• 제목/요약/키워드: DECAY CONSTANT

검색결과 208건 처리시간 0.024초

Dry Room내의 온.습도 분포 해석 (Analysis of Temperature and Humidity Distribution in a Dry Room)

  • 이관수;임광옥;안강호;정영식
    • 설비공학논문집
    • /
    • 제13권6호
    • /
    • pp.524-531
    • /
    • 2001
  • The temperature and humidity distribution in a dry room are studied numerically by using standard$\kappa-\varepsilon$ turbulence model. In order to evaluate effective heat and moisture ventilation characteristics inside the room, the heat removal capacity and moisture exhaust efficiency are introduced. An effective ventilation control is analyzed by evaluating quantitatively temperature and humidity distributions. It was found that the mean absolute humidity inside the room was almost constant with approximately 0.1905g/kg air regardless of the models and the heat generation rates. This was believed that the moisture generation by workers was relatively small. 40% improvement of the critical decay time was achieved, through the modifications of design variables.

  • PDF

축대칭 엔진 실린더내의 유동장에 관한 수치적 연구 (A Numerical Study on In-cylinder Flow Fields of an Axisymmetric Engine)

  • 최재성
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제23권5호
    • /
    • pp.662-670
    • /
    • 1999
  • A numerical prediction was performed to clarify the air motion in the cylinder of an axisymmet-ric four-stroke reciprocating engine at its intake and compression stage. A scheme of finite volume method is used for the calculation. Modified $k-{\varepsilon}$ turbulence model is adopted and wall function is applied to the grids near the wall. The predicted mean velocity and rms velocity profiles showed a reasonable agreement with an available experimental data at its intake and compression stage. The predicted in-cylinder flow fields show that a strong turbulent twin vortex structure is pro-duced during induction but it commences to decay rapidly around inlet valve closure. The mean velocity continues to fall to a low level during compression but the turbulence intensity attains an approximate constant level.

  • PDF

동기형 릴럭턴스 전동기의 파라메터 측정 (Parameter Measurement of Synchronous Reluctance Motor)

  • 윤준보;김솔;신정민;이갑재;이주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.930-932
    • /
    • 2003
  • As Synchronous Reluctance Motor gives reluctance torque, An inductance is an important parameter that is proportional to torque. To achieve the high performance in sensorless control, it is necessary to consider exact inductance values because the inductance is not a constant parameter anymore. Therefore, this paper shows the inductance measurement using DC current decay test, AC standstill test, and AC standstill test considering Cross Magnetization. This inductance has also been compared with the result that is analyzed by FEM.

  • PDF

LC 공진을 이용한 동기형 릴럭턴스 전동기의 파라미터 측정 (Parameter Measurement of Synchronous Reluctance Motor Using LC Resonance)

  • 김승주;안준선;김기찬;김솔;이주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1282-1284
    • /
    • 2005
  • As Synchronous Reluctance Motor gives reluctance torque, An inductance is an important parameter that is proportional to torque. To achieve the high performance in sensorless control, it is necessary to consider exact inductance values because the inductance is not a constant parameter anymore. Therefore, this paper shows the inductance measurement using DC current decay test and Generator-Resonance test.

  • PDF

Transient Absorption Spectra of Phenothiazine Derivative in the Vesicle System Containing Ru$^{2+}$ Complex as a Sensitizer

  • Park, Yong-Tae;Kim, Young-Doo;Burkhart, Richard D.;Caldwell, Norris J.
    • Bulletin of the Korean Chemical Society
    • /
    • 제9권2호
    • /
    • pp.84-87
    • /
    • 1988
  • The Photophysical and photochemical properties of Ruthenium bipyridine with two long hydrocarbon chains, $[Ru(bipy)_2(dhbipy)]^{2+}$ and transient phenothiazine derivative cation radical $(PTD^+)$ in the cationic vesicle were studied. Transient absorption spectra of cation radical of phenothiazine derivative in the vesicle system containing the $Ru^{2+}$ complex, $[Ru(bipy)_2(dhbipy)]^{2+}$, (1) as sensitizer and phenothiazine derivative as electron donor was observed by XeCl excimer laser photolysis system. Thus the excited ruthenium complex would be quenched by phenothiazine derivative(PTD) reductively in the vesicle system. The quenching rate constant($K_Q$) of $Ru^{2+}$ with two long hydrocarbon chains in the vesicle by PTD was $9.6{\times}10^8M^{-1}S^{-1}$. The absorption decay kinetics showed that lifetime of phenothiazine derivative cation radical is a value in the 4-8m sec range.

Interaction between Norfolxacin and Single Stranded DNA

  • 여정아;조태섭;Kim, Seog K.;문형랑;준길자;남원우
    • Bulletin of the Korean Chemical Society
    • /
    • 제19권4호
    • /
    • pp.449-457
    • /
    • 1998
  • We compared various spectroscopic properties of a norfloxacin-single stranded DNA complex with those of norfloxacin-double stranded DNA complex. Norfloxacin binds to both double-and single stranded DNA, and we observed the following spectroscopic changes for both complexes: hypochromism in the norfloxacin absorption region in the absorption spectrum, the characteristic induced CD spectrum consisting of a weak positive band at 323 nm and a strong positive band at 280-300 nm followed by a negative band in the 260 nm region, a strong decrease in the fluorescence intensity and a red-shift in the fluorescence emission spectrum, and shorter fluorescence decay times. These results indicate that the environments of the bound norfloxacin in both DNAs are similar, although the equilibrium constant of the norfloxacin-single stranded DNA was twice as high as the norfloxacin-double stranded DNA complex. Both complexes were thermodynamically favored with similar negative Δ$G^o$. Negative Δ$H^o$ terms contribute to these spontaneous reactions; Δ$S^o$ term was unfavorable.

Effectiveness of Ventilation Control in a Dry Room with a Heat and Moisture Source

  • Lee, Kwan-Soo;Lim, Kwang-Ok;Ahn, Kang-Ho;Jung, Young-Sick
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제9권4호
    • /
    • pp.1-9
    • /
    • 2001
  • The temperature and moisture distributions in a dry room with a heat and moisture source -i.e., workers- are studied numerically by using a standard $k-\varepsilon$ turbulence model. In order to evaluate the effectiveness of heat and moisture ventilation inside the room, the heat removal capacity and the moisture exhaust efficiency are introduced. The effectiveness of ventilation control is analyzed by evaluating the temperature and humidity distributions in the room quantitatively. It is found that the mean absolute humidity inside the room is almost constant regardless of the models and the heat generation rates in this study range. This results from the fact that the moisture generation by the workers was relatively small. Through the modification of the design, 40% improvement in critical decay time was achieved.

  • PDF

Optimum Gain Distribution of the Ampilfiers in High Power YLF($Nd^{3+}$)-Phosphate Glass($Nd^{3+}$) Laser System

  • CHi, Kyeong-Koo
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 1989년도 제4회 파동 및 레이저 학술발표회 4th Conference on Waves and lasers 논문집 - 한국광학회
    • /
    • pp.20-25
    • /
    • 1989
  • The nonlinear, time dependent photon transport equations of Frantz and Nodvik, which describe the amplification of an optical pulse in an active medium, are modified to a simpler equation which describes only the amplification of energy. with this equation, the output energy of the high power YLF(Nd3+)-Phosphate Glass(Nd3+) Laser System is calculated. When the stored energy density Est is 0.10J/㎤, 0.16J/㎤, 0.228J/㎤, and 0.50J/㎤, and with the assumption of uniform population inversion density, the final output energy of this laser system is 5.38J, 176J, 317J, and 283J, respectively. The gain saturation causes distortion of the output beam. This phenomenon is described in detail at the first three rod amplifier systems in the case of E=0.228J/㎤. The peak current and decay time constant of the flashlamps, which are used to obtain population inversion in the active medium, are investigated. The flashlamp driving circuit which has optimum operational performance should have {{{{ SQRT { LC} }} time about 100$\mu$sec.

  • PDF

Diagnostic methods applied to Esfahan light water subcritical reactor (ELWSCR)

  • Arkani, Mohammad
    • Nuclear Engineering and Technology
    • /
    • 제53권7호
    • /
    • pp.2133-2150
    • /
    • 2021
  • In this work, Esfahan light water subcritical reactor (ELWSCR) is analysed using experimental and theoretical diagnostic methods. Important neutronic parameters of the system such as prompt neutron lifetime, delayed neutron fraction, prompt neutron decay constant, negative reactivity of the core, fuel and moderator temperature coefficient of reactivity, and overall and local void coefficient of reactivity are estimated. Also, neutron flux distribution, reflector saving, water level effect, and lattice pitch of the core including operating point of the facility are studied in details. Theoretical results are calculated by MCNPX and measurements are performed utilizing zero power reactor noise method. Detailed descriptions of the results are explained in the text.

On the use of spectral algorithms for the prediction of short-lived volatile fission product release: Methodology for bounding numerical error

  • Zullo, G.;Pizzocri, D.;Luzzi, L.
    • Nuclear Engineering and Technology
    • /
    • 제54권4호
    • /
    • pp.1195-1205
    • /
    • 2022
  • Recent developments on spectral diffusion algorithms, i.e., algorithms which exploit the projection of the solution on the eigenfunctions of the Laplacian operator, demonstrated their effective applicability in fast transient conditions. Nevertheless, the numerical error introduced by these algorithms, together with the uncertainties associated with model parameters, may impact the reliability of the predictions on short-lived volatile fission product release from nuclear fuel. In this work, we provide an upper bound on the numerical error introduced by the presented spectral diffusion algorithm, in both constant and time-varying conditions, depending on the number of modes and on the time discretization. The definition of this upper bound allows introducing a methodology to a priori bound the numerical error on short-lived volatile fission product retention.