• Title/Summary/Keyword: DETERIORATION TYPE

Search Result 512, Processing Time 0.024 seconds

Effect of Gypsum Mixture on Activation of Coal Gasification Slag (석고 혼입이 석탄가스화 슬래그의 활성화에 미치는 영향)

  • Cho, Hyeon-Seo;Kim, Min-Hyouck;Lee, Gun-Cheol;Cho, Do-Young
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.05a
    • /
    • pp.17-18
    • /
    • 2019
  • In this study, the initial strength reduction of coal gasification slag fine powders was confirmed through previous studies when used in cement formulations. It is also confirmed that the blast furnace slag is mixed with cementitious coal blast furnace slag, which is similar to coal gasification slag, to incorporate gypsum in order to prevent initial strength deterioration. In order to analyze the reactivity of coal gasification slag by desulfurization gypsum, the formation of hydrates and their reactivity at early ages were confirmed by electron microscope. In order to confirm the reactivity, the gypsum samples were prepared with unincorporated type and 2% mixed type. Experimental results showed that 2% of the desulfurized gypsum specimens reacted more actively than the uninjured ones.

  • PDF

Connection Method of Composite Precast Concrete Columns Using Thread Rebar (나사형 철근을 사용한 합성 PC기둥의 접합방법)

  • Kim, Tae-Koo;Lee, Sung-Ho;Kim, Sun-Kuk
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.14-15
    • /
    • 2013
  • Green Frame is precast concrete column-beam structure. There are three types on column connection. The coupler type which is one of the three, need to be improved because of unstability caused by pre-installation of column before casting the slab, and quality deterioration caused by lack of workspace. Therefore, in this study, new coupler connection type with thread rebar is suggested. The result of this study shall be used for the efficiency analysis of the new coupler connection.

  • PDF

Fault Analysis of IPM type BLDC Motor Using Nonlinear Modeling of Stator Inter Turn Faults (고정자 절연파괴 비선형 모델링을 이용한 매입형 영구자석 전동기의 고장분석)

  • Kim, Kyung-Tae;Hur, Jin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.3
    • /
    • pp.531-537
    • /
    • 2011
  • This paper proposes a finite element method (FEM)-based model of an interior permanent magnet (IPM) type BLDC motor having stator inter-turn faults. For more realistic simulation studies, the magnetic non-linearity is also considered in proposed model. And the simulation data are verified through experiment. By integrating the developed model with a current-controlled voltage source inverter (CCVSI) model, the characteristics of an inter-turn fault operated by six-switched inverter are investigated considering the speed control. And the circulating current, which is induced by magnetic linkage flux originated from PM, was analyzed from the view point of distortion of air-gap magnetic flux distribution caused deterioration of their torque.

A Review of the Deterioration and Damage of the Top Flange of the Highway PSC Box Girder Bridge based on the Condition Assessment Results (상태평가 결과 기반 고속도로 PSC Box 거더교 상부플랜지 열화·손상 실태 고찰)

  • Ku, Young-Ho;Han, Sang-Mook
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.6
    • /
    • pp.23-32
    • /
    • 2022
  • Although PSCB girder bridges account for 4% of the bridges in use on highways, they do not account for much, but 98% of PSCB girder bridges are 1st type and 2nd type of bridge. Also, the total length of the PSCB girder bridge is 16% (192km) of the total length of the highway bridge. Thus, the PSCB girder bridge can be one of the bridge types where maintenance is important. In order to analyze the damage types of PSCB girder bridges, a detailed analysis was conducted by selecting 62 places (477 spans) precision safety diagnosis reports considering ratio of the construction method and snow removal environment exposure class. Analysis of report and a field investigation was conducted, and as a result, most of the causes of deterioration damage were caused by rainwater (salt water) flowing into the bridge pavement soaking in between the top flange and the interface. After concrete slab deteriorate occurred then bridge pavement cracking and breaking increased and exfoliation of concrete occurred by corrosion and expansion of the reinforcing bars occurred. In addition, the cause of cracks in the longitudinal direction on the bottom of the top flange is considered to be cracks caused by restrained drying shrinkage. In conclusion, for reasonable maintenance considering the characteristics of PSCB girder bridges, it should be suggested in the design aspect that restrained drying shrinkage crack on top flange. Also, it is believed that differentiated maintenance method should be proposed according to snow removal environment exposure class.

Characterization of Surface Deterioration for Stone Property around the Hyeonleung (Royal Tomb of Joseon Dynasty) in Guri, Korea (구리 현릉 능상석물의 표면 손상특성 평가)

  • Oh, Jeong Hyun;Kim, Sa Dug;Lee, Chan Hee;Lee, Tae Jong
    • Journal of Conservation Science
    • /
    • v.32 no.3
    • /
    • pp.353-364
    • /
    • 2016
  • The materials of sculptured stone property around the Hyeonleung Royal Tomb in Guri consist mainly of high weathered of granitic rocks with magnetite-series. Deterioration characteristics occurred highly with microorganism, soil inflow and black contaminants at the burial mound zone. As a result of deterioration evaluation, stone surface around the burial mound zone show serious comprehensive damage of soil inflow (50.5%) and lichen coverage (47.6%) which are the major damaging factors, and there are about 8.6% of biological growth noticeably in the north side. Surface contaminants and the discoloration had the complex causes. Gypsum occurred between joints of stones and the major contaminant type, darkening which was analyzed organic bodies caused discoloration. From result of ultrasonic velocity measurements, there are mean value of 2,195 m/s with highly weathered (HW) grade. Most of the stone properties showed 4 to 5 weathered grade. Therefore, it turned out that sculpture stone properties require conservation treatments. To remove soil accelerating damage factors and lichen occupying high percents, the cleaning process is necessary and consolidation, rejoining and filling are needed as well. Also, consideration on removing conservation materials containing Ca and e fflorescence is required and retreatments need to be considered.

Damage Characteristics of Metal Materials According to the SO2 Concentration (이산화황 농도에 따른 금속시편의 손상 특성)

  • Kim, Myoung Nam;Lim, Bo A;Shin, Eun Jeong;Lee, Sun Myung
    • Korean Journal of Heritage: History & Science
    • /
    • v.46 no.1
    • /
    • pp.176-187
    • /
    • 2013
  • A study has been carried out on metal materials in order to identify the quantitative relation between the concentration and damage characteristics after evaluation of the damage characteristics according to the $SO_2$ concentration. The prepared metal samples, which were categorized according to the material (silver, copper, iron, lead, brass) were exposed to 0.01, 0.12, 1, 10, 100, 1,000, and 5,000ppm of $SO_2$ for 24 hours and the optical, physical, chemical deterioration rates both before and after testing were evaluated. The results showed optical deterioration, a loss of gloss on silver specimen with $SO_2$ 100ppm, an increase of color difference on brass, iron, copper and lead specimens with $SO_2$ 5,000ppm, as well as physical changes such as an increase of thickness and corrosion rate on iron sample with $SO_2$ 5,000ppm. In the case of chemical changes such as an increase sulfate ion ($SO{_4}^{2-}$) concentration and decrease of pH on iron and brass specimens were identified. These results suggest that $SO_2$ 100ppm caused clear optical deterioration on some metals such as silver and physicochemical and optical deterioration were identified at $SO_2$ 5,000ppm regardless of metal type. Also, It was concluded that iron and brass are the most susceptible of the metal specimens to $SO_2$.

Analyzing Characteristic of Deterioration Status for Stone Properties in the Tae-Jo Geonwolleung of the Royal Tombs of the Joseon Dynasty (조선왕릉 태조 건원릉 내 석물의 훼손 특성 분석)

  • Lee, Mi Hye;Lee, Myeong Seong;Chun, Yu Gun;Lee, Tae Jong
    • Korean Journal of Heritage: History & Science
    • /
    • v.48 no.4
    • /
    • pp.62-73
    • /
    • 2015
  • The Tae-Jo Geonwolleung is the tomb of the first king Tae-Jo of the Joseon Dynasty in the complex of the Royal Tombs of the Joseon Dynasty which is listed in World Heritage, and it contains various types of stone properties. The material of the stone properties consist of a single type of medium-grained biotite granite, however, each properties have different intensity and types in deterioration phenomena according to their locations and purposes. The major deterioration types of the stones are analyzed as physical decomposition and biodeterioration. The exfoliation, breaking-out and granular decomposition are widespread types of the deterioration throughout the entire burial mound stone properties and surrounding stone properties. On the other hands, the colonization of mosses and plants, and contamination by foreign materials are found more frequent in the burial mound stone properties as these stones are in contact with the soil of the tomb mound and moisture in the soil helped biodeterioration. It is suggested that anti-biology treatment and physical reinforcement are applied to the deteriorated stones to prevent further damage on the stone components of the tomb.

A Development of Small-diameter Composite Helical Spring for Reinforcement of Optical Fiber Jumper Cord (OJC) (광점퍼코드 (OJC) 보호용 미소 직경 복합재료 스프링 개발)

  • 윤영기;박성도;이연수;윤희석;이우일
    • Composites Research
    • /
    • v.15 no.4
    • /
    • pp.17-22
    • /
    • 2002
  • Small diameter composite helical springs (CS) are developed using a hot plated mold for reinforcement of common optical fiber jumper cord (OJC). The outer diameters of the springs are about 2 ~ 3mm. These springs are inserted into the OJC to protect the damage of an optical fiber from the sudden lateral load. Two types of CS, Yarn type (Y-type) and Band type (B-type), are manufactured to compare the effectiveness for the damage protection. The experimental works were conducted to check the effect of the CS covered around OJC on the mechanical and optical properties. Experimental observations show a considerable effect on the flexural resistance, hence slowing down the deterioration of the optical power by the internal damage of the fiber. Obtained main results are as follows: (1) Y-type CS has better protection abilities to lateral loading than B-types. (2) Compared with bare OJC, CS-OJC has less power loss under the loading. (3) OJC covered with the composite coil spring has a possibility for a practical usage with full fruits.

Implementation Strategy Based on the Classification of Depreciation Models (감가상각모형의 유형화에 기초한 적용방안)

  • Choi, Sungwoon
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.2
    • /
    • pp.217-230
    • /
    • 2014
  • The purpose of this study is to develop the Generalized Depreciation Function (GDF) and Winfrey Depreciation Function (WDF) by reviewing methods for the depreciation accountings. The Depreciation Accounting Models (DAM), including straight-line model, declining-balance model, sum-of-the-year-digit model and sinking fund model presented in this paper, are reclassified into the charging pattern of increasing type, decreasing type and constant type. This paper also discusses the development of the GDFs based on convex type, concave type and constant type according to the demand pattern of product, frequency of plant usage, deterioration of time, relative inadequacy, Capital Expenditure (CAPEX) and Operating Expenditure (OPEX) of the Total Productive Maintenance (TPM). The WDFs presented in this paper depict a sudden degradation of plant performance by measuring the change of TPM activity at the midpoint of useful life of asset. The WDFs are classified into left-modal type, symmetrical type and right-modal type by varying the value of skewness and kurtosis. Moreover, three increasing patterns, such as convex, concave and linear types, are used in this paper to present the distinct identification of WFDs by using Instantaneous Depreciation Rate (IDR) in terms of Performance Depreciation Function (PDF) and Depreciation Density Function (DDF). In order to have better understanding of depreciation models, the numerical examples are used for evaluating the Net Operating Less Adjusted Tax (NOPLAT) and Economic Value Added (EVA). It is concluded that the depreciation models showing a large dispersion of EVA require the adjustment of NOPLAT and Invested Capital (IC) based on the objective cash basis and net operating activity for reducing the variation of EVA.

Surgical Outcome of Adult Idiopathic Chiari Malformation Type 1

  • Yuh, Woon Tak;Kim, Chi Heon;Chung, Chun Kee;Kim, Hyun-Jib;Jahng, Tae-Ahn;Park, Sung Bae
    • Journal of Korean Neurosurgical Society
    • /
    • v.59 no.5
    • /
    • pp.512-517
    • /
    • 2016
  • Objective : The pathophysiology of idiopathic Chiari malformation (CM) type 1 is disturbance of free cerebrospinal fluid (CSF) flow and restoration of normal CSF flow is the mainstay of treatment. Additional migration of the medulla oblongata in pediatric patients is referred to as CM type 1.5, but its significance in adult patients is unknown. This study is to compare surgical outcomes of adult idiopathic CM type 1.5 with that of type 1. Methods : Thirty-eight consecutive adult patients (M : F=11 : 27; median, 33.5; range, 18-63) with syringomyelia due to idiopathic CM type 1 were reviewed. Migration of the medulla oblongata was noted in 13 patients. The modified McCormick scale (MMS) was used to evaluate functional status before and one year after surgery. All patients underwent foramen magnum decompression and duroplasty. Factors related to radiological success (${\geq}50%$ decrease in the diameter of the syrinx) were investigated. The follow-up period was $72.7{\pm}55.6$ months. Results : Preoperative functional status were MMS I in 11 patients and MMS II in 14 of CM type 1 and MMS I in 8 and II in 5 of CM type 1.5. Of patients with MMS II, 5/14 patients in group A and 3/5 patients in group B showed improvement and there was no case of deterioration. Radiological success was achieved in 32 (84%) patients and restoration of the cisterna magna (p=0.01; OR, 46.5) was the only significant factor. Conclusion : Migration of the medulla oblongata did not make a difference in the surgical outcome when the cisterna magna was restored.