• Title/Summary/Keyword: DHB

Search Result 31, Processing Time 0.029 seconds

MALDI-TOF Analysis of Polyhexamethylene Guanidine (PHMG) Oligomers Used as a Commercial Antibacterial Humidifier Disinfectant

  • Hwang, Hyo Jin;Nam, Jungjoo;Yang, Sung Ik;Kwon, Jung-Hwan;Oh, Han Bin
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.6
    • /
    • pp.1708-1714
    • /
    • 2013
  • Polyhexamethylene guanidine (PHMG) polymers used as an active ingredient in an antibacterial humidifier disinfectant were reported to cause harm to the human health when inhaled, although physical contact with this material was known to present low toxicity to humans. It is therefore necessary to develop an optimal analysis method which enables detection and analysis of PHMG polymers. MALDI-TOF investigations of PHMG are performed with a variety of matrices, and it is found that CHCA and 2,5-DHB are excellent matrices which well reflects the polymer population even at high mass. For the provided PHMG sample, the number-average ($M_n$) and weight-average ($M_w$) molecular masses were determined to be 744.8 and 810.7, respectively, when the CHCA was used as a matrix. The rank of the matrices in terms of averaged molecular weight was CHCA ~2,5-DHB > 5-NSA > DHAP, THAP > ATT > IAA ~ super-DHB ~ HABA. In addition, PSD of the PHMG oligomer ions exhibited a few unique fragmenation characteristics. The formation of a- and c-type fragments was the major fragmentation pathway, and the 25-Da loss peaks generally accompanied a- and c-type fragments.

Detection of Long Alkyl Esters of Succinic and Maleic Acid Using TLC-MALDI-MS

  • Kim, Hin-Hee;Han, Sang-Pil;Kim, Jeong-Kwon;Kim, Yeong-Joon
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.3
    • /
    • pp.915-920
    • /
    • 2011
  • Four esters of succinic and maleic acid were synthesized, separated by thin-layer chromatography (TLC), and identified using matrix-assisted laser desorption/ionization-mass spectrometry (MALDI-MS). A comparison of matrix materials showed that 2,6-dihydroxybenzoic acid (2,6-DHB) yielded a greater ionization efficiency than 2,5-DHB prior to TLC separation. The location of each ester sample on the TLC plate was estimated by comparing the developed plate with a duplicate plate that had been visualized by immersion in a $KMnO_4$ solution. Generally, mass spectra obtained from the $KMnO_4$-visualized plate were relatively poor. Reproducible mass spectra with high peak abundance were difficult to obtain using the 2,6-DHB matrix from crude synthetic esters extracted from the TLC plates. Significant improvements in both reproducibility and sensitivity were realized by using pencil lead as the MALDI matrix. The current methodology will be beneficial to organic chemists since it can provide a guideline for simple and rapid characterization of small organic compounds.

A Double-Hybrid Spread-Spectrum Technique for EMI Mitigation in DC-DC Switching Regulators

  • Dousoky, Gamal M.;Shoyama, Masahito;Ninomiya, Tamotsu
    • Journal of Power Electronics
    • /
    • v.10 no.4
    • /
    • pp.342-350
    • /
    • 2010
  • Randomizing the switching frequency (RSF) to reduce the electromagnetic interference (EMI) of switching power converters is a well-known technique that has been previously discussed. The randomized pulse position (RPP) technique, in which the switching frequency is kept fixed while the pulse position (the delay from the starting of the switching cycle to the turn-on instant within the cycle) is randomized, has been previously addressed in the literature for the same purpose. This paper presents a double-hybrid technique (DHB) for EMI reduction in dc-dc switching regulators. The proposed technique employed both the RSF and the RPP techniques. To effectively spread the conducted-noise frequency spectrum and at the same time attain a satisfactory output voltage quality, two parameters (switching frequency and pulse position) were randomized, and a third parameter (the duty ratio) was controlled by a digital compensator. Implementation was achieved using field programmable gate array (FPGA) technology, which is increasingly being adopted in industrial electronic applications. To evaluate the contribution of the proposed DHB technique, investigations were carried out for each basic PWM, RPP, RSF, and DHB technique. Then a comparison was made of the performances achieved. The experimentally investigated features include the effect of each technique on the common-mode, differential-mode, and total conducted-noise characteristics, and their influence on the converter’s output ripple voltage.

Comparison of Matrices for Optimal Analysis of Synthetic Polymers Using MALDI-TOF Mass Spectrometry

  • Yoo, Hee-Jin;Kim, Duck-Hyun;Choi, Yoon-Ji;Choi, Jung Hoon;Park, Moonhee;Shin, DongJin;Oh, YoonSeok;Kim, YangSun;Cho, Kun
    • Mass Spectrometry Letters
    • /
    • v.11 no.4
    • /
    • pp.77-81
    • /
    • 2020
  • Characterization of the various chemical aspects of composite polymers is important for quality control of manufactured polymers. In this study, we compared three suitable matrices (α cyano-4-hydroxycinnamic acid [CHCA], 2,5 dihydroxy benzoic acid [2,5-DHB], and dithranol), to characterize various synthetic polymers by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. Although the spectra obtained with the CHCA and 2,5-DHB matrices were generally good, in certain samples ghost peaks disappeared only when dithranol was used as the matrix. Furthermore, we examined the use of sodium trifluoroacetate (NaTFA) as an additive to reduce interference by metals and copolymers in the spectra. In conclusion, appropriate selection of a matrix, according to the characteristics of the polymer, and the use of additives to improve sensitivity are important considerations for polymer analysis and development.

Tertiary Matrices for the Analysis of Polyethylene Glycols Using MALDI-TOF MS

  • Hong, Jangmi;Kim, Taehee;Kim, Jeongkwon
    • Mass Spectrometry Letters
    • /
    • v.5 no.2
    • /
    • pp.49-51
    • /
    • 2014
  • The effectiveness of tertiary matrices composed of the combination of three common matrices (dihydrobenzoic acid (DHB), ${\alpha}$-cyano-4-hydroxycinnamic acid (CHCA), and sinapinic acid (SA)) was compared with that of single or binary matrices in the analysis of polyethylene glycol (PEG) polymers ranging from 1400 to 10000 Da using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS). A tertiary matrix of 2,5-DHB+CHCA+SA was the most effective in terms of S/N ratios. CHCA and CHCA+SA produced the highest S/N ratios among the single matrices and the binary matrices, respectively. The improvement observed when using a tertiary matrix in analyses of PEG polymers by MALDI-TOF MS is believed to be due to the uniform morphology of the MALDI sample spots and synergistic effects arising from the mixture of the three matrix materials.

MALDI Mass Spectrometric Analysis of Nonderivatized Steroids Using Cyclodextrin-supported 2,5-Dihydroxybenzoic Acid as Matrix

  • Son, Jeongjin;Cha, Sangwon
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.5
    • /
    • pp.1409-1412
    • /
    • 2014
  • Sex hormones are important metabolites in vertebrates' development and reproduction. For rapid screening sex hormones, matrix-assisted laser desorption/ionization (MALDI) mass spectrometry (MS) is one of the promising analytical platforms, but MALDI MS faces many challenges in detecting steroids such as low ionization efficiency and matrix background interference. One potential strategy to overcome matrix interference in the low m/z region is using a cyclodextrin (CD)-supported matrix for steroid analysis since CD-supported matrixes are known to effectively suppress matrix-related ion signals. In this study, we aimed to find the optimal CD-supported matrix for the analysis of the nonderivatized sex steroids. Our results showed that the ${\alpha}CD$-supported 2,5-dihydroxybenzoic acid (DHB) matrix efficiently ionized all three major classes of sex hormones, estrogens, androgens, and progestagens, with low or no matrix background and also with high sensitivity. In addition, the ${\alpha}CD$-supported DHB matrix mainly generated molecular ions or protonated ions of sex hormones, and this enabled us to obtain information-rich tandem mass spectra which potentially lead to unambiguous identification of steroid species from complex metabolite mixtures.

The behavior characteristics according to the quality of the sinkers of the yellow croaker drift gill net in the field (발돌재질에 따른 참조기유자망의 수중거동특성)

  • Kang, Kyoung-Bum;Kim, Suk-Jong
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.46 no.1
    • /
    • pp.10-19
    • /
    • 2010
  • As a series of studies about improvement of yellow croaker drift gill net fishing gear and development of the labor saving fishing system, this study analyzed the behavior characteristics of fishing gear, which does use three types of different sinker materials in the field tests. The result of maritime performance test indicated that the fishing gear which used the lead reached the maximum depth and bio ceramics hauled to the surface of water the fastest. The correlation between the sinking time (St) and depth (Dsl, Dsc, Dsb) of maritime performance test can be shown such experimental equations as Dsl=2.70St - 0.75, Dsc = 2.38St - 1.15, Dsb = 1.77St - 4.00. The correlation between the hauling time (Ht) and depth (Dhl, Dhc, Dhb) of maritime performance test can be shown such experimental equations as and Dhl = 7.88Ht + 35.48, Dhc = 7.80Ht + 40.01, Dhb = 7.95Ht + 36.44.

Development of a Matrix-prespotted Plate for Enhancing the Reproducibility of Serum Glycan Analysis by MALDI-TOF-MS

  • Ha, Mi-Young;In, Young-Ha;Maeng, Hye-Sun;Zee, Ok-Pyo;Lee, Jong-Sik;Kim, Yang-Sun
    • Mass Spectrometry Letters
    • /
    • v.2 no.3
    • /
    • pp.61-64
    • /
    • 2011
  • Matrix Assisted Laser Desorption/Ionization-Time-of-Flight mass spectrometry (MALDI-TOF-MS) is the most widely used MS technique for glycan analysis. However, the poor point-to-point and sample-to-sample reproducibility becomes a limit in glycan biomarker research. A prespotted MALDI plate which overcomes the large crystal formation of 2,5-dihydroxybenzoic acid (DHB) has been developed and applied for glycan analysis. A homogeneous matrix coated surface without a crystal structure was formed on a hydrophilic/ hydrophobic patterned surface using a piezoelectric device. The reproducible MALDI-TOF-MS data have been presented using MALDI imaging of beer glycan as well as serum glycan eluted from 10% and 20% ACN elution fractions. The glycan profile from the serum glycan by MALDI-TOF-MS with a DHB prespotted plate was highly conserved for 10 different spectra and the coefficient of variations of significant ion peaks of MALDI data varies from 3.59 to 19.95.

Efficiency of Gas-Phase Ion Formation in Matrix-Assisted Laser Desorption Ionization with 2,5-Dihydroxybenzoic Acid as Matrix

  • Park, Kyung Man;Ahn, Sung Hee;Bae, Yong Jin;Kim, Myung Soo
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.3
    • /
    • pp.907-911
    • /
    • 2013
  • Numbers of matrix- and analyte-derived ions and their sum in matrix-assisted laser desorption ionization (MALDI) of a peptide were measured using 2,5-dihydroxybenzoic acid (DHB) as matrix. As for MALDI with ${\alpha}$-cyano-4-hydroxy cinnamic acid as matrix, the sum was independent of the peptide concentration in the solid sample, or was the same as that of pure DHB. This suggested that the matrix ion was the primary ion and that the peptide ion was generated by matrix-to-peptide proton transfer. Experimental ionization efficiencies of $10^{-5}-10^{-4}$ for peptides and $10^{-8}-10^{-7}$ for matrices are far smaller than $10^{-3}-10^{-1}$ for peptides and $10^{-5}-10^{-3}$ for matrices speculated by Hillenkamp and Karas. Number of gas-phase ions generated by MALDI was unaffected by laser wavelength or pulse energy. This suggests that the main role of photo-absorption in MALDI is not in generating ions via a multi-photon process but in ablating materials in a solid sample to the gas phase.

Determination Method for Topology Configuration of Hybrid Cascaded H-Bridge Rectifiers

  • Zhuang, Yuan;Wang, Cong;Wang, Chang;Cheng, Hong;Gong, Yingcai;Wang, Hao
    • Journal of Power Electronics
    • /
    • v.16 no.5
    • /
    • pp.1763-1772
    • /
    • 2016
  • To reduce system complexity and implementation costs, fully-controlled H-bridge (FHB) modules and diode H-bridge PFC (DHB) modules are cascaded to form a hybrid cascaded H-bridge rectifier (HCHR). In this paper, the advantages of such a HCHR over other cascaded rectifiers are analyzed depending on the numbers of FHB modules and DHB modules. Therefore, to assign proper numbers to these two kinds of modules for the HCHR, a configuration determination method is investigated under balanced and imbalanced loads. Three principles are also presented to guide the configuration determination for the HCHR. In addition, the constraints for selecting the step-up ratio and filter inductance are derived based on a phasor diagram analysis. The proposed configuration determination method is validated by simulations under three different conditions in the PSIM environment. Finally, experiments are carried out on a scaled-down prototype where the configuration can be easily adjusted. The feasibility of the proposed theory is then verified by experimental results.