• Title/Summary/Keyword: DCS Logic

Search Result 34, Processing Time 0.023 seconds

The Construction Of Water Treatment Operation System Using Fieldbus (필드버스(Lonworks)를 이용한 수운영시스템 구축)

  • Park, J.S.;Kim, I.S.;Song, H.S.
    • Proceedings of the KIEE Conference
    • /
    • 2004.07d
    • /
    • pp.2257-2259
    • /
    • 2004
  • Water Treatment Operation System is applied in most water treatment plants with DCS(Distributed Control System) or PLC(Programmable Logic Controller) system. But it has a lot of problems in viewpoint of cost and expansibilities. Therefore, we rose demand about a system that it was easier, convenient and a few costs. So, It was appeared at a Fieldbus as an alternative about this. It is used in ail industrial fields, but because of the economic reality that we can't removes the existing system, and cannot introduce new technology. Because it is actual to be hard to find an actual implementation reward and way of domestic fieldbus technology, we cannot be acknowledged with reliability in the industrial spot. Therefore, We is going to look into a fieldbus application reward in this paper. That is, We recognize structure and a kind of a fieldbus in a Chapter 2. And we is going to look into difference between a PLC method and fieldbus methods in a Chapter 3. Also, We are going to compare the system that used PLC with the system that used fieldbus (LonWorks). And the objects are JinAn and Wonju where a field bus was applied to.

  • PDF

Design Of Fuzzy Controller for the Steam Temperature Process in the Coal Fired Power Plant

  • Shin, Sang Doo;Kim, Yi-Gon;Lee, Bong Kuk;Bae, Young Chul
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.4 no.2
    • /
    • pp.187-192
    • /
    • 2004
  • In this paper, we proposed the method to design fuzzy controller using the experience of the operating expert and experimental numeric data for the robust control about the noise and disturbance instead of the traditional PID controller for the main steam temperature control of the thermal power plant. The temperature of main steam temperature process has to be controlled uniformly for the stable electric power output. The process has the problem of the hunting for the cases of various disturbances. In that case, the manual action of the operator happened to be introduced in some cases. We adopted the TSK (Takagi-Sugeno-Kang) model as the fuzzy controller and designed the fuzzy rules using the informations extracted directly from the real plant and various operating condition to solve the above problems and to apply practically. We implemented the real fuzzy controller as the Function Block module in the DCS(Distributed Control System) and evaluated the feasibility through the experimental results of the simulation.

Nonlinear Acceleration Controller Design for DACS Type Kill Vehicle (DACS형 직격요격비행체의 비선형 가속도 조종루프 설계)

  • Lee, Chang-Hun;Kim, Tae-Hun;Jun, Byung-Eul
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.19 no.3
    • /
    • pp.54-64
    • /
    • 2015
  • This paper deals with an acceleration controller design for a kill vehicle equipped with a divert and attitude control system (DACS). In the proposed method, the attitude control system (ACS) is used to produce the thrust command to nullify angle-of-attack. For the angle-of-attack control, a nonlinear angle-of-attack controller is proposed based on the feedback linearization methodology. Since the flight path angle is identical to the attitude angle under the condition of zero angle-of-attack, the divert control system (DCS) can directly produce the lateral acceleration which is demanded from the guidance loop. In the proposed method, we can minimize the aerodynamic uncertainty due to the propulsive force. Additionally, we can simplify the operation logic of DCS and ACS. In this paper, nonlinear simulations are performed to show the performance of the proposed method.

A Design of MIB for Power System Using XML Web Service (XML 웹서비스를 이용한 전력시스템 MIB 설계)

  • Jung, Nam-Joon;Yang, Il-Gwon;Song, Jae-Ju;Ko, Jong-Min;Oho, Do-Eun
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2008.06b
    • /
    • pp.473-478
    • /
    • 2008
  • 산업계에서의 제어시스템(Control System)은 크게 SCADA(Supervisory Control And Data Acquisition) 시스템, 분산 제어시스템(Distributed Control System, DCS), PLC 시스템 (Programmable Logic Controller System)으로 분류할 수 있다. 특히 전력분야의 SCADA 시스템은 목적상 실시간의 대규모 측정 정보 취득을 목적으로 운영되며, 실시간 및 이력 데이터베이스, 원격 데이터 취득, 다양한 데이터 처리, Supervisory Control 등 복잡한 기능과 다양한 전력시스템과의 정보교환이 요구된다. 다양한 전력시스템과의 정보 교환을 위한 표준화 요구에 부응하여, 향후 전력시스템은 표준화되고 공개된 정보모델을 활용한 통합시스템 개발이 요구된다. 본 논문에서는 전력 공통정보모델(CIM)과 애플리케이션 통합 정보기술을 이용한 전력시스템의 메시지 통합버스 설계에 대하여 기술하고자 한다.

  • PDF

Field Application of H-Bridge Multi-level Inverter for Fluidized Bed Combustion Boiler Secondary Air Fan (200MW 석탄화력 순환 유동층 보일러 이차공기송풍기용 H-브릿지 멀티레벨 인버터 현장적용)

  • Kim, Bong-Suck;Ryu, Ho-Seon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.12 no.5
    • /
    • pp.424-431
    • /
    • 2007
  • This thesis proposed H-Bridge Multi-Level Inverter for Fluidized Bed Combustion Boiler Secondary Air Fan in 200MW thermal power plant. The adjustable speed drive systems improve the efficiency in lightly load condition and extend the life span of motor by limiting the over current at starting. H-Bridge Multi-level Inverter is composed of the several series low voltage power cell inverters, which have the independent isolated do link, in each phase. KEPRI(Korea Electric Power Research Institute) has successfully completed to develop, install, and commission H-Bridge Multi-level Inverter(6.6kV, 1MVA). This thesis gives a full detail about H-Bridge Multi-level Inverter, proposed boiler DCS(Distributed Control System) logic, and commissioning test result.

DAQ System을 활용한 초지기 맥동현상의 개선

  • 이영준;김도환;서동준;고두석;이복진
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2001.04a
    • /
    • pp.81-81
    • /
    • 2001
  • 초지 공정은 wire, roll, pump등의 회전체로 이루어진 공정이 거의 대부분이기 때문에 주기적으로 변동하는 성분들이 많고, QCS(Quality Control System) 및 DCS(Distributed Co n ntrol System)상에 서 의 자동 Control Logic에 의 한 불안정 (Fluctuation)요소도 내 재 되 어 있 어 이에 대한 분석이 필요하다. 이러한 주기적인 변동은 제품의 여러 물성(평량, 두께, 광택 도등) 에 영향을 미치게 되어 품질의 균일성이나 프로파일에 영향을 미치게 된다. 따라서 공정상이나 품질에서 주기적으로 변동하는 성분을 추출하여 공정 각 성분과 연관을 시키변 품질에 나타나는 주기적 성분의 요인이 어느 부분에서 기인하는 지를 직접적으로 찾아낼 수 있고 이의 개선을 통해 품질의 균일성 및 프로파일 향상을 꾀할 수 있다. 본 연구에서는 Air padded type 헤드박스 초지기에서 DAQ(Data Acquisition) System 을 이용하여 각 공정별로 MD(Machine Direction)방향으로의 변동을 측정하고 제품의 물성 변동과 비교하였다. DAQ System은 각 공정상의 전기적 신호를 높은 주파수 영역까지 다채널로 동시에 받 아 들일 수 있는 장치로 이 시스템을 활용하여 공정상의 Machine chest 농도, Stock box 유량 및 레벨, Fan pump RPM, Cleaner압력, Screen압력, H!B압력 및 레벨, Silo level등 공 정요소의 변동상태와 상호영향을 분석하였다. 이러한 공정 각 요소의 변동과 MD 방향의 제품 물성 값(Tapio, Paper Variation Analyzer에 대한 비교 분석결과 제품 평량에서 주기적인 변동성분을 확인할 수 있었고 이중 큰 비 중을 차지하는 것이 fνB 레벨 변동주기와 일치하는 것을 찾아낼 수 있었다. 이에 근거하여 D DCS system의 control 요소인 튜닝 parameter(P,I 값)들을 미 세 조정 하여 제 품의 MD방향 평량 변동 진폭을 기존 수준의 30% 수준으로 감소시킬 수 있었다. 그 결과 COV(표준편차/ 평량)값을 0.8-1.2%에서 0.6-0.8%수준으로 낮출 수 있었고 이에 따라 CD (Cross Direction) 방향의 제품 Profile도 함께 개선되는 효과를 거둘 수 있었다.

  • PDF

Networked Intelligent Motor-Control Systems Using LonWorks Fieldbus

  • Hong, Won-Pyo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.365-370
    • /
    • 2004
  • The integration of intelligent devices, devices-level networks, and software into motor control systems can deliver improved diagnostics, fast warnings for increased system reliability, design flexibility, and simplified wiring. Remote access to motor-control information also affords an opportunity for reduced exposure to hazardous voltage and improved personnel safety during startup and trouble-shooting. This paper presents LonWorks fieldbus networked intelligent induction control system architecture. Experimental bed system with two inverter motor driving system for controlling 1.5kW induction motor is configured for LonWorks networked intelligent motor control. In recent years, MCCs have evolved to include component technologies, such as variable-speed drives, solid-state starters, and electronic overload relays. Integration was accomplished through hardwiring to a programmable logic controller (PLC) or distributed control system (DCS). Devicelevel communication networks brought new possibilities for advanced monitoring, control and diagnostics. This LonWorks network offered the opportunity for greatly simplified wiring, eliminating the bundles of control interwiring and corresponding complex interwiring diagrams. An intelligent MCC connected in device level control network proves users with significant new information for preventing or minimizing downtime. This information includes warnings of abnormal operation, identification of trip causes, automated logging of events, and electronic documentation. In order to show the application of the multi-motors control system, the prototype control system is implemented. This paper is the first step to drive multi-motors with serial communication which can satisfy the real time operation using LonWorks network.

  • PDF

Design and Measurement of an SFQ OR gate composed of a D Flip-Flop and a Confluence Buffer (D Flip-Flop과 Confluence Buffer로 구성된 단자속 양자 OR gate의 설계와 측정)

  • 정구락;박종혁;임해용;장영록;강준희;한택상
    • Progress in Superconductivity
    • /
    • v.4 no.2
    • /
    • pp.127-131
    • /
    • 2003
  • We have designed and measured an SFQ(Single Flux Quantum) OR gate for a superconducting ALU (Arithmetic Logic Unit). To optimize the circuit, we used WRspice, XIC and Lmeter for simulations and layouts. The OR gate was consisted of a Confluence Buffer and a D Flip-Flop. When a pulse enters into the OR gate, the pulse does not propagate to the other input port because of the Confluence Buffer. A role of D Flip-Flip is expelling the data when the clock is entered into D Flip-Flop. For the measurement of the OR gate operation, we attached three DC/SFQs, three SFQ/DCs and one RS Flip -Flop to the OR gate. DC/SFQ circuits were used to generate the data pulses and clock pulses. Input frequency of 10kHz and 1MHzwere used to generate the SFQ pulses from DC/SFQ circuits. Output data from OR gate moved to RS flip -Flop to display the output on the oscilloscope. We obtained bias margins of the D Flip -Flop and the Confluence Buffer from the measurements. The measured bias margins $\pm$38.6% and $\pm$23.2% for D Flip-Flop and Confluence Buffer, respectively The circuit was measured at the liquid helium temperature.

  • PDF

Retrofit of Analog Boiler Control Systems with Digital Control Systems in a Thermal Power Plant

  • Park, Doo-Yong;Byun, Seung-Hyun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1304-1308
    • /
    • 2005
  • This paper presents the case that the existing analog control systems were retrofitted with digital DCS(Distributed Control System)s for boiler unit in thermal power plant. Replacement of existing worn-out or obsolete analog control systems has been considered. Replacement of existing analog control systems with another analog control systems has lots of difficulties in maintaining the systems due to being out of stock. Due to those difficulties, existing analog control systems have been retrofitted with digital DCSs in many industrial sites. KEPRI(Korea Electric Power Research Institute) accomplished the project that retrofitted analog control systems with the developed DCSs for boiler unit in middle-scale coal-fired thermal power plant. The benefits of an upgrade to digital control include a increase of reliability due to system redundancy, ease of modifying the control logic and the parameters of function block, ease of maintenance due to available spare parts, improvement of information display, ease of modifying MMI(Man Machine Interface) displays, a increase in system availability, and improvement of control performance. This paper describes how to use the parameters of existing analog controllers, the implementation of digital PID controller, control system configuration for boiler unit in thermal power plant, some boiler control loops, control result during commissioning, and the comparison of boiler characteristic test data after retrofitting with the existing test data.

  • PDF

An Analysis on the Formative Requirements for Hybrid Characters and Influencing Relationship with Consumer Preference (하이브리드 캐릭터의 조형 요건과 소비자 선호도와의 영향관계 분석)

  • Kim, Jun-Su
    • Journal of Digital Contents Society
    • /
    • v.19 no.7
    • /
    • pp.1389-1395
    • /
    • 2018
  • Hybrid is explained based on the logic of combination such as cross, melding, permeation, fusion, convergence etc. Such combination shows that it is more creative and effective in case of heterogeneity as compared to homogeneity and the same kind, and hybrid character has its meaning as a mean to produce a new creative image. In the context, this study aims to analyze influencing relationship through a practical analysis on how formative requirements for hybrid characters affects consumer preference. For the foregoing, this study conducted multiple regression analysis having familiarity, originality, meaningfulness, diversity as independent variables for formative requirements for characters, and consumer preference as a dependent variable. Analysis results show that familiarity, originality, diversity have a positive effect on consumers, whereas, meaningfulness has no significant impact on the consumer preference.