• Title/Summary/Keyword: Daegu subway fire accident

Search Result 18, Processing Time 0.022 seconds

Analysis of Injury Types in Korean Disaster (우리나라 인적재해 유형별 손상 분석)

  • Shin, Dong-Min;Lee, In-Soo;Baek, Mi-Lye
    • The Korean Journal of Emergency Medical Services
    • /
    • v.8 no.1
    • /
    • pp.179-187
    • /
    • 2004
  • The purpose of the study was to injury types in Daegu subway fire accident, Sampung department store collapse, Mokpo airport civil aircraft accident, and Buan sunken ship disaster. The conclusion obtained from these analyses are as following. 1. The total of victims were Sampung department store collapse(l440 people). Buan sunken ship disaster(355 people), Daegu subway fire accident(340 people), and Mokpo airport civil aircraft accident(110 people). 2. The total of dead people were Sampung department store collapse(502 people), Buan sunken ship disaster(287 people), Daegu subway fire accident(192 people), and Mokpa airport civil aircraft accident(66 people). 3. The total of injured people were Sampung department store collapse(938 people), Daegu subway fire accident(148 people), Mokpo airport civil aircraft accident(84 people), and Buan sunken ship disaster(67 people). 4. The major types of victims presented smoke inhalation such as coughing, dyspnea, and sore throat in Daegu subway fire accident. 5. The major types of victims presented crushing(multiple fractures), vertebral, and soft tissues injuries in Sampung department store collapse. 6. The major types of victims presented multiple fractures. In addition to, a lot of people showed vertebral injuries and shock symptoms in Mokpo airport civil aircraft accident. 7. The major types of victims presented drowning as well lots of hypothermia patients in Buan sunken ship disaster. There were a wide variety of types in human disaster. Therefore, the most important disaster training program need to each disaster aspect in the local emergency medical services system. Moreover, the emergency medical services personnel should be understand and training for injury types of each human disaster.

  • PDF

A Study on the Resident's Understanding Analysis of Fire Disaster and the Fluctuation Modeling of Disaster Prevention Caused by Daegu Subway Accident (대구 지하철 사고에 따른 화재 의식조사 및 방재의식 변동모형에 관한 연구)

  • 이상호;이재복
    • Fire Science and Engineering
    • /
    • v.17 no.3
    • /
    • pp.45-49
    • /
    • 2003
  • The resident's understanding of subway fire disaster broken out in Daegu city, February 2002, was analyzed using netizen's opinion on Internet Web Site. Based on the data of the resident's understanding, fluctuation curve for disaster prevention was modeled to assess quantitative consciousness. Our research will be useful to maintain continuous understanding for disaster protection.

Psychiatric Characteristics of Wounded Persons of Daegu Subway Fire Accident after Six Years (대구시 지하철 화재사고 부상자들의 6년후 정신과적 특성)

  • Ha, Sook-Sin;Suh, Soon-Rin;Kim, Jung-Bum;Lee, Eun-Jeong
    • Anxiety and mood
    • /
    • v.5 no.2
    • /
    • pp.125-132
    • /
    • 2009
  • Objective : This study examined psychiatric characteristics of wounded persons of Daegu subway fire accident occurring in February 2003 after six years. Methods : 103 wounded persons completed psychometric measures at 2 months and 6 years after the accident. Changes of psychiatric symptoms were compared and factors affecting post-traumatic stress disorder (PTSD) seriousness were examined. Results : In Minnesota Multiphasic Personality Inventory, the scores of Psychopathic Deviate (Pd), Masculinity/ Femininity (Mf), Social Introversion (Si) scales were significantly changed over time. The scores of Symptoms Checklist-90-Revision subscales were mostly decreased over time, however, paranoid ideation (PAR) subsclae scores were not significantly changed over time. In all of the State-Trait Anxiety Inventory (STAI)-State, Beck Depression Inventory, Impact of Event Scale, and PTSD Checklist-Civilian, mean scores at 6 years after the accident were significantly lower than those at 2 months after the accident. However, STAI-Trait score was not significantly changed over time. Total seriousness of PTSD was found to be affected by quality of sleep. Conclusions : Psychiatric symptoms of subjects were largely improved over time, but distrust and doubt of others were continued. In addition, the wounded persons suffered from sleep problems. Therefore, early and continuous interventions of public institutions and public health specialists are needed for the wounded persons with chronic psychiatric disorders.

  • PDF

A Study on the Recognition of Daegu Citizen on Fire Safety (대구시민의 소방안전의식에 관한 연구)

  • 방창훈;최영상
    • Fire Science and Engineering
    • /
    • v.18 no.3
    • /
    • pp.25-29
    • /
    • 2004
  • The purpose of this study is to supply basis data that can improve the recognition of Daegu citizens on fire safety through the investigation of their recognition on fire safety. To achieve the purpose, 553 Daegu citizens in Daegu city were interviewed from Oct. 2 to 15, 2003. The results of this study are as follows; Citizens had thought little the recognition of our society on fire safety and Daegu subway fire accident caused very big effect in citizens' fire safety recognition. Citizens did not trust about fire fighting facilities that is established in the building. Method to elevate recognition for citizens' fire safety recognition appeared by TV, newspaper, etc public information reinforcement (30.7%), establishment and operation of the fire safety experience center (24.6%), fire safety education reinforcement in school (20.8%).

Evaluation of the Appropriateness of Smoke Control Conditions of Platform at the Subway Fire by using FDS (FDS를 이용한 지하철 객실 화재 시 승강장 제연조건의 적정성 평가)

  • Kim, Ki-Sung;Song, Dong-Woo;Lee, Su-Kyung
    • Fire Science and Engineering
    • /
    • v.27 no.5
    • /
    • pp.8-14
    • /
    • 2013
  • In the subway, various fires continue to take place across the world. In the Daegu subway accident in 2003, many people were damaged by shortened visibility range caused by toxic gas and smoke. This paper, assuming that a subway fire happens in the Mandeok Station of the subway system in Busan, analyzed different smoke-spreading situations depending on the ventilation situation at its platform (opening of the train doors, operation of ventilation facilities in the tunnel, and working of fire door), using FDS. The calculation proved that it would be more effective to secure evacuation route when the ventilation facilities of the tunnel are not operated, than when they are on. And, it was also found that the case where the doors of the platform to the escape route and only the platform-facing doors of the subway car on fire office are open would be more effective to ventilation than the case where all the doors are open. And, it was found to be important that the fire doors of the platform are working properly.

Simplified Evaluation Method for Residual Bond Strength of Reinforced Concrete Using Standard Fire Curve (표준화재곡선을 이용한 잔존부착강도 평가 간략방법 제안)

  • Moon, Do-Young
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.5
    • /
    • pp.41-47
    • /
    • 2010
  • For the enhancement of structural safety of thermally damaged reinforced concrete structure, rapid evaluation of damage in the structure is very important. This study addresses a simplified method which is equivalent to the standard fire curve (ISO 834) for the residual bond strength evaluation. In the proposed method, a exposure duration as well as the maximum temperature can be considered. For the comparisons with conventional methods, concrete properties obtained from the report of Daegu subway fire accident were referred and the results support the applicability of the proposed method in this study.

The Study of Installing Platform Screen Doors (PSD) by using SWOT Analysis (SWOT 분석을 통한 스크린도어 설치에 대한 연구 - 수도권 전철을 중심으로 -)

  • Park, Min-Seo;Koh, Sung-Won;Koo, Ja-Kyung;Lee, Tai-Sik
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.1587-1593
    • /
    • 2008
  • After the incendiary fire accident at Daegu subway, discussion of PSD installation started to prevent accident from fall. safety accident and big accident. Following these paradigm, the purpose of the study is to analyze the present condition of current installation of PSD in our country and suggest an improvement scheme for the future PSD operation extension. Using the SWOT analysis and we analyze the inner and outer capability of PSD installation. We try to find a counter plan strategy for PSD installation improvement scheme through the analysis.

  • PDF

A Case Study on Intelligent Surveillance System for Urban Transit Environment (도시철도 환경에서 지능형 감시 시스템 구축 사례)

  • Chang, Il-Sik;An, Tae-Ki;Cho, Byeong-Mok;Park, Goo-Man
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.1722-1728
    • /
    • 2011
  • The security issue in urban transit system has been widely considered as the common matters after the fire accident at Daegu subway station. The safe urban transit system is highly demanded because of the vast number of daily passengers, and it is one of the most challenging projects. We introduced a test model for integrated security system for urban transit system and built it at a subway station to demonstrate its performance. This system consists of cameras, sensor network and central monitoring software. We described the smart camera functionality in more detail. The proposed smart camera includes the moving objects recognition module, video analytics, video encoder and server module that transmits video and audio information.

  • PDF

A Study on the suitable Underground space for Safety against Terror (테러안전을 위한 지하공간의 예방대책)

  • Kwon, Jeong-hoon;Park, Ok-cheol;Kim, Tae-hwan
    • Journal of the Society of Disaster Information
    • /
    • v.4 no.1
    • /
    • pp.34-52
    • /
    • 2008
  • The result of all terrors causes enormous damage. In order to prevent this damage in advance and find a prompt provision after terror, we investigated a safety measure against terror on the assumption that the fire in Daegu central subway is a subway terror. The followings are the safety measures against terror based on an underground space. Frist, training systems have to be established to provide against a terror. Second, People's consciousness about safety from a terror, centering on early education, has to be raised. Third, the provisions related with underground tunnel have to be established so that people can take shelter in underground tunnel areas. Fourth, CCTV has to be established in the guest rooms of the electric motor cars. Last, cooperative systems among related organizations have to be constructed, and the networks of the organizations have to be established so that they can cope with an accident.

  • PDF