L-spine Bone SPECT/CT에서 획득된 저선량 CT 영상을 이용한 용적 골밀도 결과의 유용성 (Usefulness of volumetric BMD measurement by using low dose CT image acquired on L-spine Bone SPECT/CT)

  • 고현수;박순기;김은혜;최종숙;정우영;이동윤
    • 핵의학기술
    • /
    • 제27권2호
    • /
    • pp.99-109
    • /
    • 2023
  • Purpose: CT scan makes up for the weak point of the nuclear medicine image having a low resolution and also were used for attenuation correction on image reconstruction. Recently, many studies try to make use of CT images additionally, one of them is to measure the bone mineral density(BMD) using Quantitative CT(QCT) software. BMD exams are performed to scan lumbar and femur with DXA(Dual-Energy X-Ray Absorptiometry) in order to diagnose bone disease such as osteopenia, osteoporosis. The purpose of this study is to identify the usefulness of QCT_BMD analyzed with low dose CT images on L-spine Bone SPECT/CT comparing with DXA_BMD. Materials and Methods: Fifty five women over 50 years old (mean 66.4 ± 9.1) who took the both examinations(L-spine Bone SPECT/CT with SIEMENS Intevo 16 and DXA scan with GE Lunar prodigy advance) within 90 days from April 2017 to July 2022, BMD, T-score and disease classification were analyzed. Three-dimensional BMD was analyzed with low dose CT images acquired on L-spine Bone SPECT/CT scan on Mindways QCT PROTM software and two-dimensional BMD was analyzed on DXA scan. Basically, Lumbar 1-4 were analyzed and the patients who has lesion or spine implants on L-spine were excluded for this study. Pearson's correlation analysis was performed in BMD and T-score, chi-square test was performed in disease classification between QCT and DXA. Results: On 55 patients, the minimum of QCT_BMD was 18.10, maximum was 166.50, average was 82.71 ± 31.5 mg/cm3. And the minimum of DXA-BMD was 0.540, maximum was 1.302, average was 0.902 ± 0.201 g/cm2, respectively. The result shows a strong statistical correlation between QCT_BMD and DXA_BMD(p<0.001, r=0.76). The minimum of QCT_T-score was -5.7, maximum was -0.1, average was -3.2 ± 1.3 and the minimum of DXA_T-score was -5.0, maximum was 1.7, average was -2.0 ± 1.3, respectively. The result shows a statistical correlation between QCT T-score and DXA T-score (p<0.001, r=0.66). On the disease classification, normal was 5, osteopenia was 25, osteoporosis was 25 in QCT and normal was 10, osteopenia was 25, osteoporosis was 20 in DXA. There was under-estimation of bone decrease relatively on DXA than QCT, but there was no significant differences statistically by chi-square test between QCT and DXA. Conclusion: Through this study, we could identify that the QCT measurement with low dose CT images QCT from L-Spine Bone SPECT/CT was reliable because of a strong statistical correlation between QCT_BMD and DXA_BMD. Bone SPECT/CT scan can provide three-dimensional information also BMD measurement with CT images. In the future, rather than various exams such as CT, BMD, Bone scan are performed, it will be possible to provide multipurpose information via only SPECT/CT scan. In addition, it will be very helpful clinically in the sense that we can provide a diagnosis of potential osteoporosis, especially in middle-aged patients.

부분골밀도 측정을 통해 산출되는 체지방률의 임상적 유용성에 대한 평가 (The Clinical Usefulness Measurement of the Whole Body Percent Fat Calculated by the Part Bone Mineral Density Measurement)

  • 강영은;김은혜;김호성;최종숙;최우준
    • 핵의학기술
    • /
    • 제15권1호
    • /
    • pp.3-9
    • /
    • 2011
  • 이중에너지 방사선 흡수계측법(Dual-energy X-ray Apsorptiometry, DXA)은 일반적으로 골밀도를 통한 골다공증 평가 및 치료목적으로 이용되어 왔으며 최근 비만에 대한 관심이 높아지면서 체지방검사 처방이 증가하고 있는 추세이다. 기존의 체지방 측정은 전신을 검사해야만 평가가 가능했지만 근래 DXA장비의 소프트웨어가 향상 되면서 요추와 대퇴부의 측정만으로도 전신체지방률을 추측 할 수 있게 되었다. 전신측정이 아닌 부분측정 값이 다른 검사방법으로 산출된 값과 비교하여 타당성을 갖는지 생체전기저항측정법(Bioelectrical Impedence Analysis, BIA)과 체질량 지수(Body Mass Index, BMI)와의 상관도 분석을 통해 알아보고자 한다. 2010년 3월부터 8월까지 본원 건강검진센터에 내원한 수검자 중 40세 이상의 여성 90명을 대상으로 DXA와 BIA를 통해 체지방률을 측정하였다. BMI는 신체 계측기를 통해 측정된 신장과 체중을 수검자 정보에 기입하여 자동으로 산출되는 값을 활용하였다. 또한 체중에 따른 차이가 있는지 알아보기 위해 BMI를 기준으로 저체중, 정상, 비만의 세 그룹으로 분류하여 각 그룹에서 BMI와 BIA, DXA 간의 상관도를 분석하였다. 저체중과 정상, 비만으로 나눈 세 그룹에서의 DXA와 BIA의 비교는 모든 그룹에서 통계적으로 유의한 차이를 보이지 않았다. 그룹으로 나누지 않은 상태에서의 상관분석결과 DXA로 측정된 체지방률은 BMI와 비교해 통계적으로 유의한 높은 상관관계를 나타냈으며(r=0.908, p<0.01) BIA와의 비교에서도 통계적으로 유의한 높은 상관관계를 보였다(r=0.927, p<0.01). 부분 골밀도 측정으로부터 추정된 전신체지방률이 BIA 그리고 BMI와 비교해 뛰어난 상관관계를 보여 정보의 신뢰도가 높다는 것을 확인하였다. 아직 추정된 전신체지방률에 관한 명확한 기준이 없어 골밀도측정만으로 체지방평가를 하기는 어렵다. 그러나 골밀도검사를 통해 골다공증의 진단은 물론 체지방에 관한 정보까지 얻을 수 있다는 점에서 매우 효율적이며 추후 전신골밀도검사로 측정된 체지방률과의 비교연구를 통해 더 객관적이고 임상적으로 유용한 정보 제공이 가능할 것으로 판단된다.

  • PDF

Application of an Energy Sensitive CZT Detector to a DXA Type of Bone Densitometer

  • Yoon, Je-Woong;Lee, Hyung-Koo;Lee, Heung-Kyu
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.422-424
    • /
    • 2002
  • The accuracy of DXA(Dual Energy X-ray Absorptiometry) highly depends on the detection and separation capability of dual energy X-ray X-ray photons. In addition both of scan time and patient exposure are affected by detection efficiency. A CZT detector with a good energy resolution and high detection efficiency was evaluated for the application of bone densitometry. Its performance was compared to a photomultiplier tube with a NaI(T1) scintillator in terms of energy resolution, detection efficiency and the accuracy of bone mineral density measurement. The comparison study was performed with CZT detector and PM tube using DXA equipments(OSTEO Plus, OSTEO Prima, ISOL Technology). The energy spectrum was acquired using MCA(Multi-Channel Analyzer). The used X-ray energy ranged from 20keV to 86keV. The MCA result of the CZT detector showed a slightly sharper energy spectrum than that of NaI(T1). Detection efficiency of the CZT detector at 59.5keV was 1.4 times better. Remarkably the final results of bone mineral density measurements demonstrate only less than 1% difference. The CZT detector appears to have many benefits for the application of bone densitometry. Its excellent energy resolution can enhance the counting accuracy of dual energy X-ray spectrum. Furthermore its compactness in physical dimension and no cooling requirement will be additional benefits for a more compact and accurate bone densitometer.

  • PDF

Osteoporosis prediction from the mandible using cone-beam computed tomography

  • Barngkgei, Imad;Haffar, Iyad Al;Khattab, Razan
    • Imaging Science in Dentistry
    • /
    • 제44권4호
    • /
    • pp.263-271
    • /
    • 2014
  • Purpose: This study aimed to evaluate the use of dental cone-beam computed tomography (CBCT) in the diagnosis of osteoporosis among menopausal and postmenopausal women by using only a CBCT viewer program. Materials and Methods: Thirty-eight menopausal and postmenopausal women who underwent dual-energy X-ray absorptiometry (DXA) examination for hip and lumbar vertebrae were scanned using CBCT (field of view: $13cm{\times}15cm;$ voxel size: 0.25 mm). Slices from the body of the mandible as well as the ramus were selected and some CBCT-derived variables, such as radiographic density (RD) as gray values, were calculated as gray values. Pearson's correlation, one-way analysis of variance (ANOVA), and accuracy (sensitivity and specificity) evaluation based on linear and logistic regression were performed to choose the variable that best correlated with the lumbar and femoral neck T-scores. Results: RD of the whole bone area of the mandible was the variable that best correlated with and predicted both the femoral neck and the lumbar vertebrae T-scores; further, Pearson's correlation coefficients were 0.5/0.6 (p value=0.037/0.009). The sensitivity, specificity, and accuracy based on the logistic regression were 50%, 88.9%, and 78.4%, respectively, for the femoral neck, and 46.2%, 91.3%, and 75%, respectively, for the lumbar vertebrae. Conclusion: Lumbar vertebrae and femoral neck osteoporosis can be predicted with high accuracy from the RD value of the body of the mandible by using a CBCT viewer program.

자체 개발한 보조기구로 원위 요골의 골밀도 측정 자세 연구 (Study on Oneself Developed to Apparatus Position of Measurement of BMD in the Distal Radius)

  • 한만석;송재용;이현국;유세종;김용균
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제32권4호
    • /
    • pp.419-426
    • /
    • 2009
  • 연구목적 : 본 연구는 원위 요골의 회전에 따른 투사 단면적의 변화가 골밀도에 미치는 영향이 어느 정도인지 알아보고, 정확한 회전각을 알아보기 위한 보조기구를 개발하는데 있다. 또한 전완부의 골밀도 측정 시정확한 측정 방법을 알아보고자 하였다. 연구방법 : 골밀도 측정시 정확한 측정 자세를 알아보고자 수술, 기형이나 외상력이 없는 20대 남성 20명을 대상으로 하였다. 실험은 세가지로 수행하였다. 첫째, 원위요골 골밀도 측정을 위한 보조기구 제작. 둘째, 원위 요골의 단면 구조 및 수평면에 대한 각도를 파악하기 위하여 CT(Computer Tomography) 스캔을 하였다. 회전 각도는 PACS 모니터 상에서 m-view 프로그램으로 측정하였다. 셋째, 회전에 따른 골밀도의 변화를 알아보기 위하여 20개의 건조 된 사체 표본요골을 DXA로 중립위(0도)를 기준으로 내회전 및 외회전 각각 5, 10도에서 측정하였다. 결 과 : CT 스캔 상 원위요골 단면의 평균 회전 각도는 각각 외회전이 80%(n=16) 7.4도, 내회전이 15%(n=3) 3.3도, 중립 위가 9%(n=1) 1.0도이었다. 20명에 대한 전체 평균 회전각은 외회전 약 5.4도이었다. 건조된 cadaver 연구에서도 각 원위 요골의 회전 각도별 골밀도 값이 서로 달랐고 회전 각도가 최저 골밀도인 경우의 평균 외회전 3.3도 이었다. 결 론 : 원위요골의 골밀도 측정 시에도 20명의 CT영상과 건조된 사체 요골표본에서의 결과와 같이 원위요골의 해부학적 구조상 대부분이 외회전 되어 있어 중립위 보다는 적절한 내회전이 필요하며 약 5도를 추천한다.

  • PDF

중년 남성에서 접골탕 투여 후 개선된 골밀도에 관한 증례 보고 (Improvement of Low Bone Mineral Density Treated with Jeopgol-tang in a Middle-Aged Man: A Case Report)

  • 원지윤;최영진;이병철;이향숙
    • 대한한의학회지
    • /
    • 제42권2호
    • /
    • pp.90-97
    • /
    • 2021
  • DXA로 측정한 요추 부위와 대퇴골경의 골밀도 수치가 2년간 지속적으로 연령대 평균 이하였던 중년의 사무직 남성 환자가 접골탕을 복용하고 골밀도 수치가 개선되었다.

골다공증의 진단과 치료 (The Diagnosis and Treatment of Osteoporosis)

  • 문준성;원규장
    • Journal of Yeungnam Medical Science
    • /
    • 제25권1호
    • /
    • pp.19-30
    • /
    • 2008
  • 골다공증은 골밀도와 골의 질로 구성되는 골의 강도가 손상됨으로 골절의 위험이 높아지는 골격질환이며, 최근 유병율이 점차 증가하고 있는 추세이다. 임상적으로 무증상인 경우가 많으며 방사선학적 검사인 단순 방사선 검사, 골 스캔, CT, MRI 등이 골밀도 및 골절의 진단에 유용하다. 골밀도의 정량적 검사로는 이중에너지 방사선 흡수법, 정량적 전산화 단층촬영이 사용되고 있다. 골다공증의 진단은 WHO 기준에 따라 T-score가 -2.5 이하일 경우 진단할 수 있다. 그 외에 생화학적 골표지자들도 진단에 도움이 된다. 골다공증 치료제는 골흡수억제제와 골형성자극제(formation stimulator)로 나눌 수 있는데 골흡수억제제로는 칼슘, 에스트로겐, 칼시토닌, 비스포스포네이트(bisphosphonate), 비타민 D 등이 있으며 골량을 증가시키는 골형성자극제로는 현재 부갑상선 호르몬이 유일하며 최근 strontium ranelate가 추가되었다. 일일 1200 mg의 칼슘과 800 IU 의 비타민 D 섭취가 권장되고 있으며, 폐경기 여성에서 에스트로겐이 효과가 입증되었고 골다공증으로 인한 통증에는 칼시토닌이 효과가 있다. 비스포스포네이트는 폐경 후 골다공증의 치료, 예방 및 스테로이드에 의한 골다공증 치료에 대해 FDA의 승인을 받았다. 폐경 후 골다공증의 치료, 예방에 사용되는 SERM은 골의 질을 향상시킴으로써 골절을 예방한다고 알려져 있다. 골형성자극제인 부갑상선 호르몬이 골절의 위험을 감소시킨다고 보고된 바 있으며, strontium은 최근에 개발된 약제로 3상 연구에서 골절 위험율 감소효과를 보였으나 더 많은 연구가 필요할 것으로 생각된다.