• Title/Summary/Keyword: DXA Scan

Search Result 7, Processing Time 0.022 seconds

Usefulness of volumetric BMD measurement by using low dose CT image acquired on L-spine Bone SPECT/CT (L-spine Bone SPECT/CT에서 획득된 저선량 CT 영상을 이용한 용적 골밀도 결과의 유용성)

  • Hyunsoo Ko;Soonki Park;Eunhye Kim;Jongsook Choi;Wooyoung Jung;Dongyun Lee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.27 no.2
    • /
    • pp.99-109
    • /
    • 2023
  • Purpose: CT scan makes up for the weak point of the nuclear medicine image having a low resolution and also were used for attenuation correction on image reconstruction. Recently, many studies try to make use of CT images additionally, one of them is to measure the bone mineral density(BMD) using Quantitative CT(QCT) software. BMD exams are performed to scan lumbar and femur with DXA(Dual-Energy X-Ray Absorptiometry) in order to diagnose bone disease such as osteopenia, osteoporosis. The purpose of this study is to identify the usefulness of QCT_BMD analyzed with low dose CT images on L-spine Bone SPECT/CT comparing with DXA_BMD. Materials and Methods: Fifty five women over 50 years old (mean 66.4 ± 9.1) who took the both examinations(L-spine Bone SPECT/CT with SIEMENS Intevo 16 and DXA scan with GE Lunar prodigy advance) within 90 days from April 2017 to July 2022, BMD, T-score and disease classification were analyzed. Three-dimensional BMD was analyzed with low dose CT images acquired on L-spine Bone SPECT/CT scan on Mindways QCT PROTM software and two-dimensional BMD was analyzed on DXA scan. Basically, Lumbar 1-4 were analyzed and the patients who has lesion or spine implants on L-spine were excluded for this study. Pearson's correlation analysis was performed in BMD and T-score, chi-square test was performed in disease classification between QCT and DXA. Results: On 55 patients, the minimum of QCT_BMD was 18.10, maximum was 166.50, average was 82.71 ± 31.5 mg/cm3. And the minimum of DXA-BMD was 0.540, maximum was 1.302, average was 0.902 ± 0.201 g/cm2, respectively. The result shows a strong statistical correlation between QCT_BMD and DXA_BMD(p<0.001, r=0.76). The minimum of QCT_T-score was -5.7, maximum was -0.1, average was -3.2 ± 1.3 and the minimum of DXA_T-score was -5.0, maximum was 1.7, average was -2.0 ± 1.3, respectively. The result shows a statistical correlation between QCT T-score and DXA T-score (p<0.001, r=0.66). On the disease classification, normal was 5, osteopenia was 25, osteoporosis was 25 in QCT and normal was 10, osteopenia was 25, osteoporosis was 20 in DXA. There was under-estimation of bone decrease relatively on DXA than QCT, but there was no significant differences statistically by chi-square test between QCT and DXA. Conclusion: Through this study, we could identify that the QCT measurement with low dose CT images QCT from L-Spine Bone SPECT/CT was reliable because of a strong statistical correlation between QCT_BMD and DXA_BMD. Bone SPECT/CT scan can provide three-dimensional information also BMD measurement with CT images. In the future, rather than various exams such as CT, BMD, Bone scan are performed, it will be possible to provide multipurpose information via only SPECT/CT scan. In addition, it will be very helpful clinically in the sense that we can provide a diagnosis of potential osteoporosis, especially in middle-aged patients.

The Clinical Usefulness Measurement of the Whole Body Percent Fat Calculated by the Part Bone Mineral Density Measurement (부분골밀도 측정을 통해 산출되는 체지방률의 임상적 유용성에 대한 평가)

  • Kang, Young-Eun;Kim, Eun-Hye;Kim, Ho-Sung;Choi, Jong-Sook;Choi, Woo-Jun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.3-9
    • /
    • 2011
  • Purpose: Generally dual energy X-ray absorptiometry has been used for the purpose of evaluation of osteoporosis and treatment. Recently the interest of obesity came to be high and body percent fat test is increasing. Existing measure of body fat have to scan the whole body can be evaluated, but only lumbar spine and hip measurements was assumed to be whole body fat as well as improving the software. It tries to check whether the part measured value not being whole body measurement has the validity or not compared with the value calculated with the method that it is different, it forgives through a correlation with a (BIA) and (BMI). Materials and Methods: In 2010, the body percent fat was measured among the examinee coming to the Asan Medical Center public health care center from March till August against 90 females more than 40 years old through (DXA) and BIA. BMI utilized the value which wrote an hight and weight measured through the body measuring instrument in the examinee information and is automatically calculated. In addition, it classified as the low weight ($13-18.5kg/m^2$), normal ($18.5-25kg/m^2$), and corpulence ($25-30kg/m^2$) based on BMI and so that it could check whether there was the difference according to the weight or not BMI and BIA and correlation between DXA were analyzed in each group. The statistical program for the analysis used SPSS 12.0. Results: The comparison of DXA at 3 which it divides into the low weight and normal and corpulence groups and BIA did not show the difference noted statistically in all groups and the between group comparison was exposed to do not have a meaning. The body percent fat measured by the correlation analysis result DXA at the state that it doesn't divide into the group showed the high correlation (r=0.908, p0.01) noted statistically compared with BMI and showed the high correlation noted statistically in a comparison with BIA (r=0.927, p0.01). Conclusion: It confirmed that the whole body percent fat presumed from the part bone density measurement showed the excel correlation compared with BIA and BMI and information is high. There is still no clear standard about the presumed whole body percent fat and it is difficult to evaluate the fat evaluation by the bone mineral density measurement. However, it is determined that the information offering which is more objective through the comparative study with the body percent fat which is very efficient and in that it can obtain till the information about a fat as well as diagnosis of the osteoporosis through the bone density checkup is measured by the afterward telegraph bone density checkup and is clinically useful is possible.

  • PDF

Application of an Energy Sensitive CZT Detector to a DXA Type of Bone Densitometer

  • Yoon, Je-Woong;Lee, Hyung-Koo;Lee, Heung-Kyu
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.422-424
    • /
    • 2002
  • The accuracy of DXA(Dual Energy X-ray Absorptiometry) highly depends on the detection and separation capability of dual energy X-ray X-ray photons. In addition both of scan time and patient exposure are affected by detection efficiency. A CZT detector with a good energy resolution and high detection efficiency was evaluated for the application of bone densitometry. Its performance was compared to a photomultiplier tube with a NaI(T1) scintillator in terms of energy resolution, detection efficiency and the accuracy of bone mineral density measurement. The comparison study was performed with CZT detector and PM tube using DXA equipments(OSTEO Plus, OSTEO Prima, ISOL Technology). The energy spectrum was acquired using MCA(Multi-Channel Analyzer). The used X-ray energy ranged from 20keV to 86keV. The MCA result of the CZT detector showed a slightly sharper energy spectrum than that of NaI(T1). Detection efficiency of the CZT detector at 59.5keV was 1.4 times better. Remarkably the final results of bone mineral density measurements demonstrate only less than 1% difference. The CZT detector appears to have many benefits for the application of bone densitometry. Its excellent energy resolution can enhance the counting accuracy of dual energy X-ray spectrum. Furthermore its compactness in physical dimension and no cooling requirement will be additional benefits for a more compact and accurate bone densitometer.

  • PDF

Osteoporosis prediction from the mandible using cone-beam computed tomography

  • Barngkgei, Imad;Haffar, Iyad Al;Khattab, Razan
    • Imaging Science in Dentistry
    • /
    • v.44 no.4
    • /
    • pp.263-271
    • /
    • 2014
  • Purpose: This study aimed to evaluate the use of dental cone-beam computed tomography (CBCT) in the diagnosis of osteoporosis among menopausal and postmenopausal women by using only a CBCT viewer program. Materials and Methods: Thirty-eight menopausal and postmenopausal women who underwent dual-energy X-ray absorptiometry (DXA) examination for hip and lumbar vertebrae were scanned using CBCT (field of view: $13cm{\times}15cm;$ voxel size: 0.25 mm). Slices from the body of the mandible as well as the ramus were selected and some CBCT-derived variables, such as radiographic density (RD) as gray values, were calculated as gray values. Pearson's correlation, one-way analysis of variance (ANOVA), and accuracy (sensitivity and specificity) evaluation based on linear and logistic regression were performed to choose the variable that best correlated with the lumbar and femoral neck T-scores. Results: RD of the whole bone area of the mandible was the variable that best correlated with and predicted both the femoral neck and the lumbar vertebrae T-scores; further, Pearson's correlation coefficients were 0.5/0.6 (p value=0.037/0.009). The sensitivity, specificity, and accuracy based on the logistic regression were 50%, 88.9%, and 78.4%, respectively, for the femoral neck, and 46.2%, 91.3%, and 75%, respectively, for the lumbar vertebrae. Conclusion: Lumbar vertebrae and femoral neck osteoporosis can be predicted with high accuracy from the RD value of the body of the mandible by using a CBCT viewer program.

Study on Oneself Developed to Apparatus Position of Measurement of BMD in the Distal Radius (자체 개발한 보조기구로 원위 요골의 골밀도 측정 자세 연구)

  • Han, Man-Seok;Song, Jae-Yong;Lee, Hyun-Kuk;Yu, Se-Jong;Kim, Yong-Kyun
    • Journal of radiological science and technology
    • /
    • v.32 no.4
    • /
    • pp.419-426
    • /
    • 2009
  • Purpose : The aim of this study was to evaluate the difference of bone mineral density according to distal radius rotation and to develop the supporting tool to measure rotation angles. Materials and Methods : CT scanning and the measurement of BMD by DXA of the appropriate position of the forearm were performed on 20 males. Twenty healthy volunteers without any history of operations, anomalies, or trauma were enrolled. The CT scan was used to evaluate the cross sectional structure and the rotation angle on the horizontal plane of the distal radius. The rotational angle was measured by the m-view program on the PACS monitor. The DXA was used in 20 dried radii of cadaveric specimens in pronation and supination with five and ten degrees, respectively, including a neutral position (zero degrees) to evaluate the changes of BMD according to the rotation. Results : The mean rotation angle of the distal radius on CT was 7.4 degrees of supination in 16 cases (80%), 3.3 degrees of pronation in three cases (15%), and zero degree of neutral in one case (9%), respectively. The total average rotation angle in 20 people was 5.4 degrees of supination. In the cadaveric study, the BMD of the distal radius was different according to the rotational angles. The lowest BMD was obtained at 3.3 degrees of supination. Conclusion : In the case of the measurement of BMD in the distal radius with a neutral position, the rotational angle of the distal radius is close to supination. Pronation is needed for the constant measurement of BMD in the distal radius with the rotation angle measuring at the lowest BMD and about five degrees of pronation of the distal radius is recommended.

  • PDF

Improvement of Low Bone Mineral Density Treated with Jeopgol-tang in a Middle-Aged Man: A Case Report (중년 남성에서 접골탕 투여 후 개선된 골밀도에 관한 증례 보고)

  • Won, Jiyoon;Choi, Youngjin;Lee, Byung-Cheol;Lee, Hyangsook
    • The Journal of Korean Medicine
    • /
    • v.42 no.2
    • /
    • pp.90-97
    • /
    • 2021
  • Bone mineral density (BMD) is a major diagnostic marker for bone health. A 44-year-old male had BMD of 0.81 g/cm2 (Z-score: -3.1) in lumbar spine scan and 0.54 g/cm2 (Z-score: -2.7) for femoral neck from regular medical checkup in Apr 2020. He had no other specific medical conditions except hyperlipidemia and alcohol was a single risk factor for fracture according to Fracture Risk Assessment Tool. After he was diagnosed with liver-kidney deficiency and treated for 20 weeks with Jeopgol-tang originally patented for promoting fracture recovery, lumbar spine BMD increased by 13.6 % (0.92 g/cm2, Z-score: -2.1) and femoral neck BMD by 22.2% (0.66 g/cm2, Z-score: -1.8) compared with those of Mar 2020. Herbal medicine treatment for tonifying liver and kidney to improve BMD warrants further investigation.

The Diagnosis and Treatment of Osteoporosis (골다공증의 진단과 치료)

  • Moon, Jun-Sung;Won, Kyu-Chang
    • Journal of Yeungnam Medical Science
    • /
    • v.25 no.1
    • /
    • pp.19-30
    • /
    • 2008
  • Osteoporosis, a disease characterized by low bone mass and microarchitectural deterioration of bone tissue leading to enhanced bone fragility and fracture risk, is a major public health problem. The diagnostic methods for osteoporosis include simple radiography, bone scan, DXA (Dual energy X-ray Absortiometry) and biochemical markers of bone turnover. Optimal treatment and prevention of osteoporosis require modification of risk factors, particularly smoking cessation, adequate physical activity, and attention to diet, in addition to pharmacologic intervention. The estrogens and raloxifene both prevent bone loss in postmenopausal women, and the estrogens probably also decrease the risk of first fracture. There is good evidence that raloxifene prevents further fractures in postmenopausal women who already have had fractures and some evidence that estrogen does as well. Bisphosphonate prevents bone loss and reduces fractures in healthy and osteoporotic postmenopausal women and in osteoporotic men as well. Risedronate is more potent and has fewer side effects than alendronate and reduces the incidence of fractures in osteoporotic women. Calcitonin increases bone mineral density in early postmenopausal women and men with idiopathic osteoporosis, and also reduces the risk of new fractures in osteoporotic women. All of the agents discussed above prevent bone resorption, whereas teriparatide and strontium increase bone formation and are effective in the treatment of osteoporotic women and men. New avenues for targeting osteoporosis will emerge as our knowledge of the regulatory mechanisms of bone remodeling increases, although issues of tissue specificity may remain to be addressed.

  • PDF