• Title/Summary/Keyword: DR image

Search Result 161, Processing Time 0.027 seconds

The Meaning of Hosting 2013 FDI Annual World Dental Congress in Seoul (우리나라의 FDI 세계치과의사총회(FDI Annual World Dental Congress) 유치의 의미)

  • Kim, Yeo-Gab;Kim, Tae-Hoon
    • The Journal of the Korean dental association
    • /
    • v.48 no.9
    • /
    • pp.647-652
    • /
    • 2010
  • FDI World Dental Federation is organization representing more than one million dentists worldwide with its more than 100 years of long history. Now FDI headquarter is located in Geneve, Switzerland and serves for developing health policy and continuing education programs, speaking as a unified voice for dentistry in international advocacy and supporting member association in oral health promotion activities worldwide. Korean Dental Association has been a member of FDI since 1959 and participated actively in the FDI's worldwide activities. Past Dr. Heung-Ryul Yoon was a president of FDI from 2003 for 2 years and we also have an experience in 1997 of hosting FDI Annual World Dental Congress successively in Seoul. The image of a country reflects the country's culture as well as affects to its economical and social development and it decides the national brand toward the world. Currently, Korean people realized that and put their efforts for promoting diverse aspects of Korea to the world such as multimedia culture called Han-Ryu, electric industry, automotive industry, sports represented by soccer. We have advanced technique and skill in various fields and now it's time to show ourself better to the world. It's same to the dentistry. It's true that Korean dentistry is top-class in the world and the dental industry is prosperous and also has best technique in the world. I think and strongly hope that the 2013 FDI Seoul Annual World Dental Congress would be best opportunity for Korean dentistry and dental industry to promote ourselves and make a big step to the world. Not only for the dentistry, it will also be very good chance to all the Korean people to improve Korean national brand. I believe that we can accomplish if we, all dental societies, stand together and join our effort to use this good chance the best. I know we can make it.

Image Quality Evaluation of Digital X-Ray Detector Using Amorphous Selenium Layer and Amorphous Silicon TFT Array (비정질 셀레늄층과 비정질 실리콘TFT배열을 사용하는 디지털 X-선 검출기의 영상특성 평가)

  • Kim, Chang-Won;Yoon, Jeong-Key;Kim, Jong-Hyo
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.219-226
    • /
    • 2008
  • In this study, we have conducted characterization of imaging performance for a flat panel digital X-ray detector using amorphous Selenium and a-Si TFT which was developed by the authors. The procedures for characterization were in concordance with internationally recommended standards such as IEC (international electrotechnical commission). The measures used for imaging performance characterization include response characteristic, modulation transfer function (MTF), detective quantum efficiency (DQE), noise power spectrum (NPS), and quantum limited performance. The measured DQEs at lowest and highest spatial frequencies were 40% and 25% respectively, which was superior to that of commercial products by overseas vendor. The MTF values were significantly superior to that of CR and indirect type DRs. The quantum limited performance showed the detector was limited by quantum noise at the entrance exposure level below 0.023 mR, which is sufficiently low for general X-ray examination.

  • PDF

Positive Effects of Diphlorethohydroxycarmalol (DPHC) on the Stability of the Integument Structure in Diet-Induced Obese Female Mice

  • Kim, Chae-lim;Cha, Sun-yeong;Chun, Min Young;Kim, Bumsoo;Choi, Min Young;Cheon, Yong-Pil
    • Development and Reproduction
    • /
    • v.19 no.3
    • /
    • pp.145-152
    • /
    • 2015
  • Diphlorethohydroxycarmalol (DPHC) is a known to modulate the expression of extracellular matrix (ECM) components in 3T3-L1. However, the possible role of DPHC in integument stability during obesity induction is not clear yet. We evaluated the effects of DPHC on collagen or elastic fiber quantity in integument during obesity induction with high-fat diet. The dorsal back integument sections were stained with hematoxylin-eosin, Masson trichrome, and Verhoff-Van Gieson. The intensities of collagen fibers and elastin fibers were analyzed with ImageJ. The number of fibroblasts was counted at ${\times}1,000$ fields. The number of fibroblast was increased by obesity induction, but DPHC suppressed it in a concentration-dependent manner both in lean and obese mice. On the other hand, the intensities of collagen fibers were increased by DPHC treatment in obese mice groups but not in lean mice groups. The intensities of collagen fibers of obese mice were lower than that of the lean mice in 0% group. However, the number became similar between lean and obese mice by the treatment of DPHC. The intensity of elastic fibers was increased in the lean mice with the concentration of DPHC. In the obese mice group, there were increasing patterns but only significant at 10% DPHC group. The intensity of elastic fibers of obese mice was higher than lean mice in 0%, 1%, and 10% groups. Histologically epithelial cells and follicle cells which were diffused nuclear staining forms were increased by DPHC treatment. The results suggest that the activity of integument cells during obesity induction can be modulated by DPHC.

Comparison of three behavior modification techniques for management of anxious children aged 4-8 years

  • Radhakrishna, Sreeraksha;Srinivasan, Ila;Setty, Jyothsna V;Murali, Krishna DR;Melwani, Anjana;Hegde, Kuthpady Manasa
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.19 no.1
    • /
    • pp.29-36
    • /
    • 2019
  • Background: An inability to cope with threatening dental stimuli, i.e., sight, sound, and sensation of airotor, manifests as anxiety and behavioral management problems. Behavior modification techniques involving pre-exposure to dental equipment will give children a first-hand experience of their use, sounds, and clinical effects. The aim of this study was to compare the techniques of Tell-Show-Play-doh, a smartphone dentist game, and a conventional Tell-Show-Do method in the behavior modification of anxious children in the dental operatory. Methods: Sixty children in the age group of 4-8 years, with Frankl's behavior rating score of 2 or 3, requiring Class I and II cavity restorations were divided into three groups. The groups were Group 1: Tell-Show-Play-doh; Group 2: smartphone dentist game; and Group 3: Tell-Show-Do technique and each group comprised of 20 children. Pulse rate, Facial Image Scale (FIS), Frankl's behavior rating scale, and FLACC (Face, Leg, Activity, Cry, Consolability) behavior scales were used to quantify anxious behavior. Operator compliance was recorded through a validated questionnaire. Results: The results showed lower mean pulse rates, lower FIS and FLACC scores, higher percentage of children with Frankl's behavior rating score of 4, and better operator compliance in both the Tell-Show-Play-doh and smartphone dentist game groups than in the conventional Tell-Show-Do group. Conclusion: The Tell-Show-Play-doh and smartphone dentist game techniques are effective tools to reduce dental anxiety in pediatric patients.

Use of an animated emoji scale as a novel tool for anxiety assessment in children

  • Setty, Jyothsna V;Srinivasan, Ila;Radhakrishna, Sreeraksha;Melwani, Anjana M;Krishna DR, Murali
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.19 no.4
    • /
    • pp.227-233
    • /
    • 2019
  • Background: Dental anxiety in children is a major barrier in patient management. If dental anxiety in pediatric patients is assessed during the first visit, it will not only aid in management but also help to identify patients who are in need of special care to deal with their fear. Nowadays, children and adults are highly interested in multimedia and are closely associated with them. Children usually prefer motion pictures on electronic devices than still cartoons on paper. Therefore, this study was conducted to evaluate a newly designed scale, the animated emoji scale (AES), which uses motion emoticons/animojis to assess dental anxiety in children during their first dental visit, and compare it with the Venham picture test (VPT) and facial image scale (FIS). Methods: The study included 102 healthy children aged 4-14 years, whose dental anxiety was measured using AES, VPT, and FIS during their first dental visit, and their scale preference was recorded. Results: The mean anxiety scores measured using AES, FIS, and VPT, represented as $mean{\pm}SD$, were $1.78{\pm}1.19$, $1.93{\pm}1.23$, and $1.51{\pm}1.84$, respectively. There was significant difference in the mean anxiety scores between the three scales (Friedman test, P < 0.001). The Pearson's correlation test showed a very strong correlation (0.73) between AES and VPT, and a strong correlation between AES and FIS (0.88), and FIS and VPT (0.69), indicating good validity of AES. Maximum number of children (74.5%) preferred AES. Conclusion: The findings of this study suggest that the AES is a novel and child-friendly tool for assessing dental anxiety in children.

Dust scattering simulation of far-ultraviolet light in the Milky Way

  • Jo, Young-Soo;Seon, Kwang-Il;Min, Kyoung-Wook;Jeong, Woong-Seob;Witt, Adolf N.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.46 no.1
    • /
    • pp.57.3-58
    • /
    • 2021
  • We performed three-dimensional Monte Carlo dust scattering radiative transfer simulations for FUV light to obtain dust scattered FUV images and compared them with the observed FUV image obtained by FIMS/SPEAR and GALEX. From this, we find the scattering properties of interstellar dust in our Galaxy and suggest the intensity of extragalactic background light (EBL) at FUV wavelength. The best-fit values of the scattering properties of interstellar dust are albedo = 0.38-0.04+0.04, g-factor = 0.55-0.15+0.10, and EBL = 138-23+21 CU for the allsky which are consistent well with the Milky Way dust model of Draine and direct measurements of Gardner et al., respectively. At the high Galactic latitude of |b|>10°, the observation is well fitted with the model of lower albedo = 0.35-0.04+0.06 and g-factor = 0.50-0.20+0.15. On the contrary, the scattering properties of interstellar dust show higher albedo = 0.43-0.02+0.02 and g-factor = 0.65-0.15+0.05 near the Galactic plane of |b|<10°. In the present simulation, recent three-dimensional distribution maps of interstellar dust in our Galaxy, stellar distances in the catalog of GAIA DR2, and FUV fluxes and/or spectral types in the TD-1 and Hipparcos star catalogs were used.

  • PDF

Optimization of Tube Voltage according to Patient's Body Type during Limb examination in Digital X-ray Equipment (디지털 엑스선 장비의 사지 검사 시 환자 체형에 따른 관전압 최적화)

  • Kim, Sang-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.5
    • /
    • pp.379-385
    • /
    • 2017
  • This study identifies the optimal tube voltages depending on the changes in the patient's body type for limb tests using a digital radiography (DR) system. For the upper-limp test, the dose area product (DAP) was fixed at $5.06dGy{\ast} cm^2$, and for the lower-limb test, the DAP was fixed at $5.04dGy{\ast} cm^2$. Afterwards, the tube voltage was changed to four different stages and the images were taken three times at each stage. The thickness of the limbs was increased by 10 mm to 30 mm to change in the patient's body type. For a quantitative evaluation, Image J was used to calculate the contrast to noise ratio (CNR) and signal to noise ratio (SNR) among the four groups, according to the tube voltage. For statistical testing, the statistically significant differences were analyzed through the Kruskal-Wallis test at a 95% confidence level. For the qualitative analysis of the images, the pre-determined items were evaluated based on a 5-point Likert scale. In both upper-limb and lower-limb tests, the more the tube voltage increased, the more the CNR and SNR of the images decreased. The test on the changes depending on the patient's body shape showed that the more the thickness increased, the more the CNR and SNR decreased. In the qualitative evaluation on the upper limbs, the more the tube voltage increased, the more score increased to 4.6 at the maximum of 55kV and 3.6 at 40kV, respectively. The mean score for the lower limbs was 4.4, regardless of the tube voltage. The more either the upper or lower limbs got thicker, the more the score generally decreased. The score of the upper limps sharply dropped at 40kV, whereas that of the lower limps sharply dropped at 50kV. For patients with a standard thickness, the optimized images can be obtained when taken at 45kV for the upper limbs, and at 50kV for the lower limbs. However, when the thickness of the patient's limbs increases, it is best to set the tube voltage at 50 kV for the upper limbs and at 55 kV for the lower limbs.

A Study on Bismuth tri-iodide for X-ray direct and digital imagers (직접방식 엑스선 검출기를 위한 $BiI_3$ 특성 연구)

  • Lee, S.H.;Kim, Y.S.;Kim, Y.B.;Jung, S.H.;Park, J.K.;Jung, W.B.;Jang, M.Y.;Mun, C.W.;Nam, S.H.
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.2
    • /
    • pp.27-31
    • /
    • 2009
  • Now a days, the Medical X-ray equipments has become digitalized from analog type such as film, cassette to CR, DR. And many scientists are still researching and developing the Medical X-ray equipment. In this study, we used the Bismuth tri-iodide to conversion material for digital X-ray equipments and we couldn't get the satisfying result than previous study, but it opened new possibility to cover the disadvantage of a-Se is high voltage aplly and difficultness of make. In this paper, we use $BiI_3$ powder(99.99%) as x-ray conversion material and make films that have thickness of 200um and the film size is $3cm{\times}3cm$. Also, we deposited an ITO(Indium Tin Oxide) electrode as top electrode and bottom electrode using a Magnetron Sputtering System. To evaluate a characteristics of the produced films, an electrical and structural properties are performed. Through a SEM analysis, we confirmed a surface and component part. And to analyze the electrical properties, darkcurrent, sensitivity and SNR(Signal to Noise Ratio) are measured. Darkcurrent is $1.6nA/cm^2$ and sensitivity is $0.629nC/cm^2$ and this study shows that the electrical properties of x-ray conversion material that made by screen printing method are similar to PVD method or better than that. This results suggest that $BiI_3$ is suitable for a replacement of a-Se because of the reduced manufacture processing and improved yield.

  • PDF

Evaluation of Image According to Exposure Conditions using Contrast-Detail Phantom for Chest Digital Radiography (흉부 디지털 방사선 촬영 시 C-D phantom을 이용한 촬영조건에 따른 영상 평가)

  • Lee, In-Ja;Kim, You-Hyun;Kim, Chang-Nam;Lee, Chang-Yeob;Park, Kye-Yeon
    • Journal of radiological science and technology
    • /
    • v.32 no.1
    • /
    • pp.25-32
    • /
    • 2009
  • To find out proper photographing conditions in the chest DR imaging, the evaluation of images using the C-D phantom was carried out on relationship of identification capability, graininess, and exposure ratio. The conclusions were obtained as follows. 1. The patient's entrance skin Exposure (ESE) was decreased as tube voltage was increased. 2. According to the tube voltage change, the C-D phantom's identification capability of the exposure conditions was most visible at 110 kVp. 3. The identification capability according to the exposure ratio (mAs) change was most visible at 90 kVp for 0.5 times of low exposure ratio and at 110 kVp for 1.5 times. Therefore, it is known that the images were able to be better identified at a high exposure than a low exposure. 4. The graininess according to the exposure ratio at tube voltage of 110 kVp resulted in the best thing at 1.5 times of ratio when the exposure ratio was 1.5 times increased and the tube voltage was changed, the graininess showed the best result at 110 kVp. Therefore, the patient's exposure dose was low when kVp was increased and the adequate kVp was found to be 110. The image was better identified when exposure ratio was 1.5 times compared to 1.0 times. The graininess was also good when the exposure ratio became 1.5 times. The tube voltage was good at 110 kVp. However, once the exposure ratio is increased, the amount of radiation dose that the patients received get increased, so that the exposure condition has to be thoroughly considered.

  • PDF

Measurement and Evaluation of Scatter Fractions for Digital Radiography with a Beam-Stop Array (Beam-Stop Array를 이용한 DR에서의 Scatter Fraction 측정 및 효용성 평가)

  • Choi, Yu-Na;Cho, Hyo-Min;Kim, Yi-Seul;An, Su-Jung;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.9-15
    • /
    • 2010
  • Scatter radiation considerably affects radiographic image quality by reducing image contrast and contributing to a non-uniform background. Images containing a large portion of scatter radiation may result in an incorrect diagnosis. In the past few years, many efforts have been made to reduce the effects of scatter radiation on radiographic images. The purpose of this study is to accurately measure scatter fractions and evaluate the effectiveness of beam-stop arrays. To measure scatter fraction accurately, a beam-stop array and the SFC (Scatter Fraction Calculator) program were developed. Images were obtained using the beam-stop array for both an anti-scatter technique with an anti-scatter grid and an air gap technique. The scatter fractions of the images were measured using the SFC program. Scatter fractions obtained with an anti-scatter grid were evaluated and compared to scatter fractions obtained without an anti-scatter grid. Scatter fractions were also quantitatively measured and evaluated with an air gap technique. The effectiveness of the beam-stop array was demonstrated by quantifying scatter fractions under various conditions. The results showed that a beam-stop array and the SFC program can be used to accurately measure scatter fractions in radiographic images and can be applied for both developing scatter correction methods as well as systems.