• Title/Summary/Keyword: DE(T) Specimen

Search Result 8, Processing Time 0.022 seconds

Plastic η Eactors for J-Integral Testing of Double-Edge Cracked Tension(DE(T)) Plates (양측균열인장(DE(T)) 평판의 J-적분 시험을 위한 소성 η계수)

  • Son, Beom-Goo;Shim, Do-Jun;Kim, Yun-Jae;Kim, Young-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.3
    • /
    • pp.259-266
    • /
    • 2004
  • Detailed two-dimensional and three-dimensional finite element (FE) analyses of double-edge cracked tension (DE(T)) specimens are carried out to investigate the effect of the relative crack length and the thickness on experimental J testing schemes. Finite element analyses involve systematic variations of relevant parameters, such as the relative crack depth and plate width-to-thickness ratio. Furthermore, the strain hardening index of material is systematically varied, including perfectly plastic (non-hardening) cases. Based on FE results, a robust experimental J estimation scheme is proposed.

Thorea indica sp. nov. (Thoreales, Rhodophyta) from Uttar Pradesh, India

  • Necchi, Orlando Jr;Paiano, Monica O.;West, John A.;Ganesan, E. K.;Goer, Susan Loiseaux-de
    • ALGAE
    • /
    • v.30 no.4
    • /
    • pp.265-274
    • /
    • 2015
  • Thorea indica sp. nov. is described from the Sai River, Uttar Pradesh, India (26°39′00.7″ N, 80°47′38.3″ E). Its classification is based on molecular sequences of the plastid-encoded RuBisCO large-subunit gene, rbcL and the barcode region of the mitochondrial encoded cytochrome c oxidase subunit 1, cox1, and morphological data. The sequence analyses confirm a new species of Thorea. The cox1 barcode sequence had 90.4-90.8% identity with Thorea sp. from Australia and Thorea hispida from Hawaii and China. Based on rbcL sequences the Indian specimen was positioned in a major clade with high support (>95 bootstrap and 0.95 posterior probability) containing two other species: T. okadae from Japan and T. hispida from the continental USA, Hawaii, the UK, and China. The divergences among these sequences were T. indica vs. T. okadae (2.8%) and T. indica vs. T. hispida (2.9-3.4%). The comparison of morphological characters of Thorea from India was not conclusive due to the inadequate descriptions in previous reports: most specimens reported as T. hispida fit within the circumscription of T. indica as described here. The previous report of T. siamensis from the Sai River is incorrect and the specimens fit within our description of T. indica. Thorea indica and T. okadae can be distinguished by minor morphometric characters and sexuality (dioecious vs. monoecious).

A Study on the Correlation Between Nugget Diameter and Contact Diameter of Sheets by Electrode Force (點熔接 의 너깃지름 과 板間接觸지름 의 關聯性)

  • 송삼홍;김부동
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.7 no.3
    • /
    • pp.313-318
    • /
    • 1983
  • It is required in designing a spot welding to get in advance an estimated figure of nugget diameter. A method of estimating nugget diameter of low carbon steel sheets is suggested in tesms of utilizing elastic calculation in theory and of making a sectional observation of specimen of spot welding in experiment. The resultant findings are summarized as follows: 1) A contact diameter of sheet, 2.gamma.$_{o}$=d sub e/+(1.1)t, wheer de is the electrode tip diameter and t is the thickness of sheets. 2) The practical measurement of the nugget diameter reveals that $d_{n}$=(1.05) $d_{e}$+(0.9)t, and $d_{b}$ is less by 0.8-4.3% than 2.gamma.$_{o}$. 3) The more $d_{n}$ is as compared with t, the less the difference between a theoretical value and an experimental value is. 4) In the spot welding of thin steel sheets less than 3mm in thickness that are commonly used in sheet metal works, the contact diameter equals the nugget diameter. In this case, either the theoretical or experimental approach can be used for estimating the nugget diameter.meter.ter.r.

A study on the bonding strength of co-cured T800/epoxy composite-aluminum single lap joint according to the forming and additional pressures (동시 경화법으로 제조된 T800/에폭시 복합재료-알루미늄 단면겹치기조인트의 성형압력 및 부가압력에 따른 접착강도에 관한 연구)

  • Son, Dae-Sung;Bae, Ji-Hun;Chang, Seung-Hwan
    • Composites Research
    • /
    • v.24 no.5
    • /
    • pp.23-28
    • /
    • 2011
  • In this paper, the bonding strengths of co-cured T800 carbon/epoxy composite-aluminum single lap joints with and without additional pressures were investigated using the pressure information induced by the fiber tension during a filament winding process. The specimens of all the tests were fabricated by an autoclave vacuum bag de-gassing molding being controlled forming pressures (absolute pressures of 0.1MPa, 0.3MPa and 0.7MPa including vacuum). A special device which can act uniform additional pressures on the joining part of the single lap joint specimen was designed to measure the bonding strengths of composite-aluminum liners of type III hydrogen pressure vessel fabricated by a filament winding process. After the three different additional pressures (absolute pressures of 0.1MPa, 0.3MPa and 0.7MPa) were applied to the specimens the effect of the additional pressures on the bonding strengths of the co-cured single-lap joints were evaluated.

AN EXPERIMENTAL STUDY ON THE SEALING EFFECT OF A FEW CAVITY LINERS UPON THE DENTINAL TUBULE (수종(數種) 와동이장재(窩洞裏裝材)의 상아질세관(象牙質細管) 폐쇄효과(閉鎖效果)에 관(関)한 실험적(實β的) 연구(硏究))

  • Son, Ho-Hyun
    • Restorative Dentistry and Endodontics
    • /
    • v.6 no.1
    • /
    • pp.141-147
    • /
    • 1980
  • The sealing effect of a few cavity liners upon the dentinal tubule were studied in vitro. The materials employed in this study were Silcot (SP$\'{E}$CIALIT$\'{E}$S SEPTODONT, M.-T. GENDRAULT, Pharmacien), Hypo-Cal(Ellman Dental Mfg.Co.Inc.), Cavity Lining(De Trey), and Copaute(Harry J. Bosworth Co.). Freshly extracted human teeth were devided into 5 groups by age-under twenty, twenties, thirties, forties, and over fifty. Class V cavities were prepared routinely. The cavity walls of eight teeth of each group were lined by Silcot, Copalite, Cavity Lining, and Hypo-Cal. Remaining eight were not lined as a control. These specimens were immersed in dye solution (2 gm eosin Y to 800 cc distilled water) for 48 hours to allow maximum dye penetration into dentinal tubules. Each specimen was sectioned longitudinally including Class V cavity floor under water spray. Dye penetration into dentinal tubules were examined and following results were obtained. 1. Liners used on this study showed more or less dye penetration into dentinal tubules. But compared with the teeth without lining, the dye penetration of lined specimens were decreased. 2. Of these liners tested, Silcot was the most effective sealer upon the dentinal tubules. Copalite was the moderate sealer and Cavity Lining showed a tendency similar to Copalite. Hypo-Cal revealed the greatest dye penetration. 3. As the age was increased, the more the dye penetration into the dentinal tubules was decreased.

  • PDF

Effect of irrigants on the color stability, solubility, and surface characteristics of calcium-silicate based cements

  • Selen Kucukkaya Eren;Sevinc Askerbeyli Ors;Hacer Aksel;Senay Canay ;Duygu Karasan
    • Restorative Dentistry and Endodontics
    • /
    • v.47 no.1
    • /
    • pp.10.1-10.11
    • /
    • 2022
  • Objectives: This study aimed to investigate the color stability, solubility, and surface characteristics of 3 calcium silicate-based cements (CSCs) after immersion in different solutions. Materials and Methods: ProRoot white mineral trioxide aggregate (MTA), Biodentine, and Endosequence Root Repair Material (ERRM) were placed in cylindrical molds and stored at 37℃ for 24 hours. Each specimen was immersed in distilled water, 5% sodium hypochlorite (NaOCl), 2% chlorhexidine, or 0.1% octenidine hydrochloride (OCT) for 24 hours. Color changes were measured with a spectrophotometer. Solubility was determined using an analytical balance with 10-5 g accuracy. The surface characteristics were analyzed using scanning electron microscopy and energy-dispersive spectroscopy. Data were analyzed using 2-way analysis of variance, the Tukey test, and the paired t-test. Results: MTA exhibited significant discoloration in contact with NaOCl (p < 0.05). White precipitation occurred on the surfaces of Biodentine and ERRM after contact with the solutions, and none of the materials presented dark brown discoloration. All materials showed significant solubility after immersion in the solutions (p < 0.05), irrespective of the solution type (p > 0.05). The surface topography and elemental composition of the samples showed different patterns of crystal formation and precipitation depending on the solution type. Conclusions: All materials presented some amount of solubility and showed crystal precipitation after contact with the solutions. Biodentine and ERRM are suitable alternatives to ProRoot MTA as they do not exhibit discoloration. The use of OCT can be considered safe for CSCs.

Effect of Accelerated Aging on the Color Stability of Dual-Cured Self-Adhesive Resin Cements

  • Kim, Ah-Rang;Jeon, Yong-Chan;Jeong, Chang-Mo;Yun, Mi-Jung;Huh, Jung-Bo
    • Journal of Korean Dental Science
    • /
    • v.8 no.2
    • /
    • pp.49-56
    • /
    • 2015
  • Purpose: The effect of accelerated aging on color stability of various dual-cured self-adhesive resin cements were evaluated in this study. Materials and Methods: Color stability was examined using three different brands of dual-cured self-adhesive resin cements: G-CEM LinkAce (GC America), MaxCem Elite (Kerr), and PermaCem 2.0 (DMG) with the equivalent color shade. Each resin cement was filled with Teflon mold which has 6 mm diameter and 2 mm thickness. Each specimen was light cured for 20 seconds using light emitting diode (LED) light curing unit. In order to evaluate the effect of accelerated aging on color stability, color parameters (Commission Internationale de l'Eclairage, CIE $L^*$, $a^*$, $b^*$) and color differences (${\Delta}E^*$) were measured at three times: immediately, after 24 hours, and after thermocycling. The $L^*$, $a^*$, $b^*$ values were analyzed using Friedman test and ${\Delta}E^*$ values on the effect of 24 hours and accelerated aging were analyzed using t-test. These values were compared with the limit value of color difference (${\Delta}E^*=3.7$) for dental restoration. One-way ANOVA and Scheff's test (P<0.05) were performed to analyze each ${\Delta}E^*$ values between cements at each test period. Result: There was statistically significant difference in comparison of color specification ($L^*$, $a^*$, $b^*$) values after accelerated aging except $L^*$ value of G-CEM LinkAce (P<0.05). After 24 hours, color difference (${\Delta}E^*$) values were ranged from 2.47 to 3.48 and $L^*$ values decreased and $b^*$ values increased in all types of cement and MaxCem Elite had high color stability (P<0.05). After thermocycling, color change's tendency of cement was varied and color difference (${\Delta}E^*$) values were ranged from 0.82 to 2.87 and G-CEM LinkAce had high color stability (P<0.05). Conclusion: Color stability of dual-cured self-adhesive resin cements after accelerated aging was evaluated and statistically significant color changes occurred within clinically acceptable range.

REMINERALIZATION DEPTH OF CPP-ACP ON DEMINERALIZATION HUMAN ENAMEL IN VITRO (탈회된 법랑질에서 CPP-ACP의 재광화 깊이)

  • Choi, Han-Ju;Choi, Yeong-Chul;Kim, Kwang-Chul;Choi, Sung-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.2
    • /
    • pp.278-286
    • /
    • 2008
  • Many studies regarding Casein phosphopeptides-amorphous calcium phosphate(CPP-ACP) have demonstrated the remineralization ability on the demineralized enamel surface. A question is still remained that how deep can the calcium (Ca) and phosphorus (P) ions supplied by the CPP-ACP paste penetrate into the enamel subsurface. The aims of this study were to measure the penetrating depth of Ca and P ions in the demineralized human enamel in vitro, and were to determine the amount and depth of Ca and P ions according to the duration. The amount and depth of Ca and P ions were measured by microscopic observation with Field Emission Scanning Electron Microscopy (FE-SEM; LEO SUPRA 55, Carl Zeiss, Germany) and Energy Dispersive X-ray Spectrometer (EDS; GENESIS 2000, EDAX, USA: Linescan of Calcium and Phosphorus). Freshly extracted four human 1st premolars were obtained from the Dept. of Pediatric Dent., Kyung Hee Univ. Buccal surfaces of the 1st premolars were covered with nail varnish to form a window on the middle third of buccal surface. All of the teeth with enamel windows were immersed in a solution of 0.1 M lactic acid, Carbopol C907 (carboxypolymethylene BF Goodrich, Cleveland, OH, USA) at pH 4.8, and then incubated for 7 days. Each tooth crown was sawn in half through the midline of buccal window along the long axis of premolar. The four blocks of premolars were immersed in a 10-times diluted solution of CPP-ACP paste (Tooth Mousse, GC Corp., Tokyo, Japan) for 1, 2, 3 and 5 weeks while the rests were immersed in a placebo solution (distilled water) for the same duration. Each specimen was embedded in epoxy resin, and was sectioned perpendicular to the window, using a water-cooled diamond blade saw. The spectrum density indices of Ca and P were measured in the sound, de- and remineralized enamels by FE-SEM and EDS. The Student's t test was performed to compare the Spectrum Density Indices (SDI) of sound, re-and demineralized enamels, and to compare the differences among the durations. Followings are the conclusion : 1. The penetration depth of the remineralizing ions (Ca & P) of CPP-ACP paste is related to the depth of demineralized enamel (approximately $1050{\sim}1350{\mu}m$). It is revealed that the penetration depth of both ions reaches full thickness of decalcification and even slightly into the sound enamel. 2. The Ca & P levels of remineralized enamels in 1, 2 weeks were significantly higher than those of the sound enamels (p<0.05). 3. No statistically significant difference of Ca & P levels was found in relation with the increasing duration of remineralization (p>0.05).

  • PDF