• Title/Summary/Keyword: DC23

Search Result 395, Processing Time 0.057 seconds

Oxygen Interstitial Defects and Ion Hopping Conduction of $X ThO_2 + (1-X) Gd_2O_3 $Solid Solutions: $O.O8{\le}X{\le}0.12$

  • Park, Sung-Ho;Kim, Yoo-Young;Kim, Keu-Hong
    • Bulletin of the Korean Chemical Society
    • /
    • v.11 no.4
    • /
    • pp.339-342
    • /
    • 1990
  • $Gd_2O_3-ThO_2$ solid solutions containing 8,10 and 12 mol % $ThO_2$ were synthesized with spectroscopically pure $Gd_2O_3,$ and $ThO_2$ polycrystalline powders. X-ray diffraction revealed that all synthesized specimens have the modified fluorite structure, and the lattice parameter of $Gd_2O_3$ is nearly unchanged with increasing $ThO_2$ mol %. Both ac and dc conductivities were measured in the temperature range $500-1100^{\circ}C$ under $Po_2's$ from $10^{-6}$ to $10^{-1}$ atm. The dc conductivities are nearly independent of $Po_2,$ and agree with the ac values. This implies that the solid solutions are ionic conductors. The conductivity increases with increasing $ThO_2$ mol % with an average activation energy of 1.23 eV. An oxygen interstitial defect and ionic hopping conduction are suggested.

A study on the fabrication techologies for the 23GHz LNAs (23GHz대 저잡음 증폭기의 제작기술에 관한 연구)

  • 안동식;장동표
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.34D no.3
    • /
    • pp.9-16
    • /
    • 1997
  • A 23GHz 1-stage LNA was designed by using new topology of coupled line type with EEsof softwares and modified by using MPIE numerical analysis. The parallel coupled filter-type matching sections give impedance matching and DC blocking simultaneously, and have small discontinuities. This matching scheme has simple structure in the design process and give small error. The EFT chip was directly attached to the ground metal. The designed LAN gives 6.2dB gain and 2.5dB noise figure without considering the loss of connectors. Through these results, it was verified that our design process, matching schemes and fabrication technologies was valied for developing 20GHz-band LNA.

  • PDF

A study on the design technologies for the 1-state 23GHz LNAs (23GHz대 1단 저잡음 증폭기의 설계 기술에 관한 연구)

  • 장동필;안동식
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.22 no.5
    • /
    • pp.974-980
    • /
    • 1997
  • The 23GHz 1-state LNA was designed by using MPIE numerical analysis and conventional design EEsof softwares. The circuit was designed using conventional tools but analyzed and modified by using numerical MPIE tools. he matching sections was designed with parallel coupled filter-type, which gives impedance matching and DC blocking and has small discontinuities. THe FET chip is directly attached to the graound metal. The designed LNA gives 5.8dB gain and 2.5dB noise figure withoug considering the loss and impedance shift of connectors that degenerate the gain and noise figure considerably. this results gives very promising characteristics for our design process and matching schemes and fabrication technologies.

  • PDF

An investigation Study of Electromagnetic Compatibility for Power Module (전원모듈의 전자파 적합성(EMC) 특성 분석)

  • Chae, Gyoo-Soo
    • Journal of the Korea Convergence Society
    • /
    • v.7 no.6
    • /
    • pp.23-28
    • /
    • 2016
  • In this study, an investigation study on EMC(Electromagnetic Compatibility) is presented for power converter circuit. A DC-DC power converter circuit using LT3652 chip is designed and fabricated. The simulation results using ANSYS SIwave for far field radiation and unwanted emissions are presented. To minimize the unwanted emissions, we design a optimized circuit by using capacitors and ground posts. The conducted and radiation emissions are measured in the EMC test chamber based on standardized testing procedures of CISPR 22. The measured EMI emission values for a power converter circuit are presented and compared with the original circuit. The results show that the unwanted emissions from the circuit are tremendously diminished due to the applied EMI reduction techniques. The results proposed here can be usefully applied on designing power converter modules.

A 12b 10MS/s CMOS Pipelined ADC Using a Reference Scaling Technique (기준 전압 스케일링을 이용한 12비트 10MS/s CMOS 파이프라인 ADC)

  • Ahn, Gil-Cho
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.11
    • /
    • pp.16-23
    • /
    • 2009
  • A 12b 10MS/s pipelined ADC with low DC gain amplifiers is presented. The pipelined ADC using a reference scaling technique is proposed to compensate the gain error in MDACs due to a low DC gain amplifier. To minimize the performance degradation of the ADC due to amplifier offset, the proposed offset trimming circuit is employed m the first-stage MDAC amplifier. Additional reset switches are used in all MDACs to reduce the memory effect caused by the low DC gain amplifier. The measured differential and integral non-linearities of the prototype ADC with 45dB DC gain amplifiers are less than 0.7LSB and 3.1LSB, respectively. The prototype ADC is fabricated in a $0.35{\mu}m$ CMOS process and achieves 62dB SNDR and 72dB SFDR with 2.4V supply and 10MHz sampling frequency while consuming 19mW power.

STUDIES ON PRODUCTION AND EFFICIENT UTILIZATION OF LIVESTOCK EMBRYOS BY IN VITRO FERTILIZATION AND MICROMANIPULATION IV. NUCLEAR TRANSPLANTATION AND ELECTROFUSION FOR CLONING IN BOVINE FOLLICULAR OOCYTES

  • Chung, Y.C.;Kim, C.K.;Song, X.X.;Yoon, J.T.;Choi, S.H.;Chung, Y.H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.8 no.6
    • /
    • pp.641-645
    • /
    • 1995
  • This study was conducted to develop a method for production of nuclear transplant bovine embryos using in vitro-matured (IVM) oocytes and to examine the effect of different conditions of electrofusion on fusion rate and developmental capacity of donor nucleus transplanted to enucleated oocytes. Eight- to sixteen-cell embryos derived from oocytes matured and fertilized in vitro used as donor blastomeres and IVM oocytes were used as recipient oocytes. Oocytes were enucleated immediately after 23-24 h IVM and then reconstituted with a donor blastomere in two different micromanipulation media. Fusion rate and subsequent development of the reconstituted oocytes was compared under the different electric stimuli and recipient oocyte ages. Success rate of enucleation was significantly higher in TCM-199 medium containing FCS than in DPBS. The high fusion rate(75-94%) and development (6.4-14.8%) to morulae and blastocyst (M + B) were obtained from 0.6-0.75 kV/cm DC voltage, although total cleavage was not different among the electric pulses. Most optimal condition of electric stimulation for fusion and development was 1 DC voltage of 0.75 kV/cm, in which 80.5% of oocytes were fused, 80.0% and 31.7% of which was cleaved and developed to M + B, respectively. No M + B was obtained from 1.2 kV/cm DC voltage regardless of pulse frequency. Recipint oocyte age at electrofusion greatly affected the cleavage and subsequent development to M + B, showing high rate at 40-41 h oocyte maturation. These results suggest that a suitable condition of electrofusion for donor nuclei derived from IVF may be 1-2 DC pulses of 0.7 kV/cm for $70{\mu}sec$ and that processing of a transplanted nucleus in IVM oocytes may be affected by maturation age of recipient oocytes.

Cisplatin-Based Therapy for the Treatment of Elderly Patients with Non-Small-Cell Lung Cancer: a Retrospective Analysis of a Single Institution

  • Inal, Ali;Kaplan, M. Ali;Kucukoner, Mehmet;Urakcl, Zuhat;Karakus, Abdullah;Islkdogan, Abdurrahman
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.5
    • /
    • pp.1837-1840
    • /
    • 2012
  • Background: In spite of the fact that platinum-based doublets are considered the standard therapy for patients with advanced non-small-cell lung cancer (NSCLC), no elderly-specific platinum based prospective phase III regimen has been explored. The aim of this retrospective singlecenter study was to evaluate the efficacy and side effects of cisplatin-based therapy specifically for the elderly. Methods: Patients receiving platinum-based treatment were divided into three groups. In the first group (GC), Gemcitabine was administrated at 1000 $mg/m^2$ on days 1, 8 and cisplatin was added at 75 $mg/m^2$ on day 1. In the second group (DC), 75 $mg/m^2$ docetaxel and cisplatin were administered on day 1. The third group (PC) received 175 mg of paclitaxel and 75 mg of cisplatin on day 1. These treatments were repeated every three weeks. Result: GC arm had 36, the DC arm 42 and the PC arm 29 patients. Grade III-IV thrombocytopenia was higher in the GC arm (21.2% received GC, 2.8% received DC, and 3.8% received PC), while sensory neuropathy was lower in patients with GC arm (3.0%, 22.2%, and 23.1% received GC, DC and PC, respectively). There were no statistically significant difference in the response rates among the three groups (p>0.05). The median Progression-free survival (PFS) was 5.0 months and the median Overall survival (OS) in each group was 7.1, 7.4 and 7.1 months, respectively (p>0.05). Conclusion: The response rate, median PFS and OS were similar among the three treatment arms. Grade III-IV thrombocytopenia was higher in the GC arm, while the GC regimen was more favorable than the other cisplatin-based treatmetns with regard to sensory neuropathy.

Magnetoelectric Characteristics on Layered Fe78B13Si9/PZT/Fe78B13Si9 Composites for Magnetic Field Sensor (자기센서용 Fe78B13Si9/PZT/Fe78B13Si9 적층구조 소자의 ME 특성)

  • Ryu, Ji-Goo;Jeon, Seong-Jeub
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.3
    • /
    • pp.181-187
    • /
    • 2015
  • The magnetoelectric characteristics on layered $Fe_{78}B_{13}Si_9/PZT$ and $Fe_{78}B_{13}Si_9/PZT/Fe_{78}B_{13}Si_9$($t_m=0.017$, 0.034mm) composites by epoxy bonding for magnetic field sensor were investigated in the low-frequency range and resonance frequency range. The optimal bias magnetic field $H_{dc}$ of these samples was about 23~63 Oe range. The Me coefficient of $Fe_{78}B_{13}Si_9/PZT/Fe_{78}B_{13}Si_9(t_m=0.034mm)$ composites reaches a maximum of $186mV/cm{\cdot}Oe$ at $H_{dc}=63Oe$, f=50 Hz and a maximum of $1280mV/cm{\cdot}Oe$ at $H_{dc}=63Oe$, resonance frequency $f_r=95.5KHz$. The output voltage shows linearity proportional to ac fields $H_{ac}$ and is about U=0~130.6 mV at $H_{ac}=0{\sim}7Oe$, f=50 Hz, U=0~12.4 V at $H_{ac}=0{\sim}10Oe$, $f_r=95.5KHz$(resonance frequency). The optimal frequency(f=50 Hz) of this sample is around the utility ac frequency(f=60 Hz). Therefore, this sample will allow for ac magnetic field sensor at utility frequency and low bias magnetic fields $H_{dc}$.

A Study on Electrical Conduction of As-Te-Si-Ge Amorphous Semiconductor (As-Te-Si-Ge 유리질 반도체의 전기전도에 관한 연구)

  • Park, Chang-Yeub;Wang, Jin-Seok;Jeong, Hong-Bae
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.12 no.2
    • /
    • pp.18-23
    • /
    • 1975
  • The dc conductivity, ac conductivity and switching effect of As.Te-Si.Ge have beon investigated. The dc conductivity ranged from $3{\times}10^{-7}{\Omega}^{-1}cm^{-1}$ to $1.5{\times}10^{-8}{\Omega}^{-1}cm^{-1}$ at room temperature and was found to be expressed by ${\sigma}$ = ${\sigma}_0$exp(-${\Delta}$E/kT) below the phase transition temperature Tg. The ac conductivity was much higher than dc conductivity and this result is consistent to experimental formula ${\sigma}$(w)=${\sigma}_0+Aw^n$. In the temperature range of 298$^{\circ}K$ ~ $473^{\circ}K$ the ac conductivity was independent of temperature at 200KHs. At lower frequencies the ac conductivity increased strong1y with temperature. Also, it has been found that all samples showed a threshold switching, but not a memory switching.

  • PDF

Tensile Stress Measurement of Tendon by Means of Non-contact Yoke Method (Yoke를 사용한 비접촉 방법에 의한 텐던 인장응력 측정)

  • Kang, Sunju;Son, Derac;Joh, Changbin;Lee, Jungwoo
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.1
    • /
    • pp.19-23
    • /
    • 2016
  • In this study, we have constructed a measuring system to investigate tensile stress measurement of tendons, which is employed in bridges, by means of the non-destructive and non-contact method. The measuring system consists of tensile stress applying apparatus up to 2 GPa, and power supply for ac and dc current to tendon directly to magnetize tendon in circular direction and to coil wound on yoke to magnetize tendon in axial direction. We have used two kinds of tendon, which were produced by different companies, using the measuring system constructed in this work. Two kinds of experiments are carried out in this work; $1^{st}$ experiment : ac current was applied to the tendon and dc current was applied to coil wound on the yoke, and voltage induced from search coil wound on yoke (SCY) was measured and $2^{nd}$ experiment : dc current was applied to the tendon and ac current was applied to coil wound on the yoke, and voltage induced from search coil on tendon (SCT) was measured. In case of $1^{st}$ experiment, voltage induced from SCY was changed below 200MPa tensile stress but the voltage was not increased above 200 MPa. In case of $2^{nd}$ experiment, voltage induced from SCT was decreased up to 1.5 GPa linearly. We expect that $2^{nd}$ experiment could be applied to the non-destructive testing of tensile stress measurement of tendon.