• Title/Summary/Keyword: DTS system

Search Result 46, Processing Time 0.026 seconds

Projection on First Flowering Date of Cherry, Peach and Pear in 21st Century Simulated by WRFv3.4 Based on RCP 4.5 and 8.5 Scenarios (WRF를 이용한 RCP 4.5와 8.5 시나리오 하의 21세기 벚, 복숭아, 배 개화일 변화 전망)

  • Hur, Jina;Ahn, Joong-Bae;Shim, Kyo-Moon
    • Atmosphere
    • /
    • v.25 no.4
    • /
    • pp.693-706
    • /
    • 2015
  • A shift of first fowering date (FFD) of spring blossoms (cherry, peach and pear) over the northest Asia under global warming is investiaged using dynamically downscaled daily temperature data with 12.5 km resolution. For the study, we obatained gridded daily data with Historical (1981~2010), and Representative Concentration Pathway (RCP) (2021~2100) 4.5 and 8.5 scenarios which were produced by WRFv3.4 in conjunction with HadGEM2-AO. A change on FFDs in 21st century is estimated by applying daily outputs of WRFv3.4 to DTS phonological model. Prior to projection on future climate, the performances of both WRFv3.4 and DTS models are evaluated using spatial distribution of climatology and SCR diagram (Normalized standard deviation-Pattern correlation coefficient-Root mean square difference). According to the result, WRFv3.4 and DTS models well simulated a feature of the terrain following characteristics and a general pattern of observation with a marigin of $1.4^{\circ}C$ and 5~6 days. The analysis reveals a projected advance in FFDs of cherry, peach and pear over the northeast Asia by 2100 of 15.4 days (9.4 days). 16.9 days (10.4 days) and 15.2 days (9.5 days), respectively, compared to the Historical simulation due to a increasing early spring (Februrary to April) temperature of about $4.9^{\circ}C$ ($2.9^{\circ}C$) under the RCP 8.5 (RCP 4.5) scenarios. This indicates that the current flowering of the cherry, peach and pear over analysis area in middle or end of April is expected to start blooming in early or middle of April, at the end of this century. The present study shows the dynamically downscaled daily data with high-resolution is helpeful in offering various useful information to end-users as well as in understanding regional climate change.

Audio Format Comparative Study and Suggestion for Next Generation DTV (차세대 디지털 TV 방송을 위한 오디오 규격 비교 분석 및 제언)

  • Lee, Jae-Hong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.30 no.6
    • /
    • pp.337-343
    • /
    • 2011
  • With commencing trial 3D digital broadcasting, the studies on next generation digital broadcasting technology for coming UHDTV era is being actively progressing. In this paper, I propose surround audio formats for next-generation digital TV broadcasting, along with comparative study of major surround audio formats in use or under development. I did comparative study on current major competing surround formats such as Dolby True HD and DTS HD MA, along with NHK proposed 22.2 channel surround format for UHDTV system. Upon this comparative study and our housing situation consideration, I propose lossy compression 3D surround 7.1 channel surround format along with loosless 2.0 and 4.0 hi-fi format as next generation digital TV broadcasting standard. In lieu with this, I also propose transmitting binaural 2 channel audio data as sub-audio. It will give holographic sound experience when properly processed with individual HRTF (Head Related Transfer Function) with headphone. The table for data rate of each proposed audio format is also presented.

A Study on the Comparison between an Optical Fiber and a Thermal Sensor Cable for Temperature Monitoring (온도 모니터링을 위한 광섬유 센서와 온도센서 배열 케이블의 비교 연구)

  • Kim, Jung-Yul;Kim, Yoo-Sung;Song, Yoon-Ho
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.1100-1109
    • /
    • 2006
  • In this study, two different technologies which can measure temperature simultaneously at many points are introduced. One is to use a thermal sensor cable that is comprised of addressable thermal sensors connected in parallel within a single cable. The other is to use an optic fiber with Distributed Temperature Sensing (DTS) system. The difference between two technologies can be summarized as follows. A thermal sensor cable has a concept of 'point sensing' that can measure temperature at accurate position of a thermal sensor. So the accuracy and resolution of temperature measurement are up to the ability of the thermal sensor. Whereas optic fiber sensor has a concept of 'distributed sensing' because temperature is measured by ratio of Stokes and anti-Stokes component intensities of Raman backscatter that is generated when laser pulse travels along an optic fiber. It's resolution is determined by measuring distance, measuring time and spatial resolution. The purpose of this study is that application targets of two temperature measurement techniques are checked in technical and economical phases by examining the strength and weakness of them. Considering the functions and characteristics of two techniques, the thermal sensor cable will be suitable to apply to the assessment of groundwater flow, geothermal distribution and grouting efficiency within 300m distance. It is expected that the optic fiber sensor can be widely utilized at various fields (for example: pipe line inspection, tunnel fire detection, power line monitoring etc.) which need an information of temperature distribution over relatively long distance.

  • PDF

A Security-Enhanced Storing Method for the Voice Data in the Aircraft (항공기에서 보안 강화된 음성 데이터 저장 방식)

  • Cho, Seung Hoon;Suh, Jeong Bae;Moon, Yong Ho
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.6 no.4
    • /
    • pp.255-261
    • /
    • 2011
  • In this paper, we propose a security-enhanced storing method for the voice data obtained during the flight. When an emergency occurs during flight, the flight data in the storage device such as DTS or Blackbox can be exposed to antagonist or enemy. Currently, zeroize function is embedded in these devices in order to prevent this situation. However, this could not be operated if the system is malfunctioned or the pilot is wounded in the emergency. In order to solve this problem, the voice data compressed by the ADPCM is encrypted in the proposed method composed of the AES algorithm and a reordering method. The simulation results show that the security for the voice date is further enhanced due to the proposed method.

Conceptual Design for Underground Hydrogen Pipeline Monitoring System: Case Study on Fiber Optic Sensing (지하매설 수소 배관망 안전 모니터링 시스템의 개념 설계: 광섬유 기반 모니터링 사례를 중심으로)

  • Park, Jae-Woo;Yeom, Dong-Jun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.4_2
    • /
    • pp.673-686
    • /
    • 2022
  • Recently, as the importance of eco-friendly energy has increased hydrogen gas is in the spotlight as future energy. Due to its special properties, hydrogen gas is more difficult to detect requiring more precise sensing technology. The primary objective of this study is to design a concept of an underground hydrogen pipeline monitoring system. For this, the following research works are conducted sequentially; 1)selection of core technology for conceptual design, 2)state-of-the-art review, 3)design of a concept of the system. As a result, DAS(Distributed Acoustic Sensing), and DTS(Distributed Temperature Sensing) are selected as each core technology. Furthermore, a conceptual design of an underground hydrogen pipeline monitoring system is deducted. It is expected that the impact on the eco-friendly energy industry will be enormous due to the increasing interest in using hydrogen energy.

The study on the fiber optic sensor for the distributed temperature measurement (분포온도 계측을 위한 광파이버 온도센서 시스템에 관한 연구)

  • 이광진;최성구;노도환
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.1746-1749
    • /
    • 1997
  • A distributed optical fiber temperature sensor can continually monitor the measurand at every point along of its fiber length. It is based on OTDR technics which used extreamlly weak backward scattered light called Raman scattering. When the Pulsed high intensity laser light injected into the optical fiber there are several kind of backscattered light such as Rayleigh, Stokes, and anti-Stokes, etc. caused by impurities molecular vibrations. The temperature distribution is derived form the intensity ratio Raman scatted light-Stokes versus anti-Stokes-and the time function between light injection and signal detection. It is shown that the priniciple of distributed sensing, the system desing, and the result of experiments.

  • PDF

The Relationship between Somatic Symptoms and the Trauma-Related Characteristics of Patients with PTSD : A Korean Multicenter Study (다기관 모집 외상 후 스트레스장애 환자에서 외상의 특성과 신체적 증상과의 관계)

  • Shin, Jae-Ho;Choi, Kyeong-Sook;Chae, Jeong-Ho;Woo, Jong-Min;Chee, Ik-Seung;Kim, Jung-Bum;Jeong, Mun-Yong
    • Anxiety and mood
    • /
    • v.4 no.1
    • /
    • pp.34-41
    • /
    • 2008
  • Objective : The aim of this study is to examine the characteristics of somatic symptoms in patients with PTSD according to trauma type. Methods : The subjects of this study were 84 patients diagnosed with PTSD according to the DSM-IVTR and CAPS criteria. The subjects ranged in age from 18 to 76 years, and they were recruited from 18 hospitals across the nation. All participants were asked about their trauma history, and they all completed the Davidson Trauma Scale (DTS), Beck Depression Inventory (BDI), State-Trait Anxiety Inventory (STAI), Impact of Event Scale-Revised (IES-R) and Korean-Physical Somatic Symptom Inventory (K-PSI). The items of the K-PSI were categorized into 5 groups according to organ system, and the participants were classified into 6 groups according to trauma type. We compared the results of the social demographical scale, DTS, BDI, STAI, IES-R and each recategorized subscale of the K-PSI among the six groups. Results : There were significant differences between the 6 groups in terms of the Korean-Physical Somatic Symptom Inventory scores for each organ system, except for the cardiopulmonary system, as well as the BDI scores. Post hoc analysis revealed differences between the combat-related trauma group and all other groups but not among any of the other groups. Conclusion : Our result showed that there were significant differences in the somatic symptom scores among the 6 trauma groups. However, patient age and the time elapsed since the traumatic event may have hada crucial influence on the result of this study.

  • PDF

Performance of connection of Waffle Shape Precast Prestressed Concrete Slab Panels (와플(Waffle) 형상을 가지는 PC 패널의 접합 성능)

  • Heo, Seok-Jae;Kim, Hyeon-Jin;Ryu, Han-Gook;Choi, Kyoung-Kyu;Cho, Seung-Ho;Chung, Lan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.305-308
    • /
    • 2008
  • This paper presents the results of an experimental study carried out Prestressed Concrete Slab System of WAffle Shape(WAS), was perfomed in order to inverstigate it connection shear behavior according to primary paramaters: connection interval, filling matarial. Specimen is produced in Precast Concrete factories and it comprised one WAS panel and two half WAS panels and then it is filled with packing. Within the ranges of the parameters of the connection details used in this test, connections can develop greater shear strength than the nominal shear strength and the design service load for parking structures.

  • PDF

The Analysis of Muscle Activities on the Lower Limb during Wearing Functional Insole (다기능성 인솔 착용 시 하지의 근활성도 분석)

  • Park, Jae-Young
    • Korean Journal of Applied Biomechanics
    • /
    • v.20 no.3
    • /
    • pp.327-336
    • /
    • 2010
  • The purpose of this study was to analyze muscle activities on functional insole with diet effect. Originally, ten healthy female subjects with an average age of 23.2 year(S.D=1.1), weight of 49.7 kg(S.D=4.9), height of 163.2 cm(S.D=3.5) and a shoe size of 237.5 cm(S.D=4.9) were participated in this experiment. Ten healthy females walked on a treadmill(speed=about 4.2 km/h) wearing two different insole types. Muscle activities data was collected using the EMG operating system. The surface EMG signal for tibialis anterior(TA), gastrocnemius(GA), vatus lateralis(VL) and biceps femoris(BF) were acquired at the RMS(10 Hz, 350 Hz) using Noraxon Telemyo DTS system(Noraxon inc, USA). This study processed the data using the Windows SPSS ver.17.0 to get an independent t-test, with the setting, p<.05. Analysis of muscle activity were measured and calculated during walking. The results are as follow: Functional insole wearing were increased muscle activities significantly from Tibialis anterior(TA) during total gait cycle. Normal distribution was demonstrated in total step of stances period. One foot standing position showed decreased muscle activity. Two foot standing position was demonstrated with gastrocnemius and biceps femoris. As a result of the analysis, Functional insole will inerease the diet effect in the use of four muscle groups.

A Study on the Comparison between an Optical Fiber and a Thermal Sensor Cable for Temperature Monitoring (온도 모니터링을 위한 광섬유 센서와 온도센서 배열 케이블의 비교 연구)

  • Kim, Jung-Yul;Song, Yoon-Ho;Kim, Yoo-Sung
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.4
    • /
    • pp.15-24
    • /
    • 2007
  • Two kinds of temperature monitoring technology have been introduced in this study, which can measure coincidently temperatures at many points along a single length of cable. One is to use a thermal sensor cable comprizing of addressable thermal sensors. The other is to use an optic fiber sensor with Distributed Temperature Sensing (DTS) system. The differences between two technologies can be summarized as follows: A thermal sensor cable has a concept of "point sensing" that can measure temperature only at a predefined position. The accuracy and resolution of temperature measurement are up to the capability of the individual thermal sensor. On the other hand, an optic fiber sensor has a concept of "distributed sensing" because temperature is measured practically at all points along the fiber optic cable by analysing the intensity of Raman back-scattering when a laser pulse travels along the fiber. Thus, the temperature resolution depends on the measuring distance, measuring time and spatial resolution. The purpose of this study is to investigate the applicability of two different temperature monitoring techniques in technical and economical sense. To this end, diverse experiments with two techniques were performed and two techniques are applied under the same condition. Considering the results, the thermal sensor cable will be well applicable to the assessment of groundwater flow, geothermal distribution and grouting efficiency within about loom distance, and the optic fiber sensor will be suitable for long distance such as pipe line inspection, tunnel fire detection and power line monitoring etc.