• 제목/요약/키워드: DIAMETER

검색결과 19,160건 처리시간 0.045초

2D 혈관조영술에서 직접 측정한 혈관 직경과 MR 영상에서 단면적 기반 환산 직경의 비교 분석 (Comparative Analysis between Directly Measured Diameter in 2D Angiography and Cross-Sectional Area-Converted Diameter in MR Image)

  • 이기백;김미현
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제46권5호
    • /
    • pp.427-433
    • /
    • 2023
  • This study aimed to quantitatively compare the diameters measured directly from the coronal plane or sagittal plane of 2D digital subtraction angiography (DSA) and the cross-sectional area-converted diameters calculated from contrast-enhanced MR (CE-MR) imaging. A retrospective analysis was conducted on 20 patients who underwent both 2D DSA and CE-MR imaging. Firstly, the venous diameters of the superior sagittal sinus (SSS) and transverse sinus (TS) were directly measured from 2D DSA. Subsequently, the axial planes for SSS diameter and the sagittal plane for TS in CE-MR imaging were utilized to calculate cross-sectional area-based converted diameters. The numerical values obtained from 2D DSA and CE-MR imaging were compared pairwise at each location. For SSS, the diameter measured by 2D DSA was 27% larger than the conversion-based diameter from CE-MR imaging (9.8±1.4 mm vs. 7.1±1.3 mm, P<0.05). Similarly, for the right TS, the difference was 16% (8.8±3.2 mm vs. 7.4±2.0 mm, P<0.05), and for the left TS, the difference was 22% (8.4±2.8 mm vs. 6.6±1.3 mm, P<0.05). In conclusion, the diameter measured directly in conventional 2D DSA may be larger than the diameter converted based on the cross-sectional area. Therefore, when selecting the size of the stent, it is crucial to make precise determinations while keeping this fact in mind.

Diameter 프로토콜에서의 실시간 Accounting 기법 (Real time accounting scheme of diameter protocol)

  • 박건영;김기천
    • 한국정보과학회:학술대회논문집
    • /
    • 한국정보과학회 2003년도 가을 학술발표논문집 Vol.30 No.2 (3)
    • /
    • pp.601-603
    • /
    • 2003
  • AAA 프로토콜중에 하나인 DIAMETER의 기능과 특성에 대해서 알아보고 유무선의 다양한 환경에서 신뢰할 수 있는 실시간 Accounting을 할 수 있도록 하기 위해 기존의 Accounting의 문제점을 보완한 Accounting 모델에 대해 알아 보도록 한다.

  • PDF

세관내 R-22와 R-410A의 응축 압력강하 (The Condensation Pressure Drop of R-22 and R-410A in Small Diameter Tube)

  • 손창효
    • 한국수소및신에너지학회논문집
    • /
    • 제19권2호
    • /
    • pp.156-162
    • /
    • 2008
  • The condensation pressure drop for R-22 and R-410A flowing in a small diameter tube was investigated. The test section is a counterflow heat exchanger with refrigerant flowing in the inner tube and coolant flowing in the annulus. The test section consists of 1220 mm length with horizontal copper tube of 3.38 mm outer diameter and 1.77 mm inner diameter. The refrigerant mass fluxes ranged from 450 to $1050\;kg/m^2{\cdot}s$ and the average inlet and outlet qualities were 0.05 and 0.95, respectively. The main experimental results were summarized as follows : In the case of two-phase flow, the pressure drop increases with increasing mass flux and decreasing quality. The pressure drop of R-22 is slightly higher than that of R-410A for the same mass flux. Most of correlations proposed in the large diameter tube showed enormous deviations with experimental data.

타원형휜-원형관 열교환기의 강제대류 열전달 특성 (CONVECTIVE HEAT TRANSFER CHARACTERISTICS OF OVAL FIN-CIRCULAR TUBE HEAT EXCHANGER)

  • 강희찬;이종휘
    • 한국전산유체공학회지
    • /
    • 제15권2호
    • /
    • pp.1-6
    • /
    • 2010
  • The purpose of the present study is to investigate the flow resistance and the heat transfer characteristics of oval fin-tube heat exchanger. Six kinds of oval fin having the same fin area and different diameter ratio tested numerically. Test data for the heat transfer, pressure drop and fin temperature were shown and discussed. The pressure drop and heat transfer increased for increasing the oval fin diameter ratio(diameter of span-wise direction to diameter of longitudinal diameter) up to 50% and 45% respectively.

타원형휜-원형관 열교환기의 강제대류 열전달 특성 (CONVECTIVE HEAT TRANSFER CHARACTERISTICS OF OVAL FIN-CIRCULAR TUBE HEAT EXCHANGER)

  • 강희찬;이종휘
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2009년 춘계학술대회논문집
    • /
    • pp.341-346
    • /
    • 2009
  • The purpose of the present study is to investigate the flow resistance and the heat transfer characteristics of oval fin-tube heat exchanger. Six kinds of oval fin having the same fin area and the different diameter ratio tested numerically. Test data for the heat transfer, pressure drop and fin temperature were shown and discussed. The pressure drop and heat transfer increased for increasing the oval fin diameter ratio(diameter of span-wise direction to diameter of longitudinal diameter) up to 50% and 45% respectively.

  • PDF

단일벽 탄소 나노튜브의 길이와 지름에 따른 분류 (Separation of Single-Walled Carbon Nanotubes by Length and Diameter)

  • 오영석;이덕진;장윤석;최재붕;김영진;백승현
    • 한국정밀공학회지
    • /
    • 제23권3호
    • /
    • pp.171-178
    • /
    • 2006
  • The sonication mettled is widely used with surfactants to suspend individual single-walled carbon nanotubes in solution, and it is well known that sonication-induced tube cutting occurs. Recently, it is found out that ultrasonicated nanotubes yield simultaneous separation by tube length and diameter. Nanotubes that have been cut shortest possess the greatest enrichments of large-diameter species. In this study, single-walled carbon nanotubes are cut using a ball milling method. Similar fracture behavior is observed fur the ball milled nanotubes: i.e., large diameter tubes are cut shorter. The ability to separate carbon nanotubes by diameter and length will contribute to tile development of nanotube-based applications.

정전용량센서를 이용한 W/O형 유화연료의 안정성 평가 (An Estimation on the Stability of W/O Type Emulsified Fuel Using by Capacitance Sensor)

  • 조성철;오양환;임석연
    • 한국응용과학기술학회지
    • /
    • 제28권1호
    • /
    • pp.95-101
    • /
    • 2011
  • We estimated on the stability of W/O type emulsified fuel using by capacitance sensor, so it concluded the following conclusions. For the first 24 hours, prepared emulsified fuel reveals phase separation ratio of 5%, maintains stable status which verifies the stability of emulsified fuel. Adding more water increases the phase separation ratio rapidly, and adding more surfactant displays stable emulsification. Adding water causes larger size of water droplet diameter, and adding surfactant mixture causes smaller size of water droplet diameter. In conclusion, the size of W/O type emulsified fuel water droplet diameter is directly related to the volume of surfactant, and density of water droplet diameter changes thedistribution according to water contents.

2중관형 2상 열사이폰의 한계열유속 특성에 관한 연구 (A Study on Critical Heat Elux Characteristics in a Two-Phase Concentric-Tube Thermosyphon)

  • 김욱
    • 대한기계학회논문집B
    • /
    • 제26권10호
    • /
    • pp.1419-1426
    • /
    • 2002
  • An experimental study was made to elucidate critical heat flux(CHF) characteristics in a two-phase concentric-tube thermosyphon. The experiment was performed by using saturated water, over the experimental range of configuration: inner diameter of heated outer tube D=12mm, outer diameter of unheated inner tube do=3 to 10mm and heated tube length L=100 to 1000mm. The experiment shows that the CHF is enhanced with increase in the inner tube diameter, and that the CHF decreases beyond a certain diameter of the inner tube. There is an optimum diameter for inner tube that maximizes the CHF, for each tube length and test liquid. The CHF maximum is about two to eight times as large as that without an inner tube. For a large inner tube, the CHF characteristics is similar to that for natural convective boiling in a vertical annular tube.

원전 구조물용 대구경 철근의 기계적 정착을 위한 정착판 설계 (Anchor plate design for mechanical anchorage of large diameter reinforcement in nuclear containment buildings)

  • 이성호;천성철;오보환;박형철;나환선;김상구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.136-139
    • /
    • 2003
  • The re-bar work in the construction of nuclear power plants is difficult, due to the large diameter and the congestion of reinforcements. The mechanical anchorage offers a potential solution for this problem. However, the requirements or the standards for the shape of anchor plate of mechanical anchor has not been clearly established up to now. In this paper, the required performance of the mechanical anchorage for large diameter reinforcements in nuclear power plants are proposed, and the anchor plates are designed through nonlinear finite element analysis. The diameters of anchor plate are determined to be $\sqrt{5}$ times of reinforcement diameter for longitudinal reinforcements and $\sqrt{10}$ for shear reinforcements. The thickness of anchor plates is optimized as 0.3-0.35 times of reinforcement diameter for longitudinal reinforcements and 0.5~0.56 times for shear reinforcements.

  • PDF