• Title/Summary/Keyword: DSP processor

검색결과 721건 처리시간 0.036초

Repetitive Control for Track-Following Servo of an Optical Disk Drive Using Linear Matrix Inequalities (선형 행렬 부등식을 이용한 광 디스크 드라이브의 트랙 추종 서보를 위한 반복 제어)

  • 도태용;문정호
    • Journal of Institute of Control, Robotics and Systems
    • /
    • 제9권2호
    • /
    • pp.117-123
    • /
    • 2003
  • Rotational machines such as optical disk drives, hard disk drives, and so on are subject to periodic disturbances caused by their mechanical characteristics. In the meanwhile, it is well known that repetitive control rejects periodic disturbance effectively. This paper presents a practical application of repetitive control to the track-following servo of an optical disk drive. The repetitive control system is composed of two repetitive controllers which compensate for periodic disturbances generated by track geometry and eccentric rotation of disk and a feedback controller stabilizing the feedback loop. A robust stability for all plant uncertainties is proved using linear matrix inequalities (LMIs). In the controller design, a weighting function is introduced for the feedback controller to ensure a minimum loop gain and a sufficient phase margin. The repetitive controllers and the feedback controller are designed by solving an optimization problem which can consider the robust stability condition and the system performance. The developed repetitive control system is implemented in the digital control system with a 16-bit fixed-point digital signal processor (DSP). Through simulation and experiment. The feasibility of the proposed repetitive control system is verified.

Fast Response and Versatility in Digitally Controlled Rolling Mill DC Drives (고성능, 다기능의 Rolling Mill DC전동기 제어 시스템 개발)

  • Kim, K.H.;Cho, W.J.;Park, I.Y.;Song, S.H.;Park, K.W.;Choi, C.H.;Sul, S.K.;Ji, J.K.
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.595-602
    • /
    • 1994
  • PERISTOR-3000 loaded with 32 bit DSP(Digital Signal Processor) is a technically advanced versatile dc motor controller in applications with very high requirements for rapid response, control accuracy and reliability. The current controller of PERISTOR-3000 is of the predictive type and gives fast control with both discontinuous and continuous current compared to the conventional PI current control. The speed controller gain is compensated to improve response behavior. PERISTOR-3000 communicates with its host computer, POSTAR-3200, or any IBM or compatible PC and can be controlled. Dedicated monitoring system for MMI is introduced.

  • PDF

Robust Internal Model Control of Three-Phase Active Power Filter for Stable Operation in Electric Power Equipment (전력설비의 안정한 운용을 위한 3상 능동전력필터의 강인한 내부모델제어)

  • Park, Ji-Ho;Kim, Dong-Wan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • 제62권10호
    • /
    • pp.1487-1493
    • /
    • 2013
  • A new simple control method for active power filter, which can realize the complete compensation of harmonics is proposed. In the proposed scheme, a model-based digital current control strategy is presented. The proposed control system is designed and implemented in a form referred to as internal model control structure. This method provides a convenient way for parameterizing the controller in term of the nominal system model, including time-delays. As a result, the resulting controller parameters are directly set based on the power circuit parameters, which make tuning of the controllers straightforward task. In the proposed control algorithm, overshoots and oscillations due to the computation time delay is prevented by explicit incorporating of the delay in the controller transfer function. In addition, a new compensating current reference generator employing resonance model implemented by a DSP(Digital Signal Processor) is introduced. Resonance model has an infinite gain at resonant frequency, and it exhibits a band-pass filter. Consequently, the difference between the instantaneous load current and the output of this model is the current reference signal for the harmonic compensation.

Research on the Mechanism of Neutral-point Voltage Fluctuation and Capacitor Voltage Balancing Control Strategy of Three-phase Three-level T-type Inverter

  • Yan, Gangui;Duan, Shuangming;Zhao, Shujian;Li, Gen;Wu, Wei;Li, Hongbo
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권6호
    • /
    • pp.2227-2236
    • /
    • 2017
  • In order to solve the neutral-point voltage fluctuation problem of three-phase three-level T-type inverters (TPTLTIs), the unbalance characteristics of capacitor voltages under different switching states and the mechanism of neutral-point voltage fluctuation are revealed. Based on the mathematical model of a TPTLTI, a feed-forward voltage balancing control strategy of DC-link capacitor voltages error is proposed. The strategy generates a DC bias voltage using a capacitor voltage loop with a proportional integral (PI) controller. The proposed strategy can suppress the neutral-point voltage fluctuation effectively and improve the quality of output currents. The correctness of the theoretical analysis is verified through simulations. An experimental prototype of a TPTLTI based on Digital Signal Processor (DSP) is built. The feasibility and effectiveness of the proposed strategy is verified through experiment. The results from simulations and experiment match very well.

Dual Current Control Scheme of a Grid-connected Inverter for Power Quality Improvement in Distributed Generation Systems (분산 전원 시스템의 전력품질 향상을 위한 계통연계 인버터의 이중 전류제어 기법)

  • Kim, Kyeong-Hwa
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • 제29권9호
    • /
    • pp.33-41
    • /
    • 2015
  • To improve the power quality of distributed generation (DG) systems even in the presence of distorted grid condition, dual current control scheme of a grid-connected inverter is proposed. The proposed current control scheme is achieved by decomposing the inverter state equations into the fundamental and harmonic components. The derived models are employed to design dual current controllers. The conventional PI decoupling current controller is used in the fundamental model to control the main power flow in DG systems. At the same time, the predictive control is applied in the harmonic model to suppress undesired harmonic currents to zero quickly. To decompose the voltage inputs and state variables into the fundamental and harmonic components, the fourth order band pass filter (BPF) is designed in the discrete-time domain for a digital implementation. For experimental verification, 2kVA prototype of a grid-connected inverter has been constructed using digital signal processor (DSP) TMS320F28335. The effectiveness of the proposed strategy is demonstrated through comparative simulation and experimental results.

A Study on Graylevel Image Scanning System Realization Using CIS (CIS를 이용한 그레이레벨 이미지 스케닝시스템 구현에 관한 연구)

  • 김영빈;김윤호;류광렬
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • 제6권3호
    • /
    • pp.470-474
    • /
    • 2002
  • The graylevel image scanning system realization and design using CIS(Contact image Scanning)be amenable to recognize a papers, OMR and OCR sheet is proposed. The design technique is used CIS scanning sensor in fixing step motor and is optimized with DSP processor for inage processing, and transfer input image data par line in feeding a step unit to PC on the USB interfacer. This system is portable ad A4 size scanning. and keeps image scan processing speed 300mm/sec. The recognition percentage has 98% on the OCR and bar codes.

Study on current control loop error MPPT controller using the power balance/unbalance boundary point control (전력 평형/불평형 경계점 제어를 이용한 전류제어루프에러 MPPT제어기에 관한 연구)

  • Kang, T.K.;Koh, K.H.;No, S.S.;Kang, J.S.;Lee, J.Y.;Woo, J.I.;Lee, H.W.
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 한국조명전기설비학회 2005년도 춘계학술대회논문집
    • /
    • pp.292-297
    • /
    • 2005
  • This paper proposes a simple MPPT control scheme of a Current-Control-Loop Error system Based that can be obtains a lot of advantage to compare with another digital control method, P&O and IncCond algorithm, that is applied mostly a PV system. An existent method is needed an expensive processor such as DSP that calculated to change the measure power of a using current and voltage sensor at the once. Therefore, it is applied a small home power generation system that required many expenses. But, a proposed method is easy to solve the cost reduction and power unbalance problems that it is used by control scheme to limit error of a current control of common sensor. This proposed algorithm had verified through a simulation and an experiment on battery charger using PIC that is the microprocessor of a low price.

  • PDF

Power Quality Improvement for Grid Connected Inverters under Distorted and Unbalanced Grids

  • Kim, Hyun-Sou;Kim, Jung-Su;Kim, Kyeong-Hwa
    • Journal of Power Electronics
    • /
    • 제16권4호
    • /
    • pp.1578-1586
    • /
    • 2016
  • A power quality improvement scheme for grid connected inverters, even in the presence of the disturbances in grid voltages due to harmonic distortions and three-phase imbalance, is presented for distributed generation (DG) power systems. The control objective is to force the inverter currents to follow their references with robustness even under external disturbances in grid voltages. The proposed scheme is realized by a disturbance observer (DOB) based current control scheme. Since the uncertainty in a system can be effectively canceled out using an estimated disturbance by the DOB, the resultant system behaves like a closed-loop system consisting of a disturbance-free nominal model. For experimental verification, a 2 kVA laboratory prototype of a grid connected inverter has been built using a digital signal processor (DSP) TMS320F28335. Through comparative simulations and experimental results under grid disturbances such as harmonic distortion and imbalance, the effectiveness of the proposed DOB based current control scheme is demonstrated.

Operational Characteristic Analysis of a Single-Phase PCS for PV Power Generation System with Active Filter Function (엑티브 필터 기능을 가지는 단상 태양광 PCS의 운전특성 해석)

  • Jang, Seong-Jae;Seo, Hyo-Ryong;Kim, Gyeong-Hun;Park, Sang-Soo;Kim, Sang-Yong;Park, Min-Won;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1051_1052
    • /
    • 2009
  • This paper deals with operational characteristic analysis of a single-phase PCS (Power Conditioning System) for PV (Photovoltaic) power generation system with AF (Active Filter) function. The theory of dq transformation has been applied to the control strategy of a single-phase PV power generation system to implement the AF function. Application of the virtual two-phase using phase-shift makes it possible to use the dq theory for the single-phase PV power generation system. The authors are sure that the proposed system is a very useful to compensate harmonics caused by nonlinear loads in a single-phase utility system. In this paper, not only a theoretical aspect of the single-phase PV-AF system is discussed, but also the DSP (Digital Signal Processor) based experiment results are presented to demonstrate the effectiveness of the single-phase PV-AF system.

  • PDF

RTDS based modeling technique of grid-connected photovoltaic generation system using HILS (Hardware In the Loop System) (HILS(Hardware In the Loop System)를 이용한 RTDS내 계통 연계형 태양광발전시스템 모델링기법)

  • Lee, Hyo-Geun;Kim, Sang-Yong;Park, Sang-Soo;Jang, Seong-Jae;Kim, Gyeong-Hun;Seo, Hyo-Ryong;Park, Min-Won;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1094_1095
    • /
    • 2009
  • 최근 분산전원 시스템들이 가정이나 공공기관 등에 많이 설치되면서 계통에 많은 문제점을 일으키고 있다. 이러한 문제점을 연구하기 위해서는 계통 등의 실제 시스템을 설치하여 실험을 하여야 하는데 학교 연구실 입장에서는 실제 시스템을 설치하여 실험하는데 한계가 있다. 그러나 실시간 전력 계통 모의장치 (Real Time Digital Simulator)를 이용하여 실시간으로 시스템을 시뮬레이션 할 경우 다양한 알고리즘의 적용이 가능하고, 고장, 전력계통 과도현상 등 계통에 일어날 수 있는 여러 가지 상황을 손쉽게 고려해 보는 것이 가능하다. 본 논문에서는 RTDS 내 계통 연계형 태양광 발전시스템을 실제 시스템과 유사하게 모델링하고, 실제 DSP (Digital Signal Processor) 를 이용하여 시스템을 실시간으로 운전하는 HILS (Hardware In the Loop System) 시스템을 구성하였다.

  • PDF