyze the discharge signals and confirm the exact fault location findings in the GIL test line. This method can overcome demerit of TDR(Time Domain Reflectometer) method having been applied to detect fault location for conventional underground transmission lines, and Ground Fault Sensors used in conventional GIS systems. TDR method requires high level of specialty and experience in analyzing the measured signals. Ground fault sensors are installed inside GIL and can be destroyed by high transient voltage. This paper's method can simplify the fault location process and minimize the damage of sensors. In addition, this method can estimate the fault location only by the time difference when discharge signals are arrived to detecting sensors at the ends of GIL sections without reasons of breakdown. To test the performance of our method, we installed sensors at the ends of test line of GIL(84m) and sensed discharge signals occurred in GIL, energized with AC voltage generator up to 700kV.

Cytoprotective Activity of Carpinus tschonoskii against H$_2$O$_2$ Induced Oxidative Stress

  • Zhang, Rui;Kang, Kyoung-Ah;Piao, Mei-Jing;Park, Jae-Woo;Shin, Taek-Yun;Yoo, Byoung-Sam;Yang, Young-Taek;Hyun, Jin-Won
    • Natural Product Sciences
    • /
    • v.13 no.2
    • /
    • pp.118-122
    • /
    • 2007
  • We have studied the cytoprotective effect on H$_2$O$_2$ induced oxidative stress from leaves of Carpinus tschonoskii. The methanol extract of Carpinus tschonoskii was found to scavenge intracellular reactive oxygen species (ROS) using flow cytometry and confocal microscope. This extract prevented lipid peroxidation and thus reduced cell death of Chinese hamster lung fibroblast (V79-4) induced by H$_2$O$_2$ treatment. The extract increased catalase activity and phosphorylation of extracellular signal regulated kinase (ERK). Taken together, the results suggest that Carpinus tschonoskii protects V79-4 cells against oxidative damage by H$_2$O$_2$ through scavenging ROS.

Function of NADPH Oxidases in Diabetic Nephropathy and Development of Nox Inhibitors

  • Lee, Sae Rom;An, Eun Jung;Kim, Jaesang;Bae, Yun Soo
    • Biomolecules & Therapeutics
    • /
    • v.28 no.1
    • /
    • pp.25-33
    • /
    • 2020
  • Several recent studies have reported that reactive oxygen species (ROS), superoxide anion and hydrogen peroxide (H2O2), play important roles in various cellular signaling networks. NADPH oxidase (Nox) isozymes have been shown to mediate receptor-mediated ROS generation for physiological signaling processes involved in cell growth, differentiation, apoptosis, and fibrosis. Detectable intracellular levels of ROS can be induced by the electron leakage from mitochondrial respiratory chain as well as by activation of cytochrome p450, glucose oxidase and xanthine oxidase, leading to oxidative stress. The up-regulation and the hyper-activation of NADPH oxidases (Nox) also likely contribute to oxidative stress in pathophysiologic stages. Elevation of the renal ROS level through hyperglycemia-mediated Nox activation results in the oxidative stress which induces a damage to kidney tissues, causing to diabetic nephropathy (DN). Nox inhibitors are currently being developed as the therapeutics of DN. In this review, we summarize Nox-mediated ROS generation and development of Nox inhibitors for therapeutics of DN treatment.

A Study on the Fault Detection of Auto-transmission according to Gear Damage (기어손상에 따른 자동변속기의 결함 검출에 관한 연구)

  • Park, Ki-Ho;Jung, Sang-Jin;Wee, Hyuk;Kim, Jin-Seong;Han, Kwan-Su;Kim, Min-Ho
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.1
    • /
    • pp.47-56
    • /
    • 2008
  • This paper presents a detecting technique for the improvement in quality by appling the various vibrational characteristics theory. The object of this study is to objectively point out faulty gear by developing the program which can be used to analyze and predict the vibrational characteristics caused by gear wear, deformation and nick of auto-transmission. The fault detection methods by vibrational signal analysis of gear have been progressed in the various fields of industry. These methods have the advantage of being easy to attach the accelerometer without discontinuance of the structure. But not all the methods are efficient for finding early faults. So in the thesis, we completed development of the inspection system of vibration by appling the most efficient detecting methods and verified the system's reliability through experiments.