• 제목/요약/키워드: DIAMETER

검색결과 19,160건 처리시간 0.044초

An upper bound analysis for closed-die forging of spur gear forms (스퍼어 기어의 밀폐단조에 관한 상계해석)

  • Park, J.C.;Hur, K.D.;Park, J.U.
    • Journal of the Korean Society for Precision Engineering
    • /
    • 제11권4호
    • /
    • pp.26-37
    • /
    • 1994
  • A kinematically admissible velocity field for the numerical analysis of closed-die forging process of spur gear is proposed. The velocity field is divided into three regions of deformation. In the analysis, the involute curve is approximated to be straight line and the upper-bound method is used to calculate energy dissipation rate. A constant frictional frictional factor has been assumed on the contacting surfaces. The effects of root diameter, number of teeth, and friction factor are determined on the relative forging pressure. The frictionless relative pressure is independent of root diameter for the same number of teeth, but increases with the number of teeth on a given root diameter. In the presence of friction, the relative forging presure increasing root diameter at the start of forging, but decreases with increasing root diameter in the processing of forging.

  • PDF

A Study on Microencapsulation of Perfume and Antibiotics by In-situ Polymerzation(I) (In-situ 중합에 의한 향료와 항균제의 마이크로 캡슐화에 관한 연구(I))

  • 박차철;정영진;박찬영;민성기
    • Textile Coloration and Finishing
    • /
    • 제9권6호
    • /
    • pp.68-73
    • /
    • 1997
  • Urea/formaldehyde(UF) and melamine/formaldehyde(MF) microcapsules containing perfume and 2,4,4'-trichlroro-2-hydroxydiphenyl ether(DP) were prepared by the in-situ polymerization using urea and formaldehyde. Effects of dispersing agent, accelerating agent, formaldehyde, agitation speed on the mean diameter of microcapsules were investigated. The diameter of microcapsule was decreased with increasing dispersing agent concentration. A slight increase in the diameter was observed when the concentration of film forming material was increased. The diameter of microcapsule was decreased with increasing agitation speed up to 8,000rpm. The mean diameters of UF microcapsule prepared at 8,000rpm are about 3$\mu$m. A slight decrease in the diameter was observed when the concentration of resorcinol was increased.

  • PDF

Improved Path Authorization of Diameter Base Protocol (Diameter Base Protocol의 향상된 경로 권한검증 기법)

  • Yu, Hui-Jong;Kim, Hyun-Gon
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 한국정보처리학회 2004년도 춘계학술발표대회
    • /
    • pp.1141-1144
    • /
    • 2004
  • Diameter Base 프로토콜은 Diameter 노드라면 반드시 지원해야 하는 기본 프로토콜이다. 현재 Diameter Base 프로토콜은 IETF RFC 3588로 표준화되었으나 여전히 논의되어야 할 문제점이 존재하며 IETF WG Mailing List에서 이에 관한 논의가 진행되고 있다. 경로 권한 검증 문제는 이미 IETF WG Mailing List에서 일부 언급되었으나 충분한 논의가 이루어지지 못한 상태이다. 따라서 RFC 3588 내에서 정의한 내용들에 서로 모순되고 비효율적인 기능들이 존재한다. 본 논문에서는 RFC에 새롭게 추가된 기능인 경로 권한 검증 기능의 문제점에 대해 분석하여 표준에 벗어나지 않으며 보다 효율적으로 개선된 방안을 제시한다.

  • PDF

Optimization of Design of Plasma Process for Water Treatment using Response Surface Method (반응표면분석법을 이용한 수처리용 플라즈마 공정 설계의 최적화)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Korean Society on Water Environment
    • /
    • 제27권5호
    • /
    • pp.617-624
    • /
    • 2011
  • In order to confirm the creation of the OH radical which influences to RNO bleaching processes, it experimented using laboratory reactor of dielectric barrier discharge plasma (DBDP). The experiments performed in about 4 kind process variables (diameter of ground electrode, diameter of discharge electrode, diameter of quartz tube and effect of air flow rate) which influence to process. In order to examine optimum conditions of design factors as shown in Box-Behnken experiment design, ANOVA analysis was conducted against four factors. The actual RNO removal at optimized conditions under real design constraints were obtained, confirming Box-Behnken results. Optimized conditions under real design constraints were obtained for the highest desirability at 1, 1 mm diameter of ground and discharge electrode, 6 mm diameter of quartz tube and 5.05 L/min air flow rate, respectively.

Effect of a Tube Diameter on Single Bubble Condensation in Subcooled Flow (튜브 직경에 따른 과냉각 유동 내 단일 기포 응축의 영향)

  • Sun Youb Lee;Cong-Tu Ha;Jae Hwa Le
    • Journal of the Korean Society of Visualization
    • /
    • 제21권1호
    • /
    • pp.47-56
    • /
    • 2023
  • Bubble condensation, which involves the interaction of bubbles within the subcooled liquid flow, plays an important role in the effective control of thermal devices. In this study, numerical simulations are performed using a VOF (Volume of Fluid) model to investigate the effect of tube diameter on bubble condensation. As the tube diameter decreases, condensation bubbles persist for a long time and disappear at a higher position. It is observed that for small tube diameters, the heat transfer coefficients of condensation bubbles, which is a quantitative parameter of condensation rate, are smaller than those for large tube diameters. When the tube diameter is small, the subcooled liquid around the condensing bubble is locally participated in the condensation of the bubble to fill the reduced volume of the bubble due to the generation of a backflow in the narrow space between the bubble and the wall, so that the heat transfer coefficient decreases.

Effects of Acupuncture on the Muscle Fatigue Recovery in Different Diameters of Needle (침체굵기에 따른 자침의 근피로도 회복에 미치는 영향)

  • Hwang, Yo-Sun;Park, Chin-Su;Koo, Sungtae
    • Korean Journal of Acupuncture
    • /
    • 제29권4호
    • /
    • pp.634-642
    • /
    • 2012
  • Objectives : The aim of the study is to find out whether effect of acupuncture is depending on the diameter of needle, which is a possible component of dose of acupuncture needling. Methods : To compare acupuncture effects in different diameters of needle, we measured the changes in muscle fatigue recovery using surface electromyogram(sEMG) in healthy 8 volunteers. Muscle fatigue was induced by 20 times sit-up for 1 min. Immediately after induction of muscle fatigue, acupuncture needle was inserted into ST36 or ST25 for 10 min by diameters of 0.20 mm, 0.30 mm, or 0.40 mm needles. The sEMG recording was followed by acupuncture for 30 min. As a control group, sEMG was recorded for the same period at rest after muscle fatigue induction. Results : In both of ST 36 and ST 25, stimulation with 0.4 mm diameter needle showed significant rapid recovery followed by short period of muscle fatigue increase. Stimulation with 0.2 mm diameter significantly suppressed the increase of muscle fatigue. Conclusions : These data suggest that acupuncture effect is, at least in part, dependent on diameter of needle. Therefore, diameter of needle is also considered to achieve effective outcome of acupuncture.

An Experimental Study on the Behavior of Miscopiles installed in Weathered Weak Rock (풍화암 지반에 설치된 소구경말뚝의 거동에 관한 연구)

  • 박성재;정경환;이세훈
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 한국지반공학회 1999년도 가을 학술발표회 논문집
    • /
    • pp.389-396
    • /
    • 1999
  • In this study compressive and tensile load tests have been performed to investigate reinforcing effect and load transfer mechanism of small diameter piles installed in the foundation soil for the marine suspension bridge. Load tests were carried out on steel plate with diameters of 50cm, 100cm and 150cm varying loads starting from 39 tons up to 314 tons. Small diameter piles were proved to behavior like as friction piles and loads were not transmitted to the bottom of piles. From pull-out tests, the uplift capacity of small diameter piles was largely influenced by reinforcing materials compared to frictional resistance between piles and adjacent soils. The bearing capacity of small diameter piles appeared to be higher than the ultimate bearing capacity evaluated using static formulae. The load carrying capacity of small diameter piles was superior to the bored piles with a similar size. Thus, ultimate bearing capacity estimated from static formulae can provide conservative designs and thereby resulting in economic disadvantages. A further study to accumulate data regarding various soil conditions is recommended for an improved estimation of bearing capacity of piles with small diameter.

  • PDF

A Basic Study of Plasma Reactor of Dielectric Barrier Discharge for the Water Treatment (수처리용 유전체장벽 플라즈마 반응기에 대한 기초 연구)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • 제20권5호
    • /
    • pp.623-630
    • /
    • 2011
  • This study investigated the degradation of N, N-Dimethyl-4-nitrosoaniline (RNO, indicator of the generation of OH radical) by using dielectric barrier discharge (DBD) plasma. The DBD plasma reactor of this study consisted of a quartz dielectric tube, titanium discharge (inner) and ground (outer) electrode. The effect of shape (rod, spring and pipe) of ground electrode, diameter (9~30 mm) of ground electrode of spring shape and inside diameter (4~13 mm) of quartz tube, electrode diameter (1~4 mm), electrode materials (SUS, Ti, iron, Cu and W), height difference of discharge and ground electrode (1~15.5 cm) and gas flow rate (1~7 L/min) were evaluated. The experimental results showed that shape of ground electrode and materials of ground and discharge electrode were not influenced the RNO degradation. The thinner the diameter of discharge and ground electrode, the higher RNO degradation rate observed. The effect of height gap of discharge between ground electrode on RNO degradation was not high within the experimented value. Among the experimented parameters, inside diameter of quartz tube and gas flow rate were most important parameters which are influenced the decomposition of RNO. Optimum inside diameter of quartz tube and gas flow rate were 7 mm and 4 L/min, respectively.

Utility of Nuclear Morphometry in Effusion Cytology

  • Ambroise, Marie Moses;Jothilingam, Prabhavati;Ramdas, Anita
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권16호
    • /
    • pp.6919-6922
    • /
    • 2014
  • Background: The cytological analysis of serous effusions is a common investigation and yields important diagnostic information. However, the distinction of reactive mesothelial cells from malignant cells can sometimes be difficult for the cytopathologist. Hence cost-effective ancillary methods are essential to enhance the accuracy of cytological diagnosis. The aim of this study was to examine the utility of nuclear morphometry in differentiating reactive mesothelial cells from malignant cells in effusion smears. Materials and Methods: Sixty effusion smears consisting of 30 effusions cytologically classified as malignant (adenocarcinomas) and 30 benign effusions showing reactive mesothelial cells were included in the study. ImageJ was used to measure the nuclear area, perimeter, maximal feret diameter, minimal feret diameter and the circularity. A total of ten representative cells were studied in each case. Results: Significant differences were found between benign and malignant effusions for the nuclear area, perimeter, maximal feret diameter and minimal feret diameter. No significant difference was found for circularity, a shape descriptor. Receiver operating characteristic (ROC) curve analysis revealed that nuclear area, perimeter, maximal feret diameter, and minimal feret diameter are helpful in discriminating benign and malignant effusions. Conclusions: Computerised nuclear morphometry is a helpful ancillary technique to distinguish benign and malignant effusions. ImageJ is an excellent cost effective tool with potential diagnostic utility in effusion cytology.

Length Effects of Hetero-Core Optical Biosensor based on Evanescent Field Absorption

  • Shim, Joon-Hwon;Chan, Joo-Kwong;Sohn, Kyung-Rak
    • Journal of Navigation and Port Research
    • /
    • 제32권9호
    • /
    • pp.723-727
    • /
    • 2008
  • Sensing performances of evanescent field absorption (EFA) hetero-core fiber sensor has been presented based on EFA by changing the length and the core diameter of the single mode fiber. Experimental results have demonstrated a good feature in their relationship between the length and the core diameter of the single mode fiber. The sensor consists of 2 fiber optics which have the same cladding diameter of $125{\mu}m$ However one fiber optic used is single mode and has varying core diameter ranging from 3.3 to $5.6{\mu}m$. The other fiber is multimode type and has a thicker fixed core diameter of $62.5{\mu}m$. The 2 fiber optics are thermally spliced together. Experiments conducted to measure the resonance wavelength were carried out over a range of refractive index, to find the optimum sensing length Experiments show that core diameter of the single mode fiber and sensing length offects the linearity and sensitivity.