교합장치가 발음시 하악위 및 하악의 비틀림 회전운동에 미치는 영향 (Effects of Occlusal Appliance on the Mandibular Position and the Mandibular Rotational Torque Movement during Speech)

  • 김문규;한경수;김종영;양근영
    • Journal of Oral Medicine and Pain
    • /
    • 제26권1호
    • /
    • pp.59-73
    • /
    • 2001
  • This study was performed to investigate the effects of occlusal appliance on the mandibular position and the mandibular rotational torque movement during speech. For this study, 20 patients with temporomandibular disorders(TMDs) and 20 normal subjects without any signs and symptoms in the masticatory system were selected as the patient group and as the normal group, respectively. Biopak $system^{(R)}$(Bioresearch Inc., Milwaukee, USA) and a sentence of 'Sue is missing her house' were used for recording and for observing of speech pattern. There were five mandibular positions observed in this study, that is, mandibular rest position, 'ssi', 'her', 'ha', and 's' speech position. In each position, slant and A-P distance in sagittal plane, vertical distance and lateral distance in frontal plane were measured. Amount of the mandibular rotational torque movement were measured at 'her', 'ha' speech position and for all through speech movement. Centric relation splint(CRS) was placed in both groups, but anterior or posterior bite plane were placed in normal subjects only. Data collected were processed and analysed by SPSS windows program. The results of this study were as follows : 1. Mandibular positions in both groups were not different before adaptation, with CRS, and after removal, but total amount of the mandibular rotational torque movement was greater in patients. 2. Mandible was slightly placed anteriorly with CRS at 'her' and 'ha' speech position in patients, but was placed anteriorly at all the five positions in normal subjects. 3. Difference with type of occlusal appliance in normal subjects were noted only for vertical distance at 'ssi' and 'ha' speech position, and the distance with CRS were more than that with posterior bite plane. 4. Mandibular rotational torque movement at 'her' and 'ha' speech position was greater in patients, but the difference was disappeared after appliance removal. And the torque movement was greater at 'ha' speech position than that at 'her' speech position in frontal plane. It could be concluded that the adaptation of occlusal appliance showed a tendency to locate the mandible anteriorly during speech in both groups, but did not affect total mandibular rotational torque movement which was greater in patients.

  • PDF

Fitts' Law for Angular Foot Movement in the Foot Tapping Task

  • Park, Jae-Eun;Myung, Ro-Hae
    • 대한인간공학회지
    • /
    • 제31권5호
    • /
    • pp.647-655
    • /
    • 2012
  • Objective: The purpose of this study was to confirm difference between angular foot movement time and existing foot Fitts' law predicting times, and to develop the angular foot Fitts' law in the foot tapping task. Background: Existing studies of foot Fitts' law focused on horizontal movement to predict the movement time. However, when driving a car, humans move their foot from the accelerator to the brake with a fixed heel. Therefore, we examined the experiment to measure angular foot movement time in reciprocal foot tapping task and compared to conventional foot Fitts' law predicting time. And, we developed the angular foot Fitts' law. Method: In this study, we compared the angular foot movement time in foot tapping task and the predicted time of four conventional linear foot Fitts' law models - Drury's foot Fitts' law, Drury's ballistic, Hoffmann's ballistic, Hoffmann's visually-controlled. 11 subjects participated in this experiment to get a movement time and three target degrees of 20, 40, and 60 were used. And, conventional models were calculated for the prediction time. To analyze the movement time, linear and arc distance between targets were used for variables of model. Finally, the angular foot Fitts' law was developed from experimental data. Results: The average movement times for each experiment were 412.2ms, 474.9ms, and 526.6ms for the 89mm, 172mm, and 253mm linear distance conditions. The results also showed significant differences in performance time between different angle level. However, all of conventional linear foot Fitts' laws ranged 135.6ms to 401.2ms. On the other hand, the angular foot Fitts' law predicted the angular movement time well. Conclusion: Conventional linear foot Fitts' laws were underestimated and have a limitation to predict the foot movement time in the real task related angular foot movement. Application: This study is useful when considering the human behavior of angular foot movement such as driving or foot input device.

관성센서를 이용한 양궁자세 분석 시스템 구축 및 평가 (Development and Evaluation Archery Posture Analysis System using Inertial Sensor)

  • 조우형;권성호;권장우;이상민
    • 전기학회논문지
    • /
    • 제65권10호
    • /
    • pp.1746-1754
    • /
    • 2016
  • In this paper, we provide a development and evaluation method for an archery posture analyzing system, using an inertial sensor. The system was developed using LabVIEW2014 by National Instruments and evaluated using the DTW algorithm. To convert the voltage value of the inertial sensor into a physical value, a coordinate transformation matrix bias was applied. To evaluate the similarity of movement in archery shooting, the DTW distance was calculated and similarity was confirmed based on simple mechanical movement, the same person's shooting movement, shooting movement with another person, and the noise signal. The average similarity comparison results were as follows: simple mechanical movement was 17.05%, the same person's shooting movement was 26.48%, shooting movement with another person was 62.8%, and the noise signal was 328.5%; a smaller value indicates a higher level of similarity. We confirmed the possibility of analyzing the archery posture using 3-axis acceleration of the inertial sensor. We inferred that the proposed method might be important means for assessing shooting skills, evaluation of archer's progress, and finding talented archers in advance.

Near-body Interaction Enhancement with Distance Perception Matching in Immersive Virtual Environment

  • Yang, Ungyeon;Kim, Nam-Gyu
    • Journal of Multimedia Information System
    • /
    • 제8권2호
    • /
    • pp.111-120
    • /
    • 2021
  • As recent virtual reality technologies provide a more natural three-dimensional interactive environment, users naturally learn to explore space and interact with synthetic objects. The virtual reality researcher develops a technique that realizes realistic sensory feedback to get appropriate feedback to sense input behavior. Although much recent virtual reality research works extensively consider the human factor, it is not easy to adapt to all new virtual environment contents. Among many human factors, distance perception has been treated as very important in virtual environment interaction accuracy. We study the experiential virtual environment with the feature of the virtual object connected with the real object. We divide the three-dimensional interaction, in which distance perception and behavior have a significant influence, into two types (whole-body movement and direct manipulation) and analyze the real and virtual visual distance perception heterogeneity phenomenon. Also, we propose a statistical correction method that can reduce a near-body movement and manipulation error when changing the interaction location and report the experiment results proving its effectiveness.

Comparison on postural control between abdominal draw-in maneuver and abdominal expansion maneuver in persons with stroke

  • Choi, Ho-Suk;Shim, Yu-Jin;Shin, Won-Seob
    • Physical Therapy Rehabilitation Science
    • /
    • 제5권3호
    • /
    • pp.113-119
    • /
    • 2016
  • Objective: The effect of abdominal expansion maneuver (AEM) and abdominal draw-in maneuver (ADIM) on postural control in an unsupported position in stroke patients. Design: Randomized controlled trial. Methods: A total of 36 persons with hemiplegic stroke participated in this study. The subjects were randomly divided into an AEM experimental group (n=12), an experimental ADIM group (n=12), and a control group (n=12). We collected the general characteristics of all subjects and the pre-test results before the intervention and after 4 weeks of the intervention. The trunk stabilization training of the ADIM and AEM group were performed 15 minutes a day, 3 times a week for 4 weeks, and general physical therapy was performed 2 times a day, 30 minutes per session, 5 times a week for all three groups. The control group received joint mobilizations, muscle strengthening, endurance strengthening, and gait exercises along with treatment of the central nervous system, such as neuro-developmental treatment, mat, and gait training. The AEM is an inspiratory phase of tidal breathing expanding the lateral lower ribcage in a lateral direction with minimal superior movements of the chest. Then the lower abdomen expands and the navel moves in an anterior-caudal direction. The ADIM is a repeated contraction and relaxation of the anal sphincter during inspiration. The navel pulls the lower abdomen to the direction of the spine without the movement of the trunk and pelvis. Results: Before and after the interventions, medial-lateral axis movement distance, anterior-posterior axis movement distance, sway mean velocity, and sway area 95% was a statistically significant change in all three groups (p<0.05). The post-hoc test showed a significant improvement in medial-lateral axis movement distance, anterior-posterior axis movement distance, sway mean velocity, and sway area in the AEM group compared with the control group, and in the ADIM group compared with the control group (p<0.05). Conclusions: In conclusion, both AEM training and ADIM training are necessary interventions to maintain the independent sitting position according to the characteristics of the patient.

하악과두 운동 평가를 위한 경두개방사선사진과 파노라마 TMJ 방사선사진의 비교 (A comparison of transcranial with panoramic TMJ radiographs to assess the movement of the mandibular condyle)

  • 오종화;김재덕;김진수
    • Imaging Science in Dentistry
    • /
    • 제38권2호
    • /
    • pp.89-93
    • /
    • 2008
  • Purpose: To evaluate the difference of the movement of the mandibular condyles between trans cranial and panoramic TMJ radiographs to view the movement of the mandibular condyles. Materials and Methods: Thirty-four paired transcranial and panoramic TMJ radiographs of patients were used to evaluate the movement of the mandibular condyle. The distances, from the most superior point of the mandibular condyle to the most inferior point of the articular eminence on both radiographs, were measured. The measurements were taken at closed state and maximum opening state of each radiograph on both side. Differences between matched pairs were analysed by paired t-test, with significance established at P<0.05. Results and Conclusion: The mean distance, from the most superior point of the mandibular condyle to the most inferior point of the articular eminence on both radiographs, was statistically different at each side (P<0.05). At closing state, the mean distance measured on panoramic TMJ radiographs was longer than on transcranial radio-graphs (0.85 mm at right side, 1.20 mm at left side). But at maximum opening state, the mean distance on transcranial radiographs was longer (1.00 mm at right side, 0.62 mm at left side) than panoramic TMJ radiographs.

  • PDF

고분해능을 갖는 간섭계형 리니어 스케일 제작 및 성능 평가 (Implementation and performance estimation of interferometer-type linear scale with high-resolution)

  • 김수진;은재정;최평석;권오영
    • 융합신호처리학회논문지
    • /
    • 제2권3호
    • /
    • pp.86-92
    • /
    • 2001
  • 미소 단위로 이동하는 물체의 이동 거리를 측정하기 위한 정밀 측정기기, 반도체 제조 장치, 공작기계 등의 위치 제어는 매우 중요한 요건이며, 이러한 장치들의 이동거리 측정에 대한 정확도는 전체 시스템의 성능을 좌우하게 된다. 따라서 정밀기기에서 이동 거리를 고정밀도로 측정할 수 있는 센싱 디바이스가 요구되며, 여기에는 레이저 간섭계의 분해능에 준하는 분해능을 갖고, 경제성 및 디지털 인터페이스에 대한 장점을 갖는 광학식 엔코더가 사용될 수 있다. 본 논문에서는 이동 거리를 측정하기 위해 회절 원리를 기초로한 고분해능 및 디지털 인터페이스가 용이한 간섭계형 리니어 스케일을 실험적으로 구성하였다. 그리고 이 리니어 스케일에서 발생된 간섭 신호는 제작된 광 검출기와 신호처리 회로를 통해 디지털화하였다. 그 결과 실험적으로 구성된 간섭계형 리니어 스케일은 스케일의 이동에 대하여 어떠한 분주 회로도 추가하지 않고, 단지 쉬운 광학적 구성으로 0.5$\mu\textrm{m}$의 분해능을 얻었다.

  • PDF

두부자세 및 교합장치에 따른 연하운동의 변화 (Effects of Head Posture and Occlusal Splint on Swallowing Movement)

  • Sung-Jin Moon;Kyung-Soo Han
    • Journal of Oral Medicine and Pain
    • /
    • 제21권1호
    • /
    • pp.55-65
    • /
    • 1996
  • This study was performed to investigate the effects of head posture and occlusal splint on the vertical dimension in mandibular rest position and swallowing. Thirty health dental students ware selected lot this study and BioEGNⓡ(Bioresearch Inc., USA) was used for measuring interocclusal distance during rest - swallowing - rest - tapping movement. This swallowing movements were observed in both normal head posture(NHP) and forward head posture (FHP). Thickness of occlusal splint was about 2mm at posterior molar area and even tooth contact were achieved on light biting. The four mandibular positions at which interocclusal distance measured were swallowing position, after swallowing position in which interocclusal distance was maximum, rest position follows swallowing, and tapping position after rest. Changes of distance in each position were measured for three mandibular planes, that is, sagittal, frontal, and horizontal plane, respectively. The results obtained were as follows : 1. In normal head posture, the mandible was raised 1.03mm without splint, and 0.77mm with splint on swallowing, and there was no significant difference between the two. In horizontal plane, however, mandible was displaced more anteriorly in both swallowing position and tapping position with splint. 2. In forward head posture, the mandible was less raised with splint on swallowing, but features in horizontal plane were almost same as those in normal head posture. 3. In natural dentition, significant difference between NHP and FHP were observed in horizontal plane trajectory for swallowing and tapping position. But the difference for same positions were observed in frontal trajectory with splint. 4. Total amount of mandibular movement of two groups classified with sagittal interocclusal distance of swallowing position generally showed significant difference between the higher and the lower height group in head posture without splint. 5. Correlationship among total amount of mandibular movement for three mandibular planes were observed between sagittal plane and horizontal plane, and between sagittal plane and frontal plane in head posture without splint.

  • PDF

3차원 가상착의를 활용한 방호복 평가 (Evaluation of Protective Clothing Using 3D Virtual Fitting)

  • 이옥경;이희란
    • 한국염색가공학회지
    • /
    • 제35권2호
    • /
    • pp.107-120
    • /
    • 2023
  • The purpose of this study was to analyze the patterns of D level protective clothing, improve their ease of movement by modifying the patterns, and validate the effectiveness of the improvements through 3D virtual fitting and subjective wearing evaluations. Based on previous studies that identified numerous complaints, the patterns of the neck, armpit, and waist areas were modified, resulting in the development of new patterns. To compare and analyze the improved protective clothing with the basic protective clothing, stress and strain were examined after 3D virtual fitting. Additionally, to assess the clothing's allowance, the overall distance between the avatar and the protective clothing, as well as the sectional circumference length and distance of each avatar body part, were measured. Furthermore, the improved protective clothing was manufactured, and a subjective wearing evaluation was conducted with ten males in their twenties as participants. The results showed that the improved protective clothing had evenly distributed stress, larger sectional circumference, and lower average cavity distance. The subjective wearing evaluation also revealed that the suit with improved patterns exhibited superior size suitability, reduced pulling sensation in different body parts, and increased ease of movement. In conclusion, this study confirmed that even minimal pattern modifications can enhance the functionality of protective clothing, alleviating discomfort for wearers.

Visual Measurement of Pile Movement for the Foundation Work using a High-Speed Line-Scan

  • Lim, Mee-Seub;Lim, Joon-Hong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.1802-1807
    • /
    • 2004
  • When a construction company builds a high structure, many piles should be driven into the ground by a hammer whose weight is 7,000 Kg in order to make the ground under the structure safe and strong. So, it is essential to determine whether a pile is penetrated into the ground enough to support the weight of the structure since ground characteristics at different locations are different each other. This paper proposes a visual measurement system for pile rebound and penetration movement including vibration using a high-speed line-scan camera and a specially designed mark to recognize two-dimensional motion parameters of the mark using only a line-scan camera. A mark stacking white and black right-angled triangles is used for the measurement, and movement information for vertical distance, horizontal distance and rotational angle is determined simultaneously

  • PDF