• 제목/요약/키워드: DISCHARGE

검색결과 13,061건 처리시간 0.034초

무성방전의 중첩을 이용한 다중방전형 오존발생기의 오존생성수율 개선 (Improvement of Ozone Yield by a Multi-Discharge Type Ozonizer Using Super position of Silent Discharge Plasma)

  • 송현직;이동헌;오진훈;박성욱;서영택
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.88-91
    • /
    • 2004
  • In order to improve ozone generation, we experimentally investigated the silent discharge plasma and ozone generation characteristics of a multi-discharge type ozonizer. Ozone in a multi-discharge type ozonizer is generated by superposition of a silent discharge plasma, which is simultaneously generated in separated discharge spaces. A multi-discharge type ozonizer is composed of three different kinds of superposed silent discharge type ozonizers, depending on the method of applying power to each electrode. We observed that the discharge period of the current pulse for a multi-discharge type ozonizer can be longer than that of silent discharge type ozonizer with two electrodes and one gap.Hence, ozone generation is improved up to 17185 ppm and 783 g/kwh for the superposed silent discharge type ozonizer for which an AC high voltages with a 180 phase difference were applied to the internal electrode and the external electrode, respectively, with the central electrode being ground

  • PDF

Electrochemical Properties of Acetylene Black/Multi-walled Carbon Nanotube Cathodes for Lithium Thionyl Chloride Batteries at High Discharge Currents

  • Song, Hee-Youb;Jung, Moon-Hyung;Jeong, Soon-Ki
    • Journal of Electrochemical Science and Technology
    • /
    • 제11권4호
    • /
    • pp.430-436
    • /
    • 2020
  • Lithium thionyl chloride (Li/SOCl2) batteries exhibit the highest energy densities seen in commercially available primary batteries because of their high operating voltages and discharge capacities. They are widely used in various extreme environments; however, they show signs of degradation at high discharge currents. The discharge performance of Li/SOCl2 is considered to be greatly dependent on the carbon materials used in the cathode. Therefore, suitable carbon materials must be chosen to improve discharge performances. In this work, we investigated the discharge properties of Li/SOCl2 batteries in which the cathodes contained various ratios of acetylene black (AB) and multi-walled carbon nanotubes (MWCNTs) at high discharge currents. It was confirmed that the MWCNTs were effectively dispersed in the mixed AB/MWCNT cathodes. Moreover, the discharge capacity and operating voltage improved at high discharge currents in these mixed cathodes when compared with pure AB cathodes. It was found that the mesopores present in the cathodes have a strong impact on the discharge capacity, while the macropores present on the cathode surface influence the discharge properties at high discharge rates in Li/SOCl2 batteries. These results indicate that the ratio of mesopores and macropores in the cathode is key to improving the discharge performance of Li/SOCl2 batteries, as is the dispersion of the MWCNTs.

KSTAR 제1벽 세정을 위한 방전세정 시스템 설계 (Design of the discharge cleaning system for KSTAR vacuum vessel)

  • 정승호;인상렬
    • 한국진공학회지
    • /
    • 제16권5호
    • /
    • pp.383-387
    • /
    • 2007
  • 본 논문에서는 KSTAR 토카막 진공용기의 세정을 위한 방전세정 시스템의 설계에 대해 기술하였다. 먼저 방전세정효율에 영향을 주는 매개변수들에 대해 논의하였으며. 실제 설계에서 직류방전 보다 낮은 압력에서 방전이 시작되고 유지되며 따라서 세정효율이 높은 RG 방전(RF-assisted DC glow discharge) 방법을 채택하였다. 그리고 방전세정의 균일성을 위해 두 개의 방전 전극을 진공용기의 진단포트(A,I-port)에 설치하였다. 설계된 방전세정 시스템은 KSTAR 진공용기 내벽 세정뿐만 아니라 제1벽의 연료재순환(fuel recycling)이나 보론화 처리(boronization)등의 연구에도 응용될 수 있다.

통원 수술환자의 안전한 귀가 결정을 위한 퇴실기준에 관한 연구 (A Study about Discharge Criteria to Determine Patients' Readiness for Safe Return to Home after Ambulatory Surgery)

  • 윤계숙;김은경;정소현;이승주;정미경;이영미
    • 임상간호연구
    • /
    • 제18권3호
    • /
    • pp.435-446
    • /
    • 2012
  • Purpose: This study was conducted to compare three discharge criteria; 1) discharge criteria of S Hospital determined by nurses, 2) discharge readiness determined by patients, and 3) the Modified Post-Anesthetic Discharge Scoring System (MPADSS). The usefulness of MPADSS as a discharge criteria for the patients'safe return to home after ambulatory surgery was also evaluated. Methods: A total of 370 day surgery cases were investigated. The MPADSS was employed in every 30 min. in parallel with discharge readiness assessment by nurses and patients. The percentage of the patients who were categorized as being ready to discharge were compared according to three discharge criteria. Results: The percentage of patients scored to be as MPADSS > 9 in 30 min, 60 min, 90 min were 96.5%, 99.5%, 100%respectively. Whereas 11.1%, 44.3%, 71.1%of patients rated themselves as being ready to discharge and 2.7%, 23.5%, 54.3% of patients actually discharged by nurses according to discharge criteria of S Hospital. Conclusion: Nurses tend to keep patients longer in the hospital when compared to the patient's own assessment about their readiness to home and to that of MPADSS. Faster discharge in the evening than day time suggests patient discharge can be influenced by nursing factors. This brings out the importance of scoring system to determine the safe discharge. The MPADSS could be a useful tool in evaluating patients for safe discharge.

슬릿 유전체 장벽을 갖는 선대 평판형 방전장치의 방전 및 오존 발생특성 (Discharge and Ozone Generation Characteristics of a Wire-Plate Discharge System with a Slit Barrier)

  • 문재덕;정재승
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권9호
    • /
    • pp.421-426
    • /
    • 2005
  • A wire-plate discharge system with a slit barrier has been proposed and investigated experimentally by focusing on the discharges on the slit barrier and ozone generation characteristics. This wire-plate discharge system with a slit barrier can generate an intensive corona discharges, and produce corona discharge twice, once from the corona wire electrode and second time from the surface and the slits of the slit dielectric barrier. As a result this propose wire-plate discharge system with the slit barrier can produce greatly increased ozone than without the slit barrier. This type of wire-plate discharge system with the slit barrier could be used for effective ozone generation as a means with retard to the removal of pollutant gas

펄스 코로나 반응기에서 방전극의 배열에 따른 탈질율 연구 (A Study on the NOx Removal Rate by Arrangement of Discharge Electrode in Pulsed Corona Discharge Reactor)

  • 최민;박소진;위영호
    • 한국대기환경학회지
    • /
    • 제19권3호
    • /
    • pp.315-323
    • /
    • 2003
  • The goal of this study if the optimization of discharge electrode for pulsed corona discharge reactor located in thermal power plant. For this purpose, we have performed experiments of NO$_{x}$ removal rate by exchange of discharge electrode diameter and arrangement of discharge electrode in the non -thermal plasma reaction facility using a ethylene as additive. If the diameter and numbers of discharge electrode were larger, the NO$_{x}$ removal rate was higher. From these results, if we optimized the shape and installed numbers of discharge electrode at the pilot plant, we could increase the NO$_{x}$ removal rate with less amount of additive than current amount.mount.

역극성 전압인가와 나사형 전극을 이용한 복합방전형 오존발생기의 특성 (The Characteristics of the Complex Discharge Type Ozonizer using Applied Voltage of a Inverse-Polarity and a Screw Type Electrode)

  • 송현직
    • 조명전기설비학회논문지
    • /
    • 제25권9호
    • /
    • pp.80-85
    • /
    • 2011
  • In this paper, complex discharge type ozonizer with a screw type electrode has been designed and manufactured for environmental improvement using low power and high efficency ozoniazer. The complex discharge type ozonizer is equipped with three electrodes{central electrode(CE), internal electrode(IE) and external electrode(EE)}. Ozone of the complex discharge type ozonizer is generated by superposition of silent discharge and surface discharge in discharge space as a screw type CE and IE are respectively applied to AC high voltage of inverse-polarity has $180[^{\circ}]$ phase difference, EE is common electrode. In this time, when oxygen has been used as supplied gas, the maximum values of ozone concentration, ozone generation and ozone yield were obtained as 8,334[ppm], 3,249[mg/h] and 65.3[g/kwh].

AC PDP의 온도에 따른 방전 특성 연구 (A Study on the Temperature-Dependent Discharge Characteristics in Alternating Current Plasma Display Panel)

  • 이석현;김지용
    • 전기학회논문지
    • /
    • 제56권3호
    • /
    • pp.577-582
    • /
    • 2007
  • The plasma display panel is an image expression display using gas discharge plasma. However, gas discharge characteristics vary with temperature as gas discharge is sensitive to temperature. The discharge time lag extends a lot in low temperature and it is known as the cause which hinders high speed addressing which is essential for the size enlargement of the panel. Accordingly this research aims at identifying the temperature-dependent discharge characteristic. The lower temperature becomes, the longer addressing discharge time lag becomes. Particularly the statistical time lag extends much in low temperature. The increasing of electric field shortens discharge time lag in low temperature. Also, when priming particles are sufficiently supplied, stable discharge can be performed regardless of the influence of temperature.

3전극이 부설된 틈새 장벽방전형 플라즈마장치의 코로나 방전 및 오존발생 특성 (Corona Discharge and Ozone Generation Characteristics of a Slit Dielectric Barrier Discharge Type Plasma Reactor with a Third Electrode)

  • 문재덕;정재승
    • 전기학회논문지
    • /
    • 제56권3호
    • /
    • pp.583-587
    • /
    • 2007
  • Corona discharge and ozone generation characteristics of a slit dielectric barrier discharge type wire-plate plasma reactor with a third electrode have been investigated. When a third electrode is installed on a slit of the slit barrier, where an intense corona discharge occurs, it is found that a significantly increased ozone output could be obtained. This, however, indicates that the third electrode can activate the corona discharges both of the discharge wire and the slit of the slit barrier in the plasma reactor. As a result, a thin stainless wire, used as the third electrode has a strong effect to influence the corona discharge of the slit and corona wire, especially to the negative corona discharge. Higher amounts of the output ozone and ozone yield, about 1.27 and 1.29 times for the negative corona discharge, can be obtained with the third electrode, which reveals the effectiveness of the third electrode.

UPS용 절연재료의 부분방전 특성 (Partial discharge properties of insulating materials for UPS)

  • 이덕진
    • 한국컴퓨터산업학회논문지
    • /
    • 제4권12호
    • /
    • pp.1013-1020
    • /
    • 2003
  • 본 논문에서는 소형변압기에 적용되는 절연재료의 전기적 신뢰성을 평가하기 위하여 시간변화에 따른 방전전하량 특성을 조사하였다. 10[kV]의 교류전압을 인가한 후 $\pm$5[V]의 전압으로 변환시켜 A/D변환기를 통해 컴퓨터로 데이터를 저장하였으며 인가된 파형의 한주기 및 방전전하량 값을 64개로 분할하고 10초 동안 발생한 전하량을 위상별로 누적하였다. 이 값들을 분석한 결과, 전압인가시간이 증가함에 따라 방전발생빈도수 및 총 방전전하량은 감소하였으며 평균 방전전하량의 변화폭이 완만해짐을 알 수 있었다.

  • PDF