• Title/Summary/Keyword: DETERIORATION TYPE

Search Result 510, Processing Time 0.021 seconds

Deterioration Status of Closed- Trail of National Parks on the Baekdudaegan Mountains, South Korea (백두대간권역 국립공원 비개방 탐방로의 훼손실태)

  • Cho, Woo
    • Korean Journal of Environment and Ecology
    • /
    • v.26 no.5
    • /
    • pp.827-834
    • /
    • 2012
  • The purpose of this study is to provide scientific data to support policy making on core area management in national parks, particularly to resolve conflict regarding trail closure, by analyzing the physical characteristics of trails in the Seoraksan and Songnisan National Park on the Baekdudaegan mountains. For the analysis, we surveyed 112 points selected from three sections and one section of closed trails in Seoraksan and Songnisan, respectively (17.1 km in total). The surveyed trails had, on average, trail width of 0.98m, baresoil width of 0.84 m, maximum erosion depth of 11.6cm, and trail slope of 14.2%. Of 53 out of 112 surveyed points (47.3%), we found exposed roots. Only 47 points (42.0%) did not show any type of physical deterioration. The magnitudes of deterioration in the surveyed closed-trail are relatively lower than those in open-trail in other national parks and are similar to those of ridge trails on the Baekdudaegan mountains.

Assessment of Impact Rating Class and Deterioration Type on the Trails in Mt. Namsan District, Gyeongju National Park (경주국립공원 남산 지구의 탐방로 훼손 유형 및 환경피해도 평가)

  • Heo, Sang-Hyun;You, Ju-Han
    • Journal of Environmental Science International
    • /
    • v.24 no.11
    • /
    • pp.1431-1442
    • /
    • 2015
  • This study was carried out to systematically maintain and manage the trails by assessing the physical characteristics, the types of deterioration and impact rating class of trails located in Mt. Nam District of the Gyeongju National Park. The major trails followed 6 routes including Sambulsa-Geumobong(A), Yongjangsaji-Geumobong(B), Yongjanggol-Yiyoungjae-Gowibong(C), Cheonusa-Gowibong(D), Sangseojang-Forest road(E) and Tongiljeon-Forest road(F). The routes length of A was 2.2 km, 2.7 km of B, 3.4 km of C, 1.3 km of D, 2.0 km of E and 1.0 km of F. In the physical characteristics, A was the widest and F was the narrowest in the width and bared width of trail. In depth of erosion, B was the deepest and E was the shallowest. D was the steepest and E was the gentlest in the slope. In the results of analysing the types of deterioration, A were 13 types, 11 types of B, C and D, 10 types of E and 6 types of F. The times of appearance of deterioration types in A were 86 times, 75 times of B, 105 times of C, 48 times of D, 47 times of E and 13 times of F. In case of the impact rating class, trail erosion was II degree, I degree of trail expansion, root exposure, trail divergence and rock exposure.

Deterioration Characteristics and an On-Line Diagnostic Equipment for Surge Protective Devices (서지 보호기의 열화 특성과 온라인 진단장치)

  • Park, Kyoung-Soo;Wang, Guoming;Hwang, Seong-Cheol;Kim, Sun-Jae;Kil, Gyung-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.10
    • /
    • pp.635-640
    • /
    • 2016
  • This paper dealt with the deterioration characteristics and an on-line diagnosis equipment for SPDs (surge protective devices). An accelerated aging test was carried out using a $8/20{\mu}s$ standard lightning impulse current to analyze the changes of electrical characteristics and to propose the diagnostic parameters and the criterion for deterioration of ZnO varistor which is the core component of SPDs. Based on the experimental results, an on-line diagnosis equipment for SPD was fabricated, which can measure the total leakage current, reference and clamping voltage. The leakage current measurement circuit was designed using a low-noise amplifier and a clamp type ZCT. A linear controller, the leakage current measurement part and a HVDC were used in the measurement of reference voltage. The measurement circuit of clamping voltage consisted of a surge generator and a coupling circuit. In a calibration process, measurement error of the prototype equipment was less than 3%.

Performance Characteristics with Various Fuel Composition and Temperature for an External Type Fuel Pump in LPLi System (LPLi 시스템에서 외장형 펌프의 연료조성 및 온도에 따른 성능특성 연구)

  • Nam, Deok-Woo;Yoon, Jun-Kyu;Lim, Jong-Han
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.5
    • /
    • pp.566-575
    • /
    • 2011
  • Since LPG (Liquefied petroleum gas) fuel supply system has an advantage of low emission characteristics, many studies have been conducted. In spite of the advantage of LPG supply system, a higher vapor pressure and lower viscosity than diesel or gasoline fuel may cause unstable running of fuel pump by the deterioration in lubrication performance and chemical reaction with rubber parts than that of diesel and gasoline fuel. Therefore its physical properties can cause the deterioration of durability. In this research, we developed an external type LPG pump which has the advantage of the price competitiveness and the convenient maintenance for LPLi system. The experiments were carried out in order to assess characteristics of the external type fuel pump at different fuel composition and temperature. As a result, there aren't any differences between internal and external type pump performance. It is observed that the same level of efficiency was maintained for both pumps as flow rate was increased with higher fuel temperature and more contents of propane in the fuel. And the pressure difference in LPLi system is maintained at constant with the various fuel compositions and temperatures due to their own characteristics of fuel supply system.

Evaluation of Diagnosis Properties of Capacitive Sensor about Deteriorated Pattern of Electrical Insulating Oil (전기 절연유의 열화 패턴에 따른 정전용량형 센서의 열화감지특성 평가)

  • Kim, Ju-Han;Kim, Jae-Hoon;Lee, Won-Yeong;Kim, Pil-Hwan;Han, Sang-Ok;Kim, Han-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1829-1831
    • /
    • 2004
  • This paper described the capacitive sensor for the diagnosis of deterioration of electrical insulating oils applying guard-ring type the 3-terminal electrodes. To measure stable capacitance of the sensor and to determine the design factors of the sensor, we utilized computational analysis, FEM software. This capacitive sensor discern the extent of deterioration measuring relative permittivity of electrical insulating oils. The result of measuring numerous sample, mineral oils, as serviced year, we confirmed an increase in relative permittivity of oils. Moreover, we confirmed the superior characteristics of the sensor as a species, aged pattern of oils and operating temperature.

  • PDF

Development of Deterioration Detecting Sensor in Oil for Diagnosis of Oil-Filled Transformers (유입 변압기 진단을 위한 유중 열화 측정 센서의 개발)

  • Min, Kyeoung-Rae;Yoon, Yong-Han;Kim, Young-Chun;Kim, Jae-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.128-130
    • /
    • 2000
  • This paper develops the deterioration detecting sensor in oil to monitor and diagnose oil-filled transformer more effectively. The on-line inspection of the oil-filled transformers used the temperature, the changes of the capacitance, the $tan{\delta}$ in oil. This sensor was designed based on the concentric cylindrical type so that it could be placed inside of the oil-filled transformer. And comparing to the existing system, it was proven to be appropriate. Establishment of the proposed sensor helps to build the confidence in monitoring of the oil-filled transformers.

  • PDF

A Study on the Chloride Attack Resistance of Marine Concrete by Accelerated Deterioration Test of Artificial Seawater (인공해수촉진열화시험에 의한 해양콘크리트의 내염특성에 관한 연구)

  • Lee, Jun;Seo, Jung-Pil;Cho, Sung-Hyun;Bae, Jun-Young;Park, Sang-Joon;Kim, Kyoung-Min
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.357-358
    • /
    • 2010
  • This study was performed an evaluation of chloride attack resistance properties of marine concrete by accelerated deterioration test of artificial seawater. As the results of study, when considering the compressive strength and chloride ion penetration of concrete, the proper type to improvement of chloride attack resistance is thought to marine cement.

  • PDF

Supravalvular Pulmonic Stenosis with Pulmonary Hypertension in a Bedlington Terrier Dog

  • Park, Kuk-Te;Hyun, Changbaig
    • Journal of Veterinary Clinics
    • /
    • v.34 no.4
    • /
    • pp.268-271
    • /
    • 2017
  • A 1.3 year-old Castrated male Bedlington terrier (10.0 kg of body weight) was presented with heart murmur and occasional coughing. Diagnostic imaging studies revealed supravalvular pulmonic stenosis (maximal velocity 2.91 m/s) from abnormal membranous structure (aperture) distal to the pulmonary valve in the main pulmonary artery. Further study also revealed pulmonic regurgitant (1.82 m/s of peak velocity, 13.2 mmHg of pressure gradient) jets started from the abnormal membranous structure. Since the dog had no obvious clinical signs related to heart failure, no interventional therapy including balloon dilation was considered in this case. Instead, medical treatment for preventing further deterioration of clinical signs related to PS was done with enalapril. This case report described a rare case of type III supravalvular PS in a dog, which has never been reported. Further deterioration of clinical signs has yet been recognized after medical treatment.

Analysis on the Diagnosis Characteristics of Electrical Insulating Oil for Power Transformer with 3-terminal Capacitive Sensor (3전극형 전기용량 센서를 이용한 변압기 절연유의 열화감지특성 평가)

  • Kim, Ju-Han;Seo, Pan-Seok;Kim, Pil-Hwan;Kim, Myung-Hwan;Park, Hung-Seok;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2004.11d
    • /
    • pp.89-92
    • /
    • 2004
  • This paper described the capacitive sensor for the diagnosis of deterioration of electrical insulating oils applying guard-ring type the 3-terminal electrodes. To measure stable capacitance of the sensor and to determine the design factors of the sensor, we utilized computational analysis, FEM software. This capacitive sensor discern the extent of deterioration measuring relative permittivity of electrical insulating oils. The result of measuring numerous sample, mineral oils, as serviced year, we confirmed an increase in relative permittivity of oils. Moreover, we confirmed the superior characteristics of the sensor as a species, aged pattern of oils and operating temperature.

  • PDF

The Impact of Total Radiation Flux on Organic Materials under LED Lighting

  • Kim, Ji Won;Lee, Jin Hwan;Kim, Kyu Lin;Ryu, Jae Hyung;Kang, Dai Ill
    • Journal of Conservation Science
    • /
    • v.36 no.4
    • /
    • pp.236-243
    • /
    • 2020
  • In this study, an accelerated aging experiment for fabric and paper was conducted using two light emitting diode(LED) sources with different wavelength characteristics, and the discoloration under each lighting type was examined. Hanji(Korean traditional paper) and related textiles showed more discoloration under blue LEDs, while the blue wool standard showed more discoloration under white LEDs. This, indicated that the deterioration varied depending on the sample color. The the effect of the light source on artifact deterioration was primarily related to the total radiation flux(expressed in mill watts), rather than the total luminous flux(expressed in lumens). In addition, the discoloration of the investigated artifacts was dependent on the color rendering of the lighting.