• Title/Summary/Keyword: DTPA

Search Result 273, Processing Time 0.029 seconds

Optimization of GFR value according to Kidney Depth Measurement Methods (신장 Depth 측정 방법에 따른 GFR 값의 최적화)

  • Kwon, Hyeong-Jin;Moon, Il-Sang;Noh, Gyeong Woon;Kang, Keon Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.2
    • /
    • pp.25-28
    • /
    • 2019
  • Purpose In patients with unusual kidney position after $^{99m}Tc-DTPA$ renal dynamic imaging study, the GFR(Glomerular Filtration Rate) values are significantly different according to the depth of the kidney. Thus, we tried to compare the difference of the GFR values between the depth measurement methods and in-vitro test. 30 adult patients who were subjected to renal study. 27 patients were in usual position and 3 patients were in unusual. $555{\pm}37MBq$ of $^{99m}Tc-DTPA$ was administrated to all patients. GE infinia gamma camera was used. GFR values were obtained in-vivo(gates method) and in-vitro(blood). The kidney depth in-vivo was calculated by three methods(tonnensen, manual, taylor). In-vitro, GFR was performed by blood test. Differences in the mean values of GFR and correlation between depth and GFR values were evaluated using the SPSS 12.0 statistical program. The GFR values for 27 patients with kidney in the usual position are as follows(1.tonnensen 2.manual 3.taylor 4.invitro); $69.3{\pm}4.2$, $88.2{\pm}5.6$, $77.8{\pm}4.3$, $82.2{\pm}5.8ml/min$. The three unusual cases are as follows, first(congenital renal anomaly): 66.4, 101.24, 69.07, 94.8 ml/min. second(transplantation kidney): 12.22, 29.99, 19.36, 23.5 ml/min. third(horseshoe kidney): 37.37, 93.54, 35.9, 92.5 ml/min. There was a difference between tonnensen and manual in the usual position of the kidney(p<0.05). There was no significant difference between the other methods. However, there was a significant difference in case of the unusual position of the kidneys. Correlation analysis between both kidney depth and GFR value shows person correlation as follows; Rt kidney: 0.298, Lt kidney: 0.322. When compared with the GFR values in-vitro test, it was useful to calculate the GFR value by measuring the kidney depth using a manual formula in the unusual position of the kidneys. GFR values and kidney depth were significantly related.

Comparison of Three, Motion-Resistant MR Sequences on Hepatobiliary Phase for Gadoxetic Acid (Gd-EOB-DTPA)-Enhanced MR Imaging of the Liver

  • Kim, Doo Ri;Kim, Bong Soo;Lee, Jeong Sub;Choi, Guk Myung;Kim, Seung Hyoung;Goh, Myeng Ju;Song, Byung-Cheol;Lee, Mu Sook;Lee, Kyung Ryeol;Ko, Su Yeon
    • Investigative Magnetic Resonance Imaging
    • /
    • v.21 no.2
    • /
    • pp.71-81
    • /
    • 2017
  • Purpose: To compare three, motion-resistant, T1-weighted MR sequences on the hepatobiliary phase for gadoxetic acid-enhanced MR imaging of the liver. Materials and Methods: In this retrospective study, 79 patients underwent gadoxetic acid-enhanced, 3T liver MR imaging. Fifty-nine were examined using a standard protocol, and 20 were examined using a motion-resistant protocol. During the hepatocyte-specific phase, three MR sequences were acquired: 1) gradient recalled echo (GRE) with controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA); 2) radial GRE with the interleaved angle-bisection scheme (ILAB); and 3) radial GRE with golden-angle scheme (GA). Two readers independently assessed images with motion artifacts, streaking artifacts, liver-edge sharpness, hepatic vessel clarity, lesion conspicuity, and overall image quality, using a 5-point scale. The images were assessed by measurement of liver signal-to-noise ratio (SNR), and tumor-to-liver contrast-to-noise ratio (CNR). The results were compared, using repeated post-hoc, paired t-tests with Bonferroni correction and the Wilcoxon signed rank test with Bonferroni correction. Results: In the qualitative analysis of cooperative patients, the results for CAIPIRINHA had significantly higher ratings for streak artifacts, liver-edge sharpness, hepatic vessel clarity, and overall image quality as compared to, radial GRE, (P < 0.016). In the imaging of uncooperative patients, higher scores were recorded for ILAB and GA with respect to all of the qualitative assessments, except for streak artifact, compared with CAIPIRINHA (P < 0.016). However, no significant differences were found between ILAB and GA. For quantitative analysis in uncooperative patients, the mean liver SNR and lesion-to-liver CNR with radial GRE were significantly higher than those of CAIPIRINHA (P < 0.016). Conclusion: In uncooperative patients, the use of the radial GRE sequence can improve the image quality compared to GRE imaging with CAIPIRINHA, despite the data acquisition methods used. The GRE imaging with CAIPIRINHA is applicable for patients without breath-holding difficulties.

Mutual Separation of Am(III) and Eu(III) by Solvent Extraction with Cyanex 301 (Cyanex 301에 의한 Am(III)과 Eu(III)의 상호분리)

  • Yang, Han-Beom;Lim, Jae-Gwan;Lee, Eil-Hee;Yoo, Jae-Hyung
    • Applied Chemistry for Engineering
    • /
    • v.10 no.1
    • /
    • pp.143-147
    • /
    • 1999
  • The present paper describes the solvent extraction behaviors and the mutual separation of Am and Eu by sulphur bearing Cyanex 301 acidic extractant in sodium nitrate solutions. Original Cyanex 301 was not able to separate the Am and Eu because of their similar extraction behaviors. The saponification of commercial Cyanex 301 was performed by small amounts of 8 M NaOH solutions and saponified Cyanex 301 was able to separate of Am from Eu with high selectivity in sodium nitrate aqueous solution. The separation factors ($SF_{Am/Eu}$) were increased with saponified ratio of commercial Cyanex 301, pH of sodium nitrate solution and initial concentration of Eu. To obtain the homogeneous saponified Cyanex 301, heterogeneous saponified Cyanex 301 was treated with addition of octyl alcohol or filtration. The observed $SF_{Am/Eu}$ was 32.3 for the former and 930 for the latter. Finally, the stripping behaviors of Am and Eu were similar and stripping yields showed 96.1% for the 1 M $NaNO_3$(pH=1.3) and 99% for the mixture solution of 0.05 M DTPA and 1.5 M lactic acid.

  • PDF

Construction of T$_1$ Map Image (T1 이완시간의 영상화)

  • 정은기;서진석;이종태;추성실;이삼현;권영길
    • Progress in Medical Physics
    • /
    • v.6 no.2
    • /
    • pp.83-92
    • /
    • 1995
  • The T1 mapping of an human anatomy may give a characteristic contrast among the various tissues and the normal/abnormal tissues. Here, the methodology of constructing T1 map out of several images with different TRs, will be described using non-linear curve fitting. The general curve fitting algorithm requires the initial trial values T1t and Mot for the variables to be fitted. Three different methods of suppling the trial T1t and Mot are suggested and compared for the efficiency and the accuracy. The curve-fitting routine was written in ANSI C and excuted on a SUN workstation. Several distilled-water phantoms with various concentrations of Gd-DTPA were prepared to examine the accuracy of the curve-fitting program. An MR image was used as the true proton density image without any random noise, and several images with different TRs were generated with the theoretical T1 relaxation times 250, 500, and 1000msec. The random noise of 1, 5, and 10% were embedded into the simulated images. These images were used to generate the T1 map, and the resultant T1 maps for each T1 were analyzed to study the effect of the random noise on the T1 map.

  • PDF

Evaluation of co- and Mutual Weparation for Actinide(III) and RE by a $(Zr-DEHPA)/n-dodecane-HNO_3$ Extraction System ($(Zr-DEHPA)/n-dodecane-HNO_3$ 금속함유 추출 계에 의한 악티나이드(III)및 RE의 공추출 및 상호 분리)

  • Lee, Eil-Hee;Lim, Jae-Kwan;Chung, Dong-Yong;Yang, Han-Beom;Kim, Kwang-Wook
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.5 no.2
    • /
    • pp.123-132
    • /
    • 2007
  • This study was performed to evaluate the co- and mutual separation for Am, Cm and RE elements from the simulated multi-component solution equivalent to real HLW level by a Zr-DEHPA(di-(2-ethylhexyl) phosphoric acid containing Zirconium)/$NDD(n-dodecane)-HNO_3$ extraction system. Zr-DEHPA was self-synthesized and the optimal condition of (15g/L Zr-1M DEHPA)/NDD-1M $HNO_3$ was selected taking into consideration of prevention of the third phase, and effects of concentration of DEHPA, nitric acid and impregnant amount of Zr on the co-extraction of Am, Cm and RE. In that condition, the extraction yields were 81% (Am), 85% (Cm), more than 80% (RE elements), 98% (Mo), 85% (Fe), 98% (U), 73% (Np), and less than 5% (other elements) so that the system developed for the co-extraction of Am-Cm/RE was proved to be available. For that, however, U, Np, Mo and Fe was elucidated to have to be removed in advance, and Zr inducing the third phase formation was found to be practically excluded. The co-extracted Am-Cm/RE were sequentially separated in an order of Am-Cm (stripping agent : 0.05 M DTPA-1M Lactic acid of pH 3.6)${\rightarrow}RE$ (stripping agent : 5M $HNO_3$), and then their separation factors were evaluated. At above conditions, Am of 65.4%, Cm of 63.9%, RE (except for Y) of more than 85% were stripped.

  • PDF

Significance of Dynamic MRI in Brain Tumors

  • Kim, Dong-Woo;Sung, Soon-Ki;Song, Young-Jin;Choi, Soon-Seop;Kim, Dae-Cheol;Choi, Young-Min;Huh, Won-Ju;Kim, Ki-Uk
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.1
    • /
    • pp.27-34
    • /
    • 2007
  • Objective : On the magnetic resonance image (MRI) of the infiltrating brain tumor, enhancement is usually higher in malignant tumor than in benign tumor, and tumor cells can invade into the peritumoral area without definite enhancement. In various pathological conditions, the blood brain barrier (BBB) becomes changed to pathological condition, allowing various materials extravasating into the interstitial space, and degree of enhancement is depend on the pathology. Authors performed dynamic MRI on enhancing and surrounding edematous area in order to evaluate the degrees of opening of BBB, to differentiate tumor from non-tumorous condition, and to determine its relationship with the recurrence of the tumor. Methods : Dynamic MRI was performed in 25 patients. Dynamic scans were done every 15 seconds after administration of Gd-DTPA on the enhancing and surrounding area for maximum 300 seconds, and the patterns of enhancement were ana lysed. The enhancement curve with initial steep increase followed by slow decrease was defined as "N pattern", those with initial steep increase followed by additional slow increase as "T pattern", and those with initial steep increase followed by plateau as "E pattern". Histopathological findings were compared with the dynamic scan. Results : The graphs taken from enhancing area showed "T pattern" regardless of pathology. In the surrounding area, "T pattern" was noticed in the malignant tumors, but "E pattern" or "N pattern" was noted in low-grade or benign tumors and non-tumorous condition. "T pattern" in the surrounding area was related to the malignant with tumor cell infiltration and recurrence. Conclusion : The results suggest that the malignant tumor infiltration changes the condition of BBB enough to extravasate the Gd-DTPA. Enhancement pattern in the surrounding edematous area may be a useful information to differentiate the malignant glioma with the low-grade and benign tumors or other non-tumorous conditions.

Absorbed Dose for the Endovascular Ho-166-DTPA Brachytherapy Using a Balloon Angio Catheter (풍선도자관의 Ho-166-DTPA 흡수선량)

  • 조철우;박찬희;윤석남;강해준;김미화;장지선;박경배
    • Progress in Medical Physics
    • /
    • v.13 no.2
    • /
    • pp.98-103
    • /
    • 2002
  • The purpose of this study was to evaluate the absorbed dose to the coronary artery segment from various sized balloon angio catheters. The liquid form of Ho-166 was produced at the KAERI by (n, ${\gamma}$ ) reaction. We used GafChromic film for the estimation of the absorbed dose by beta particles. The exposed films were read using a videodensitometer. Several film exposures were made with varying irradiation times and activities. A modified micrometer was used for the measurement of the absorbed dose distribution near the balloon surface. Four balloons of coronary catheters evaluated were 30 m long and 2.5, 3.0, 3.5 and 4.0 mm in diameter. All doses are plotted in units of Gy/min/GBq/ml as a function of radial distance in mm from the surface of balloon. The absorbed dose rate was 0.86, 1.01, 1.11 and 1.24 Gy/min/GBq/ml at a balloon surface for various balloon diameter 2.5, 3.0, 3.5 and 4.0 mm respectively. Using a vacuum pump, the air in the balloon was evacuated prior to instillation of the Ho-166 source. By removing air bubbles in the balloon, the absorbed dose distribution was more uniform.

  • PDF

Captopril $^{99m}Tc-DTPA$ Renal Scintigraphy in Diagnosis of Renovascular Hypertension (신혈관성 고혈압의 진단에 있어서 캅토프릴 신스캔의 의의)

  • Yang, Hyung-In;Lee, Dong-Soo;Kim, Sung-Chul;Bae, Sang-Kyun;Choi, Chang-Woon;Chung, June-Key;Kim, Suhng-Gwon;Lee, Myung-Chul;Lee, Jung-Sang;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.26 no.2
    • /
    • pp.312-317
    • /
    • 1992
  • To evaluate the sensitivity and specificity of captopril renal scan for renovascular hypertension, we employed the captopril renal scan in conjunction with renal angiography in 81 patients, 159 kidneys, who were referred to evaluate the cause of hypertension. We defined the renovascular hypertension by the criteria of demonstration of renal artery stenosis by angiography, and improvement or cure of hypertension by revascularization. Visual and quantitative evaluation of $^{99m}Tc-DTPA$ renal scan was peformed pre and post captopril administration. The prevalence rate of renovascular hypertension was 40% in comparing with renal angiography, and 70% in confirmed cases. The causes of renovascular hypertension in 81 patients were Takayasu's arteritis, fibromuscular dysplasia, atherosclerosis, essential hypertension, chronic pyetonephritis etc. The sensitivity and specificity of captopril renal scan in comparing with renal angiography were 80%, 86.5%, respectively and also 84.2%, 72.6% in confirmed cases of renovascular hypertension, respectively. The causes of false negative cases were nonfunctioning kidney due to complete obstruction or long duration of disease in basal scan, segmental branch artery stenosis, unknown causes, and suspicious true negative cases without confirmation. The false positive cases were abdominal aortic stenosis or aneurysm, dehydration, unknown causes, and suspicious true positive cases. We conclude that captopril renal scintigraphy is highly sensitive, reasonably specific diagnostic method and comparable to other techniques very favorably.

  • PDF

Mutual Separation of Am and Eu by Solvent Extraction with di-(2-ethylhexyl)phosphoric acid Containing Zirconium(III) (Zr을 함유한 di-(2-ethylhexyl)phosphoric acid에 의한 Am과 Eu의 상호분리(III))

  • Yang, Han-Beom;Lee, Eil-Hee;Lim, Jae-Gwan;Kim, Jong-Gu;Kim, Jung-Suk;Yoo, Jae-Hyung
    • Applied Chemistry for Engineering
    • /
    • v.8 no.6
    • /
    • pp.1006-1013
    • /
    • 1997
  • This study was carried out to elucidate the chemical characteristics of mutual separation for Am and Eu, which were selected as a stand-in from minor actinide and rare earth elements, by solvent extraction with di-(2-ethylhexyl)phosphoric acid containing zirconium at batch system. As results, 92.3% of Am and 99.1% of Eu were coextracted with 1M DEHPA/n-dodecane containing zirconium (Zr $concentration=8.7g/{\ell}$) at 0.5M $HNO_3$ in the extraction step. The extraction yields of Am and Eu were proportionally increased with the concentration of Zr in Zr salt of 1M DEHPA/n-dodecane having the synergistic effect. In the lst stripping step for the selective separation of Am, 38.1% of Am and 3% of Eu were stripped with the mixed solution of 0.05M DTPA and 1M lactic acid adjusted pH of 3.0. At that time, the separation factor calculated from the distribution coefficients of Am and Eu was 14.2. In the 2nd Stipping step to remove the Eu remained the organic phase after the lst stripping step, 94.4% 0f Eu was stripped into aqueous phase with 6M $HNO_3$.

  • PDF

Effect of chelating agent and organic acid on strontium distribution in Wistar rats (착화제와 유기산이 Wistar rat체내의 Sr 분포에 미치는 영향)

  • Lee, Kee-Ho;Lee, Je-Ho;Park, Sang-Yoon;Lee, Seung-Hoon;Ryu, Yong-Wun;Yun, Taik-Koo
    • Journal of Radiation Protection and Research
    • /
    • v.15 no.2
    • /
    • pp.41-49
    • /
    • 1990
  • $^{88}SrCl_2$ was injected to the tail vein of Wistar rats and investigated its distribution and clearance in the tissues and blood. We also measured the changes in Sr binding to the blood plasma protein by administrating chelating agents and organic acids. For the blood, 60% of the Sr occurred in the plasma and 40% on the cell membrane. Fifty percent of Sr in the blood plasma was bound to plasma protein. Sr on the cell membrane seemed to be bound loosely. The binding in the lymphocyte was higher than in the erythrocyte .and granulocyte. Within one hour Sr was quickly disappeared from the blood stream, to be accumulated in the bone. Twenty four hours after the injection, Sr decreased rapidly in the organs of soft tissue, but slowly in the bone. The binding of Sr to plasma protien decreased from 57% of the control to 27-33% in the group treated with chelating agents, EDTA, EGTA and DTPA and to 19% and 40% in the groups treated with organic acids, citrate and oxalate, respectively.

  • PDF